Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Thoughts on Sensitivity Analysis and Uncertainty Propagation Methods with Respect to the Prompt Fission Neutron Spectrum Impact on Critical Assemblies

The prompt fission neutron spectrum (PFNS) uncertainties in the n+{sup 239}Pu fission reaction are used to study the impact on several fast critical assemblies modeled in the MCNP6.1 code. The newly developed sensitivity capability in MCNP6.1 is used to compute the k{sub eff} sensitivity coefficients with respect to the PFNS. In comparison, the covariance matrix given in the ENDF/B-VII.1 library is decomposed and randomly sampled realizations of the PFNS are propagated through the criticality calculation, preserving the PFNS covariance matrix. The information gathered from both approaches, including the overall k{sub eff} uncertainty, is statistically analyzed. Overall, the forward and backward approaches agree as expected. The results from a new method appear to be limited by the process used to evaluate the PFNS and is not necessarily a flaw of the method itself. Final thoughts and directions for future work are suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CMB bispectrum, trispectrum, non-Gaussianity, and the Cramer-Rao bound

Minimum-variance estimators for the parameter f{sub nl} that quantifies local-model non-Gaussianity can be constructed from the cosmic microwave background (CMB) bispectrum (three-point function) and also from the trispectrum (four-point function). Some have suggested that a comparison between the estimates for the values of f{sub nl} from the bispectrum and trispectrum allow a consistency test for the model. But others argue that the saturation of the Cramer-Rao bound--which gives a lower limit to the variance of an estimator--by the bispectrum estimator implies that no further information on f{sub nl} can be obtained from the trispectrum. Here, we elaborate the nature of the correlation between the bispectrum and trispectrum estimators for f{sub nl}. We show that the two estimators become statistically independent in the limit of large number of CMB pixels, and thus that the trispectrum estimator does indeed provide additional information on f{sub nl} beyond that obtained from the bispectrum. We explain how this conclusion is consistent with the Cramer-Rao bound. Our discussion of the Cramer-Rao bound may be of interest to those doing Fisher-matrix parameter-estimation forecasts or data analysis in other areas of physics as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Availability of Neutronics Benchmarks in the ICSBEP and IRPhEP Handbooks for Computational Tools Testing

In the past several decades, numerous experiments have been performed worldwide to support reactor operations, measurements, design, and nuclear safety. Those experiments represent an extensive international investment in infrastructure, expertise, and cost, representing significantly valuable resources of data supporting past, current, and future research activities. Those valuable assets represent the basis for recording, development, and validation of our nuclear methods and integral nuclear data [1]. The loss of these experimental data, which has occurred all too much in the recent years, is tragic. The high cost to repeat many of these measurements can be prohibitive, if not impossible, to surmount. Two international projects were developed, and are under the direction of the Organisation for Co-operation and Development Nuclear Energy Agency (OECD NEA) to address the challenges of not just data preservation, but evaluation of the data to determine its merit for modern and future use. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) was established to identify and verify comprehensive critical benchmark data sets; evaluate the data, including quantification of biases and uncertainties; compile the data and calculations in a standardized format; and formally document the effort into a single source of verified benchmark data [2]. Similarly, the International Reactor Physics Experiment Evaluation Project (IRPhEP) was established to preserve integral reactor physics experimental data, including separate or special effects data for nuclear energy and technology applications [3]. Annually, contributors from around the world continue to collaborate in the evaluation and review of select benchmark experiments for preservation and dissemination. The extensively peer-reviewed integral benchmark data can then be utilized to support nuclear design and safety analysts to validate the analytical tools, methods, and data needed for next-generation reactor design, safety analysis requirements, and all other front- and back-end activities contributing to the overall nuclear fuel cycle where quality neutronics calculations are paramount.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reactivity Coefficient Measurements and Sensitivity Studies [Abstract]

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor (k eff ). K eff is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while k eff is a well-documented parameter with detailed sensitivity and uncertainty analysis, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific nuclear data by optimally designing experiments that are sensitive to a suite of measurement parameters beyond k eff . By identifying how each parameter's nuclear data sensitivity differs from others, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes reactivity coefficient sensitivities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A 2011 Updated Systematic Review and Clinical Practice Guideline for the Management of Malignant Extradural Spinal Cord Compression

