Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Atomic force microscopy: Emerging illuminated and operando techniques for solar fuel research

Integrated photoelectrochemical devices rely on the synergy between components to efficiently generate sustainable fuels from sunlight. The micro- and/or nanoscale characteristics of the components and their interfaces often control critical processes of the device, such as charge-carrier generation, electron and ion transport, surface potentials, and electrocatalysis. Understanding the spatial properties and structure–property relationships of these components can provide insight into designing scalable and efficient solar fuel components and systems. These processes can be probed ex situ or in situ with nanometer-scale spatial resolution using emerging scanning-probe techniques based on atomic force microscopy (AFM). In this Perspective, we summarize recent developments of AFM-based techniques relevant to solar fuel research. We review recent progress in AFM for (1) steady-state and dynamic light-induced surface photovoltage measurements; (2) nanoelectrical conductive measurements to resolve charge-carrier heterogeneity and junction energetics; (3) operando investigations of morphological changes, as well as surface electrochemical potentials, currents, and photovoltages in liquids. Opportunities for research covered here include: (1) control of ambient conditions for performing AFM measurements; (2) in situ visualization of corrosion and morphological evolution of electrodes; (3) operando AFM techniques to allow nanoscale mapping of local catalytic activities and photo-induced currents and potentials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tilted fluctuation electron microscopy

Fluctuation electron microscopy (FEM) is a scanning nanodiffraction-based method that offers a unique approach to characterizing nanometer-scale medium-range order (MRO) in disordered materials. In addition to determining the degree of MRO, careful analysis of scanning nanodiffraction data can also be used to determine strain in thin film amorphous samples. We applied FEM to characterize the strain and MRO of magnetron sputtered amorphous tantalum (a-Ta) thin films over a range of tilt angles from 0° to 45° in order to measure any deviations between the in-plane and out-of-plane strain and MRO. We validate our approach using electron diffraction simulations of FEM experiments for a-Ta. We measure anisotropic strain in the simulated a-Ta diffraction patterns and find that the experimental a-Ta is isotropically strained within the accuracy of our method. Our approach provides a workflow for acquiring tilted scanning nanodiffraction data, determining the relative strain and ordering as a function of in- A nd out-of-plane directions, and removing any artifacts induced in FEM data due to strain. We also describe some limitations of the tilted FEM method when applied to thin films with very low strains.

36 MATERIALS SCIENCE↗

Femtosecond photoemission electron microscopy of surface plasmon polariton beam steering via nanohole arrays

Directional control over surface plasmon polariton (SPP) waves is a prerequisite for the development of miniaturized optical circuitry. Here, the efficacy of single and dual component SPP steering elements is explored through photoemission electron microscopy. Our imaging scheme relies on two-color photoemission and counter-propagating SPP generation, which collectively allow SPPs to be visualized in real space. Wave-vector difference mixing between two-dimensional arrays of nanoholes and photon momenta enables SPP steering with directionality governed by the array lattice constant. The magnitude of grating momentum required to achieve counter-propagation guarantees efficient steering over the full range of the negative half-space. In our dual component configuration, separate SPP generation and Bragg diffraction based steering optics are employed. We find that array Bragg planes principally influence the SPP angles through the array band structure, which allows us to visualize both positive and negative refractory waves.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A transmission electron microscopy study of dislocation propagation and filtering in highly mismatched GaSb/GaAs heteroepitaxy

Monolithic integration of lattice-mismatched semiconductor materials opens up access to a wide range of bandgaps and new device functionalities. However, it is inevitably accompanied by defect formation. A thorough analysis of how these defects propagate and interact with interfaces is critical to understanding their effects on device parameters. In this study, we present a comprehensive study of dislocation networks in the GaSb/GaAs heteroepitaxial system using transmission electron microscopy (TEM). Specifically, the sample analyzed is a GaSb film grown on GaAs using dislocation–reduction strategies such as interfacial misfit array formation and introduction of a dislocation filtering layer. Using various TEM techniques, it is shown that such an analysis can reveal important information on the dislocation behavior including filtering mechanism, types of dislocation reactions, and other interactions with interfaces. A novel method that enables plan-view imaging of deeply embedded interfaces using TEM and a demonstration of independent imaging of different dislocation types are also presented. While clearly effective in characterizing dislocation behavior in GaSb/GaAs, we believe that the methods outlined in this article can be extended to study other heteroepitaxial material systems.

36 MATERIALS SCIENCE↗

DR-RINS: Digital real-time relative intensity noise suppressor for pump–probe spectroscopy and microscopy

Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ~17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ~6 h to ~5 min in a real-time imaging scenario.

