Effect of a Castillejo-Dalitz-Dyson pole in the pi-N I equals 1/2, J equals 1/2 super plus amplitude.
Phase shift analysis of nucleon-pion coupling, noting discrepancy between empirical and theoretical results
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Phase shift analysis of nucleon-pion coupling, noting discrepancy between empirical and theoretical results
The RHIC LLRF upgrade is a flexible, modular system. Output signals are generated by a custom designed XMC card with 4 high speed digital to analog (DAC) converters interfaced to a high performance field programmable gate array (FPGA). This paper discusses the hardware details of the XMC DAC board as well as the implementation of a low noise rf synthesizer with digital IQ modulation. This synthesizer also provides injection phase cogging and frequency hop rebucketing capabilities. A new modular RHIC LLRF system was recently designed and commissioned based on custom designed XMC cards. As part of that effort a high speed, four channel DAC board was designed. The board uses Maxim MAX5891 16 bit DACs with a maximum update rate of 600 Msps. Since this module is intended to be used for many different systems throughout the Collider Accelerator complex, it was designed to be as generic as possible. One major application of this DAC card is to implement digital synthesizers to provide drive signals to the various cavities at RHIC. Since RHIC is a storage ring with stores that typically last many hours, extremely low RF noise is a critical requirement. Synchrotron frequencies at RHIC range from a few hertz to several hundred hertz depending on the species and point in the acceleration cycle so close in phase noise is a major concern. The RHIC LLRF system uses the Update Link, a deterministic, high speed data link that broadcasts the revolution frequency and the synchronous phase angle. The digital synthesizers use this data to generate a properly phased analog drive signal. The synthesizers must also provide smooth phase shifts for cogging and support frequency shift rebucketing. One additional feature implemented in the FPGA is a digital waveform generator (WFG) that generates I and Q data pairs based on a user selected amplitude and phase profile as a function of time.
Detector circuit accurately separates and counts phase-shift pulses over wide range of basic pulse-rate frequency, and also provides reasonable representation of full repetitive EKG waveform. Single telemeter implanted in small animal monitors not only body temperature but also animal movement and heart rate.
The optical phase shift by reflection on graphene is measured by interference contrast microscopy. The height profile across graphene layers on 300 nm thick SiO{sub 2} on silicon is derived from the phase profile. The complex refractive index and conductivity of graphene layers on silicon with 2 nm thin SiO{sub 2} are evaluated from a phase profile, while the height profile of the layers is measured by atomic force microscopy. It is observed that the conductivity measured on thin SiO{sub 2} is significantly greater than on thick SiO{sub 2}. Back scattered electron contrast of graphene layers is correlated to the height of graphene layers.
With growing interest in EUV attenuated phase-shift masks due to their superior image quality for applications such as dense contact and pillar arrays, it is becoming critical to model, measure, and monitor the intensity and relative phase of multilayer and absorber reflections. We present a solution based on physical modeling of reflectometry data, which can achieve single picometer phase precision and sensitivity to changes in average film thickness below one atomic monolayer. We measure absorber and multilayer reflectivity to determine thin-film parameters with a multidimensional optimization and then acquire a new measurement of either multilayer or absorber to determine perturbations in surface contamination thickness. While it is difficult to assess the accuracy of the first step, the simplicity of the second step allows us to characterize our sensitivity to changes in contamination thickness. Thus, we apply this analysis using an initial set of measurements and repeated measurements after a period of storage. For the multilayer, the total contamination growth was 1068 pm, which occurred almost exclusively during storage (1085 pm) and decreased very slightly during repeated measurements (-17 pm). For the absorber, the behavior was quite different, with a total growth of 126 pm, which occurred much less during storage (28 pm) and primarily during repeated measurements (98 pm). Ultimately, the change in relative phase (absorber minus multilayer) was -0.86 deg for the multilayer and -1.12 deg for the absorber. We estimate the precision of the surface contamination measurement to be 3σ < 6 pm for measuring thickness and 3σ < 0.2 deg for measuring phase.
