Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE CHANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Non-resonant electromechanical energy harvesting using inter-ferroelectric phase transitions

Non-resonant electromechanical energy harvesting is demonstrated under low frequency excitation (<50 Hz) using [110]{sub C}-poled lead indium niobate-lead magnesium niobate-lead titanate relaxor ferroelectric single crystals with compositions near the morphotropic phase boundary. The efficiency of power generation at the stress-induced phase transition between domain-engineered rhombohedral and orthorhombic ferroelectric states is as much as four times greater than is obtained in the linear piezoelectric regime under identical measurement conditions but during loading below the coercive stress of the phase change. The phase transition mode of electromechanical transduction holds potential for non-resonant energy harvesting from low-frequency vibrations and does not require mechanical frequency up-conversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural phase transitions in EuFe[subscript 2]As[subscript 2] superconductor at low temperatures and high pressures

The crystal structure of EuFe{sub 2}As{sub 2} has been studied up to a pressure of 35 GPa and down to a temperature of 8 K using temperature dependent x-ray diffraction in a diamond anvil cell at a synchrotron source. At 4.3 GPa, we have detected a structural phase transition from a high temperature tetragonal phase with I4/mmm space group to a low temperature orthorhombic phase with Fmmm space group around 120 K. With the application of pressure at a low temperature of 10 K, the orthorhombic phase is suppressed and a phase change to a collapsed tetragonal phase with I4/mmm space group is observed at 11 GPa. This collapsed tetragonal phase is similar to the one observed at ambient temperature and pressure above 8.5 GPa. We have shown that the collapsed tetragonal phase of EuFe{sub 2}As{sub 2} has the same pressure-volume (P-V) equation of state at ambient temperature and at 10 K, implying that the high pressure phase of EuFe{sub 2}As{sub 2} has a negligible thermal expansion coefficient.

36 MATERIALS SCIENCE↗

Combinatorial appraisal of transition states for in situ pair distribution function analysis

In situ total scattering measurements are increasingly utilized to follow atomic and nanoscale structural details of phase transitions and other transient processes in materials. This contribution presents an automated method and associated tool set to analyze series of diffraction and pair distribution function data with a linear combination of end-member states. It is demonstrated that the combinatorial appraisal of transition states (CATS) software tracks phase changes, relative phase fractions and length scales of interest in experimental data series. Here it is further demonstrated, using a series of local structure data simulations, that the misfit of such a model can reveal details of phase aggregation and growth related to the pair distribution function's sensitivity to interphase correlations. CATS may be applied to quantitative evaluation of many transient processes, including amorphous-to-crystalline phase transitions, the evolution of solid-solution behaviors, the precipitation and growth of aggregates, and other atomic to nanoscale details of crystallization and phase transformation phenomena.

36 MATERIALS SCIENCE↗

Fluoropolymer Aging Assessments

Fluoropolymer (FP) binders are commonly only a few percent of polymer bonded explosive compositions but they are essential for the mechanical integrity of the part. Because we are using newly manufactured binders, we need to understand how lot variations might affect processing, aging, and mechanical properties. Time, temperature and radiation induce phase changes in fluoropolymers. These phase changes can rearrange the polymer causing crystalline domains to nucleate and grow that can alter mechanical properties. These studies quantify the aging process so that it may be cross correlated with changes in the adhesion, strength, and other properties important for performance.

36 MATERIALS SCIENCE↗

The interaction of interstellar gas with stellar density wave packets

We have numerically studied the interaction between interstellar gas and a gravitational perturbation produced by a fluctuation in the stellar mass distribution. For a simple equation of state, shock waves develop even if the gravitational perturbation is aperiodic and transient. In a medium which can change thermal phase, shocks do not form and the gas makes a transition directly to the cold, dense phase. The cold material has an anomalous velocity imparted to it by the gravitational perturbation and it becomes an accretion front moving through the hot gas and capturing it. The accretion fronts trigger thermal phase change on a large scale and can reproduce the extent of observed cold clouds. Furthermore their high mass is favorable to gravitational instability and subsequent star formation.

Baker, P. L.↗

Advanced solar receiver conceptual design study

High temperature solar dynamic Brayton and Stirling receivers are investigated as candidate electrical power generating systems for future LEO missions. These receivers are smaller and more efficient than conventional receivers, and they offer less structural complexity and fewer thermal stress problems. Use of the advanced Direct Absorption Storage Receiver allows many of the problems associated with working with high-volumetric-change phase-change materials to be avoided. A specific mass reduction of about 1/3 with respect to the baseline receiver has been realized.

