Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Postoperative Prostate-Specific Antigen Velocity Independently Predicts for Failure of Salvage Radiotherapy After Prostatectomy

Purpose: Identification of patients most likely to benefit from salvage radiotherapy (RT) using postoperative (postop) prostate-specific antigen (PSA) kinetics. Methods and Materials: From 1984 to 2004, 81 patients who fit the following criteria formed the study population: undetectable PSA after radical prostatectomy (RP); pathologically negative nodes; biochemical relapse defined as a persistently detectable PSA; salvage RT; and two or more postop PSAs available before salvage RT. Salvage RT included the whole pelvic nodes in 55 patients and 4 months of total androgen suppression in 56 patients. The median follow-up was >5 years. All relapses were defined as a persistently detectable PSA. Kaplan-Meier and Cox proportional hazards multivariable analysis were performed for all clinical, pathological, and treatment factors predicting for biochemical relapse-free survival (bRFS). Results: There were 37 biochemical relapses observed after salvage RT. The 5-year bRFS after salvage RT for patients with postop prostate-specific antigen velocity {<=}1 vs. >1 ng/ml/yr was 59% vs. 29%, p = 0.002. In multivariate analysis, only postop PSAV (p = 0.0036), pre-RT PSA level {<=}1 (p = 0.037) and interval-to-relapse >10 months (p = 0.012) remained significant, whereas pelvic RT, hormone therapy, and RT dose showed a trend (p = {approx}0.06). PSAV, but not prostate-specific antigen doubling time, predicted successful salvage RT, suggesting an association of zero-order kinetics with locally recurrent disease. Conclusions: Postoperative PSA velocity independently predicts for the failure of salvage RT and can be considered in addition to high-risk features when selecting patients in need of systemic therapy following biochemical failure after RP. For well-selected patients, salvage RT can achieve high cure rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percentage of Biopsy Cores Positive for Malignancy and Biochemical Failure Following Prostate Cancer Radiotherapy in 3,264 Men: Statistical Significance Without Predictive Performance

Purpose: To define and incorporate the impact of the percentage of positive biopsy cores (PPC) into a predictive model of prostate cancer radiotherapy biochemical outcome. Methods and Materials: The data of 3264 men with clinically localized prostate cancer treated with external beam radiotherapy at four institutions were retrospectively analyzed. Standard prognostic and treatment factors plus the number of biopsy cores collected and the number positive for malignancy by transrectal ultrasound-guided biopsy were available. The primary endpoint was biochemical failure (bF, Phoenix definition). Multivariate proportional hazards analyses were performed and expressed as a nomogram and the model's predictive ability assessed using the concordance index (c-index). Results: The cohort consisted of 21% low-, 51% intermediate-, and 28% high-risk cancer patients, and 30% had androgen deprivation with radiotherapy. The median PPC was 50% (interquartile range [IQR] 29-67%), and median follow-up was 51 months (IQR 29-71 months). Percentage of positive biopsy cores displayed an independent association with the risk of bF (p = 0.01), as did age, prostate-specific antigen value, Gleason score, clinical stage, androgen deprivation duration, and radiotherapy dose (p < 0.001 for all). Including PPC increased the c-index from 0.72 to 0.73 in the overall model. The influence of PPC varied significantly with radiotherapy dose and clinical stage (p = 0.02 for both interactions), with doses <66 Gy and palpable tumors showing the strongest relationship between PPC and bF. Intermediate-risk patients were poorly discriminated regardless of PPC inclusion (c-index 0.65 for both models). Conclusions: Outcome models incorporating PPC show only minor additional ability to predict biochemical failure beyond those containing standard prognostic factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Volume Changes on 1.5 Tesla Endorectal MRI During Neoadjuvant Androgen Suppression Therapy for Higher-Risk Prostate Cancer and Recurrence in Men Treated Using Radiation Therapy Results of the Phase II CALGB 9682 Study

