Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance analysis and profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom

In a radiotherapy center, daily quality assurance (QA) measurements are performed to ensure that the equipment can be safely used for patient treatment on that day. In a pencil beam scanning (PBS) proton therapy center, spot positioning, spot size, range, and dose output are usually verified every day before treatments. We designed, built, and tested a new, reliable, sensitive, and inexpensive phantom, coupled with an array of ionization chambers, for daily QA that reduces the execution times while preserving the reliability of the test. The phantom is provided with 2 pairs of wedges to sample the Bragg peak at different depths to have a transposition on the transverse plane of the depth dose. Three “boxes” are used to check spot positioning and delivered dose. The box thickness helps spread the single spot and to fit a Gaussian profile on a low resolution detector. We tested whether our new QA solution could detect errors larger than our action levels: 1 mm in spot positioning, 2 mm in range, and 10% in spot size. Execution time was also investigated. Our method is able to correctly detect 98% of spots that are actually in tolerance for spot positioning and 99% of spots out of 1 mm tolerance. All range variations greater than the threshold (2 mm) were correctly detected. The analysis performed over 1 month showed a very good repeatability of spot characteristics. The time taken to perform the daily quality assurance is 20 minutes, a half of the execution time of the former multidevice procedure. This “in-house build” phantom substitutes 2 very expensive detectors (a multilayer ionization chamber [MLIC] and a strip chamber, reducing by 5 times the cost of the equipment. We designed, built, and validated a phantom that allows for accurate, sensitive, fast, and inexpensive daily QA procedures in proton therapy with PBS.

61 RADIATION PROTECTION AND DOSIMETRY↗

In Situ Observation of Ion Migration in a Ferroelectric Ionic Conductor Rb-KTP during Thermal Annealing

Ion exchange in Rb-doped KTiOPO 4 has facilitated significant advancements in ferroelectric domain engineering, yet understanding the underlying mechanisms remains in its infancy. We perform time-of-flight secondary ion mass spectrometry analysis on multiple periodically ion-exchanged and periodically poled Rb-doped KTiOPO 4 samples under different temperatures and annealing durations. The results are compared between annealing in air, which involved ex situ annealing before periodic poling, and vacuum annealing conducted in situ after periodic poling. The Rb + diffusion profile after periodic ion exchange forms a tooth-shaped pattern. We show that in situ annealing causes a surface pinning effect on the nonpolar face, limiting Rb + migration along the polar axis at the surface. Once the pinned layer is removed through milling, the underlying Rb + diffusion is distinctively different from the surface. Additionally, the rate of Rb + diffusion during in situ annealing is linear, while the periodic domain structures remain stable after annealing. These results contribute to understanding the ionic diffusion process in a ferroelectric ionic conductor and using ion exchange to tailor the linear and nonlinear properties of KTiOPO 4 .

36 MATERIALS SCIENCE↗

Finite size effects in ferroelectric-semiconductor thin films under open-circuit electric boundary conditions

General features of finite size effects in the ferroelectric-semiconductor film under open-circuit electric boundary conditions are analyzed using Landau-Ginzburg-Devonshire theory and continuum media electrostatics. The temperature dependence of the film critical thickness, spontaneous polarization and depolarization field profiles of the open-circuited films are found to be significantly different from the characteristics of short-circuited ones. In particular, we predict the re-entrant type transition boundary between the mono-domain and poly-domain ferroelectric states due to reduced internal screening efficiency and analyzed possible experimental scenarios created by this mechanism. Performed analysis is relevant for the quantitative description of free-standing ferroelectric films phase diagrams and polar properties. Also our results can be useful for the explanation of the scanning-probe microscopy experiments on free ferroelectric surfaces.

36 MATERIALS SCIENCE↗

HipGISAXS : a high-performance computing code for simulating grazing-incidence X-ray scattering data

This article describes the development of a flexible grazing-incidence small-angle X-ray scattering (GISAXS) simulation code in the framework of the distorted wave Born approximation that effectively utilizes the parallel processing power provided by graphics processors and multicore processors. The code, entitled High-Performance GISAXS , computes the GISAXS image for any given superposition of user-defined custom shapes or morphologies in a material and for various grazing-incidence angles and sample orientations. These capabilities permit treatment of a wide range of possible sample structures, including multilayered polymer films and nanoparticles on top of or embedded in a substrate or polymer film layers. In cases where the material displays regions of significant refractive index contrast, an algorithm has been implemented to perform a slicing of the sample and compute the averaged refractive index profile to be used as the reference geometry of the unperturbed system. A number of case studies are presented, which demonstrate good agreement with the experimental data for a variety of polymer and hybrid polymer/nanoparticle composite materials. The parallelized simulation code is well suited for addressing the analysis efforts required by the increasing amounts of GISAXS data being produced by high-speed detectors and ultrafast light sources.

