Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mobile Measuring System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Comparison of methods for the NMR measurement of motionally averaged dipolar couplings

Motionally averaged dipolar couplings are an important tool for understanding the complex dynamics of catalysts, polymers, and biomolecules. While there is a plethora of solid-state NMR pulse sequences available for their measurement, in can be difficult to gauge the methods’ strengths and weaknesses. In particular, there has not been a comprehensive comparison of their performance in natural abundance samples, where 1H homonuclear dipolar couplings are important and the use of large MAS rotors may be required for sensitivity reasons. In this work, we directly compared some of the more common methods for measuring C–H dipolar couplings in natural abundance samples using L-alanine (L-Ala) and the N-formyl-L-methionyl-L-leucyl-L-phenylalanine (fMLF) tripeptide as model systems. Here, we evaluated their performance in terms of accuracy, resolution, sensitivity, and ease of implementation. We found that, despite the presence of 1H homonuclear dipolar interactions, all methods, with the exception of REDOR, were able to yield the reasonable dipolar coupling strengths for both mobile and static moieties. Of these methods, PDLF provides the most convenient workflow and precision at the expense of low sensitivity. In low-sensitivity cases, MAS-PISEMA and DIPSHIFT appear to be the better options.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deployable Cryocooler Based Cryomodule

Superconducting Radio Frequency (SRF) linear accelerators (linacs) have shown tremendous promise in extending the intensity frontier of particle accelerator technology. However, they are large and complex systems, requiring a central refrigeration system and complex piping to distribute liquid helium and nitrogen to the accelerating cavities. In response to these problems, RadiaBeam Technologies, LLC. proposes to develop a small mobile cryomodule that can be safely deployed to its planned field location. The scope of this work is to provide RadiaBeam with the specifications for a complete 650 MHz RF cavity model that can be incorporated into a compact SRF accelerator. Fermilab’s contribution will involve sharing contact resistance measurements, design parameters, and solid models. Design parameters will include the cavity frequency and gradient, length of the linac, number of cryocoolers, etc. This will ensure that the design is useful for practical linacs. A complete cryomodule design is envisioned. Radiabeam will design the cryomodule based on input from Fermilab’s experience on conduction cooling and the needs for a compact SRF accelerator.

43 PARTICLE ACCELERATORS↗

Landfill Emissions of Methane Inferred from Unmanned Aerial Vehicle and Mobile Ground Measurements

Municipal solid waste landfills are significant sources of atmospheric methane, the second most important greenhouse gas after carbon dioxide. Large emissions of methane from landfills contribute not only to global climate change, but also to local ozone formation due to the enhancement of radical chain lengths in atmospheric reactions of volatile organic compounds and nitrogen oxides. Several advanced techniques were deployed to measure methane emissions from two landfills in the Southeast Michigan ozone nonattainment area during the Michigan–Ontario Ozone Source Experiment (MOOSE). These techniques included mobile infrared cavity ringdown spectrometry, drone-mounted meteorological sensors and tunable diode laser spectrometry, estimation of total landfill emissions of methane based on flux plane measurements, and Gaussian plume inverse modeling of distributed methane emissions in the presence of complex landfill terrain. The total methane emissions measured at the two landfills were of the order of 500 kg/h, with an uncertainty of around 50%. The results indicate that both landfill active faces and leaking gas collection systems are important sources of methane emissions.

Olaguer, Eduardo P.↗

Airborne profiling of ice thickness using a short pulse radar

The acquisition and interpretation of ice thickness data from a mobile platform has for some time been a goal of the remote sensing community. Such data, once obtainable, is of value in monitoring the changes in ice thickness over large areas, and in mapping the potential hazards to traffic in shipping lanes. Measurements made from a helicopter-borne ice thickness profiler of ice in Lake Superior, Lake St. Clair and the St. Clair river as part of NASA's program to develop an ice information system are described. The profiler described is a high resolution, non-imaging, short pulse radar, operating at a carrier frequency of 2.7 GHz. The system can resolve reflective surfaces separated by as little as 10 cm. and permits measurement of the distance between resolvable surfaces with an accuracy of about 1 cm. Data samples are given for measurements both in a static (helicopter hovering), and a traverse mode. Ground truth measurements taken by an ice auger team traveling with the helicopter are compared with the remotely sensed data and the accuracy of the profiler is discussed based on these measurements.

