Search NASASearch

SEARCH · Search NASA

Results for “Probabilistic learning on manifold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,011 records · Page 47

High EneRgy Observatory for Imaging X-rays (HEROIX) Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) is a next-generation broadband X-ray space telescope concept under development as a Medium-Class Explorer mission. Building on more than three decades of replicated NiCo shell technology at NASA’s Marshall Space Flight Center, HEROIX will deliver 5 arcsecond half-power-diameter imaging resolution in the hard X-ray band. The observatory will incorporate four co-aligned telescopes with advanced multilayer coatings, extending the bandpass into the hard X-ray regime and providing an integrated effective area of 380 cm² at 30 keV. A suite of focal plane detectors will enable imaging capability throughout its 1–80 keV bandpass. This combination of angular resolution and high-energy coverage will open new windows into non-thermal processes in extreme astrophysical environments. HEROIXwill deliver transformative science, advancing the astrophysics community’s understanding of supernova physics, the X-ray binary population of the Galactic Center, accretion-driven galaxy evolution, and the origin of the Cosmic X-ray Background.

Nick Thomas

A nickel-cadmium battery reconditioning circuit

The circuit presented is simple and small enough to be included in a typical battery charge/power control assembly, yet provides the advantage of a complete ground-type battery reconditioning discharge. Test results on the circuit when used to recondition two 24 cell, 20 A-h nickel-cadmium batteries are given. These results show that a battery reconditioned with this circuit returns to greater than 90 percent of its original capacity (greater than nameplate capacity) and follows a typical new battery degradation curve even after over 20,000 simulated orbital cycles for a 4 year period. Applications of the circuit are considered along with recommendations relative to its use. Its application in low voltage (22 to 36 Vdc) power systems and in high voltage (100 to 150 Vdc) power systems is discussed. The implications are that the high voltage systems have a greater need for battery reconditioning than their low voltage counterparts, and that using these circuit techniques, the expected life of a battery in low Earth orbit can be up to 5 years.

Lanier, R.

Spacecraft thermal balance testing using infrared sources

A thermal balance test (controlled flux intensity) on a simple black dummy spacecraft using IR lamps was performed and evaluated, the latter being aimed specifically at thermal mathematical model (TMM) verification. For reference purposes the model was also subjected to a solar simulation test (SST). The results show that the temperature distributions measured during IR testing for two different model attitudes under steady state conditions are reproducible with a TMM. The TMM test data correlation is not as accurate for IRT as for SST. Using the standard deviation of the temperature difference distribution (analysis minus test) the SST data correlation is better by a factor of 1.8 to 2.5. The lower figure applies to the measured and the higher to the computer-generated IR flux intensity distribution. Techniques of lamp power control are presented. A continuing work program is described which is aimed at quantifying the differences between solar simulation and infrared techniques for a model representing the thermal radiating surfaces of a large communications spacecraft.

G. B. T. Tan

Nickel hydrogen battery expert system

The Hubble Telescope Battery Testbed at MSFC uses the Nickel Cadmium (NiCd) Battery Expert System (NICBES-2) which supports the evaluation of performance of Hubble Telescope spacecraft batteries and provides alarm diagnosis and action advice. NICBES-2 provides a reasoning system along with a battery domain knowledge base to achieve this battery health management function. An effort is summarized which was used to modify NICBES-2 to accommodate Nickel Hydrogen (NiH2) battery environment now in MSFC testbed. The NICBES-2 is implemented on a Sun Microsystem and is written in SunOS C and Quintus Prolog. The system now operates in a multitasking environment. NICBES-2 spawns three processes: serial port process (SPP); data handler process (DHP); and the expert system process (ESP) in order to process the telemetry data and provide the status and action advice. NICBES-2 performs orbit data gathering, data evaluation, alarm diagnosis and action advice and status and history display functions. The adaptation of NICBES-2 to work with NiH2 battery environment required modification to all of the three component processes.

Shiva, Sajjan G.