Chemistry↗

Internal Resistive Barriers Related to Zinc Diffusion During the Growth of Inverted Metamorphic Multijunction Solar Cells

Majority carrier barriers at heterointerfaces are a common source of non-linear resistance that hinders concentrator solar cell performance. The source of a particular barrier is often unclear in a multijunction device with numerous heterointerfaces. In this work, we demonstrate Zn-dopant diffusion during inverted metamorphic multijunction (IMM) device growth to be one key cause of internal barrier formation. Using an inverted GaAs/GaAs tandem solar cell with a high temperature annealing layer grown in between each subcell, we simulate the annealing conditions of a multijunction growth in a simplified structure. Through analysis of the device by secondary ion mass spectrometry (SIMS) and electrochemical capacitance-voltage profiling, we show that annealing causes Zn to diffuse out of the top cell Ga 0.5 In 0.5 P back surface field (BSF) and accumulate in the GaAs base. Through equilibrium band modeling, we show that the resultant doping profile forms an energetic barrier to hole flow in the valence band, which correlates with fill factor losses in the current-voltage curves measured under concentration. When we, instead, employ a C-doped Al 0.2 Ga 0.8 As BSF layer in the top cell, we do not observe evidence of a heterojunction barrier. We attribute this difference to the reduced diffusivity of carbon, confirmed by SIMS, as well as more favorable valence band offsets between GaAs and Al 0.2 Ga 0.8 As. Finally, we compare 5-junction IMM cells with Al 0.2 Ga 0.8 As:C and Ga 0.5 In 0.5 P:Zn BSF layers in the GaAs third junction, respectively, and show a significantly improved concentrator device performance when Al 0.2 Ga 0.8 As:C is employed. Lastly, we demonstrate the importance of designing annealing tolerance into multijunction structures that are subjected to extended annealing during growth.

14 SOLAR ENERGY↗

High-resolution wall temperature measurements with distributed fiber optic sensors

Conventional approaches of surface temperature measurement are often unreliable, and other methods may not be practical in closed, high-temperature spaces. In this study, surface temperature measurements of the cooling panel of a natural circulation facility were performed with fiber optic distributed temperature sensors (DTS). High resolution surface temperature profiles of the cooling panel were acquired under two steady experimental conditions, and compared with measurements performed with nearby thermocouples. The total measurement error of the DTS results presented has been estimated to be ±4.4 °C. The findings reflected herein show that these DTS can reasonably measure surface temperature when installed with the methods developed in this study. Through the analysis of the DTS data collected, the interesting behavior of the cooling panel was revealed, providing new insights on the system's behavior that may be beneficial to the design and optimization of such heat transfer devices. These sensors can also provide the measurement density necessary for validation efforts with highly-resolved prediction methods such as finite element analysis (FEA) or computational fluid dynamics (CFD).

47 OTHER INSTRUMENTATION↗

Deuterium retention and out-gassing from beryllium oxide on beryllium

We studied the desorption of D implanted into Be with a superficial oxide layer. We found that the different oxide thicknesses and implantation at different energies resulted in a strong variation of the fraction stopped within the oxide layer. Thermal desorption of D was subsequently performed, intermitted by nuclear reaction analysis for assessment of the D depth distributions and total retained amounts. Moreover, for the conditions, where part of the D was deposited in the Be substrate, a sharp decrease of the retained amount of D occurs around 200 °C. This is attributed to the release from metallic Be. Correspondingly, the D and O depth profiles show that above 200 °C the remaining D is only retained in the BeO layer. Apparently, the superficial BeO layer does not act as a diffusion barrier for D that is released from the metallic substrate. The retained amount of D deposited within the BeO layer decreases steadily and is not completely released at 350 °C, the foreseen bake-out temperature in ITER.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of the CAM6 Climate Model Using Cloud Observations at McMurdo Station, Antarctica