Kesseli, J. B.↗

Performance characteristics of a thermal energy storage module - A transient PCM/forced convection conjugate analysis

The performance of a thermal energy storage module is simulated numerically. The change of phase of the phase-change material (PCM) and the transient forced convective heat transfer for the transfer fluid with low Prandtl numbers are solved simultaneously as a conjugate problem. A parametric study and a system optimization are conducted. The numerical results show that module geometry is crucial to the design of a space-based thermal energy storage system.

Cao, Y.↗

A PCM/forced convection conjugate transient analysis of energy storage systems with annular and countercurrent flows

Latent heat energy storage systems with both annular and countercurrent flows are modeled numerically. The change of phase of the phase-change material (PCM) and the transient forced convective heat transfer for the transfer fluid are solved simultaneously as a conjugate problem. A parametric study and a system optimization are conducted. It is found that the energy storage system with the countercurrent flow is an efficient way to absorb heat energy in a short period for pulsed power load space applications.

Cao, Y.↗

Measurement of Attachment-Line Location in a Wind-Tunnel and in Supersonic Flight

As a part of the supersonic laminar flow control research program, experiments are being conducted to measure the attachment-line flow characteristics and its location on a highly swept aircraft wing. Initially, subsonic wind tunnel tests were performed on two-dimensional models to develop sensors and techniques for the flight application. The wind tunnel test results suggest that, under certain conditions at the leading edge there are low frequency streamwise velocity fluctuations present in the laminar boundary layer which undergo a phase change at the stagnation point Therefore, if present in flight, this distinct change in phase, i.e., time shift of signals from either side of the stagnation point, can be used to determine the stagnation-line or attachment-line location. The phase-reversal phenomenon was examined to determine the attachment-line location on a highly swept wing. Test results indicate that the phase-reversal phenomenon may not be applicable in flight. Additional data analyses is continuing to account for phase differences introduced by the recording system. A final determination on the existence of phase-reversal in flight will require the results of further analysis and possibly additional flight testing. Some representative attachment-line data are presented and discussed as well as the results from the wind tunnel investigation.

Flight Testing↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Design Considerations for Fusible Heat Sink

Traditionally radiator designs are based off a passive or flow through design depending on vehicle requirements. For cyclical heat loads, a novel idea of combining a full flow through radiator to a phase change material is currently being investigated. The flow through radiator can be designed for an average heat load while the phase change material can be used as a source of supplemental heat rejections when vehicle heat loads go above the average load. Furthermore, by using water as the phase change material, harmful radiation protection can be provided to the crew. This paper discusses numerous trades conducted to understand the most optimal fusible heat sink design for a particular heat load. Trades include configuration concepts, amount of phase change needed for supplemental heat rejection, and the form of interstitial material needed for optimal performance. These trades were used to culminate to a fusible heat sink design. The paper will discuss design parameters taken into account to develop an engineering development unit.

Cognata, Thomas J.↗

Enhancing the thermosiphon-driven discharge of a latent heat thermal storage system used in a personal cooling device

Personal cooling devices reduce energy loads by allowing buildings to operate with elevated setpoint temperatures, without compromising on the occupant comfort. One such novel technology called the Roving Comforter (RoCo) uses a compact R134a based vapor compression system for cooling. Following its cooling operation, during which waste heat from the condensing refrigerant is stored in a phase change material (PCM), a two-phase loop thermosiphon is used to discharge (solidify) the PCM to enable its next operation. The transient operation of this thermosiphon is the focus of the present paper. Use of a PCM as the storage medium provides high energy density due to the ability to store thermal energy as latent heat during the phase transition; however, the discharge rate is limited by the low thermal conductivity of the PCM. Insertion of a graphite foam within the PCM can increase the rate of discharge and decrease the downtime of the cooling device. Since graphite enhancement involves a tradeoff between improving the discharge time at the expense of PCM volumetric latent heat, the impact of graphite foam density on the PCM discharge rate is investigated by using a Modelica-based transient model of the thermosiphon. The semi-empirical model, which uses relevant heat transfer coefficient and pressure drop correlations for both refrigerant and airside heat transfer, captures the complex phenomena involving simultaneous phase change of the refrigerant and the PCM. Finally, the graphite enhanced PCM selected from this analysis results in a 51% reduction in the discharge time with addition of only 5% to the thermal storage weight, without compromising the required cooling time.