Purpose: We prospectively determined whether the change in tumor volume (TV) during 2 months of neoadjuvant androgen suppression therapy (nAST) measured using conventional 1.5 Tesla endorectal magnetic resonance imaging (eMRI) was associated with the risk of recurrence after radiation (RT) and 6 months of AST. Patients and Methods: Between 1997 and 2001, 180 men with clinical stage T1c-T3cN0M0 adenocarcinoma of the prostate were registered. Fifteen were found to be ineligible and the institutional MR radiologist could not assess the TV in 32, leaving 133 for analysis. Multivariable Cox regression analysis was used to assess whether a significant association existed between eMRI-defined TV progression during nAST and time to recurrence adjusting for prostate-specific antigen (PSA) level, Gleason score (8 to 10 or 7 vs. 6 or less) and stage (T3 vs. T1-2). Results: After a median follow up of 6.7 years and adjusting for known prognostic factors, there was a significant increase in the risk of PSA failure (HR, 2.3 [95% CI, 1.1-4.5; p = 0.025) in men with eMRI-defined TV progression during nAST. Specifically, adjusted estimates of PSA failure were significantly higher (p = 0.032) in men with, compared with men without, eMRI-defined TV progression reaching 38% vs. 19%, respectively, by 5 years. Conclusion: Eradicating intraprostatic hormone refractory prostate cancer (HRPC) by maximizing local control and randomized trials assessing whether survival is improved when agents active against HRPC are combined with maximal local therapy are needed in men who progress based on eMRI during nAST.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Parameters of the Corpora Cavernosa Do Not Correlate With Erectile Dysfunction After External Beam Radiotherapy for Prostate Cancer: Results From a Dose-Escalation Trial

Purpose: To analyze the correlation between dose-volume parameters of the corpora cavernosa and erectile dysfunction (ED) after external beam radiotherapy (EBRT) for prostate cancer. Methods and Materials: Between June 1997 and February 2003, a randomized dose-escalation trial comparing 68 Gy and 78 Gy was conducted. Patients at our institute were asked to participate in an additional part of the trial evaluating sexual function. After exclusion of patients with less than 2 years of follow-up, ED at baseline, or treatment with hormonal therapy, 96 patients were eligible. The proximal corpora cavernosa (crura), the superiormost 1-cm segment of the crura, and the penile bulb were contoured on the planning computed tomography scan and dose-volume parameters were calculated. Results: Two years after EBRT, 35 of the 96 patients had developed ED. No statistically significant correlations between ED 2 years after EBRT and dose-volume parameters of the crura, the superiormost 1-cm segment of the crura, or the penile bulb were found. The few patients using potency aids typically indicated to have ED. Conclusion: No correlation was found between ED after EBRT for prostate cancer and radiation dose to the crura or penile bulb. The present study is the largest study evaluating the correlation between ED and radiation dose to the corpora cavernosa after EBRT for prostate cancer. Until there is clear evidence that sparing the penile bulb or crura will reduce ED after EBRT, we advise to be careful in sparing these structures, especially when this involves reducing treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of Conformal Radiotherapy for Prostate Cancer: Impact of Dose Escalation on Biochemical Tumor Control and Distant Metastases-Free Survival Outcomes