Vickers, R. S.↗

Method of assessing a lipid-related health risk based on ion mobility analysis of lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

Benner, W Henry↗

Aerosol preparation of intact lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

60 APPLIED LIFE SCIENCES↗

Determining the risk of cardiovascular disease using ion mobility of lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

59 BASIC BIOLOGICAL SCIENCES↗

A Comprehensive Approach to Measure the Efficiency of Freight Transport: Freight Mobility Energy Productivity (F-MEP) Metric

Freight travel accounts for a major share of the energy consumed in the transportation sector in any country, and the United States is no exception. Understanding and modeling freight movement is critical, particularly in the context of capturing the impact of emerging technologies on freight travel and its externalities. The domain of freight modeling and forecasting is gaining pace in the recent years, but advancement in comprehensive freight performance metrics is still lagging. Conventional freight performance metrics such as truck-miles, ton-miles, or value-miles are unidimensional and aggregated in nature, making them unsuitable to accurately capture the impact of emerging transportation trends on the performance of freight systems. Addressing this research need, this paper presents the 'Freight Mobility Energy Productivity' metric to quantify freight performance of current as well as future freight systems, accounting for various costs associated with freight transport. The proposed metric was implemented using data from the Freight Analysis Framework along with other published sources, which shows intuitive results in quantifying freight performance. Further, a scenario analysis exercise was conducted to test the capability of the metric in tracking improvements in system-level freight efficiency as a result of vehicle powertrain technology improvement. Results of the scenario analysis reinforce confidence that the proposed metric can be used as a decision support tool in assessing the efficiency of existing as well as future freight trends and technologies.

25 ENERGY STORAGE↗

The solubility of NdPO 4 and DyPO 4 and stability of Nd and Dy chloride and hydroxyl complexes as a function of pH and salinity to 450 °C

The mobility of rare earth elements (REE) in geological systems is often controlled by the stability of monazite and xenotime, which are important hosts for the light and heavy REE. These REE phosphates constitute important resources and provide information on ore formation conditions and timing due to their uses as geothermometers and geochronometers. While the thermodynamic properties for these minerals are well-established up to high temperature and pressure, the properties for the aqueous REE complexes are not well constrained with limited information up to 300 °C. In this study, the solubility of synthetic NdPO 4 and DyPO 4 endmembers were measured in hydrothermal sub- to supercritical NaCl-bearing aqueous solutions from 350 at saturated water vapor pressure to 450 °C at 700 bar. The speciation of Nd and Dy was determined in acidic to alkaline solutions (pH 25 °C values from 2 to 10), and indicates that the hydroxyl species REE(OH) 2 + and REE(OH) 3 0 predominate at low salinity (0.01 mol/kg NaCl) with some contribution of REE chloride species REECl 2+ and REECl 2 + in acidic fluids. The REE phosphate solubility measured in these experiments is up to two orders of magnitude higher than predicted using existing thermodynamic properties from literature for aqueous species extrapolated from lower temperature data to supercritical conditions. To address this discrepancy, the thermodynamic properties of the REE aqueous species were optimized using GEMSFITS to derive the formation constants for the REE chloride (β Cl ) and hydroxyl (β OH ) complexes in the studied temperature range. This study highlights the importance of the hydroxyl species REE(OH) 2 + and REE(OH) 3 0 over a wide range of pH and temperature. As a result, the revised thermodynamic properties for Dy and Nd chloride and hydroxyl species more accurately predict the solubility of NdPO 4 and DyPO 4 and provide insight into the speciation and mobility of the light and heavy REE in hydrothermal supercritical fluids in the crust.