42 ENGINEERING↗

Chemistry and Reactivity of Oxide Films on Aluminum Clad Test Reactor Fuels

This paper describes recent work performed to assess the degradation of aluminum spent nuclear fuel (ASNF) as part of an ongoing Department of Energy project. As part of a multi-task effort, this paper specifically describes efforts initiated in 2018 to better understand chemical phenomena and degradation in ASNF). In this paper experimental and modeling activities are described. The modeling effort presents initial results in two areas potentially influencing stability. Using an established electrolyte model based on experimental data, the solubility of aluminum as a function of temperature and pH was examined. This work describes interesting results for the minimum pH providing relevant data that was not available from the literature. It was found that solubility increases with temperature and that the minimum pH shifts to low pH with increase in temperature. The second area involves understanding the metallurgy of aluminum alloys during fuel drying. In this study, the temperature range from 100°C to 300°C was analyzed. Thermodynamic models predict that AA1100 will not experience significant phase changes while the more highly alloyed AA6061 and AA5052 may experience significant phase changes. These thermodynamic measurements establish a potential for phase changes during drying, however they do not predict the kinetics for such processes. Phase 1 of the experimental program has initiated and results are forthcoming. The test program will examine aluminum oxidation under anticipated dry storage conditions (temperature and humidity). Examination of localized corrosion due to tight crevices and galvanic contact (with stainless steel) will be included. Finally, water deliquescence will be assessed using thermogravimetric analysis with dynamic humidity profiles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemistry and Reactivity of Oxide Films on Aluminum Clad Test Reactor Fuels - 19294

This paper describes recent work performed to assess the degradation of aluminum spent nuclear fuel (ASNF) as part of an ongoing Department of Energy project. As part of a multi-task effort, this paper specifically describes efforts initiated in 2018 to better understand chemical phenomena and degradation in ASNF). In this paper experimental and modeling activities are described. The modeling effort presents initial results in two areas potentially influencing stability. Using an established electrolyte model based on experimental data, the solubility of aluminum as a function of temperature and pH was examined. This work describes interesting results for the minimum pH providing relevant data that was not available from the literature. It was found that solubility increases with temperature and that the minimum pH shifts to low pH with increase in temperature. The second area involves understanding the metallurgy of aluminum alloys during fuel drying. In this study, the temperature range from 100 deg. C to 300 deg. C was analyzed. Thermodynamic models predict that AA1100 will not experience significant phase changes while the more highly alloyed AA6061 and AA5052 may experience significant phase changes. These thermodynamic measurements establish a potential for phase changes during drying, however they do not predict the kinetics for such processes. Phase 1 of the experimental program has initiated and results are forthcoming. The test program will examine aluminum oxidation under anticipated dry storage conditions (temperature and humidity). Examination of localized corrosion due to tight crevices and galvanic contact (with stainless steel) will be included. Finally, water deliquescence will be assessed using thermogravimetric analysis with dynamic humidity profiles. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decomposing Cloud Radiative Feedbacks by Cloud-Top Phase

Changes in cloud scattering properties and emissivity that arise from atmospheric warming cause substantial radiative feedbacks in model projections of anthropogenic climate change, and the relative importance of the underlying mechanisms is poorly understood. One leading hypothesis is that ice-to-liquid conversions cause clouds to optically thicken, producing a major negative feedback. We test this hypothesis by developing a method to decompose cloud radiative feedbacks by cloud-top phase. The method is applied to an ensemble of six state-of-the-art global climate models run with prescribed sea surface temperature. In these simulations, the global mean of the net cloud scattering and emissivity feedback from cloud-phase conversions ranges from −0.17 to −0.01 W m −2 K −1 , while the overall net cloud feedback ranges from 0.02 to 0.91 W m −2 K −1 . The multimodel mean of the cloud scattering and emissivity feedback from cloud-phase conversions is approximately 19% of the magnitude of the multimodel mean of the overall cloud feedback (−0.10 vs 0.52 W m −2 K −1 ). These results indicate that cloud-phase conversions cause a robust negative feedback by changing cloud scattering and emissivity, but this mechanism makes a modest contribution to the overall cloud feedback at the global scale.