Purpose: To report prostate-specific antigen (PSA) relapse-free survival and distant metastases-free survival (DMFS) outcomes for patients with clinically localized prostate cancer treated with high-dose conformal radiotherapy. Methods and Materials: Between 1988 and 2004, a total of 2,047 patients with clinically localized prostate cancer were treated with three-dimensional conformal radiotherapy or intensity-modulated radiotherapy. Prescribed dose levels ranged from 66-86.4 Gy. Median follow-up was 6.6 years (range, 3-18 years). Results: Although no differences were noted among low-risk patients for the various dose groups, significant improvements were observed with higher doses for patients with intermediate- and high-risk features. In patients with intermediate-risk features, multivariate analysis showed that radiation dose was an important predictor for improved PSA relapse-free survival (p < 0.0001) and improved DMFS (p = 0.04). In patients with high-risk features, multivariate analysis showed that the following variables predict for improved PSA relapse-free survival: dose (p < 0.0001); age (p = 0.0005), and neoadjuvant-concurrent androgen deprivation therapy (ADT; p = 0.01). In this risk group, only higher radiation dose was an important predictor for improved DMFS (p = 0.04). Conclusions: High radiation dose levels were associated with improved biochemical tumor control and decreased risk of distant metastases. For high-risk patients, despite the delivery of high radiation dose levels, the use of ADT conferred an additional benefit for improved tumor control outcomes. We observed a benefit for ADT in high-risk patients who received higher doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase II Study of High-Dose-Rate Afterloading Brachytherapy as Monotherapy for the Treatment of Localized Prostate Cancer

Purpose: A Phase II dose escalation study has been undertaken to evaluate high-dose-rate brachytherapy (HDRBT) monotherapy for prostate cancer. Methods and Materials: A total of 110 patients have been entered, all with locally advanced cancer. Three dose levels have been used; 34 Gy in four fractions, 36 Gy in four fractions, and 31.5 Gy in three fractions. These equate to 226Gy{sub 1.5}, 252Gy{sub 1.5}, and 252Gy{sub 1.5}, respectively. Thirty patients have received 34 Gy, 25 received 36 Gy, and 55 patients received 31.5 Gy. Acute and late toxicity was analyzed using the International Prostate Symptom Score, and urologic and rectal events were scored using the Radiation Therapy Oncology Group/Common Terminology Criteria scoring systems. Results: Seven patients required urethral catheterization at 2 weeks; 3 receiving 34 Gy, 1 receiving 36 Gy, and 3 receiving 31.5 Gy. Only 3 patients remained catheterized at 12 weeks. Radiation Therapy Oncology Group 1 and 2 gastrointestinal toxicity at 2 weeks was seen in 61%, 68%, and 77%, respectively. Grade 3 bladder toxicity was seen in 2 patients at 6 months, 1 each from the 36 Gy and 31.5 Gy arms. One patient from the 31.5-Gy cohort reported Grade 2 bowel toxicity at 6 months. Prostate-specific antigen (PSA), stratified for androgen deprivation therapy (ADT) and no-ADT patients ranged from 16.1-22.9 {mu}g/L and 11.1-12.5 {mu}g/L, respectively. This fell at 12 months to 0.2-0.6 {mu}g/L and 0.5-1.4 {mu}g/L, respectively. No PSA relapses have yet been seen with a median follow-up of 30 months (34 Gy), 18 months (36 Gy), and 11.8 months (31.5 Gy). Conclusions: Early results suggest an excellent biochemical response with no differences seen in acute and late toxicity between doses of 34 Gy/four fractions, 36 Gy/four fractions, or 31.5 Gy/three fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adverse Effects of Androgen Deprivation Therapy on Persistent Genitourinary Complications After Carbon Ion Radiotherapy for Prostate Cancer

Purpose: To determine the risk factors for persistent late genitourinary (GU) morbidity after carbon ion radiotherapy (C-ion RT) for prostate cancer. Methods and Materials: Between April 2000 and November 2003, a Phase II study of 175 prostate cancer patients was performed to assess C-ion RT with a dose fractionation (66 Gray equivalent in 20 fractions) established from previous Phase I-II studies. The effects of the clinical and dosimetric parameters on the occurrence of persistent GU toxicity in 172 patients who survived for >18 months after C-ion RT were examined retrospectively. C-ion RT alone was performed for 33 low-risk patients, and 139 high-risk patients received C-ion RT combined with androgen deprivation therapy (ADT). Results: Grade 1 and 2 persistent GU toxicities developed in 36 (21%) and 3 (2%) patients, respectively. The use of long-course ADT ({>=}24 months) and acute GU toxicity were associated with the occurrence of persistent toxicity by multivariate analysis (p = 0.016 and p = 0.048, respectively), but short-course ADT (<24 months) had no effect on the development of toxicity (p = 0.35). The 5-year actuarial complication rate of 80 patients undergoing long-course ADT was 31.1%; the corresponding rate for the 92 patients who received no ADT or short-course ADT was 22.2%. Conclusion: Adverse effects with long-course ADT on persistent GU morbidity were observed in this study. Additional investigation is needed to identify suitable ADT administration according to risk groups, but long-course ADT should not be adopted for non-high-risk prostate cancer patients to reduce the GU toxicity rate with C-ion RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy as Primary Therapy for Prostate Cancer: Report on Acute Toxicity After Dose Escalation With Simultaneous Integrated Boost to Intraprostatic Lesion