Spherically symmetrical classical scattering theory shows dependence on phase shift through appearance in quantal formulas for scattering amplitude and total cross section
Conference on proton, pion, and muon interactions - phase shift analyses of pion-nucleon and nucleon-nucleon scattering, charge distributions and pion decay into gamma rays
Radiative lifetimes of UV multiplets in Si, P, S, O, Ne 2 and Ar 2 measured via phase shift method, correcting for transition cascading
An observation from the Interface Region Imaging Spectrograph reveals coherent oscillations in the loops of an M1.6 flare on 2015 March 12. Both the intensity and Doppler shift of Fe xxi 1354.08 Å show clear oscillations with a period of ∼25 s. Remarkably similar oscillations were also detected in the soft X-ray flux recorded by the Geostationary Operational Environmental Satellites ( GOES ). With an estimated phase speed of ∼2420 km s{sup −1} and a derived electron density of at least 5.4 × 10{sup 10} cm{sup −3}, the observed short-period oscillation is most likely the global fast sausage mode of a hot flare loop. We find a phase shift of ∼ π /2 (1/4 period) between the Doppler shift oscillation and the intensity/ GOES oscillations, which is consistent with a recent forward modeling study of the sausage mode. The observed oscillation requires a density contrast between the flare loop and coronal background of a factor ≥42. The estimated phase speed of the global mode provides a lower limit of the Alfvén speed outside the flare loop. We also find an increase of the oscillation period, which might be caused by the separation of the loop footpoints with time.
Investigation of amplitude and phase shift of static pressure variations in supersonic diffuser for separate oscillation of spike and bypass
We investigate the influence of thermally activated internal molecular dynamics on the phase shifts of matter waves inside a molecule interferometer. While de Broglie physics generally describes only the center-of-mass motion of a quantum object, our experiment demonstrates that the translational quantum phase is sensitive to dynamic conformational state changes inside the diffracted molecules. The structural flexibility of tailor-made organic particles is sufficient to admit a mixture of strongly fluctuating dipole moments. These modify the electric susceptibility and through this the quantum interference pattern in the presence of an external electric field. Detailed molecular dynamics simulations combined with density-functional theory allow us to quantify the time-dependent structural reconfigurations and to predict the ensemble-averaged square of the dipole moment which is found to be in good agreement with the interferometric result. The experiment thus opens a different perspective on matter wave interferometry, as we demonstrate here that it is possible to collect structural information about molecules even if they are delocalized over more than 100 times their own diameter.
The first spectral numerical simulations of 16 orbits, merger, and ringdown of an equal-mass nonspinning binary black hole system are presented. Gravitational waveforms from these simulations have accumulated numerical phase errors through ringdown of < or approx. 0.1 radian when measured from the beginning of the simulation, and < or approx. 0.02 radian when waveforms are time and phase shifted to agree at the peak amplitude. The waveform seen by an observer at infinity is determined from waveforms computed at finite radii by an extrapolation process accurate to < or approx. 0.01 radian in phase. The phase difference between this waveform at infinity and the waveform measured at a finite radius of r=100M is about half a radian. The ratio of final mass to initial mass is M{sub f}/M=0.951 62{+-}0.000 02, and the final black hole spin is S{sub f}/M{sub f}{sup 2}=0.686 46{+-}0.000 04.