Climate change↗

Novel Infiltration Diagnostics based on Laser-line Scanning and Infrared Temperature Field Imaging

This project targets the building energy efficiency problems induced by building infiltration/leaks. The current infiltration inspection techniques often require extensive visual inspection and/or whole building pressure test. These current techniques cannot meet more than three of the below five criteria of ideal infiltration diagnostics: 1. location and extent diagnostics, 2. building-level application, 3. least surface preparation, 4. weather-proof, and 5. non-disruption to building occupants. These techniques are either too expensive or time consuming, and often lack accuracy and repeatability. They are hardly applicable to facades/facades section. The goal of the project was to develop a novel infiltration diagnostics technology based on laser line-scanning and simultaneous infrared temperature imaging. A laboratory scale experimental setup was designed to mimic a model house of well-defined pressure difference below or above the outside pressure. Algorithms and Matlab-based programs had been developed for recognition of the hole location in infrared images. Our experiment based on laser wavelengths of 450 and 1550 nm and laser beam diameters of 4-25 mm showed that the location of the holes could be identified using laser heating; the diagnostic approach however could not readily distinguish between infiltration and non-infiltration points. To significantly improve the scanning throughput and recognition accuracy, a second approach was explored, developed, and extensively tested. It incorporates a liquid spray on the surface to induce extra phase change cooling effect. In this spray method, we termed it as PECIT (Phase-change Enhanced Cooling Infrared Thermography), phase-change enhanced cooling was used, which significantly amplifies the effect of air flow (infiltration and exfiltration). This heat transfer method worked extremely well to identify infiltration and exfiltration locations with high accuracy and increased throughput. The PECIT technique was systematically developed and tested for through holes with diameters 1 mm to 2 mm, and diagonal lines of 0.5 mm width at different camera-wall distances of 46 cm to 200 cm, under different pressure differences from 5 Pa to 20 Pa, and under different wind conditions. The PECIT technique had either met or exceeded the goals proposed in the project. For exfiltration, we achieved 100% accuracy under a much lower pressure difference of 10 Pa (proposed one: 50 Pa with stretch goal of 15 Pa). For infiltration, we achieved >90% accuracy under a much lower pressure difference of 10 Pa (proposed one: 50 Pa with stretch goal of 15Pa). For exfiltration, we achieved 100% accuracy under a much lower pressure difference of 10 Pa. For infiltration, we achieved 100% accuracy under a much lower pressure difference of 10 Pa. The PECIT technique can reach a throughput of 120 m2/h, which is 4 times the proposed goal for the laser line-scanning and simultaneous infrared temperature imaging approach. For commercialization and market penetration, we had meetings with two companies for feedback collection and further improvement for practical use. Also, we have interacted with Office of Intellectual Property and Technology Transfer of Iowa State University for idea disclosure and patent application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Formulation for the Prediction of Solid/Liquid Change of a Binary Alloy

A computational model is presented for the prediction of solid/liquid phase change energy transport including the influence of free convection fluid flow in the liquid phase region. The computational model considers the velocity components of all non-liquid phase change material control volumes to be zero but fully solves the coupled mass-momentum problem within the liquid region. The thermal energy model includes the entire domain and uses an enthalpy like model and a recently developed method for handling the phase change interface nonlinearity. Convergence studies are performed and comparisons made with experimental data for two different problem specifications. The convergence studies indicate that grid independence was achieved and the comparison with experimental data indicates excellent quantitative prediction of the melt fraction evolution. Qualitative data is also provided in the form of velocity vector diagrams and isotherm plots for selected times in the evolution of both problems. The computational costs incurred are quite low by comparison with previous efforts on solving these problems.

Schneider, G. E.↗

Design Principles to Govern Electrode Fabrication for the Lithium Trivanadate Cathode

A full depth of discharge mathematical model for the lithium trivanadate cathode, considering lithiation of the layered α-phase, phase change, and lithiation of the rock-salt like β-phase at lower potentials, is developed. The coupled electrode-scale and crystal-scale model is fit to electrochemical data, and additionally validated with operando EDXRD. There is good agreement between the simulated and measured spatial variation of the volume fraction of the β-phase. This mathematical model is used to guide electrode fabrication, accounting for both ionic and electronic transport effects. Values of three design parameters—electrode thickness, porosity, and volume fraction of conductor—are identified, and the sensitivity of the energy density to these design parameters is quantified. The model is also used to investigate electrode design to create electrodes that deliver the maximum achievable energy density under the constraint that the α to β-phase transition is avoided, since phase change has been demonstrated to reduce cycle life. The energy density sacrificed to avoid phase change decreases at higher discharge rates, but the target values for electrode fabrication remain the same as those when optimizing the electrode for the full depth of discharge.

25 ENERGY STORAGE↗