Purpose: To report on the acute toxicity of a third escalation level using intensity-modulated radiotherapy for prostate cancer (PCa) and the acute toxicity resulting from delivery of a simultaneous integrated boost (SIB) to an intraprostatic lesion (IPL) detected on magnetic resonance imaging (MRI), with or without spectroscopy. Methods and Materials: Between January 2002 and March 2007, we treated 230 patients with intensity-modulated radiotherapy to a third escalation level as primary therapy for prostate cancer. If an IPL (defined by MRI or MRI plus spectroscopy) was present, a SIB was delivered to the IPL. To report on acute toxicity, patients were seen weekly during treatment and 1 and 3 months after treatment. Toxicity was scored using the Radiation Therapy Oncology Group toxicity scale, supplemented by an in-house-developed scoring system. Results: The median dose to the planning target volume was 78 Gy. An IPL was found in 118 patients. The median dose to the MRI-detected IPL and MRI plus spectroscopy-detected IPL was 81 Gy and 82 Gy, respectively. No Grade 3 or 4 acute gastrointestinal toxicity developed. Grade 2 acute gastrointestinal toxicity was present in 26 patients (11%). Grade 3 genitourinary toxicity was present in 15 patients (7%), and 95 patients developed Grade 2 acute genitourinary toxicity (41%). No statistically significant increase was found in Grade 2-3 acute gastrointestinal or genitourinary toxicity after a SIB to an IPL. Conclusion: The results of our study have shown that treatment-induced acute toxicity remains low when intensity-modulated radiotherapy to 80 Gy as primary therapy for prostate cancer is used. In addition, a SIB to an IPL did not increase the severity or incidence of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy of a Single Implant With Two Fractions Combined With External Beam Radiotherapy for Hormone-Naive Prostate Cancer

Purpose: To evaluate the preliminary outcomes of high-dose-rate (HDR) brachytherapy of a single implant with two fractions and external beam radiotherapy (EBRT) for hormone-naive prostate cancer. Methods and Materials: Between March 2000 and Sept 2003, a total of 53 patients with tumor Stage T1c-T3b N0 M0 prostate cancer were treated with HDR brachytherapy boost doses (7.5 Gy/fraction) and 50-Gy EBRT during a 5.5-week period. Median follow-up was 61 months. Patients were divided into groups with localized (T1c-T2b) and advanced disease (T3a-T3b). We used the American Society for Therapeutic Radiology and Oncology (ASTRO) definition for biochemical failure. According to recommendations of the Radiation Therapy Oncology Group-ASTRO Phoenix Consensus Conference, biochemical failure-free control rates (BF-FCRs) at 3 years were investigated as 2 years short of the median follow-up. Results: Between April 2000 and Sept 2007, Common Terminology Criteria for Adverse Events Version 2.0 late Grade 2 genitourinary and gastrointestinal toxicity rates were 0% and 3.8%, respectively. Erectile preservation was 25% at 5 years. Overall survival was 88.1% and cause-specific survival was 100%. At 3 years, ASTRO BF-FCRs of the localized and advanced groups were 100% and 42%, respectively (p = 0.001). Conclusions: The HDR brachytherapy of a single implant with two fractions plus EBRT is effective in treating patients with localized hormone-naive prostate cancer, with the least genitourinary and gastrointestinal toxicities; however, longer median BF-FCR follow-up is required to assess these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does Image-Guided Radiotherapy Improve Toxicity Profile in Whole Pelvic-Treated High-Risk Prostate Cancer? Comparison Between IG-IMRT and IMRT

