Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

EverGREEN 2045: An Energy Mix to Decarbonize Washington State

Washington State’s future resource mix is likely to be comprised of intermittent renewables and carbon-free generation including hydropower by 2045. Generation will likely be comprised of wind, solar photovoltaic (PV), batteries, pumped storage hydropower (PSH), existing nuclear power plants, and potentially enhanced geothermal systems and advanced nuclear reactor technologies. To assess the cost and stability of the future resource mix, we partner with X-energy (advanced reactor design) and AltaRock Energy (enhanced geothermal system) for proprietary cost data. After estimating the costs of these two new technologies, we design plausible future resource mix scenarios to meet Washington State’s Clean Energy Transformation Act which transitions the state to carbon-free generation by 2045. We assess the cost and stability of the future resource mix with power system analysis tools, finding revenues are sufficient to cover variable operating and maintenance costs for most technologies providing power in 2030 and 2045, but capacity payments or power purchase agreements will likely be necessary for flexible resources, including enhanced geothermal systems and advanced nuclear reactors, to participate in the future resource mix.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Life Cycle Analysis of Natural Gas Extraction and Power Generation: U.S. 2020 Emissions Profile

This analysis expands upon previous life cycle analyses (LCAs) of natural gas systems performed by the National Energy Technology Laboratory (NETL). It provides a complete inventory of emissions to air and water, water consumption, and land use change. These environmental burdens are detailed for all supply chain steps from natural gas production through natural gas distribution. This package includes the report, the NETL Natural Gas Model, and appendices that include several Excel workbooks and a python script to provide transparent access to the calculations and resulting data.<p>To access the NETL Natural Gas Lifecycle model, visit https://doi.org/10.18141/2476250.</p><p>To access the 2020 Report Appendices, visit https://doi.org/10.18141/2438472.</p>

03 NATURAL GAS↗

Life Cycle Analysis of Natural Gas Extraction and Power Generation: U.S. 2020 Emissions Profile

This analysis expands upon previous life cycle analyses (LCAs) of natural gas systems performed by the National Energy Technology Laboratory (NETL). It provides a complete inventory of emissions to air and water, water consumption, and land use change. These environmental burdens are detailed for all supply chain steps from natural gas production through natural gas distribution. This package includes the report, the NETL Natural Gas Model, and appendices that include several Excel workbooks and a python script to provide transparent access to the calculations and resulting data. This is revision 1 of the 2024 study (published December 17, 2024 and updated on January 24, 2025) and corrects a modeling error in natural gas composition. See the errata on page 2 for more information.

03 NATURAL GAS↗

Satellite Power Systems (SPS) space transportation cost analysis and evaluation

A picture of Space Power Systems space transportation costs at the present time is given with respect to accuracy as stated, reasonableness of the methods used, assumptions made, and uncertainty associated with the estimates. The approach used consists of examining space transportation costs from several perspectives to perform a variety of sensitivity analyses or reviews and examine the findings in terms of internal consistency and external comparison with analogous systems. These approaches are summarized as a theoretical and historical review including a review of stated and unstated assumptions used to derive the costs, and a performance or technical review. These reviews cover the overall transportation program as well as the individual vehicles proposed. The review of overall cost assumptions is the principal means used for estimating the cost uncertainty derived. The cost estimates used as the best current estimate are included.

Source record↗

Thermal analysis of heat storage canisters for a solar dynamic, space power system

A thermal analysis was performed of a thermal energy storage canister of a type suggested for use in a solar receiver for an orbiting Brayton cycle power system. Energy storage for the eclipse portion of the cycle is provided by the latent heat of a eutectic mixture of LiF and CaF2 contained in the canister. The chief motivation for the study is the prediction of vapor void effects on temperature profiles and the identification of possible differences between ground test data and projected behavior in microgravity. The first phase of this study is based on a two-dimensional, cylindrical coordinates model using an interim procedure for describing void behavor in 1-g and microgravity. The thermal analysis includes the effects of solidification front behavior, conduction in liquid/solid salt and canister materials, void growth and shrinkage, radiant heat transfer across the void, and convection in the melt due to Marangoni-induced flow and, in 1-g, flow due to density gradients. A number of significant differences between 1-g and o-g behavior were found. This resulted from differences in void location relative to the maximum heat flux and a significantly smaller effective conductance in 0-g due to the absence of gravity-induced convection.

