Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Modeling Droplet Heat and Mass Transfer during Spray Bar Pressure Control of the Multipurpose Hydrogen Test Bed (MHTB) Tank in Normal Gravity

A CFD model for simulating pressure control in cryogenic storage tanks through the injection of a subcooled liquid into the ullage is presented and applied to the 1g MHTB spray bar cooling experiments. An Eulerian-Lagrangian approach is utilized to track the spray droplets and capture the interaction between the discrete droplets and the continuous ullage phase. The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. A new model for calculating the droplet-ullage heat and mass transfer is developed. In this model, a droplet is allowed to warm up to the saturation temperature corresponding to the ullage vapor pressure, after which it evaporates while remaining at the saturation temperature. The droplet model is validated against the results of the MHTB spray-bar cooling experiments with 50% and 90% tank fill ratios. The predictions of the present T-sat based model are compared with those of a previously developed kinetic-based droplet mass transfer model. The predictions of the two models regarding the evolving tank pressure and temperature distributions, as well as the droplets' trajectories and temperatures, are examined and compared in detail. Finally, the ullage pressure and local vapor and liquid temperature evolutions are validated against the corresponding data provided by the MHTB spray bar mixing experiment.

mass transfer↗

Inflatable Rings For Temporary Sealing

Inflatable rings seal joint. After inflation, space pressurized to test for leakage through joint. Rings protect surface of aperture from contact with metal structure of plug, and accommodate out-of-roundness and irregular surface contours without leaking. Pressure seal requires no preparation or cleanup.

Lesh, Paul L.↗

Module for Oxygenating Water without Generating Bubbles

A module that dissolves oxygen in water at concentrations approaching saturation, without generating bubbles of oxygen gas, has been developed as a prototype of improved oxygenators for water-disinfection and water-purification systems that utilize photocatalyzed redox reactions. Depending on the specific nature of a water-treatment system, it is desirable to prevent the formation of bubbles for one or more reasons: (1) Bubbles can remove some organic contaminants from the liquid phase to the gas phase, thereby introducing a gas-treatment problem that complicates the overall water-treatment problem; and/or (2) in some systems (e.g., those that must function in microgravity or in any orientation in normal Earth gravity), bubbles can interfere with the flow of the liquid phase. The present oxygenation module (see Figure 1) is a modified version of a commercial module that contains >100 hollow polypropylene fibers with a nominal pore size of 0.05 m and a total surface area of 0.5 m2. The module was originally designed for oxygenation in a bioreactor, with no water flowing around or inside the tubes. The modification, made to enable the use of the module to oxygenate flowing water, consisted mainly in the encapsulation of the fibers in a tube of Tygon polyvinyl chloride (PVC) with an inside diameter of 1 in. (approx.=25 mm). In operation, water is pumped along the insides of the hollow fibers and oxygen gas is supplied to the space outside the hollow tubes inside the PVC tube. In tests, the pressure drops of water and oxygen in the module were found to be close to zero at water-flow rates ranging up to 320 mL/min and oxygen-flow rates up to 27 mL/min. Under all test conditions, no bubbles were observed at the water outlet. In some tests, flow rates were chosen to obtain dissolved-oxygen concentrations between 25 and 31 parts per million (ppm) . approaching the saturation level of approx.=35 ppm at a temperature of 20 C and pressure of 1 atm (approx.=0.1 MPa). As one would expect, it was observed that the time needed to bring a flow of water from an initial low dissolved-oxygen concentration (e.g., 5 ppm) to a steady high dissolved-oxygen concentration at or near the saturation level depends on the rates of flow of both oxygen and water, among other things. Figure 2 shows the results of an experiment in which a greater flow of oxygen was used during the first few tens of minutes to bring the concentration up to approx.=25 ppm, then a lesser flow was used to maintain the concentration.