Purpose: To update the 2005 Cancer Care Ontario practice guidelines for the diagnosis and treatment of adult patients with a suspected or confirmed diagnosis of extradural malignant spinal cord compression (MESCC). Methods: A review and analysis of data published from January 2004 to May 2011. The systematic literature review included published randomized control trials (RCTs), systematic reviews, meta-analyses, and prospective/retrospective studies. Results: An RCT of radiation therapy (RT) with or without decompressive surgery showed improvements in pain, ambulatory ability, urinary continence, duration of continence, functional status, and overall survival. Two RCTs of RT (30 Gy in eight fractions vs. 16 Gy in two fractions; 16 Gy in two fractions vs. 8 Gy in one fraction) in patients with a poor prognosis showed no difference in ambulation, duration of ambulation, bladder function, pain response, in-field failure, and overall survival. Retrospective multicenter studies reported that protracted RT schedules in nonsurgical patients with a good prognosis improved local control but had no effect on functional or survival outcomes. Conclusions: If not medically contraindicated, steroids are recommended for any patient with neurologic deficits suspected or confirmed to have MESCC. Surgery should be considered for patients with a good prognosis who are medically and surgically operable. RT should be given to nonsurgical patients. For those with a poor prognosis, a single fraction of 8 Gy should be given; for those with a good prognosis, 30 Gy in 10 fractions could be considered. Patients should be followed up clinically and/or radiographically to determine whether a local relapse develops. Salvage therapies should be introduced before significant neurologic deficits occur.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Loss-of-Offsite-Power Events: Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2020, while the most recent 15-year data (i.e., from 2006–2020) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather related. Highly significant decreasing trends in the LOOP occurrence rates were identified for All-LOOPs during critical operation (p-value = 0.001) and switchyard-centered LOOPs during critical operation (p-value = 0.002) for the most recent 10-year period (2011–2020). Adverse trends in LOOP durations continue for switchyard-centered LOOPs (p-value = 0.005), All-LOOPs (p-value = 0.019), as well as All-LOOPs during shutdown operation (p-value = 0.003). Statistical tests show the LOOP counts are not uniformly distributed across the 12 months, and variation among the months exists for plant-centered LOOPs (p-value = 0.028), grid-related LOOPs (p-value = 0.021), All-LOOPs (p-value = 0.003), and All-LOOPs during critical operation (p-value = 0.008). The engineering analysis of LOOP data showed for the period of 2006–2020, the equipment failure events were dominated by failures of circuits and relay; human errors have been less frequent and occurred primarily in maintenance; and weather events were dominated by tornadoes and lightning.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

n lowbar TOF Experiment: Past, Present And Future

The neutron Time-of-Flight facility at CERN was built to measure the neutron capture and fission cross sections. A short description of the facility, the detectors and the data analysis techniques will be illustrated. A short review of the preliminary results on the fission cross sections is presented together with the implications in fundamental nuclear physics and in nuclear technologies. Future perspectives both for the experimental campaign and for the upgrade of the facility are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of {nu}{sub e}-electron scattering cross section with a CsI(Tl) scintillating crystal array at the Kuo-Sheng nuclear power reactor

The {nu}{sub e}-e{sup -} elastic scattering cross section was measured with a CsI(Tl) scintillating crystal array having a total mass of 187 kg. The detector was exposed to an average reactor {nu}{sub e} flux of 6.4x10{sup 12} cm{sup -2} s{sup -1} at the Kuo-Sheng Nuclear Power Station. The experimental design, conceptual merits, detector hardware, data analysis, and background understanding of the experiment are presented. Using 29882/7369 kg-days of Reactor ON/OFF data, the standard model (SM) electroweak interaction was probed at the squared 4-momentum transfer range of Q{sup 2{approx}}3x10{sup -6} GeV{sup 2}. The ratio of experimental to SM cross sections of {xi}=[1.08{+-}0.21(stat){+-}0.16(sys)] was measured. Constraints on the electroweak parameters (g{sub V},g{sub A}) were placed, corresponding to a weak mixing angle measurement of sin{sup 2{theta}}{sub W}=0.251{+-}0.031(stat){+-}0.024(sys). Destructive interference in the SM {nu}{sub e}-e process was verified. Bounds on anomalous neutrino electromagnetic properties were placed: neutrino magnetic moment at {mu}{sub {nu}{sub e}}<2.2x10{sup -10} {mu}{sub B} and the neutrino charge radius at -2.1x10{sup -32} cm{sup 2}<<r{sub {nu}}{sub e}{sup 2}><3.3x10{sup -32} cm{sup 2}, both at 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-545: MLC Distance Travelled as a Predictor for Motor Failure