Radio Metric Errors Due to Mismatch and Offset Between a DSN Antenna Beam and the Beam of a Troposphere Calibration Instrument

Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10 -14 with a 4-deg beam and 1.3 x 10 -15 for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10 -14 over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.

R P Linfield

Aerodynamic Design of Axial Flow Compressors

An overview of 'Aerodynamic systems design of axial flow compressors' is presented. Numerous chapters cover topics such as compressor design, potential and viscous flow in two dimensional cascades, compressor stall and blade vibration, and compressor flow theory. Theoretical aspects of flow are also covered. This work is based substantially on a three-volume Confidential Research Memorandum f h t issued by the National Advisory Committee for Aeronautics in 1956 and declassified in .1958 for release to the general public. The material, which was of a fundamental character, has been updated for the present edition in the light of subsequent developments in the field and has been carefully reexamined for current validity by members of the staff of the NASA Lewis Research Center, Cleveland, Ohio. It is now published for the first time in a single volume to meet continuing demand for the information and to make it readily available in convenient form to the engineering community both within and outside the National Aeronautics and Space Administration.

Axial flow compressor

A Review of Medical Results of Gemini 7 and Related Flights

On August 23, 1966, a review of the medical findings of the fourteen day Gemini 7 mission and related flights was conducted. This review was organized at the request of Dr. George E. Mueller, Associate Administrator for Manned Space Flight, and consisted of presentations by the Principal Investigators of the Gemini Medical Flight Experiments and by the Director, Medical Research and Operations, Manned Spacecraft Center. This document is a compilation of the material presented at the review. The Principals cooperated most significantly by reviewing a transcription of a tape recording of their presentation, editing and providing a final version for publication. Without this most generous assistance, this document could not have been published. Table I, which follows immediately after this Introduction, is presented to acquaint the reader with the scope and sequence of medical measurements and experiments which were conducted during Project Gemini. This review was held prior to the conduct of the Gemini 11 and 12 missions, therefore, material derived from those flights is not included in this document.

E J McLaughlin

Dust Composition of Comet 81P/Wild 2 From JWST Spectroscopy Compared to Stardust’s Fine-Grained Materials and Gems-Rich IDPS

The Stardust Mission returned samples from the coma of Jupiter Family comet 81P/Wild 2 for detailed laboratory analyses. Here we present and discuss the best-fit thermal dust model for the coma dust of comet 81P/Wild 2 as observed by JWST. Comet 81P was observed through JWST GO 018xx, using NIRSpec (2.9–5.3µm, λ/∆λ≈1000) and MRS IFU (4.9–28.1µm, λ/∆λ≈3000) on 2023-03-20 UT and 2023-03-24 UT, respectively, at a heliocentric distance of 1.85 au and JWST distance of 1.43 au (phase angle of 32 degrees). The dust coma of 81P as revealed by JWST offers a salient compliment to laboratory studies of Stardust samples that typically are bigger than 2 µm and up to 60 µm in size.

D H Wooden

Report of the Microbial Development Working Group

In formulating ideas on the relationship of gravity to the development, growth, and reproduction of microorganisms, a rather liberal definition of microorganisms is used which includes bacteria, yeasts, protists, filamentous fungi, and single cells in culture. A principal advantage of microorganisms as experimental subjects is the rigor with which they can be defined and controlled. As single cells, each cell may be regarded as identical to the others in the population. This property applies to the morphology, physiology, and genetic parameters of the cells. The growth and development of the population is subject to precise manipulation as the nutritional requirements are known and minimal media formulations have been developed. Growth and differentiation can be manipulated in a variety of ways, such as alteration of the culture temperature and food supply, or by use of mutants. Finally, the short generation times of microorganisms provide the opportunity to conduct multigenerational studies within practical time limits and, in a similar vein, cellular responses to various stimuli or stresses are conveniently monitored because of the rapid response times of single cells.