Wichner, R. P.↗

Improved mesh based photon sampling techniques for neutron activation analysis

The design of fusion power systems requires analysis of neutron activation of large, complex volumes, and the resulting particles emitted from these volumes. Structured mesh-based discretization of these problems allows for improved modeling in these activation analysis problems. Finer discretization of these problems results in large computational costs, which drives the investigation of more efficient methods. Within an ad hoc subroutine of the Monte Carlo transport code MCNP, we implement sampling of voxels and photon energies for volumetric sources using the alias method. The alias method enables efficient sampling of a discrete probability distribution, and operates in 0(1) time, whereas the simpler direct discrete method requires 0(log(n)) time. By using the alias method, voxel sampling becomes a viable alternative to sampling space with the 0(1) approach of uniformly sampling the problem volume. Additionally, with voxel sampling it is straightforward to introduce biasing of volumetric sources, and we implement this biasing of voxels as an additional variance reduction technique that can be applied. We verify our implementation and compare the alias method, with and without biasing, to direct discrete sampling of voxels, and to uniform sampling. We study the behavior of source biasing in a second set of tests and find trends between improvements and source shape, material, and material density. Overall, however, the magnitude of improvements from source biasing appears to be limited. Future work will benefit from the implementation of efficient voxel sampling - particularly with conformal unstructured meshes where the uniform sampling approach cannot be applied. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal analysis of a conceptual design for a 250 We GPHS/FPSE space power system

A thermal analysis has been performed for a 250-We space nuclear power system which combines the US Department of Energy's general purpose heat source (GPHS) modules with a state-of-the-art free-piston Stirling engine (FPSE). The focus of the analysis is on the temperature of the indium fuel clad within the GPHS modules. The thermal analysis results indicate fuel clad temperatures slightly higher than the design goal temperature of 1573 K. The results are considered favorable due to numerous conservative assumptions used. To demonstrate the effects of the conservatism, a brief sensitivity analysis is performed in which a few of the key system parameters are varied to determine their effect on the fuel clad temperatures. It is shown that thermal analysis of a more detailed thermal mode should yield fuel clad temperatures below 1573 K.

Mccomas, Thomas J.↗

Power-Domain Impedance Theory for the Analysis and Mitigation of Interarea Oscillations: Preprint

This paper presents an impedance-based theory for the analysis and mitigation of interarea oscillations in power systems. Because low-frequency power system oscillations primarily manifest in phasor quantities, including active and reactive power flows, and the magnitude and frequency of bus voltages, a new-type of impedance, called power-domain impedance, is defined in terms of these phasor quantities. The power-domain impedance provides an intuitive framework for the analysis of interarea oscillations without requiring internal details of generators, and it is ideally suited for developing oscillation damping controls in inverter-based resources. The power-domain impedance theory is demonstrated in this paper using PSCAD simulations of a two-area system. The theory is also used for designing damping control in synchronous generators and a wind power plant in the two-area system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Imaging Power Losses in CdSeTe Solar Cells

Much of the research on CdSeTe photovoltaics is focused on improving the open-circuit voltage (V oc ) of the solar cell. But solar cells operate at the maximum power point (MPP) rather than at V oc . The recombination processes at MPP may be different than those at V oc , and increasing the power output at MPP is the key to advancing efficiency. Here, we introduce a camera-based PL imaging system that enables power loss analysis under operating conditions and across cm-sized areas covering multiple cells. The instrument is demonstrated with CdSeTe devices having efficiencies greater than 19%. An implied current density versus implied voltage (iJV) curve can be produced at each pixel with <20 µm resolution. We find that regions with high implied open circuit voltage are often those with low implied fill factor, showing that voltage loss analysis at open circuit is not sufficient to understand power losses under operating conditions. Measurement of JV curves as a function of irradiance can also be performed in the system, which allows series resistance-free pseudo JV (pJV) curves to be produced. Comparison of pJV to measured JV and iJV curves allows further analysis of the operational losses, pointing the way to higher efficiency.

14 SOLAR ENERGY↗

Impact analysis of DERs on bulk power system stability through the parameterization of aggregated DER_a model for real feeders

With an ever increasing percentage of distributed energy resources (DERs) connected behind the meter in the distribution system, it is becoming increasingly important to equip transmission planners with the visibility of DER dynamic performance in distribution system. Not having visibility of the disconnection of DERs with the occurrence of transmission events, could result in an erroneous view of the stability of bulk power system. Here, in this paper, a parameterized aggregated model (DER_a) serves as a representation of the distribution-level dynamics of real residential feeders, which is used for analysis of bulk power system stability. The parameters are obtained by executing dynamic Monte Carlo simulations. Faults are then induced at the substation level causing the DERs to trip which subsequently enables the parameterization of the low and high voltage breakpoints (v l0 , v l1 , v h0 , and v h1 ) of the DER_a model’s partial voltage trip block. These parameters are then utilized to study the effectiveness of the DER_a model to represent the behavior of the aggregated DERs’ response and their impact on the bulk power system. The case study shows the ability of the positive-sequence DER_a model to provide an accurate estimation of DERs that are susceptible to trip due to 3-$\phi$ and 1-$\phi$ faults of transmission.