Purpose: To study the frequency of Multi-Leaf Collimator (MLC) leaf failures, investigate methods to predict them and reduce linac downtime. Methods: A Varian HD120 MLC was used in our study. The hyperterminal MLC errors logged from 06/2012 to 12/2014 were collected. Along with the hyperterminal errors, the MLC motor changes and all other MLC interventions by the linear accelerator engineer were recorded. The MLC dynalog files were also recorded on a daily basis for each treatment and during linac QA. The dynalog files were analyzed to calculate root mean square errors (RMS) and cumulative MLC travel distance per motor. An in-house MatLab code was used to analyze all dynalog files, record RMS errors and calculate the distance each MLC traveled per day. Results: A total of 269 interventions were recorded over a period of 18 months. Of these, 146 included MLC motor leaf change, 39 T-nut replacements, and 84 MLC cleaning sessions. Leaves close to the middle of each side required the most maintenance. In the A bank, leaves A27 to A40 recorded 73% of all interventions, while the same leaves in the B bank counted for 52% of the interventions. On average, leaves in the middle of the bank had their motors changed approximately every 1500m of travel. Finally, it was found that the number of RMS errors increased prior to an MLC motor change. Conclusion: An MLC dynalog file analysis software was developed that can be used to log daily MLC usage. Our eighteen-month data analysis showed that there is a correlation between the distance an MLC travels, the RMS and the life of the MLC motor. We plan to use this tool to predict MLC motor failures and with proper and timely intervention, reduce the downtime of the linac during clinical hours.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of the MCU precision code and ROSFOND neutron data in application to the calculations of criticality of fast reactors with highly enriched uranium

Calculation of 335 critical assemblies (benchmark experiments) with the core of highly enriched uranium and reflectors of various materials is performed. The statistical analysis of the results shows that, for all 16 materials studied, the absolute value of the most probable deviation of the calculated value of K{sub eff} from the experimental one does not exceed 0.005.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uncertainty in unprotected loss-of-heat-sink, loss-of-flow, and transient-overpower accidents.

The sensitivities of various output parameters to selected input parameters in unprotected combined loss of heat-sink and loss-of-flow (ULOHS), loss-of-flow (ULOF), and transient-overpower (UTOP) accidents are explored in this report. This line of investigation was suggested by R. A. Wigeland. For an initial examination of potential sensitivities, the MATWS computer program has been compiled as part of a dynamic link library (DLL) so that uncertain input parameters can be sampled from their probability distributions using the GoldSim simulation software. The MATWS program combines the point-kinetics module from the SAS4A/SASSYS computer code with a simplified representation of the reactor heat removal system. Coupling with the GoldSim software by means of a DLL not only provides a convenient mechanism for sampling the stochastic input parameters but also allows the use of various tools that are available in GoldSim for analyzing the dependence of various MATWS outputs on these parameters. Should a decision be made to continue this investigation, the techniques used to couple MATWS and GoldSim could also be applied to couple the SAS4A/SASSYS computer code with GoldSim. The work described here illustrates the type of results that can be obtained from the stochastic analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exclusive Measurements of Breakup Reactions in the {sup 7}Li+{sup 144}Sm System

Breakup reactions induced by a 30 MeV {sup 7}Li beam on a {sup 144}Sm target were measured through the coincident detection of the light particles emitted in the reaction plane. The emphasis of the measurements and data analysis was placed in the complete characterization of the reaction by means of the identification of the breakup products and the experimental extraction of the physically relevant magnitudes. The coincident yield of the emitted light particles was compared with the results of kinematical calculations that were done assuming different distributions for these magnitudes and taking into account the geometric response of the detection system. The results of this comparison indicate in all cases a clear dominance of a process compatible with the breakup of {sup 6}Li through the 3{sup +} resonant state at 2.186 MeV following one-neutron transfer from the projectile to the target, over the breakup of the projectile itself. Relative cross sections as a function of the emission angle of the {sup 6}Li and the in-plane anisotropy of the subsequent emission of breakup products were extracted from the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of the PHDS Germanium Gamma-ray Imager (GeGI) in Facility Decontamination Assessment - 19471