A comparative analysis between observational data from McMurdo Station, Antarctica and the Community Atmosphere Model version 6 (CAM6) simulation is performed focusing on cloud characteristics and their thermodynamic conditions. Ka-band Zenith Radar (KAZR) and High Spectral Resolution Lidar (HSRL) retrievals are used as the basis of cloud fraction and cloud phase identifications. Radiosondes released at 12-hour increments provide atmospheric profiles for evaluating the simulated thermodynamic conditions. Our findings show that the CAM6 simulation consistently overestimates (underestimates) cloud fraction above (below) 3 km in four seasons of a year. Normalized by total in-cloud samples, ice and mixed phase occurrence frequencies are underestimated and liquid phase frequency is overestimated by the model at cloud fractions above 0.6, while at cloud fractions below 0.6 ice phase frequency is overestimated and liquid-containing phase frequency is underestimated by the model. The cloud fraction biases are closely associated with concurrent biases in relative humidity (RH), i.e., high (low) RH biases above (below) 2 km. Frequencies of correctly simulating ice and liquid-containing phase increase when the absolute biases of RH decrease. Cloud fraction biases also show a positive correlation with RH biases. Water vapor mixing ratio biases are the primary contributor to RH biases, and hence, likely a key factor controlling the cloud biases. Finally, this diagnosis of the evident shortfalls of representations of cloud characteristics in CAM6 simulation at McMurdo Station brings new insight in improving the governing model physics therein.

54 ENVIRONMENTAL SCIENCES↗

Fermi LAT search for internal bremsstrahlung signatures from dark matter annihilation

A commonly encountered obstacle in indirect searches for galactic dark matter is how to disentangle possible signals from astrophysical backgrounds. Given that such signals are most likely subdominant, the search for pronounced spectral features plays a key role for indirect detection experiments; monochromatic gamma-ray lines or similar features related to internal bremsstrahlung, in particular, provide smoking gun signatures. We perform a dedicated search for the latter in the data taken by the Fermi gamma-ray space telescope during its first 43 months. To this end, we use a new adaptive procedure to select optimal target regions that takes into account both standard and contracted dark matter profiles. The behaviour of our statistical method is tested by a subsampling analysis of the full sky data and found to reproduce the theoretical expectations very well. The limits on the dark matter annihilation cross-section that we derive are stronger than what can be obtained from the observation of dwarf galaxies and, at least for the model considered here, collider searches. While these limits are still not quite strong enough to probe annihilation rates expected for thermally produced dark matter, future prospects to do so are very good. In fact, we already find a weak indication, with a significance of 3.1σ (4.3σ) when (not) taking into account the look-elsewhere effect, for an internal bremsstrahlung-like signal that would correspond to a dark matter mass of ∼150 GeV; the same signal is also well fitted by a gamma-ray line at around 130 GeV. Although this would be a fascinating possibility, we caution that a much more dedicated analysis and additional data will be necessary to rule out or confirm this option.

79 ASTRONOMY AND ASTROPHYSICS↗

Joint EM-NE-International Study of Glass Behavior over Geologic Time Scales - 12303