Purpose: To evaluate the impact of adding image-guided (IG) technique to intensity-modulated radiotherapy (IMRT) on dosimetric avoidance of organs at risk (OAR) and acute toxicities. Methods and Materials: A total of 25 consecutively treated patients (10 from National University Hospital and 15 from University of California San Francisco) with high-risk prostate cancer formed the study cohort. All received definitive IMRT with prophylactic nodal RT. Similar IMRT contouring and planning techniques were used at both centers. At University of California, San Francisco, intraprostatic fiducial markers were used for daily pretreatment on-line corrections (IG-IMRT). In contrast, at the National University Hospital, no fiducial markers were used (IMRT). At University of California, San Francisco, the planning target volume margins to the prostate were 2-3 mm. At the National University Hospital, they were 1 cm circumferentially, except for 0.5 cm posteriorly. The acute rectal and bladder toxicities and dosimetric endpoints to the planning target volume and organs at risk were compared. Results: The planning target volume dose coverage was not significantly different between IMRT and IG-IMRT for the prostate, seminal vesicles, and lymph nodes. The volume of rectum and bladder receiving {>=}40, {>=}60, and {>=}70 Gy were all significantly less using IG-IMRT (p <0.001). IG-IMRT yielded lower acute Radiation Therapy Oncology Group Grade 2 rectal (80% vs. 13%, p = 0.004) and bladder (60% vs. 13%, p = 0.014) toxicities. Conclusions: IG-IMRT, using daily target localization with fiducial markers, permits the use of smaller margins and correspondingly lower doses to the organs at risk, such as the rectum and bladder. These tangible gains appear to translate into lower clinically significant toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anorectal Function After Three- Versus Two-Dimensional Radiation Therapy for Carcinoma of the Prostate

Purpose: To compare the effects of (three-dimensional) 3D vs. two-dimensional (2D) radiation therapy (RT) for carcinoma of the prostate on the prevalence and pathophysiology of anorectal dysfunction. Methods and Materials: Anorectal symptoms, motility, sensory function, and anal sphincter morphology were evaluated before and up to 2 years after randomly assigned hypofractionated vs. conventionally fractionated RT in 67 patients (median age, 69 years; range, 54-82 years) with localized prostate carcinoma, using either a 3D (n = 29) or 2D (n = 38) treatment technique. Results: Anorectal symptoms increased 4 to 6 weeks after RT and persisted in both patient groups. At 2 years, abnormalities included increased stool frequency (55% vs. 53%, p = NS), urgency of defecation (72% vs. 47%, p < 0.05), fecal incontinence (28% vs. 26%, p = NS), and rectal bleeding (38% and 42%, p = NS). Anorectal motility and sensory function deteriorated after RT in both groups with reductions in basal anal pressures, anal pressures in response to squeeze, rectal compliance, and rectal volumes associated with the desire to defecate. External but not internal sphincter thickness changed in the treatment groups although in different directions. However no differences in motility or sensory function were detected between the groups. Baseline anorectal motility but not treatment technique and the hypofracionated schedule were of independent prognostic significance for anorectal motor dysfunction and rectal bleeding respectively at 2 years. Conclusion: The prevalence and pathophysiology of anorectal dysfunction 2 years after RT for prostate carcinoma was largely independent of the treatment techniques used in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical and Dosimetric Predictors of Acute Toxicity After a 4-Week Hypofractionated External Beam Radiotherapy Regimen for Prostate Cancer: Results From a Multicentric Prospective Trial