47 OTHER INSTRUMENTATION↗

Magnetic resonance force microscopy with matching frequencies of cantilever and spin

We have studied theoretically magnetic resonance force microscopy with a high-frequency nanomechanical cantilever when the cantilever frequency matches the resonant frequency of a single electron spin. Our analysis shows that in this situation, there is a small probability that the cantilever will oscillate with a large frequency shift. In conclusion, this can open new experimental opportunities for increasing the sensitivity in the detection of a single electron spin or even a single nuclear spin by using a high-frequency cantilever.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Piezoelectric property of PZT nanofibers characterized by resonant piezo-force microscopy

Nano-piezoelectric materials have drawn tremendous research interest. However, characterization of their piezoelectric properties, especially measuring the piezoelectric strain coefficients, remains a challenge. Normally, researchers use an AFM-based method to directly measure nano-materials’ piezoelectric strain coefficients. But, the extremely small piezoelectric deformation, the influence from the parasitic electrostatic force, and the environmental noise make the measurement results questionable. In this paper, a resonant piezo-force microscopy method was used to accurately measure the piezoelectric deformation from 1D piezoelectric nanofibers. During the experiment, the AFM tip was brought into contact with the piezoelectric sample and set to work at close to its first resonant frequency. A lock-in amplifier was used to pick up the sample’s deformation signal at the testing frequency. By using this technique, the piezoelectric strain constant d 33 of the Lead Zirconate Titanate (PZT) nanofiber with a diameter of 76 nm was measured. The result showed that d 33 of this PZT nanofiber was around 387 pm/V. Meanwhile, by tracking the piezoelectric deformation phase image, domain structures inside PZT nanofibers were identified.

36 MATERIALS SCIENCE↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

Deep-learning-aided extraction of optical constants in scanning near-field optical microscopy

Scanning near-field optical microscopy is one of the most effective techniques for spectroscopy of nanoscale systems. However, inferring optical constants from the measured near-field signal can be challenging because of a complicated and highly nonlinear interaction between the scanned probe and the sample. Conventional fitting methods applied to this problem often suffer from the lack of convergence or require human intervention. Here, we develop an alternative approach where the optical parameter extraction is automated by a deep learning network. The network provides an initial estimate that is subsequently refined by a traditional fitting algorithm. In conclusion, we show that this method demonstrates superior accuracy, stability against noise, and computational speed when applied to simulated near-field spectra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermally driven phase transition of halide perovskites revealed by big data-powered in situ electron microscopy

Halide perovskites are promising light-absorbing materials for high-efficiency solar cells, while the crystalline phase of halide perovskites may influence the device’s efficiency and stability. In this work, we investigated the thermally driven phase transition of perovskite (CsPbIxBr3—x), which was confirmed by electron diffraction and high-resolution transmission electron microscopy results. CsPbIxBr3—x transitioned from δ phase to α phase when heated, and the γ phase was obtained when the sample was cooled down. The γ phase was stable as long as it was isolated from humidity and air. A template matching-based data analysis method enabled visualization of the thermally driven phase evolution of perovskite during heating. Here, we also proposed a possible atomic movement in the process of phase transition based on our in situ heating experimental data. The results presented here may improve our understanding of the thermally driven phase transition of perovskite as well as provide a protocol for big-data analysis of in situ experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The magnetic states of a van der Waals ferromagnet CrGeTe 3 probed by vector-field magnetic force microscopy

Here, we present a study on the magnetic domain configuration in the van der Waals ferromagnet CrGeTe 3 using a vector-field cryogenic magnetic force microscopy. Our investigation demonstrates the influence of magnetic fields strength and angle on the magnetic domain configuration, showing the coexistence of striped and spike-like magnetic domains. This study contributes to understanding the impact of uniaxial magnetic anisotropy on the domain configuration of van der Waals ferromagnets, offering insights into stabilizing different domain patterns.

36 MATERIALS SCIENCE↗

Cooling rate dependence of charge density wave phases in 1 T -TaS 2 studied by scanning tunneling microscopy and x-ray diffraction

The role of dynamics in the charge density wave (CDW) phases of 1T-TaS 2 , especially in accessing metastable phases, is still under scrutiny. We investigated cooling rate dependence on low-temperature CDW phases in this material by scanning tunneling microscopy and x-ray diffraction. In the majority of cases, we found the typical low temperature commensurate CDW and identified no other differences between samples that were fast cooled vs slow cooled from room temperature. In rare cases (1/18 STM experiments and 1/30 XRD experiments), we found a multi-domain structure in the low temperature CDW. The domain structure and metallic behavior revealed by STM and STS measurements of this phase are in excellent agreement with the previously reported metallic mosaic CDW phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarization-dependent photoemission electron microscopy for domain imaging of inorganic and molecular materials

Polarization-dependent photoemission electron microscopy (PD-PEEM) exploits spatial variation in the optical selection rules of materials to image domain formation and material organization on the nanoscale. In this Perspective, we discuss the mechanism of PD-PEEM that results in the observed image contrast in experiments and provide examples of a wide range of material domain structures that PD-PEEM has been able to elucidate, including molecular and polymer domains, local electronic structure and defect symmetry, (anti)ferroelectricity, and ferromagnetism. As a result, we discuss challenges and new directions that are possible with this tool for probing domain structure in materials, including investigating the formation of transient ordered states, multiferroics, and the influence of molecular and polymer order and disorder on excited state dynamics and charge transport.