Vitrification has been chosen as the best demonstrated available technology for waste immobilization worldwide. To date, the contributions of physical and chemical processes controlling the long-term glass dissolution rate in geologic disposal remain uncertain, leading to a lack of international consensus on a rate law for glass corrosion. Existing rate laws have overcome uncertainty through conservatism, but a thorough mechanistic understanding of waste form durability in geologic environments would improve public and regulator confidence. If it is possible to take credit for the true durability of the waste form in repository system evaluations, then it is possible to design the repository with less conservatism with concomitant cost savings. To gain a fundamental understanding of the dissolution rate law, six nations have joined together to formulate a joint plan for collaborative research into the mechanisms controlling the long-term corrosion of glass. This report highlights the technical program plan behind the US portion of this effort, with an emphasis on the current understanding (and limitations) of several mechanistic theories for glass corrosion. Some recent results are presented to provide an example of the ongoing research. Atom probe tomography has been used to provide a high-resolution analysis of elemental concentration gradients present at the hydrated glass / pristine glass interface in SON68 after 25.75 years of corrosion in a simulated granitic groundwater at 90 deg. C. The most valuable result of these initial studies is the success of the technique. Characterization by APT had never been previously demonstrated for glass corrosion layers. The resolution of APT is a powerful addition to the tools with which we can investigate the mechanisms dominating glass corrosion. Some other key results of this study include the observation that the elemental interfacial width between the hydrated glass and pristine glass appears to be much sharper (∼2 nm for B, Na and Al) than had been previously measured using nanoSIMS (∼240 nm). It is not clear whether the APT analysis and nanoSIMS characterizations were possibly performed on topographically unique regions, or whether nanoSIMS overestimated the elemental width. However, the APT data seems very convincing that the elemental width can be much sharper than was previously thought. This result calls into question some of the assumptions made for the diffusion-control models of glass dissolution, since such a sharp profile would not match the diffusion coefficients used to date. Other results, such as the observation of apparently layered concentration profiles, show that gel evolution is not as simple as is currently assumed in nearly every model. This task is a good example of the collaborative nature of the I-TEAM effort. Based on experimental needs and differences in expertise, scientists from DOE and CEA worked together to change the level of understanding in the field. These types of interactions are nearly ubiquitous among the tasks in the technical program plan. With the excellence of the team in place and the willingness of the participants to work together for a common understanding, the stated goal of consensus on the mechanistic basis for radionuclide release from glass is well within reach. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Seasonal Reconfiguration of Electrical Distribution Systems to Mitigate the Impact of Electric Vehicle Charging

Power grids face challenges in their infrastructure related to the integration of electric vehicles (EV). In particular, EV charging stations may induce instability in key system parameters such as substantial voltage drops, active power losses, and transformer overload due to high demand during charging periods. This article presents a seasonal reconfiguration strategy based on the differential evolution (DE) algorithm, aimed at enhancing system performance under highly variable and stochastic load profiles, particularly those driven by EV charging. The DEA algorithm is hybridized with the find-union (FU) algorithm to efficiently ensure network radiality throughout the optimization process. The proposed methodology is validated on a hybrid distribution system composed of the IEEE 33-bus network, a modified IEEE 13-bus system, and a specific 13-bus microgrid. Results have demonstrated that seasonal reconfiguration significantly reduces active power losses and mitigates transformer loading during critical demand hours, thereby quantifiably increasing the system’s performance. As an integral component of the proposed approach, an analysis of CO2 emissions associated with energy losses is included, allowing a contextualized assessment of the environmental benefits of seasonal reconfiguration in various geographical areas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TU-A-9A-02: Analysis of Variations in Clinical Doppler Ultrasound Peak Velocity Measurements

Purpose: Doppler ultrasound (US) peak velocity (Vmax) measurements show considerable variations due to intrinsic spectral broadening with different scanning techniques, machines and manufacturers. We developed a semi-automated Vmax estimation method and used this method to investigate the performance of a US system for clinical Doppler Vmax measurement. Methods: Semi-automated Vmax is defined as the velocity at which the computed mean spectral profile falls to within 1 background standard deviation of the background mean. GE LOGIQ E9 system with 9L and ML6-15 probes were studied with steady flow (5.3 – 12.5 ml/s) in a Gammex OPTIMIZER 1425A phantom. All Doppler spectra were acquired by 1 operator at the distal end of 5 mm angular tube using a modified clinical carotid artery protocol. Repeatability and variation of Vmax to scanning parameters and probes were analyzed and reported as percentage, i.e. (max-min)/mean. Results: Vmax estimation had good repeatability (3.1% over 6 days for 9L, and 3.6% for ML6-15). For 9L probe, varying gain, compression, scale, SV depth and length, and frequency had minimal impact on Vmax (all variations less than 4.0%). Beam steering had slightly higher influence (largest variations across flow rates were 4.9% for 9L and 6.9% for ML6-15). For both probes, Doppler angle had the greatest effect on Vmax. Percentage increase of Vmax was largely independent of actual flow rates. For Doppler angle varied from 30 to 60°, Vmax increased 24% for 9L, and 20% for ML6-15. Vmax measured by ML6-15 were lower than that by 9L at each Doppler angle with differences less than 5%. Conclusion: The proposed Vmax estimation method is shown to be a useful tool to evaluate clinical Doppler US system performance. For the tested system and probes, Doppler angle had largest impact in measured Vmax.