Purpose: To investigate predictors for gastrointestinal (GI) and genitourinary (GU) acute toxicity after a short-course hypofractionated radiotherapy regimen for prostate cancer. Materials and Methods: Three institutions included 102 patients with T1-T3N0M0 prostate cancer in a Phase II study. Patients were treated with 56 Gy in 16 fractions over 4 weeks. Acute toxicity was scored weekly during treatment and 1 and 2 months after treatment using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria extended with additional symptoms and the International Prostate Symptom Index (IPSS). Correlation with a number of clinical and dosimetric parameters was assessed by univariate and multivariate analyses. Results: No Grade 3 or 4 GI side effects were observed. Grades 1 and 2 rectal GI toxicity occurred in 36%, and 38%, respectively. Corresponding figures for Grades 1 and 2 GU toxicity were 42% and 39%, respectively. Grade 3 or higher GU toxicity was detected in 4% of patients. In multivariate analysis, percent rectal volumes higher than 8% receiving doses {>=}53 Gy (V{sub 53}) were statistically correlated to Grade 2 acute rectal reaction (p = 0.006). For GU morbidity, only the IPSS pretreatment score was independently associated (p = 0.0036) with an increase in GU acute effects. Conclusions: Acute GU and GI toxicity were comparable with other series. Our data show that increased incidence and intensity of acute toxicity is a transient effect related to shorter overall treatment time rather than a larger effect in biological equivalent dose with respect to a conventional fractionation regime.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment Endorectal Magnetic Resonance Imaging and Magnetic Resonance Spectroscopic Imaging Features of Prostate Cancer as Predictors of Response to External Beam Radiotherapy

Purpose: To evaluate whether pretreatment combined endorectal magnetic resonance imaging (MRI) and magnetic resonance spectroscopic imaging (MRSI) findings are predictive of outcome in patients who undergo external beam radiotherapy for prostate cancer. Methods and Materials: We retrospectively identified 67 men with biopsy-proven prostate cancer who underwent combined endorectal MRI and MRSI at our institution between January 1998 and October 2003 before whole-pelvis external beam radiotherapy. A single reader recorded tumor presence, stage, and metabolic abnormality at combined MRI and MRSI. Kaplan-Meier survival and Cox univariate and multivariate analyses explored the relationship between clinical and imaging variables and outcome, using biochemical or metastatic failure as endpoints. Results: After a mean follow-up of 44 months (range, 3-96), 6 patients developed both metastatic and biochemical failure, with an additional 13 patients developing biochemical failure alone. Multivariate Cox analysis demonstrated that the only independent predictor of biochemical failure was the volume of malignant metabolism on MRSI (hazard ratio [HR] 1.63, 95% confidence interval [CI] 1.29-2.06; p < 0.0001). The two independent predictors of metastatic failure were MRI tumor size (HR 1.34, 95% CI 1.03-1.73; p = 0.028) and the finding of seminal vesicle invasion on MRI (HR 28.05, 95% CI 3.96-198.67; p = 0.0008). Conclusions: In multivariate analysis, MRI and MRSI findings before EBRT in patients with prostate cancer are more accurate independent predictors of outcome than clinical variables, and in particular, the findings of seminal vesicle invasion and extensive tumor predict a worse prognosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Intensity-Modulated Radiotherapy in Reducing Toxicity in Dose Escalation for Localized Prostate Cancer