As part of a site wide investigation, U.S. EPA Region 5 had to assess the nature and extent of contamination in a former radioactive source manufacturing facility. This work involved verification of the radioisotope expected, ensuring no other radioisotopes were present, and quantification of the activity and areal extent of contamination throughout the facility. The device used to support this assessment work was the Germanium Gamma-ray Imager (GeGI) manufactured by PHDS Co. of Knoxville, Tennessee. GeGI is a germanium-semiconductor imaging detector system that provides identification, location, and quantification of radioactive materials within its field of view. GeGI provides the highest fidelity radiological assay information including the best gamma-ray energy resolution and spatial localization of any existing technology, including gamma-ray energy resolution of ∼0.3% full-width half-max (FWHM) at 662 keV and angular location resolution ∼ +/-1 degree. The GeGI is a mechanically cooled, portable system well-suited to field operations. PHDS Co. also provided on-site support during assessment operations and performed subsequent data analysis. Gamma-ray spectral data and associated images were collected with GeGI in six primary areas of the facility having significant residual contamination. A total of 61 gamma-ray spectrum/image sets were collected over the course of three working days (22 Compton images and 39 Pinhole/Compton images). During data collection, Compton imaging was used as the means by which to identify and prioritize hotspots. After contaminated regions were identified via Compton imaging, short-distance Pinhole spectrum/image sets were collected for additional analysis. All of the spectrum/image sets were analyzed to determine the radioisotope distribution within the GeGI field of view, as well as to provide an estimate of the activity associated with each hotspot. It was determined that the nature of residual contamination present was distributed across specific areas of elevated activity, where in some areas there was significant accumulation of contaminated material. It was also determined that no discrete sources of high-activity were present, as would be expected in the case of radioactive material product intended for sealed source manufacture. Results included the activity of residual contamination for each of the areas assessed, and an estimate of the physical area over which that contamination was distributed. It was anticipated by EPA that if decontamination were to be performed that it would involve some type of concrete scabbling or other means of physical removal of contaminated material. The GeGI data could be used to estimate the areal extent (square footage) of concrete removal that would be required for decontamination. Using the activity estimate data from the GeGI along with an estimated depth of concrete removal, planning could be performed for decontamination work (equipment and personnel), waste collection, packaging, transportation, and disposal, along with an associated cost estimate. With regard to health and safety, use of the GeGI reduced the radiation dose to the EPA R5 staff performing the assessment work. The GeGI is a non-destructive device that supports assessment of radioactively contaminated areas and sources from a distance, reducing the need for close contact to radiation, and the time necessary for personnel to operate near such hazards. Use of the GeGI in this facility assessment was our first attempt to apply this technology in what proved to be a quick and efficient decontamination assessment method. The GeGI can assess the nature and extent of residual contamination in a facility, first by quickly identifying the areas of elevated activity, followed by refined measurement and assessment of those elevated areas. The GeGI data can then be used to develop planning and a cost estimate of required decontamination and waste management activities. Since it's a non-destructive gamma identification and imaging device, it can reduce the distance of workers from radioactive sources and the dose incurred from assessment work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PROVIDING PLANT DATA ANALYTICS THROUGH A SEAMLESS DIGITAL ENVIRONMENT

As technology continues to evolve and become more integrated into a worker’s daily routine in the Nuclear Power industry the need for easy access to data becomes a priority. Not only does the need for data increase but the amount of data collected increases. In most cases the data is collected and stored in various software applications, many of which are legacy systems, which do not offer any other option to access the data except through the application’s user interface. Furthermore the data gets grouped in “silos” according to work function and not necessarily by subject. Hence, in order to access all the information needed for a particular task or analysis one may have to access multiple applications to gather all the data needed. The industry and the research community have identified the need for a digital architecture and more importantly the need for a Seamless Digital Environment. An SDE provides a means to access multiple applications, gather the data points needed, conduct the analysis requested, and present the result to the user with minimal or no effort by the user. In addition, the nuclear utilities have identified the need for research focused on data analytics. The effort should develop and evaluate use cases for data mining and analytics for employing information from plant sensors and database for use in developing improved business analytics. Idaho National Laboratory is leading such effort, which is conducted in close collaboration with vendors, nuclear utilities, Institute of Nuclear Power Operations, and Electric Power Research Institute. The goal of the study is to research potential approaches to building an analytics solution for equipment reliability, on a small scale, focusing on either a single piece of equipment or a single system. The analytics solution will likely consist of a data integration layer, predictive and machine learning layer and the user interface layer that will display the output of the analysis in a straight forward, easy to consume manner. This paper will describe the study and the initial results.

