Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERMANENT MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Plasma studies on electron cyclotron resonance light ion source at CEA/Saclay

By the 90s, the CEA has undertaken to develop the production of intense light ion beams from unconfined ECR plasma. Today, three sources for IPHI, SPIRAL2, and IFMIF projects (respectively, 100 mA of H{sup +}, 8 mA of D{sup +}, and 140 mA of D{sup +}) are installed at CEA/Saclay. In order to improve performances and decrease dimensions of these sources, it is necessary to better understand the mechanisms involved in the production and extraction of particles. As a consequence, theoretical and experimental studies are being carried out. We present a theoretical study based on SOLMAXP, a home-made particle-in-cell code. The aim is to investigate the possibility of reducing the plasma chamber size without loss of beam characteristics. This code has been validated by beam intensity measurements on a permanent magnet based source, producing a proton beam of 30 mA at 40 kV on the test bench BETSI. In order to reduce experimentally the dimensions of plasma chamber, a new source, named ALISES with variable plasma chamber volume, is under assembly.

43 PARTICLE ACCELERATORS↗

Recycler Chromaticities and End Shims for NOvA at Fermilab

In era of NOvA operation, it is planned to slip-stack six on six Booster proton batches in the Recycler ring for a total intensity of 5 x 10{sup 13} protons/cycle. During the slip-stacking, the chromaticities are required to be jumped from (-2,-2) to (-20,-20). However, with the existing 2 families of powered sextupoles in the lattice, the chromaticities can only be adjusted to (-12,-12) from (-2,-2). On the other hand, the presently designed Recycler lattice for Nova replaces the 30 straight section with 8 'D-D half FODO cells'. With the limit of the feasible quad strength, 3 quads in a half-cell were used to obtain the working point under, and the maximum beta-functions in this section cannot be less than 80 m. In this paper, we re-designed the end shims of the permanent magnets in the ring lattice with appropriate quadrupole and sextupole components to meet both chromaticity and tune requirements. We are able to use 2 quads in a half cell in RR30 straight section within feasible quad strength. The maximum beta-functions are also lowered to around 55 m. The dynamic aperture tracking has been done using MAD to simulate the scenario of beam injection into the Recycler ring for Nova.

43 PARTICLE ACCELERATORS↗

Liquid metal alloy ion source based metal ion injection into a room-temperature electron beam ion source

We have carried out a series of measurements demonstrating the feasibility of using the Dresden electron beam ion source (EBIS)-A, a table-top sized, permanent magnet technology based electron beam ion source, as a charge breeder. Low charged gold ions from an AuGe liquid metal alloy ion source were injected into the EBIS and re-extracted as highly charged ions, thereby producing charge states as high as Au{sup 60+}. The setup, the charge breeding technique, breeding efficiencies as well as acceptance and emittance studies are presented.

43 PARTICLE ACCELERATORS↗

Development of a compact filament-discharge multi-cusp H{sup -} ion source

A 14 MeV medical cyclotron with the external ion source has been designed and is being constructed at China Institute of Atomic Energy. The H{sup -} ion will be accelerated by this machine and the proton beam will be extracted by carbon strippers in dual opposite direction. The compact multi-cusp H{sup -} ion source has been developed for the cyclotron. The 79.5 mm long ion source is 48 mm in diameter, which is consisting of a special shape filament, ten columns of permanent magnets providing a multi-cusp field, and a three-electrode extraction system. So far, the 3 mA/25 keV H{sup -} beam with an emittance of 0.3 {pi} mm mrad has been obtained from the ion source. The paper gives the design details and the beam test results. Further experimental study is under way and an extracted beam of 5 mA is expected.