Purpose: To compare the acute and late gastrointestinal (GI) and genitourinary (GU) toxicity in prostate cancer patients treated to a total dose of 78 Gy with either a three-conformal radiotherapy technique with a sequential boost (SEQ) or a simultaneous integrated boost using intensity-modulated radiotherapy (SIB-IMRT). Patients and Methods: A total of 78 prostate cancer patients participating in the randomized Dutch trial comparing 68 Gy and 78 Gy were the subject of this analysis. They were all treated at the same institution to a total dose of 78 Gy. The median follow-up was 76 and 56 months for the SEQ and SIB-IMRT groups, respectively. The primary endpoints were acute and late GI and GU toxicity. Results: A significantly lower incidence of acute Grade 2 or greater GI toxicity occurred in patients treated with SIB-IMRT compared with SEQ (20% vs. 61%, p = 0.001). For acute GU toxicity and late GI and GU toxicity, the incidence was lower after SIB-IMRT, but these differences were not statistically significant. No statistically significant difference were found in the 5-year freedom from biochemical failure rate (Phoenix definition) between the two groups (70% for the SIB-IMRT group vs. 61% for the SEQ group, p = 0.3). The same was true for the 5-year freedom from clinical failure rate (90% vs. 72%, p = 0.07). Conclusion: The results of our study have shown that SIB-IMRT reduced the toxicity without compromising the outcome in patients with localized prostate cancer treated to 78 Gy radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Observed Variance Between Predicted and Measured Radiation Dose in Breast and Prostate Patients Utilizing an In Vivo Dosimeter

Purpose: Report the results of using a permanently implantable dosimeter in radiation therapy: determine specific adverse events, degree of migration, and acquire dose measurements during treatment to determine difference between expected and measured dose. Methods and Materials: The Dose Verification System is a wireless, permanently implantable metal-oxide semiconductor field-effect transistor dosimeter using a bidirectional antenna for power and data transfer. The study cohort includes 36 breast (33 patients received two devices) and 29 prostate (21 patients received two devices) cancer patients. A total of 1,783 and 1,749 daily dose measurements were obtained on breast and prostate patients, respectively. The measurements were compared with the planned expected dose. Biweekly computed tomography scans were obtained to evaluate migration and the National Cancer Institute's Common Toxicity Criteria, version 3, was used to evaluate adverse events. Results: Only Grade I/II adverse events of pain and bleeding were noted. There were only four instances of dosimeter migration of >5 mm from known factors. A deviation of {>=}7% in cumulative dose was noted in 7 of 36 (19%) for breast cancer patients. In prostate cancer patients, a {>=}7% deviation was noted in 6 of 29 (21%) and 8 of 19 (42%) during initial and boost irradiation, respectively. The two patterns of dose deviation were random and systematic. Some causes for these differences could involve organ movement, patient movement, or treatment plan considerations. Conclusions: The Dose Verification System was not associated with significant adverse events or migration. The dosimeter can measure dose in situ on a daily basis. The accuracy and utility of the dose verification system complements current image-guided radiation therapy and intensity-modulated radiation therapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

There Is No Correlation Between Erectile Dysfunction and Dose to Penile Bulb and Neurovascular Bundles Following Real-Time Low-Dose-Rate Prostate Brachytherapy

Purpose: We evaluated the relationship between the onset of erectile dysfunction and dose to the penile bulb and neurovascular bundles (NVBs) after real-time ultrasound-guided prostate brachytherapy. Methods and Materials: One hundred forty-seven patients who underwent prostate brachytherapy met the following eligibility criteria: (1) treatment with {sup 125}I brachytherapy to a prescribed dose of 160 Gy with or without hormones without supplemental external beam radiation therapy, (2) identification as potent before the time of implantation based on a score of 2 or higher on the physician-assigned Mount Sinai Erectile Function Score and a score of 16 or higher on the abbreviated International Index of Erectile Function patient assessment, and (3) minimum follow-up of 12 months. Median follow-up was 25.7 months (range, 12-47 months). Results: The 3-year actuarial rate of impotence was 23% (34 of 147 patients). An additional 43% of potent patients (49 of 113 patients) were using a potency aid at last follow-up. The penile bulb volume receiving 100% of the prescription dose (V{sub 100}) ranged from 0-0.05 cc (median, 0 cc), with a dose to the hottest 5% (D{sub 5}) range of 12.5-97.9 Gy (median, 40.8 Gy). There was no correlation between penile bulb D{sub 5} or V{sub 100} and postimplantation impotency on actuarial analysis. For the combined right and left NVB structures, V{sub 100} range was 0.3-5.1 cc (median, 1.8 cc), and V{sub 150} range was 0-1.5 cc (median, 0.31 cc). There was no association between NVB V{sub 100} or V{sub 150} and postimplantation impotency on actuarial analysis. Conclusion: Penile bulb doses are low after real-time ultrasound-guided prostate brachytherapy. We found no correlation between dose to either the penile bulb or NVBs and the development of postimplantation impotency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RTOG GU Radiation Oncology Specialists Reach Consensus on Pelvic Lymph Node Volumes for High-Risk Prostate Cancer