58 GEOSCIENCES↗

Evaluation of assumptions made by Hygroscopic Tandem Differential Mobility Analyzer inversion routines

The Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA) measures the hygroscopicity of atmospheric particles, and many atmospheric processes that change this hygroscopicity also change the atmospheric size distribution. Two assumptions made during H-TDMA inversion create spurious hygroscopic trends as a function of the changing inlet size distribution. These two assumptions—that the particles exiting the first Differential Mobility Analyzer (DMA1) are singly charged and that the inlet size distribution has a slope of zero (flat)— generate Multi-Charge Dispersion (MCD) bias and Slope bias, respectively. First, we use a model, named TAO, to show that the inlet size distribution could theoretically change the measured ammonium sulfate hygroscopicity by 10%–20% as a function of diameter or experimental time with no change in relative humidity. Secondly, we show experimentally that aerosol emitted from the flaming combustion of grass creates MCD bias. Here, in this experiment, we measure the CPC response of the first three charges and invert these responses using a new routine named Junior. Junior's inversion of each charge shows that one growth factor distribution describes all measured diameters (no growth dependence on diameter). As in the modeling study above, previous publications of this aerosol system, using traditional inversion assumptions, report a decrease in hygroscopicity as DMA1 diameter increases. Unlike traditional inversions, Junior's inversion does not assume the particles are singly charged nor does it make the flat inlet size distribution assumption. Instead, both the inlet size distribution and each charge's CPC response are measured quantities. Thus, the discrepancy between our inversion results and previous publications is likely due to the traditional inversion routine assumptions. This underscores the importance for accounting for Slope and MCD bias during inversions. Experimental results should be carefully analyzed when reporting hygroscopic trends with respect to diameter or experimental time when using the traditional inversion assumptions.

42 ENGINEERING↗

Sticky roots--implications of widespread, cryptic, viral infection of plants in natural and managed ecosystems for soil carbon processing in the rhizosphere