43 PARTICLE ACCELERATORS↗

Broadband electromagnetic power harvester from vibrations via frequency conversion by impact oscillations

In this paper, we propose an electromagnetic power harvester that uses a transformative multi-impact approach to achieve a wide bandwidth response from low frequency vibration sources through frequency-up conversion. The device consists of a pick-up coil, fixed at the free edge of a cantilever beam with high resonant frequency, and two cantilever beams with low excitation frequencies, each with an impact mass attached at its free edge. One of the two cantilevers is designed to resonate at 25 Hz, while the other resonates at 50 Hz within the range of ambient vibration frequency. When the device is subjected to a low frequency vibration, the two low-frequency cantilevers responded by vibrating at low frequencies, and thus their thick metallic masses made impacts with the high resonance frequency cantilever repeatedly at two locations. This has caused it along with the pick-up coil to oscillate, relative to the permanent magnet, with decaying amplitude at its resonance frequency, and results in a wide bandwidth response from 10 to 63 Hz at 2 g. A wide bandwidth response between 10–51 Hz and 10–58 Hz at acceleration values of 0.5 g and 2 g, respectively, were achieved by adjusting the impact cantilever frequencies closer to each other (25 Hz and 45 Hz). A maximum output power of 85 μW was achieved at 5 g at 30 Hz across a load resistor, 2.68 Ω.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A comparison of efficiency-aware model-predictive control approaches for wave energy devices

In this study, we compare four different formulations of model predictive control that attempt to maximise electrical power generated by a wave energy converter (WEC). Control laws include (1) pure maximisation of mechanical power, (2) maximisation of mechanical power with a control penalty factor, (3) maximisation of electrical power using power conversion efficiency, and (4) maximisation of electrical power using the full electro-mechanical model of a system. For this study, a wave-to-wire model is developed for a floating spherical buoy connected to a permanent magnet synchronous generator. The performance of the controllers, including the mechanical and electrical power outputs, is compared in irregular wave conditions for the unconstrained and force-constrained scenarios. The results demonstrate that the controller designed to maximise mechanical power is not suitable for practical applications and may lead to negative electrical power output due to the non-ideal power take-off efficiency. Moreover, the replacement of the power take-off dynamics by the efficiency coefficient does not guarantee the maximum electrical power production.

16 TIDAL AND WAVE POWER↗

Advanced Lightweight HiE PMDD Generator for WTGs

Preliminary designs of advanced lightweight permanent magnet direct drive generators for offshore and “tall wind” onshore applications utilizing funding from DOE/EERE/WETO were developed by WEG, RTX, NREL and supporting partners. This work significantly reduces tower head mass, increases efficiency, reduces the rare earth content of the generator, and leads to additional turbine system benefits that improve competitiveness, such as the use of taller towers onshore and less expensive foundations (“hull”) for floating offshore. The end result is an approximately 10% reduction of LCOE in both cases, which could significantly improve competitiveness and support the EERE/DOE goal of promoting US manufacturing.

17 WIND ENERGY↗

Fractional order PID controller for improvement of PMSM speed control in aerospace applications

Because of the benefits reduced size, cost and maintenance, noise, CO2 emissions and increased control flexibility and precision, to meet these expectations, electrical equipment increasingly utilize in modern aircraft systems and aerospace industry rather than conventional mechanic, hydraulic, and pneumatic power systems. Electric motor drives are capable of converting electrical power to drive actuators, pumps, compressors, and other subsystems at variable speeds. In the past decades, permanent magnet synchronous motor (PMSM) and brushless dc (BLDC) motor were investigated for aerospace applications such as aircraft actuators. In this paper, the fractional-order PID controller is used in the design of speed loop of PMSM speed control system. Having more parameters for tuning fractional order PID controller lead to good performance ratio to integer order. This good performance is shown by comparison fractional order PID controller with the conventional PI and tuned PID controller by Genetic algorithm in MATLAB soft wear.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Power efficiency improvements with the radio frequency H{sup −} ion source

CW 13.56 MHz radio frequency-driven H{sup −} ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H{sup −} beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation of the main plasma from the plasma electrode. While the original system provided better control over the e{sup −}/H{sup −} ratio, the new configuration has led to a higher production efficiency of 1 mA H{sup −} at 1.75 kW RF power. The latest results and upgrade plans are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a flexible optical fiber based high resolution integrated PET/MRI system