G Nelson

Evaluation of Cycle Life and Characterization of YTP 45 Ah Li-Ion Battery for EMU

Li-ion batteries, with longer cycle life and higher energy density features, are now more and more attractive and applied in multiple fields. The YTP 45 Ah Li-ion battery has been evaluated here and may be employed in EMU in the future. Evaluations were on: (1) Cycle life tests - 500 cycles total (completed 40 cycles in simulated shuttle use mode and 460 cycles in an accelerated use mode, and recorded differential voltage of individual cell in battery); (2) Characterization test - discharge capacity measurement in environment temperature of -10, 25, 50 C before and after 500 cycles; and (3) Thermal testing - charge and discharge at 50 C and -10 C before and after 500 cycles. The battery showed less than a 9% drop of initial discharge capacity and energy within 500 cycles with 475 cycles 59% DOD plus 25 cycles 100% DOD. The EOD voltage ranged from 16.0 to 18.0 V, which fits the requirement for operating the EMU.

Deng, Yi

Surface Tension Driven Convection Experiment (STDCE)

Results are reported of the Surface Tension Driven Convection Experiment (STDCE) aboard the USML-1 (first United States Microgravity Laboratory) Spacelab which was launched on June 25, 1992. In the experiment 10 cSt silicone oil was placed in an open circular container which was 10 cm wide by 5 cm deep. The fluid was heated either by a cylindrical heater (1.11 cm dia.) located along the container centerline or by a CO 2 laser beam to induce thermocapillary flow. The flow field was studied by flow visualization. Several thermistor probes were placed in the fluid to measure the temperature distribution. The temperature distribution along the liquid free surface was measured by an infrared imager. Tests were conducted over a range of heating powers, laser beam diameters, and free surface shapes. In conjunction with the experiments an extensive numerical modeling of the flow was conducted. In this paper some results of the velocity and temperature measurements with flat and curved free surfaces are presented and they are shown to agree well with the numerical predictions.

S Ostrach

A Battery Certification Testbed for Small Satellite Missions

A battery pack consisting of standard cylindrical 18650 lithium-ion cells has been chosen for small satellite missions based on previous flight heritage and compliance with NASA battery safety requirements. However, for batteries that transit through the International Space Station (ISS), additional certification tests are required for individual cells as well as the battery packs. In this manuscript, we discuss the development of generalized testbeds for testing and certifying different types of batteries critical to small satellite missions. Test procedures developed and executed for this certification effort include: a detailed physical inspection before and after experiments; electrical cycling characterization at the cell and pack levels; battery-pack overcharge, over-discharge, external short testing; battery-pack vacuum leak and vibration testing. The overall goals of these certification procedures are to conform to requirements set forth by the agency and identify unique safety hazards. The testbeds, procedures, and experimental results are discussed for batteries chosen for small satellite missions to be launched from the ISS.

Certification

Next-Generation Hard X-ray Missions: SuperHERO and HEROIX

High-energy X-ray observations have transformed our understanding of astrophysical systems where non-thermal processes dominate, from shock-accelerated particles in supernova remnants to relativistic jets and hot coronae in active galactic nuclei. NuSTAR’s pioneering focusing images of the hard X-ray sky have demonstrated the immense scientific potential of this band, while also highlighting how limited angular resolution constrains our ability to fully characterize complex physical processes in faint extended sources and resolving faint sources in crowded sky regions. In this presentation, I will discuss a pathway to overcome these challenges through NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology. Specifically, I will discuss the SuperHERO hard X-ray telescope to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon flight observing the Crab Nebula, and the High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept to achieve an integrated effective area of 570 cm2 at 30 keV with 5 arcsec HPD angular resolution.

AGN

Diffusion Quantum Monte Carlo Calculation of the Austenite and Martensite Phases of NiTi

NiTi is a promising material for smart and active technologies due to its exhibition of the shape memory effect, superelasticity, and biocompatibility. The shape memory effect is tied to the reversible transition between the austenite and martensite phases. A major research direction is to alloy NiTi with Zr, Hf, Pd, Pt, etc., in order to tune the martensitic transition temperature (MTT). Modeling the MTT from first principles is challenging because the lattice dynamics is complicated by anharmonicity and various low-energy structures. Using density functional theory, the energy difference between the austenite and martensite phases of NiTi varies by up to 100 meV/atom depending on the choice of density functional, which is of the same order of the energy difference itself. Consequently, free energy calculations with different functionals can result in estimates of the MTT that vary by several hundred K. Using diffusion quantum Monte Carlo, we calculated the energy difference between the B2 and B19' structures of NiTi to be 70.9 +- 2.5 meV/atom.