Plants strongly influence soil properties through rhizodeposition, in which exudates diffuse from roots, additional secretions are actively released, and root cells are sloughed into the soil. This contribution by plants of carbon compounds belowground is at the core of soil health, water holding capacity, and the soil carbon storage that pulls carbon dioxide out of the atmosphere. Once in soil, organic matter can bind with minerals such as iron hydroxides, where it can be protected from microbial attack for millenia, preserving very large terrestrial soil carbon pools. However, those same compounds contributed by roots to soil may also destabilize the long-term protective associations of SOM with minerals, making that soil organic matter (SOM) more vulnerable to microbial attack and decomposition. Plant roots thus influence both the buildup and breakdown of soil carbon pools. DOE’s E3SM Land Model (ELM) includes a representation of soil carbon storage on minerals, but the potential vulnerability of SOM–mineral associations to effects of rhizodeposition is not yet represented in ELM. To begin testing for this effect of rhizodeposition on soil carbon storage and decomposition, we worked to develop a novel approach during this TES Exploratory project DE-SC0019142 – we harnessed the power of plant viral infection. We examined whether plant virus infection can serve as a tool to intensify rhizodeposition at the root surface, and therefore possibly intensify mobilization of SOM from minerals making it visible to our analytical techniques. Viral infection is widespread in terrestrial ecosystems; 25-70% of plants have virus infection, yet the influence of such infection on root traits and terrestrial soil carbon dynamics remains largely unexplored. We used two plant hosts: the annual Avena sativa (oats) and the genetically tractable, model grass Brachypodium distachyon. These grasses were infected with the broad host range virus Barley Yellow Dwarf Virus (BYDV) via aphids (Rhopalosiphum padi). BYDV infects at least 150 grass species in agricultural and natural ecosystems, and in previous experiments, oats infected with BYDV had roots that were very sticky to the touch, strongly suggesting that infection altered rhizodeposition. We developed this new experimental approach mostly in a one virus (Barley Yellow Dwarf Virus)–one plant (Avena sativa) system. (Several effects of infection in a Brachypodium-BYDV system were similar in nature to effects on Avena sativa, but were more variable.) In the BYDV-Avena system, we developed protocols for consistently infecting target plants (and avoiding infection of control plants) using aphid caging on leaves. We measured that infected plants exhibited reduced photosynthesis, plant (including root) biomass, and root:shoot ratio, as well as simplified root system architecture. We established procedures for sampling the organic compounds carried specifically in phloem (vascular tissue) of leaves and roots, using aphid stylectomy. We used FTICR-MS, Orbitrap GC-MS, and LC-MS/MS to analyze organic compounds in phloem, liquid around roots of plants grown hydroponically, and pore water around roots in soil, and found differences in the compounds in solution bathing roots when infected and uninfected plants were grown hydroponically. Finally, we synthesized isotopically-labeled mineral–organic matter (MAOM) associations in the lab and developed assays using them in solution and in soil. Assays quantified the extent and rate of mineralization of labeled MAOM that was mobilized by functionally distinct rhizodeposits and then attacked by microbes. Two mechanisms for MAOM mobilization emerged, with distinct dynamics. During “direct” mobilization, rhizodeposits such as the strong ligand oxalic acid could drive rapid dissolution of minerals, mobilizing MAOM. During “indirect” mobilization, rhizodeposits such as the simple sugar glucose did not attack minerals directly but instead intensified microbial activity, which led to mobilization via changes in e.g. pH, Eh, and microbial metabolite production (Li et al. 2021). Mechanistic understanding derived from these data and our ongoing experiments using these techniques will inform future development of ELM. Plant roots not only contribute newly fixed organic compounds to soils, but also root activities can drive mineralization of the carbon and nutrients mobilized off minerals via “indirect” or “direct” mechanisms. Using viral infection as a new tool, ongoing combined experimentation and modeling will explore the strength and larger-scale significance of the cascade of processes from rhizodeposition to MAOM mobilization for soil carbon storage and nutrient cycling in terrestrial ecosystems. And if viral infection leads quite generally to “sticky roots”, our perception of the potential importance of prevalent virus infection in terrestrial landscapes will be transformed.

54 ENVIRONMENTAL SCIENCES↗

Quantum Hall Effect Measurement of Spin–Orbit Coupling Strengths in Ultraclean Bilayer Graphene/WSe 2 Heterostructures

Here, we study proximity-induced spin–orbit coupling (SOC) in bilayer graphene/few-layer WSe 2 heterostructure devices. Contact mode atomic force microscopy (AFM) cleaning yields ultraclean interfaces and high-mobility devices. In a perpendicular magnetic field, we measure the quantum Hall effect to determine the Landau level structure in the presence of out-of-plane Ising and in-plane Rashba SOC. A distinct Landau level crossing pattern emerges when tuning the charge density and displacement field independently with dual gates, originating from a layer-selective SOC proximity effect. Analyzing the Landau level crossings and measured inter-Landau level energy gaps yields the proximity-induced SOC energy scale. The Ising SOC is ~2.2 meV, 100 times higher than the intrinsic SOC in graphene, whereas its sign is consistent with theories predicting a dependence of SOC on interlayer twist angle. The Rashba SOC is ~15 meV. Finally, we infer the magnetic field dependence of the inter-Landau level Coulomb interactions. These ultraclean bilayer graphene/WSe 2 heterostructures provide a high mobility system with the potential to realize novel topological electronic states and manipulate spins in nanostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical review of gamma spectrometry detection approaches for in-plant surface deposition monitoring