Purpose: The simultaneous measurement of PET and magnetic resonance imaging (MRI) is an emerging field for molecular imaging research. Although optical fiber based PET/MRI systems have advantages on less interference between PET and MRI, there is a drawback in reducing the scintillation light due to the fiber. To reduce the problem, the authors newly developed flexible optical fiber bundle based block detectors and employed them for a high resolution integrated PET/MRI system. Methods: The flexible optical fiber bundle used 0.5 mm diameter, 80 cm long double clad fibers which have dual 12 mm Multiplication-Sign 24 mm rectangular inputs and a single 24 mm Multiplication-Sign 24 mm rectangular output. In the input surface, LGSO scintillators of 0.025 mol.% (decay time: {approx}31 ns: 0.9 mm Multiplication-Sign 1.3 mm Multiplication-Sign 5 mm) and 0.75 mol.% (decay time: {approx}46 ns: 0.9 mm Multiplication-Sign 1.3 mm Multiplication-Sign 6 mm) were optically coupled in depth direction to form depth-of-interaction detector, arranged in 11 Multiplication-Sign 13 matrix and optically coupled to the fiber bundle. The two inputs of the bundle are bent for 90 Degree-Sign , bound to one, and are optically coupled to a Hamamatsu 1-in. square position sensitive photomultiplier tube. Results: Light loss due to the fiber bundle could be reduced and the performance of the block detectors was improved. Eight optical fiber based block detectors (16 LGSO blocks) were arranged in a 56 mm diameter ring to form a PET system. Spatial resolution and sensitivity were 1.2 mm full-width at half-maximum and 1.2% at the central field-of-view, respectively. Sensitivity change was less than 1% for 2 Degree-Sign C temperature changes. This PET system was integrated with a 0.3 T permanent magnet MRI system which has 17 cm diameter hole at the yoke area for insertion of the PET detector ring. There was no observable interference between PET and MRI. Simultaneous imaging of PET and MRI was successfully performed for small animal studies. Conclusions: The authors confirmed that the developed high resolution PET/MRI system is promising for molecular imaging research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact microwave ion source for industrial applications

A 2.45 GHz microwave ion source for ion implanters has many good properties for industrial application, such as easy maintenance and long lifetime, and it should be compact for budget and space. But, it has a dc current supply for the solenoid and a rf generator for plasma generation. Usually, they are located on high voltage platform because they are electrically connected with beam extraction power supply. Using permanent magnet solenoid and multi-layer dc break, high voltage deck and high voltage isolation transformer can be eliminated, and the dose rate on targets can be controlled by pulse duty control with semiconductor high voltage switch. Because the beam optics does not change, beam transfer components, such as focusing elements and beam shutter, can be eliminated. It has shown the good performances in budget and space for industrial applications of ion beams.

43 PARTICLE ACCELERATORS↗

A framework for evaluating the accessibility of raw materials from end-of-life products and the Earth’s crust

Highlights: • Defined and conceptualised raw material accessibility. • Applied concept extraction in raw material management. • Developed a framework for evaluating raw material accessibility. •Carried out an evaluation with End-of-Life products and natural deposits. • Developed an early project stage evaluation for accessing raw materials. - Abstract: An increasing number of geochemically scarce metallic raw materials are entering into our lives via new technologies. A reversal of this trend is not foreseeable, leading to concerns regarding the security of their supply. However, the evaluation of raw material supply is currently hampered by inconsistent use of fundamental terminologies and incomplete assessment criteria. In this paper, we aim to establish a consistent framework for evaluating raw material supply from both anthropogenic and geological sources. A method for concept extraction was applied to evaluate systematically the use of fundamental terms in the evaluation of raw material supply. The results have shown that ‘availability’ is commonly used in raw material supply evaluations, whilst other researchers suggest that raw material supply should be evaluated based on ‘accessibility’. It was revealed that ‘accessibility’ actually comprises two aspects: ‘availability’ and ‘approachability’. Raw material ‘approachability’ has not previously been explicitly addressed at a system level. A novel, consistent framework for evaluating raw material supply was therefore developed. To demonstrate the application of the established framework, we evaluated the raw material supply of four rare earth element case studies. Three case studies are End-of-Life products (the anthroposphere) from Switzerland: (i) phosphors in fluorescent lamps, (i) permanent magnets in the drive motors of electric cars and (iii) fibre optic cable. The fourth case study source is the Earth’s crust (the geosphere): Mount Weld deposit in Australia. The framework comprises a comprehensive evaluation of six components relating to raw material mining and processing: their geological knowledge, eligibility, technology, economic, societal and environmental impacts. Our results show that metals are not considered to be fully accessible in any of the case studies due to a lack of necessary technologies and potential societal and environmental impacts. The framework presented here can serve as a starting point for the development of an evaluation framework for raw material accessibility at an early project development stage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Ce-Fe-Ti System: Phase Equilibria in the Fe-rich Corner at 1000 °C