42 ENGINEERING↗

Using Radial Basis Functions to Approximate Battery Differential Capacity and Differential Voltage

As part of the Department of Energy’s Applied Battery Research Program, lithium-ion cells of various sizes and chemistries are aged with periodic reference performance tests to ascertain degradation rates. The reference tests included a very slow discharge and charge based on a constant current equal to 1/25th of the rated capacity to elucidate the true electrochemical capacity of the cell. A differential analysis of these data helps to identify the individual kinetic and thermodynamic contributions of the anode and cathode. However, differential curves are very noisy, and previous smoothing methods included simple data reduction and moving averages. This paper introduces an alternative method of finding the differential voltage and differential capacity curves based on radial basis functions. The voltage profile is fit with a number of Gaussian curves, and the resulting model is differentiated. This approach also has the added advantage of assessing model uncertainty based on a bootstrap analysis. The radial basis function method was successfully applied to various lithium-ion chemistries tested under the Applied Battery Research Program. The resulting differential capacity and differential voltage curves were generally smoother than the corresponding curves found by previous methods and also showed little variance, indicating a good model fit. These results imply that the radial basis function technique is a more robust tool for assessing differential data.

25 ENERGY STORAGE↗

MO-FG-202-04: Gantry-Resolved Linac QA for VMAT: A Comprehensive and Efficient System Using An Electronic Portal Imaging Device

Purpose: To automate gantry-resolved linear accelerator (linac) quality assurance (QA) for volumetric modulated arc therapy (VMAT) using an electronic portal imaging device (EPID). Methods: A QA system for VMAT was developed that uses an EPID, frame-grabber assembly and in-house developed image processing software. The system relies solely on the analysis of EPID image frames acquired without the presence of a phantom. Images were acquired at 8.41 frames per second using a frame grabber and ancillary acquisition computer. Each image frame was tagged with a gantry angle from the linac’s on-board gantry angle encoder. Arc-dynamic QA plans were designed to assess the performance of each individual linac component during VMAT. By analysing each image frame acquired during the QA deliveries the following eight machine performance characteristics were measured as a function of gantry angle: MLC positional accuracy, MLC speed constancy, MLC acceleration constancy, MLC-gantry synchronisation, beam profile constancy, dose rate constancy, gantry speed constancy, dose-gantry angle synchronisation and mechanical sag. All tests were performed on a Varian iX linear accelerator equipped with a 120 leaf Millennium MLC and an aS1000 EPID (Varian Medical Systems, Palo Alto, CA, USA). Results: Machine performance parameters were measured as a function of gantry angle using EPID imaging and compared to machine log files and the treatment plan. Data acquisition is currently underway at 3 centres, incorporating 7 treatment units, at 2 weekly measurement intervals. Conclusion: The proposed system can be applied for streamlined linac QA and commissioning for VMAT. The set of test plans developed can be used to assess the performance of each individual components of the treatment machine during VMAT deliveries as a function of gantry angle. The methodology does not require the setup of any additional phantom or measurement equipment and the analysis is fully automated to allow for regular routine testing.

60 APPLIED LIFE SCIENCES↗

Accurate argon cluster-ion sputter yields: Measured yields and effect of the sputter threshold in practical depth-profiling by x-ray photoelectron spectroscopy and secondary ion mass spectrometry

Argon Gas Cluster-Ion Beam sources are likely to become widely used on x-ray photoelectron spectroscopy and secondary ion mass spectrometry instruments in the next few years. At typical energies used for sputter depth profiling the average argon atom in the cluster has a kinetic energy comparable with the sputter threshold, meaning that for the first time in practical surface analysis a quantitative model of sputter yields near threshold is needed. We develop a simple equation based on a very simple model. Though greatly simplified it is likely to have realistic limiting behaviour and can be made useful for estimating sputter yields by fitting its three parameters to experimental data. We measure argon cluster-ion sputter yield using a quartz crystal microbalance close to the sputter threshold, for silicon dioxide, poly(methyl methacrylate), and polystyrene and (along with data for gold from the existing literature) perform least-squares fits of our new sputter yield equation to this data. The equation performs well, with smaller residuals than for earlier empirical models, but more importantly it is very easy to use in the design and quantification of sputter depth-profiling experiments.