Gonzalez-Martin, Anuncia↗

Low-pressure combustion studies

Low pressure combustion instability tests on solid propellants, and pressure oscillation rate of depressurization

SOLID PROPELLANT↗

Experimental evaluation of the Skylab orbital workshop ventilation system concept

Extensive testing was conducted to evaluate the Orbital Workshop ventilation concept. Component tests were utilized to determine the relationship between operating characteristics at 1 and 0.34 atm. System tests were conducted at 1 atm within the Orbital Workshop full-scale mockup to assess delivered volumetric flow rate and compartment air velocities. Component tests with the Anemostat circular diffusers (plenum- and duct-mounted) demonstrated that the diffuser produced essentially equivalent airflow patterns and velocities in 1- and 0.34-atm environments. The tests also showed that the pressure drop across the diffuser could be scaled from 1 to 0.34 atm using the atmosphere pressure ratio. Fan tests indicated that the performance of a multiple, parallel-mounted fan cluster could be predicted by summing the single-fan flow rates at a given delta P.

Allums, S. L.↗

Arc-jet test and analysis of Orbiter TPS inter-tile heating in high pressure gradient flow

During entry of the Space Shuttle Orbiter, the convective heating within inter-tile gaps of the Thermal Protection System (TPS) material produces elevated tile sidewall temperatures in regions of high surface pressure gradient. Arc-jet tests have been conducted recently to obtain a measure of the gap heating down the TPS tile sidewalls at test conditions representative of Orbiter flight environments. The object of this paper is to present the gap heating correlations that were developed from a thermal analysis for 3-D curved and flat TPS tile segments. Predictions of gap sidewall temperature were obtained within 30 F of test data on both Wing Glove and Double Wedge models. Derived heating ratios were obtained for a range of test conditions (pressure, pressure gradient, enthalpy, boundary layer thickness, gap width, surface temperature, etc.). The results of the study, which showed that heating ratios varied with the pressure gradient times the square root of the surface pressure, are being used to provide an assessment of gap filler requirements on Orbiter forward fuselage/chine and wing glove regions.

Rochelle, W. C.↗

Shatter-Resistant, Flame-Resistant Window

Combustion-chamber window combines properties of polycarbonate and sapphire. Inner layer of sapphire, withstands flame in chamber. Outer layer of polycarbonate tough but susceptible to weakening by flame and protected from flame by sapphire layer. Resists flames, shattering, and high pressure. Windows withstand 60 lb/in. to second power (414 kPa) in hydrostatic pressure vessel. Also survives leak test under internal pressure of 2 atm (0.2 MPa) of helium and external pressure of 10 to negative fifth power torr (1.3 mPa). Has transmission density of 0.08 to 0.11 in visible light. In contrast, unbonded layers have transmission density of 0.13 to 0.16.

Richardson, William R.↗

Nonlinear and progressive failure aspects of transport composite fuselage damage tolerance

The purpose is to provide an end-user's perspective on the state of the art in life prediction and failure analysis by focusing on subsonic transport fuselage issues being addressed in the NASA/Boeing Advanced Technology Composite Aircraft Structure (ATCAS) contract and a related task-order contract. First, some discrepancies between the ATCAS tension-fracture test database and classical prediction methods is discussed, followed by an overview of material modeling work aimed at explaining some of these discrepancies. Finally, analysis efforts associated with a pressure-box test fixture are addressed, as an illustration of modeling complexities required to model and interpret tests.

Walker, Tom↗

Issues on Fabrication and Evaluation of SiC/SiC Tubes With Various Fiber Architectures

SiC/SiC engine components, high-modulus Sylramic-iBN SiC fiber tows were used to form nine different tubular architectural preforms with 13 mm (0.5 in.) inner diameter and lengths of approx. 75 and 230 mm (approx. 3 and approx, 9 in.). The thin-walled preforms were then coated with a BN interphase and densified with a hybrid SiC matrix using nearly the same process steps previously established for slurry-cast melt-infiltrated Sylramic-iBN/BN/SiC flat panels. The as-fabricated CMC tubes were microstructurally evaluated and tested for tensile hoop and flexural behavior, and some of the tubes were also tested in a low-pressure burner rig test with a high thru-thickness thermal gradient. To date, four general tube scale-up issues have been identified: greater CVI deposits on outer wall than inner wall; increased ply thickness and reduced fiber fraction; poor test standards for accurately determining the hoop strength of a small-diameter tube; and poor hoop strength for architectures with seams or ply ends. The underlying mechanisms and possible methods for their minimization are discussed.