36 MATERIALS SCIENCE↗

Dark-field x-ray microscopy for 2D and 3D imaging of microstructural dynamics at the European x-ray free-electron laser

Dark field x-ray microscopy (DXFM) can visualize microstructural distortions in bulk crystals. Using the femtosecond x-ray pulses generated by x-ray free-electron lasers (XFELs), DFXM can achieve sub-μm spatial resolution and <100 fs time resolution simultaneously. In this paper, we demonstrate ultrafast DFXM measurements at the European XFEL to visualize an optically driven longitudinal strain wave propagating through a diamond single crystal. We also present two DFXM scanning modalities that are new to the XFEL sources: spatial 3D and 2D axial-strain scans with sub-μm spatial resolution. With this progress in XFEL-based DFXM, we discuss new opportunities to study multi-timescale spatiotemporal dynamics of microstructures.

47 OTHER INSTRUMENTATION↗

Modifications in the charge trap landscape in Hf 0.5 Zr 0.5 O 2 as a function of oxygen vacancy concentration observed with photoemission electron microscopy

Oxygen vacancies in Hf x Zr (1-x) O 2 (HZO) both contribute to stabilization of the ferroelectric orthorhombic phase and promote leakage pathways that limit the endurance of devices based on the material. Here, for this reason, the defect states of oxygen vacancies were investigated using photoemission electron microscopy (PEEM) and photoluminescence spectroscopy (PL), as their concentration was varied via ex situ laser exposure. Following a controlled oxygen vacancy reduction via visible (2.54 eV) laser dosing of HZO, deep-ultraviolet (DUV, 5.82 eV) PEEM was used to spatially probe the resulting mid-gap defect states and work function. Work function was found to increase monotonically with the laser-induced reduction in oxygen vacancy concentration culminating in a total increase near 70 meV. The change implies a Fermi level shift toward the valence band as the total available electron-filled charge states are reduced with the removal of oxygen vacancies. A reduction in charge states is corroborated by the observed lessening of both photoemission and photoluminescence intensities after laser dosing. The deduced position of the Fermi level is within a band of near-conduction band defect states produced by oxygen vacancies that are linked to endurance limiting leakage currents. Together, these results directly identify the primary role of oxygen vacancies on the defect states in HZO while demonstrating that laser exposure can be used for their modification.

42 ENGINEERING↗

Equation of state measurement of detonation carbon condensates using optical microscopy and interferometry

Thermochemical models of detonation that estimate performance (e.g., detonation velocity, energy delivery, etc.), are based on assumptions that carbon condensates (soot) formed during detonation is largely similar to bulk carbon. However, soot constituents can range from amorphous carbon to nanodiamond and include other material phases. Since thermodynamic properties of the soot such as compressibility are imperative for accurate thermochemical modeling of detonation reaction chemistry, experimental measurements of the equation of state (EOS) which determine the compressibility are vital. Due to the mixed-phase nature of detonation soot, typical methods to measure the EOS (e.g., x-ray diffraction) are untenable. In this study, the high-pressure EOS up to 20 GPa was determined for detonation soot collected from PBX 9502, Composition B (Comp B), Hexanitrostilbene (HNS), and LX-21 high explosives by employing a direct volume technique using optical microscopy and interferometry in a diamond anvil cell. Comp B soot was determined to be the least compressible [K 0 = 57.9(17) GPa] with HNS soot [K 0 = 53.7(15) GPa], LX-21 soot [K 0 = 45.8(51) GPa], and PBX 9502 soot [K 0 = 28.2(27) GPa] being more compressible, likely due to differences in nanodiamond content as compared to amorphous carbon and graphite content.

Amorphous materials↗

Interference microscopy study of the preplasma formed on an iron target surface exposed to high-power femtosecond laser pulses

The characteristic scale of spread of the plasma formed on the surface of a bulk iron target irradiated by a femtosecond laser pulse with an intensity of 10{sup 16} W cm{sup −2} is measured by time-resolved interference microscopy using femtosecond pulses emitted by a Cr : forsterite laser system with an intensity contrast of 10{sup 7}. The chosen technique is demonstrated to be efficient in such measurements. It is shown experimentally that, as a result of laser pulse impact, the displacement of a plasma layer with a density exceeding critical does not exceed 30 nm. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution deep view microscopy of cells and tissues

Methods, experimental setups and perspectives of three-dimensional deep view imaging microscopy of cell or tissue samples are reported. Preliminary biophysical and clinically relevant examples are presented. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