36 MATERIALS SCIENCE↗

Cell-Type-Specific Proteomics Analysis of a Small Number of Plant Cells by Integrating Laser Capture Microdissection with a Nanodroplet Sample Processing Platform

Plant organs and tissues contain multiple cell types, which are well organized in 3-dimensional structure to efficiently perform physiological functions such as homeostasis, response to environmental perturbation, pathogen infection. It is critically important to perform molecular measurements at the cell-type-specific level to discover mechanisms and unique features of cell populations that govern differentiation and respond to external perturbations. Although mass spectrometry-based proteomics has been demonstrated as an enabling discovery tool to study plant physiology, conventional approaches require millions of cells to generate robust biological conclusions. Such requirements mask the cell-to-cell heterogeneities and limit the comprehensive profiling of plant proteins at spatially resolved and cell-type-specific resolutions. This protocol describes a recently-developed proteomics workflow for studying a small number of plant cells by integrating laser capture microdissection, microfluidic nanodroplet-based sample preparation, with ultrasensitive liquid chromatography-mass spectrometry. Using poplar as a model tree species, we provide detailed protocols, including plant tissue harvest, tissue preparation, cryosectioning, laser microdissection, protein digestion, mass spectrometry measurement, and data analysis. We show the workflow enables the precise identification and quantification of thousands of proteins from hundreds of isolated plant root and leaf cells.

59 BASIC BIOLOGICAL SCIENCES↗

Tandem column isolation of zirconium-89 from cyclotron bombarded yttrium targets using an automated fluidic platform: Anion exchange to hydroxamate resin columns

The development of a tandem column purification method for the production of high-purity 89Zr is presented. The primary column was a macroporous strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary column, with an internal volume of ~27 µL, was packed with hydroxamate resin. A condition of inverted selectivity was developed, whereby the 89Zr eluent from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89Zr. This approach assures delivery of high purity 89Zr product and assures a 89Zr product that is eluted in a substantially smaller volume than is possible when using the traditionally-employed single hydroxamate resin column method. The tandem column purification process has been implemented into a prototype automated fluidic system. The system is configured with on-line gamma detection so column effluents can be monitored in near-real time. The automated method was tested using seven cyclotron bombarded Y foil targets. It was found that 95.1±1.3% of the 89Zr present in the foils was recovered in the secondary column elution fraction. Furthermore, elution peak analysis of several 89Zr elution profile radiochromatograms made possible the determination of 89Zr recovery as a function of volume; a 89Zr product volume that contains 90% of the mean secondary column elution peak can be obtained in 0.29±0.06 mL (representing 86±5% of the 89Zr activity in the target). This product volume represents a significant increase in isotope product concentration over the predominant method used in the field. In addition to the reduced 89Zr product elution volume, titrations of the 89Zr product with deferoxamine mesylate salt across two preparatory methods resulted in mean effective specific activity (ESA) values of 279 and 340 TBq·mmole-1 and mean bindable metals concentrations ([MB]) of 13.5 and 16.7 nmole·g-1. These ESA and [MB] values infer that the 89Zr product resulting from this tandem column isolation method has the highest purity reported to date.

immunoPET, zirconium-89, laboratory automation, de↗

Merging Fungal and Bacterial Community Profiles via an Internal Control

Integrated measurements of fungi and bacteria are critical to understand how interactions between these taxa drive key processes in ecosystems ranging from soils to animal guts. High-throughput amplicon sequencing is commonly used to census microbiomes, but the genetic markers targeted for fungi and bacteria (typically ribosomal regions) are domain-specific so profiling must be performed separately, obscuring relationships between these groups. To solve this problem, we developed a spike-in method with an internal control (IC) construct containing primer sites commonly used for bacterial and fungal taxonomic profiling. The internal control offers several advantages: estimation of absolute abundances, estimation of fungal to bacterial ratios (F:B), integration of bacterial and fungal profiles for holistic community analysis, and lower costs compared to other quantitation methods. To validate the IC as a scaling method, we compared IC-derived measures of F:B to measures from quantitative PCR (qPCR) using a commercial mock community (the ZymoBiomic Microbial Community DNA Standard II, containing two fungi and eight bacteria) and complex environmental samples. For both the mock community and the environmental samples, the IC produced F:B values that were statistically consistent with qPCR. Merging the environmental fungal and bacterial profiles based on the IC-derived F:B values revealed new relationships among samples in terms of community similarity. As a result, this IC method is the first spike-in method to employ a single construct for cross-domain amplicon sequencing, offering more reliable measurements.

59 BASIC BIOLOGICAL SCIENCES↗