Surface deposition of activated corrosion product on oxide layers of light-water reactor primary system components is the primary source for ex-core radiation fields and personnel radiation exposure. Understanding the deposition mechanism and what factors influence the deposition and release behaviors are crucial for developing effective radiation field reduction measures. One of the available tools to assess the surface deposition is in-plant gamma spectrometry, which has been performed for several decades using either sodium iodide (NaI) or high-purity germanium (HPGe) detectors. Lately, the much more mobile cadmium-zinc-telluride (CZT) detectors are increasingly employed by stations because of their ease in use and handling. However, all of these gamma detectors face the same challenges; namely large-geometry samples of inconsistent sample compositions and sometimes gaps in the information necessary to establish proper efficiency calibrations. This paper reviews current measurements and efficiency calibration approaches taken in the industry. The validity of the measurement results and the feasibility of the data's use in understanding source term behavior is examined. Suggestions are made for the development of a more robust deposit characterization and radiation field monitoring program. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Predictive momentum management for a space station measurement and computation requirements

An analysis is made of the effects of errors and uncertainties in the predicting of disturbance torques on the peak momentum buildup on a space station. Models of the disturbance torques acting on a space station in low Earth orbit are presented, to estimate how accurately they can be predicted. An analysis of the torque and momentum buildup about the pitch axis of the Dual Keel space station configuration is formulated, and a derivation of the Average Torque Equilibrium Attitude (ATEA) is presented, for the case of no MRMS (Mobile Remote Manipulation System) motion, Y vehicle axis MRMS motion, and Z vehicle axis MRMS motion. Results showed the peak momentum buildup to be approximately 20000 N-m-s and to be relatively insensitive to errors in the predicting torque models, for Z axis motion of the MRMS was found to vary significantly with model errors, but not exceed a value of approximately 15000 N-m-s for the Y axis MRMS motion with 1 deg attitude hold error. Minimum peak disturbance momentum was found not to occur at the ATEA angle, but at a slightly smaller angle. However, this minimum peak momentum attitude was found to produce significant disturbance momentum at the end of the predicting time interval.

Adams, John Carl↗

Flexible Electronics toward Wearable Sensing

Wearable sensors play a crucial role in realizing personalized medicine, as they can continuously collect data from the human body to capture meaningful health status changes in time for preventive intervention. However, motion artifacts and mechanical mismatches between conventional rigid electronic materials and soft skin often lead to substantial sensor errors during epidermal measurement. Because of its unique properties such as high flexibility and conformability, flexible electronics enables a natural interaction between electronics and the human body. Here, we summarize our recent studies on the design of flexible electronic devices and systems for physical and chemical monitoring. Material innovation, sensor design, device fabrication, system integration, and human studies employed toward continuous and noninvasive wearable sensing are discussed. A flexible electronic device typically contains several key components, including the substrate, the active layer, and the interface layer. The inorganic-nanomaterials-based active layer (prepared by a physical transfer or solution process) is shown to have good physicochemical properties, electron/hole mobility, and mechanical strength. Flexible electronics based on the printed and transferred active materials has shown great promise for physical sensing. For example, integrating a nanowire transistor array for the active matrix and a conductive pressure-sensitive rubber enables tactile pressure mapping; tactile-pressure-sensitive e-skin and organic light-emitting diodes can be integrated for instantaneous pressure visualization. Such printed sensors have been applied as wearable patches to monitor skin temperature, electrocardiograms, and human activities. In addition, liquid metals could serve as an attractive candidate for flexible electronics because of their excellent conductivity, flexibility, and stretchability. Liquid-metal-enabled electronics (based on liquid-liquid heterojunctions and embedded microchannels) have been utilized to monitor a wide range of physiological parameters (e.g., pulse and temperature). Despite the rapid growth in wearable sensing technologies, there is an urgent need for the development of flexible devices that can capture molecular data from the human body to retrieve more insightful health information. We have developed a wearable and flexible sweat-sensing platform toward real-time multiplexed perspiration analysis. An integrated iontophoresis module on a wearable sweat sensor could enable autonomous and programmed sweat extraction. A microfluidics-based sensing system was demonstrated for sweat sampling, sensing, and sweat rate analysis. Roll-to-roll gravure printing allows for mass production of high-performance flexible chemical sensors at low cost. These wearable and flexible sweat sensors have shown great promise in dehydration monitoring, cystic fibrosis diagnosis, drug monitoring, and noninvasive glucose monitoring. Future work in this field should focus on designing robust wearable sensing systems to accurately collect data from the human body and on large-scale human studies to determine how the measured physical and chemical information relates to the individual's specific health conditions. Further research in these directions, along with the large sets of data collected via these wearable and flexible sensing technologies, will have a significant impact on future personalized healthcare.