Phase shift values from polarization and elastic scattering data analysis
Comparison of different phase-shift analyses of 40 mev proton-alpha elastic scattering and polarization data
We present a general relativistic (GR) model of jet variability in active galactic nuclei due to orbiting blobs in helical motion along a funnel or cone-shaped magnetic surface anchored to the accretion disk near the black hole. Considering a radiation pressure driven flow in the inner region, we find that it stabilizes the flow, yielding Lorentz factors ranging between 1.1 and 7 at small radii for reasonable initial conditions. Assuming these as inputs, simulated light curves (LCs) for the funnel model include Doppler and gravitational shifts, aberration, light bending, and time delay. These LCs are studied for quasi-periodic oscillations (QPOs) and the power spectral density (PSD) shape, and yield an increased amplitude (∼12%), a beamed portion and a systematic phase shift with respect to that from a previous special relativistic model. The results strongly justify implementing a realistic magnetic surface geometry in Schwarzschild geometry to describe effects on emission from orbital features in the jet close to the horizon radius. A power-law-shaped PSD with a typical slope of −2 and QPOs with timescales in the range of (1.37–130.7) days consistent with optical variability in blazars, emerges from the simulations for black hole masses M{sub ∙}=(0.5−5)×10{sup 8} M{sub ⊙} and initial Lorentz factors γ{sub jet,i}=2−10. The models presented here can be applied to explain radio, optical, and X-ray variability from a range of jetted sources including active galactic nuclei, X-ray binaries, and neutron stars.
A multichannel three-wave far-infrared polarimeter-interferometer will be constructed on the J-TEXT tokamak (R=1.05 m, a=0.27 m, B{sub T}{<=}3 T, and I{sub P}{<=}350 kA) for current density profile and electron density profile measurements. The system will adopt the three-wave polarimeter configuration which was first introduced on RTP. Three 432.5 {mu}m HCOOH lasers pumped by three CO{sub 2} lasers separately will be adopted, which could generate high output power, nearly 50 mW at each cavity. Two of them will be counter-rotating circularly polarized to probe the Faraday angle, while the third laser will be used as a local oscillator to get the phase shift caused by electron density. Excellent port access (600x76 mm{sup 2}) and high laser power would promise a profile measurement across the whole plasma section with good signal quality. A high-speed digital phase comparator with a few ({approx}2) {mu}s temporal resolution will be developed, so that fast changes of current or density profile could be measured. Six channels will be installed in the first stage.
Contrast has traditionally been produced in electron-microscopy of weak phase objects by simply defocusing the objective lens. There now is renewed interest, however, in using devices that apply a uniform quarter-wave phase shift to the scattered electrons relative to the unscattered beam, or that generate in-focus image contrast in some other way. Renewed activity in making an electron-optical equivalent of the familiar “phase-contrast” light microscope is based in part on the improved possibilities that are now available for device microfabrication. There is also a better understanding that it is important to take full advantage of contrast that can be had at low spatial frequency when imaging large, macromolecular objects. In addition, a number of conceptually new phase-plate designs have been proposed, thus increasing the number of options that are available for development. The advantages, disadvantages, and current status of each of these options is now compared and contrasted. Experimental results that are, indeed, superior to what can be accomplished with defocus-based phase contrast have been obtained recently with two different designs of phase-contrast aperture. Nevertheless, extensive work also has shown that fabrication of such devices is inconsistent, and that their working lifetime is short. The main limitation, in fact, appears to be electrostatic charging of any device that is placed into the electron diffraction pattern. The challenge in fabricating phase plates that are practical to use for routine work in electron microscopy thus may be more in the area of materials science than in the area of electron optics.
Zernike phase contrast is a useful technique for nanoscale X-ray computed tomography (CT) imaging of materials with a low X-ray absorption coefficient. It enhances the image contrast by phase shifting X-ray waves to create changes in amplitude. However, it creates artifacts that hinder the use of traditional image segmentation techniques. We propose an image restoration method that models the X-ray phase contrast optics and the three-dimensional image reconstruction method. We generate artifact-free images through an optimization problem that inverts this model. Though similar approaches have been used for Zernike phase contrast in visible light microscopy, this optimization employs an effective edge detection method tailored to handle Zernike phase contrast artifacts. We characterize this optics-based restoration method by removing the artifacts in and thresholding multiple Zernike phase contrast X-ray CT images to produce segmented results that are consistent with the physical specimens. We quantitatively evaluate and compare our method to other segmentation techniques to demonstrate its high accuracy.