The rare earth–iron–transition metal systems are of increasing interest in the search for novel permanent magnet phases. This work reports on the solidification behavior, phase equilibria and stability range of solid phases in the ternary Ce-Fe-Ti system, focusing on the iron-rich region (> 65 at.% Fe) of the isothermal section at 1000 °C. Further, two ternary phases Ce 1.03 Fe 12-x Ti x (x = 0.87–1.02) with ThMn 12 structure type and Ce 3.06 Fe 27.6 Ti 1.4 with Nd 3 Fe 29 structure type were observed. Magnetic measurements of Ce 1.03 Fe 12-x Ti x and Ce 3.06 Fe 27.6 Ti 1.4 revealed ferromagnetic ordering with Curie temperatures of 550 K and 327 K, respectively.

36 MATERIALS SCIENCE↗

A compact E × B filter: A multi-collector cycloidal focusing mass spectrometer

A compact E × B mass spectrometer is presented. The mass spectrometer presented is termed a “perfect focus” mass spectrometer as the resolution of the device is independent of both the initial direction and energy of the ions (spatial and energy independent). The mass spectrometer is small in size (∼10.7 in.{sup 3}) and weight (∼2 kg), making it an attractive candidate for portability when using small, permanent magnets. A multi-collector Faraday cup design allows for the detection of multiple ion beams in discrete collectors simultaneously; providing the opportunity for isotope ratio monitoring. The mass resolution of the device is around 400 through narrow collector slits and the sensitivity of the device follows expected theoretical calculations of the ion current produced in the electron impact ion source. Example mass spectra obtained from the cycloidal focusing mass spectrometer are presented as well as information on mass discrimination based on instrumental parameters and isotope ratio monitoring of certain ion signals in separate Faraday cups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructure Alignment Effects from Engineered Cooling during Additive Manufacturing of Alnico Magnets from Prealloyed Powder

Alnico is a rare-earth free; permanent magnet (PM) which maintains its saturation magnetization while at temperatures up to 550°C but lacks the coercivity and energy product needed for a wide range of demanding applications. With an optimal set of processing and manufacturing techniques, Alnico could replace Dy-free Nd-Fe-B magnets in certain applications if the microstructure is textured in a $\langle$001$\rangle$ direction. Additive manufacturing (AM) of near-net-shape magnets may provide such texture. To investigate the possibility, directed-energy deposition (DED) in conjunction with an actively cooled substrate was used to build samples with a compositionally modified, gas-atomized, Alnico 8 alloy. The resulting samples were solutionized and quenched, followed by magnetic annealing and a heat treatment. Magnetic properties and microstructures are compared to previous work.

36 MATERIALS SCIENCE↗

Recovering heavy rare earth metals from magnet scrap

A method of treating rare earth metal-bearing permanent magnet scrap, waste or other material in a manner to recover the heavy rare earth metal content separately from the light rare earth metal content. The heavy rare earth metal content can be recovered either as a heavy rare earth metal-enriched iron based alloy or as a heavy rare earth metal based alloy.

36 MATERIALS SCIENCE↗

Commissioning of helium injector for coupled radio frequency quadrupole and separated function radio frequency quadrupole accelerator

A project to study a new type of acceleration structure has been launched at Peking University, in which a traditional radio frequency quadrupole (RFQ) and a separated function radio frequency quadrupole are coupled in one cavity to accelerate the He+ beam. A helium injector for this project is developed. The injector consists of a 2.45 GHz permanent magnet electron cyclotron resonance ion source and a 1.16 m long low energy beam transport (LEBT). The commissioning of this injector was carried out and an onsite test was held in June 2013. A 14 mA He+ beam with the energy of 30 keV has been delivered to the end of the LEBT, where a diaphragm with the diameter of 7 mm is located. The position of the diaphragm corresponds to the entrance of the RFQ electrodes. The beam emittance and fraction were measured after the 7 mm diaphragm. Its rms emittance is about 0.14 π mm mrad and the fraction of He+ is about 99%.

43 PARTICLE ACCELERATORS↗