47 OTHER INSTRUMENTATION↗

Presound: UAV Diagnostic System Enabled by Vibration-Based Machine Learning

A low-weight, inexpensive small unmanned aerial system (sUAS) that takes off, performs a mission, lands, and safely stows and recharges itself has myriad future applications ranging from agricultural imaging to last-mile package delivery. Likewise, Urban Air Mobility (UAM) systems will enable people to take air taxis from point to point in cities, rapidly moving commuters long distances without concern for road traffic and congestion. Fully electric aviation systems will be cleaner and quieter than ground transport. Cities could eliminate cars and buses, and convert roads to higher capacity bike and pedestrian throughways. Yet, for sUAS as well as UAM, system reliability and assurance is a limiting factor to deploying affordable autonomous flight systems. For this bright future of aviation to be realized, aircraft must be able to autonomously and accurately self-diagnose health issues both before takeoff and during flight. The GreenSight PreSound system is designed to identify defects on aircraft through intelligent analysis of vibration. It accomplishes this by measuring structural vibrations induced by the vehicle’s own propellers, and analyzing that data using a machine learning model that determines whether a defect is present. The PreSound system is designed to require no human oversight, and to operate across a wide array of vehicles through re-training of the model for each target aircraft. PreSound has been developed and seen limited early success using data collected from the GreenSight Dreamer sUAS, a 5lb quadrotor vehicle designed for aerial imaging applications. The final detection model, trained on data with props spinning at 50% throttle, achieves excellent performance with over 99% average accuracy in detecting blade damage using a single FFT vector input. It demonstrates the ability to generalize to new types of blade damage, correctly classifying a different type of blade damage with 98% accuracy. Full test pulses were classified with 100% accuracy, and in live testing, all sets of data during blade movement were classified accurately with over 95% confidence. When trained on in-flight data, the same model achieves an average accuracy of 85% in distinguishing between undamaged and blade-damaged states in flight. The authors believe that these accuracies show significant potential of this approach to expand unmanned flight safety, with significant potential benefits in accelerating Advanced Aerial Mobility (AAM) and UAM aviation applications.

UAS↗

Real-time Shape-based Particle Separation and Detailed In-situ Particle Shape Characterization

Particle shape is an important attribute that is very difficult to characterize. We present a new portable system that offers, for the first time, the opportunity to separate particles with different shapes and characterize their chemical and physical properties, including their dynamic shape factors (DSFs) in the transition and free-molecular regimes, with high precision, in-situ, and in real-time. The system uses a new generation aerosol particle mass analyzer (APM) to classify particles based on their masses and transport them to a differential mobility analyzer (DMA) that is used to select particles of one charge, one mass, and one shape. These highly uniform particles are ready for use and/or characterization by any application or analytical tool. We combine APM and DMA with our single particle mass spectrometer, SPLAT II, to form the ADS, and demonstrate its utility to measure in real-time individual particle compositions and vacuum aerodynamic diameters to yield, for each selected shape, particle DSFs in two flow regimes. We apply the ADS to characterize aspherical ammonium sulfate and NaCl particles and show that both particle types have wide distribution of particle shapes with DSFs from nearly 1 to 1.5.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