14 SOLAR ENERGY↗

Visualizing Wind Farm Wakes Using SCADA Data

As wind farms scale to include more and more turbines, questions about turbine wake interactions become increasingly important. Turbine wakes reduce wind speed and downwind turbines suffer decreased performance. The cumulative effect of the wakes throughout a wind farm will therefore decrease the performance of the entire farm. These interactions are dynamic and complicated, and it is difficult to quantify the overall effect of the wakes. This problem has attracted some attention in terms of computational modelling for siting turbines on new farms, but less attention in terms of empirical studies and performance validation of existing farms. In this report, Supervisory Control and Data Acquisition (SCADA) data from an existing wind farm is analyzed in order to explore methods for documenting wake interactions. Visualization techniques are proposed and used to analyze wakes in a 67 turbine farm. The visualizations are based on directional analysis using power measurements, and can be considered to be normalized capacity factors below rated power. Wind speed measurements are not used in the analysis except for data pre-processing. Four wake effects are observed; including wake deficit, channel speed up, and two potentially new effects, single and multiple shear point speed up. In addition, an attempt is made to quantify wake losses using the same SCADA data. Power losses for the specific wind farm investigated are relatively low, estimated to be in the range of 3-5%. Finally, a simple model based on the wind farm geometrical layout is proposed. Key parameters for the model have been estimated by comparing wake profiles at different ranges and making some ad hoc assumptions. A preliminary comparison of six selected profiles shows excellent agreement with the model. Where discrepancies are observed, reasonable explanations can be found in multi-turbine speedup effects and landscape features, which are yet to be modelled.

17 WIND ENERGY↗

Small-Signal Stability Analysis of Low-Inertia Power Grids with Inverter-Based Resources and Synchronous Condensers: Preprint

With the potential environmental impacts of conventional fossil fuels and the technology advances of grid interactive power electronics, inverter-based resources (IBRs) are playing a crucial role in modern power grids. However, due to the lack of physical inertia, IBRs are vulnerable to system disturbances. Further, conventional grid-following (GFL) inverters cannot actively establish the frequency and voltage, which could not be a appropriate solution for 100% inverter-based power grids. Grid-forming (GFM) control, as an emerging inverter control function, has drawn great attention in recent years, while it is still under development and pre-mature for large-scale field deployment. A potential solution for gradually transitioning into a 100% inverter-based power grid is to combine both IBRs and synchronous machines into a mixed generation portfolio. More importantly, synchronous machines can be operated as synchronous condensers (SCs) until they are retired. It is also worth mentioning that the stability analysis is of great importance to ensure the smooth transition from existing power grids to 100% inverter-based system, which is the main focus of this work with detailed modeling and modal analysis.

100% renewable↗

Second law analysis of a conventional steam power plant

A numerical investigation of exergy destroyed by operation of a conventional steam power plant is computed via an exergy cascade. An order of magnitude analysis shows that exergy destruction is dominated by combustion and heat transfer across temperature differences inside the boiler, and conversion of energy entering the turbine/generator sets from thermal to electrical. Combustion and heat transfer inside the boiler accounts for 53.83 percent of the total exergy destruction. Converting thermal energy into electrical energy is responsible for 41.34 percent of the total exergy destruction. Heat transfer across the condenser accounts for 2.89 percent of the total exergy destruction. Fluid flow with friction is responsible for 0.50 percent of the total exergy destruction. The boiler feed pump turbine accounts for 0.25 percent of the total exergy destruction. Fluid flow mixing is responsible for 0.23 percent of the total exergy destruction. Other equipment including gland steam condenser, drain cooler, deaerator and heat exchangers are, in the aggregate, responsible for less than one percent of the total exergy destruction. An energy analysis is also given for comparison of exergy cascade to energy cascade. Efficiencies based on both the first law and second law of thermodynamics are calculated for a number of components and for the plant. The results show that high first law efficiency does not mean high second law efficiency. Therefore, the second law analysis has been proven to be a more powerful tool in pinpointing real losses. The procedure used to determine total exergy destruction and second law efficiency can be used in a conceptual design and parametric study to evaluate the performance of other steam power plants and other thermal systems.