Yun, H. M.↗

Liquid Methane/Liquid Oxygen Propellant Conditioning Feed System (PCFS) Test Rigs

As part of their Propulsion and Cryogenic Advanced Development (PCAD) program, NASA has embarked upon an effort to develop chemical rocket engines which utilize non-toxic, cryogenic propellants such as liquid oxygen (LO2) and liquid methane (LCH4). This effort includes the development and testing of a 100 lbf Reaction Control Engine (RCE) that will be used to evaluate the performance of a LO2/LCH4 rocket engine over a broad range of propellant temperatures and pressures. This testing will take place at NASA-Glenn Research Center's (GRC) Research Combustion Laboratory (RCL) test facility in Cleveland, OH, and is currently scheduled to begin in late 2008. While the initial tests will be performed at sea level, follow-on testing will be performed at NASA-GRC's Altitude Combustion Stand (ACS) for altitude testing. In support of these tests, Sierra Lobo, Inc. (SLI) has designed, developed, and fabricated two separate portable propellant feed systems under the Propellant Conditioning and Feed System (PCFS) task: one system for LCH4, and one for LO2. These systems will be capable of supplying propellants over a large range of conditions from highly densified to several hundred pounds per square inch (psi) saturated. This paper presents the details of the PCFS design and explores the full capability of these propellant feed systems.

Skaff, A.↗

Summary of Rocket-Model Tests at Zero Lift of the Northrop MX-775B Missile Configuration from Mach Numbers of 0.9 to 1.8

Flight tests were conducted between Mach numbers of 0.9 and 1.8 over a Reynolds number range of 9(exp 6) to 30(exp 6) to determine the zero-lift drag and some rolling-effectiveness characteristics of the Northrop MX -775B missile with small and large body. The MX-775B is a proposed long range, supersonic, ground-to-ground missile having an arrow wing with 67.5 degree leading-edge sweep, 15 deg trailing-edge sweep, and a modified NACA 0004 airfoil section. The configuration has no horizontal tail but has wing trailing-edge elevons which serve a dual purpose as elevators and ailerons. The ratio of body frontal area to wing plan-form area is 0.0127 for the small-body configuration and 0.0330 for the large-body configuration. Five 1/4-scale models were flown permitting determination of the drag coefficient for the basic small-body configuration, the incremental drag due to the large body, the incremental drag resulting from a blunt wing trailing edge, the wing-plus-interference drag, and some rolling-effectiveness data. Results indicated that the MX-775B has low supersonic zero-lift drag, the maximum zero-lift drag coefficients being respectively 0.0125 and 0.0155 at a Mach number of M = 1803 for the small- and large-body configurations. The effect of a blunt wing trailing edge, obtained by cutting off 10 percent of the wing chord, was to increase the zero-lift drag by 13 to 21 percent. Wing-plus-interference drag accounted for 78 percent of the total drag at M = 0.9 and 70 percent at M = 195 for the small-body configuration. The ailerons produced positive rolling effectiveness for the wing stiffness of the test models and the dynamic pressures of the test.

Arbic, Richard G.↗

Mechanical Properties and Durability of Advanced Environmental Barrier Coatings in Calcium-Magnesium-Alumino-Silicate Environments

Environmental barrier coatings are being developed and tested for use with SiC/SiC ceramic matrix composite (CMC) gas turbine engine components. Several oxide and silicate based compositons are being studied for use as top-coat and intermediate layers in a three or more layer environmental barrier coating system. Specifically, the room temperature Vickers-indentation-fracture-toughness testing and high-temperature stability reaction studies with Calcium Magnesium Alumino-Silicate (CMAS or "sand") are being conducted using advanced testing techniques such as high pressure burner rig tests as well as high heat flux laser tests.