Purpose: Radiation therapy to the pelvic lymph nodes in high-risk prostate cancer is required on several Radiation Therapy Oncology Group (RTOG) clinical trials. Based on a prior lymph node contouring project, we have shown significant disagreement in the definition of pelvic lymph node volumes among genitourinary radiation oncology specialists involved in developing and executing current RTOG trials. Materials and Methods: A consensus meeting was held on October 3, 2007, to reach agreement on pelvic lymph node volumes. Data were presented to address the lymph node drainage of the prostate. Extensive discussion ensued to develop clinical target volume (CTV) pelvic lymph node consensus. Results: Consensus was obtained resulting in computed tomography image-based pelvic lymph node CTVs. Based on this consensus, the pelvic lymph node volumes to be irradiated include: distal common iliac, presacral lymph nodes (S{sub 1}-S{sub 3}), external iliac lymph nodes, internal iliac lymph nodes, and obturator lymph nodes. Lymph node CTVs include the vessels (artery and vein) and a 7-mm radial margin being careful to 'carve out' bowel, bladder, bone, and muscle. Volumes begin at the L5/S1 interspace and end at the superior aspect of the pubic bone. Consensus on dose-volume histogram constraints for OARs was also attained. Conclusions: Consensus on pelvic lymph node CTVs for radiation therapy to address high-risk prostate cancer was attained and is available as web-based computed tomography images as well as a descriptive format through the RTOG. This will allow for uniformity in evaluating the benefit and risk of such treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Changes Resulting From Patient Rotational Setup Errors in Proton Therapy Prostate Plans

Purpose: To evaluate the dose changes to the target and critical structures from rotational setup errors in prostate cancer patients treated with proton therapy. Methods and Materials: A total of 70 plans were analyzed for 10 patients treated with parallel-opposed proton beams to a dose of 7,600 {sup 60}Co-cGy-equivalent (CcGE) in 200 CcGE fractions to the clinical target volume (i.e., prostate and proximal seminal vesicles). Rotational setup errors of +3{sup o}, -3 deg., +5 deg., and -5 deg. (to simulate pelvic tilt) were generated by adjusting the gantry. Horizontal couch shifts of +3 deg. and -3 deg. (to simulate longitudinal setup variability) were also generated. Verification plans were recomputed, keeping the same treatment parameters as the control. Results: All changes shown are for 38 fractions. The mean clinical target volume dose was 7,780 CcGE. The mean change in the clinical target volume dose in the worse case scenario for all shifts was 2 CcGE (absolute range in worst case scenario, 7,729-7,848 CcGE). The mean changes in the critical organ dose in the worst case scenario was 6 CcGE (bladder), 18 CcGE (rectum), 36 CcGE (anterior rectal wall), and 141 CcGE (femoral heads) for all plans. In general, the percentage of change in the worse case scenario for all shifts to the critical structures was <5%. Deviations in the absolute percentage of volume of organ receiving 45 and 70 Gy for the bladder and rectum were <2% for all plans. Conclusion: Patient rotational movements of 3 deg. and 5 deg. and horizontal couch shifts of 3 deg. in prostate proton planning did not confer clinically significant dose changes to the target volumes or critical structures00.

62 RADIOLOGY AND NUCLEAR MEDICINE↗