Liu, Geng↗

A square multiflare horn with 1-megawatt CW power-handling capability

The analysis and low-power testing of a square multiflare horn designed for 1-megawatt CW operation is described. Design considerations for the five-port input section are discussed. The required aperture modes are determined from radiation pattern considerations, and analysis of the multiflare section is carried out using mode matching. Measurements demonstrate that a circularly symmetric beam is produced with relatively low sidelobes.

Hoppe, Dan↗

Dynamic analysis of rotor blade undergoing rotor power shutdown

A rigid flap-lag blade analysis was developed to simulate a rotor in a wind tunnel undergoing an emergency power shutdown. Results show that for a rotor at a nonzero shaft tilt angle undergoing an emergency power shutdown, the oscillatory lag response is divergent. The mean lag response is large when tested at high collective pitch angles. Reducing the collective pitch during the emergency shutdown reduces the steady lag response. Increasing the rotor shaft tilt angle increases the oscillatory lag response component. The blade lag response obtained by incorporating a nonlinear lag damper model indicates that in this case the equivalent linear viscous damping is lower than originally expected. Simulation results indicate that large oscillatory lag motions can be suppressed if the rotor shaft is returned to the fully vertical position during the emergency power shutdown.

Nguyen, Khanh Quoc↗

MEITNER Resource Team Modeling and Simulation Support to Holos-Quad Reactor Development (Final CRADA Report)

The main objective of this CRADA is to provide Argonne National Laboratory (ANL)’s modeling and simulation capabilities via ARPA-E's MEITNER (Modeling-Enhanced Innovations Trailblazing Nuclear Energy Reinvigoration) Resource Team (RT) arrangement to support the demonstration of the viability of HolosGen’s Holos-Quad reactor design. The Holos-Quad reactor design is an advanced reactor concept that incorporates many new design features, such as the neutron-coupled Subcritical Power Modules (SPMs) in its core design, elimination of balance of plant (BOP) by direct integration of a helium Brayton cycle power conversion system with each SPM, among many other innovative features. The demonstration of the viability of such an innovative reactor design warrants iterations of modeling and simulation and testing. The purpose of this project is to utilize ANL’s modeling and simulation capabilities in nuclear reactor analysis and power conversion system analysis to inform HolosGen and the Design Team (DT) in the design and optimization of the Holos-Quad concept. The major work scopes of this project include: to investigate conceptual designs and materials for radiation shielding to protect personnel and internal components such as turbomachinery; Assess the the helium Brayton cycle power conversion system performance in both nominal and load following conditions; Investigate power conversion components and overall system performance; Identify control strategies to enable load following; Perform simulations of HolosGen’s subscale simulator and using available test data for code validation/benchmark purpose; Perform core thermal-hydraulics, safety analysis, and structural analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of the inter-species power balance in JET plasmas

Most auxiliary heating methods provide heating to more than one particle species (electrons, ions, impurities) in a fusion plasma. This can lead to substantial temperature differences between species, depending on conditions such as heating power to the different species and collisionality, with temperature differences between species limited by inter-species thermal equipartition and transport. The analysis of the steady-state electron-ion and impurity-ion power balances presented in this paper are used for consistency-checking experimental ion and electron temperature measurements and for inferring the main ion temperature from measured impurity temperatures. As ion temperature measurements by charge exchange spectroscopy (CXS) based on impurity ions have become more difficult and time-consuming since the installation of the ITER-like wall (ILW) with Be and W PFC's, knowing the maximum sustainable temperature difference between ions and electrons, |T i -T e | allows rejecting erroneous measurements. It also obviates the need for an ion temperature measurement, if an electron temperature measurement is available and |T i - T e | cannot be larger than the combined errors of the underlying measurements. A power balance analysis is also required for estimating the errors of the ion and electron heat fluxes prior to any species-resolved transport analysis. The ion-impurity temperature differences are usually found to be small due to strong thermal equipartition between ion species. However, they can approach 10% in JET-ILW low density, high power discharges, such the ones under development for a future JET deuterium–tritium campaign (Joffrin et al 2019 Nucl. Fusion). This has a generally small, but not always negligible effect on the calculation of fusion reaction rates, which depend on main ion temperatures. An important outcome of this analysis is that temperature differences between impurity species are always much smaller than between the impurities and hydrogenic species and can usually be neglected. The article presents two methods for calculating the impurity-to-main ion temperature ratio. Finally, this analysis leads to a method for the reconstruction ion temperature profiles from ion temperature data available at only one or a small number of spatial locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