47 OTHER INSTRUMENTATION↗

Deuterium-tritium neutron yield measurements with the 4.5 m neutron-time-of-flight detectors at NIF

The first several campaigns of laser fusion experiments at the National Ignition Facility (NIF) included a family of high-sensitivity scintillator/photodetector neutron-time-of-flight (nTOF) detectors for measuring deuterium-deuterium (DD) and DT neutron yields. The detectors provided consistent neutron yield (Y{sub n}) measurements from below 10{sup 9} (DD) to nearly 10{sup 15} (DT). The detectors initially demonstrated detector-to-detector Y{sub n} precisions better than 5%, but lacked in situ absolute calibrations. Recent experiments at NIF now have provided in situ DT yield calibration data that establish the absolute sensitivity of the 4.5 m differential tissue harmonic imaging (DTHI) detector with an accuracy of {+-}10% and precision of {+-}1%. The 4.5 m nTOF calibration measurements also have helped to establish improved detector impulse response functions and data analysis methods, which have contributed to improving the accuracy of the Y{sub n} measurements. These advances have also helped to extend the usefulness of nTOF measurements of ion temperature and downscattered neutron ratio (neutron yield 10-12 MeV divided by yield 13-15 MeV) with other nTOF detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification and Validation of START: A Spent Nuclear Fuel Routing and Decision Support Tool

The Stakeholder Tool for Assessing Radioactive Transportation (START) is a web-based geospatial decision-support tool being developed by the US Department of Energy’s Office of Integrated Waste Management (IWM) to support federal interim storage for spent nuclear fuel (SNF) and associated transportation. START provides many functions for the IWM program including: serving as a communications tool for conveying geospatial data and information, an options analysis tool for exploring potential transport modes and routes for transporting SNF from nuclear power plants to future federal interim storage facilities, an emergency response planning tool for Tribes and States to identify training needs along potential SNF transport corridors, an environmental analysis tool for estimating potential radiation dose exposure from incident-free and incident-case SNF transport conditions, and a systems analysis support tool providing route-related inputs for system throughput analysis. As part of the START development process, a verification and validation (V&V) effort is being undertaken. In the initial V&V phase, several outputs of the START tool were checked such as the total distance, population and population densities within the buffer zone, and incident free dose. The V&V process is fluid as it will be utilized after each version change to ensure that the core functionalities of the tool are maintained and the results are consistent with the previous versions. Efforts have also been put into developing scripts to aid in the process of automating certain sections of the V&V work. As some of the V&V efforts use Environmental Systems Research Institute’s (ESRI) tools upon which the START framework is built, the START data were compared against outputs from tools like Quantum Geographic Information System (QGIS) for buffer zone populations and route lengths to ensure independence of the V&V process. Good agreement was observed between the START results and the independent V&V studies with the majority of the differences falling between 1% and 5% for populations within the buffer zone and route distance. This presentation describes the development and design of the START tool, V&V methods employed for various metrics of interest and their respective results, and future plans.

START, transportation, GIS, V&V↗

Alternative Analysis and Prioritization of Department of Energy “TBD” Materials with No Identified Disposition Pathway

The Department of Energy (DOE) complex manages a significant inventory of excess nuclear materials for which disposition pathways have not been identified, commonly referred to as "To Be Determined" (TBD) items. The Disposition Pathways Program, initiated in FY2018, provides a standardized framework for identifying viable disposition pathways for these materials. In 2023, the program undertook a comprehensive review and systematic analysis of the remaining TBD material groups, updating the assessment from the 2020 TBD Study using the 2022 fiscal year-end Nuclear Material Inventory Assessment (NMIA) as the primary data source. This effort aimed to utilize quantitative analysis to down-select from a wide range of potential disposition options and prioritize the remaining pathways to facilitate informed, risk-based decision-making for future programmatic funding and execution. This paper details the alternative analysis methodology used for screening and prioritization, highlighting the key criteria, ranking process, and resultant recommendations. The study successfully narrowed fifty-two potential disposition options down to nineteen, providing a focused path forward for addressing a longstanding challenge within the DOE complex.

Ramsey, Catherine [Savannah River National Laborat↗