Miladinovich, Daniel S.↗

NESC Ceramic Oxygen Generator (COG) Technology Development

The NASA Engineering and Safety Center (NESC) sponsored a project to accelerate the pace of technology development of a ceramic oxygen generator (COG), for NASA and COVID related medical use. NASA applications for this technology include spacesuit oxygen tank recharge, medical applications include providing medical oxygen in remote and low resource settings. During this project, five full-scale (i.e., 30 wafer) cell stacks were built and tested in prototype systems capable of producing pressurized oxygen. System testing measured oxygen product purity, delivery pressure, production rate, and energy use. This report describes ion transport membrane mechanisms, cell stack configuration, and test results.

Oxygen↗

Applying Flammability Limit Probabilities and the Normoxic Upward Limiting Pressure Concept to NASA STD-6001 Test 1

Repeated Test 1 extinction tests near the upward flammability limit are expected to follow a Poisson process trend. This Poisson process trend suggests that rather than define a ULOI and MOC (which requires two limits to be determined), it might be better to define a single upward limit as being where 1/e (where e (approx. equal to 2.7183) is the characteristic time of the normalized Poisson process) of the materials burn, or, rounding, where approximately 1/3 of the samples fail the test (and burn). Recognizing that spacecraft atmospheres will not bound the entire oxygen-pressure parameter space, but actually lie along the normoxic atmosphere control band, we can focus the materials flammability testing along this normoxic band. A Normoxic Upward Limiting Pressure (NULP) is defined that determines the minimum safe total pressure for a material within the constant partial pressure control band. Then, increasing this pressure limit by a factor of safety, we can define the material as being safe to use at the NULP + SF (where SF is on the order of 10 kilopascal, based on existing flammability data). It is recommended that the thickest material to be tested with the current Test 1 igniter should be 3 mm thick (1/8 inches) to avoid the problem of differentiating between an ignition limit and a true flammability limit.

flammability↗

Experimental study of the interaction between the wing of a subsonic aircraft and a nacelle of a high by-pass ratio engine

The oncoming of a new generation of subsonic transport aircraft (with supercritical wing and high by-pass ratio turbofans) led to an experimental study of wing nacelle jet pylon interference in transonic flow. To this end, a test set-up was developed at the ONERA S3Ch wind tunnel. The nacelle models represent a turbofan by means of two compressed air jets. The scale is 1/18.5. The nacelles are fixed on a thrust balance measuring afterbody thrust and discharge coefficients. The wing is located between the sidewalls of the test section. Pressures are measured through 456 holes located on 8 airfoils. Drag coefficient of the wing is obtained by wake survey. The following parameters can vary (1) wing/nacelle position; (2) upstream Mach number (from 0.3 to 0.8); (3) jet pressure ratio; (4) with/without pylon and (5) type of nacelle. Wing nacelle interference can be studied by means of total thrust drag analysis as a functon of the various parameters. The test set-up is described and examples of results are presented.

Levart, P.↗

High pressure gas scintillation drift chambers with wave shifter fiber readout. I

The authors present results from a prototype xenon-gas scintillation drift chamber. It was operated at pressures up to 20 atm, and the scintillation light yield was measured at various pressures and reduced fields. Scintillation-reduced fields ranged from 1.3 to 3 kV/cm/atm in a 5.4-mm scintillation gap. Drift fields ranged from 45 to 100 V/cm/atm in an 8-cm drift region. The chamber was exposed to an 241Am source in a port either 2.7 or 5.4 cm from the secondary scintillation region. The authors also describe the high-voltage problems encountered during operation at high pressures. Further tests with the wave shifter fiber readout showed that the problem of gas contamination by the fibers is manageable but that the interaction between the optical fibers and the high-pressure xenon gas can lead to fiber damage. A solution to this problem is described.

Parsons, A.↗