Kevin K Ly

Softening the Gap between Wöhler and Paris – New Approaches for Fatigue Analysis –

Fatigue analysis tools can vary across industries. For example, automotive engineers often use the Wöhler (S-N) approach to design for safe-life, while aerospace engineers prioritize damage tolerance and inspection intervals, relying instead on crack growth models such as Paris’ law. Although both approaches may deal with the control of cracks in similar materials, their analysis tools and material characterizations are fundamentally distinct. This divide mirrors the classic split between stress-based strength analysis and linear elastic fracture mechanics. However, modern nonlinear models that incorporate material softening, such as cohesive laws, blur this boundary and capture fracture behaviors across scales. This presentation describes the CF23 fatigue model, which uses cohesive softening to link S-N crack initiation with crack propagation rates. CF23 spans the full fatigue spectrum, from initial propagation transients to steady-state growth and threshold conditions, offering a unified framework that bridges Wöhler and Paris-based methodologies. Example applications include fatigue crack propagation transients in adhesive interfaces and skin/stiffener separation.

cohesive elements

The 1977 Goddard Space Flight Center Battery Workshop

The papers presented were derived from transcripts taken at the Tenth Annual Battery Workshop held at the Goddard Space Flight Center, November 15-17, 1977. The Workshop was attended by manufacturers, users, and government representatives interested in the latest results of testing, analysis, and development of the sealed nickel cadmium cell system. The purpose of the Workshop was to share flight and test experience, stimulate discussion on problem areas, and to review the latest technology improvements.

G Halpert

Contaminant characterization of five satellite materials

An extensive laboratory test program was performed to characterize outgassing of five satellite materials. The materials were Chemglaze Z-306 over 9922 primer, M-773 adhesive, multilayer insulation, polyurethane foam, and silverized Teflon. The souces were prepared to the specifications of a typical satellite program. Dynamic thermogravimetric mass loss characteristics of these five materials were obtained in vacuum with a beam microbalance. The temperature of the material was linearly raised from 25 C to over 650 C while monitoring the mass loss, rate of mass loss, temperature, and the composition of the outgassed material by residual gas analysis. Isothermal source emission/capture coefficients/reemission parameters were obtained with an array of quartz crystal microbalances (QCM). A detailed test matrix in which the temperatures of the QCMs (-160 C, - 100 C, -40 C, and +10 C) and the source material (125 C, and 90 C, and 50 C) were varied was performed. The array of QCMs was also used to measure the spatial distribution of the source emission. The effects of vacuum ultraviolet radiation on the deposition and reemission parameters was determined.

J A Muscari

Test Results of a Ten Cell Bipolar Nickel-hydrogen Battery

A study was initiated to design and evaluate a new design concept for nickel-hydrogen cells. This concept involved constructing a battery in a bipolar stack with cells consisting of a one plate for each nickel and hydrogen electrode. Preliminary designs at the system level of this concept promised improvements in both volumetric and gravimetric energy densities, thermal management, life extension, costs, and peak power capability over more conventional designs. Test results were most encouraging. This preprototype battery, built with less than ideal components and hardware, exceeded expectations. A total of 2000 LEO cycles at 80 percent depth of discharge were accrued. A cycle life goal of 30,000 cycles appears achievable with minor design changes. These improvements include advanced technology nickel electrodes, insulated bipolar plates and specifically designed frames to minimize shunt currents. The discharge rate capability of this design exceeds 25C. At the 10C discharge rate, 80% of the battery capacity can be withdrawn in six minutes. This data shows that the bipolar design is well suited for those applications requiring high peak power pulses.

Cataldo, R. L.