SU-E-I-41: Non-Cartesian MR Image Reconstruction with Integrated Gradient Non-Linearity Correction

Purpose: Nonlinearities in the spatial encoding gradients of MRI systems cause geometric distortion in images. Typically, this is retrospectively corrected via image-domain interpolation (a.k.a., “gradwarp”) albeit with a loss of spatial resolution. For non-Cartesian MRI, the latter problem is exaggerated by noise and undersampling artifact. In this study, we describe a novel correction strategy that accounts for gradient nonlinearities during — rather than after — non-Cartesian MRI reconstruction, and demonstrate that this approach mitigates the resolution loss that can occur with standard methods. Methods: To test the proposed method, the American College of Radiology (ACR) quality control phantom was scanned on at 1.5 T (General Electric, v16.0, “zoom” gradient) using a 1.6x undersampled 3D non- Cartesian Shells trajectory (GRE, FOV=24 cm3, 120 shells, 16552 shots, 512 readout, matrix=2403). Image reconstruction was first performed via standard k-space density-compensated gridding and retrospectively corrected via cubic spline interpolation. Image reconstruction was then separately performed using a k-space and image-domain densitycompensated type-3 non-uniform fast Fourier transform (NUFFT), which provides a direct mapping between non-Cartesian k-space samples and warped image space voxel locations. Thus, no separate distortion correction procedure is needed for the proposed approach. The gradient distortion field was determined using vendor provided calibration data. Results: Phantom scan results show that both processing approaches successfully correct geometric distortion. However, visual inspection of the ACR phantom spatial resolution inserts shows that the proposed strategy preserves the resolution of the nominal (uncorrected) reconstruction while “gradwarp” imparts marked spatial blurring (especially for the 1.0 and 1.1 mm inserts) and thus resolution loss. Conclusion: We've presented a novel reconstruction strategy for non-Cartesian MRI that corrects for gradient nonlinearities during — rather than after — reconstruction, and thus better preserves image resolution than traditional interpolation-based methods. This approach is expected to be especially advantageous when imaging with non-standard magnet geometries. NIH RR018898; NIH EB10065.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling, sample extraction, and analytical methods to be used in the INL-2 study. For each of the five test events, the specified floor of the INL building will be contaminated with BG using a point-release device located in the room specified in the experimental design. Then quality control (QC), reference material coupon (RMC), judgmental, and probabilistic samples will be collected according to the sampling plan for each test event. Judgmental samples will be selected based on professional judgment and prior information. Probabilistic samples were selected with a random aspect and in sufficient numbers to provide desired confidence for detecting contamination or clearing uncontaminated (or decontaminated) areas. Following sample collection for a given test event, the INL building will be decontaminated. For possibly contaminated areas, the numbers of probabilistic samples were chosen to provide 95% confidence of detecting contaminated areas of specified sizes. For rooms that may be uncontaminated following a contamination event, or for whole floors after decontamination, the numbers of judgmental and probabilistic samples were chosen using the CJR approach. The numbers of samples were chosen to support making X%/Y% clearance statements with X = 95% or 99% and Y = 96% or 97%. The experimental and sampling design also provides for making X%/Y% clearance statements using only probabilistic samples. For each test event, the numbers of characterization and clearance samples were selected within limits based on operational considerations while still maintaining high confidence for detection and clearance aspects. The sampling design for all five test events contains 2085 samples, with 1142 after contamination and 943 after decontamination. These numbers include QC, RMC, judgmental, and probabilistic samples. The experimental and sampling design specified in this report provides a good statistical foundation for achieving the objectives of the INL-2 study.

59 BASIC BIOLOGICAL SCIENCES↗

Fluorescence imaging of viscous materials in the ultraviolet-visible wavelength range

This paper presents an approach of an innovative measurement principle for the quality control of viscous materials during a manufacturing process based on fluorescence imaging. The main contribution to the state of the art provided by this measurement system is that three equal fluorescence images of a static or moving viscous object are available in different optical paths. The independent images are obtained by two beam splitters which are connected in series. Based on these images, it is possible to evaluate each image separately. In our case, three optical bandpass filters with different center wavelengths of 405 nm, 420 nm, and 440 nm were used to filter the separate fluorescence images. The developed system is useable for the detection of impurities in the micrometer range. Further, incorrect mixing ratios of particular components and wrong single components in the viscous materials can be detected with the setup. Moreover, it is possible to realize static and dynamic measurements. In this case the maximum speed of the objects was 0.2 m/s for the dynamic measurements. Advantages of this measurement setup are the universality due to the use of optical standard components, the small dimension and the opportunity to integrate it easily into ongoing processes. In addition, the measurement system works on a non-contact basis. Thus, the expense for maintenance is at a very low level compared to currently available measurement setups for the investigated application. Furthermore, the setup provides for the first time a simultaneous analysis of more than one component and the detection of impurities concerning their nature and size in a manufacturing process.

36 MATERIALS SCIENCE↗

WE-FG-207B-10: Dual-Energy CT Monochromatic Image Consistency Across Vendors and Platforms

Purpose: Although dual-energy CT provides improved sensitivity of HU for certain tissue types at lower simulated energy levels, if these values vary by scanner type they may impact clinical patient management decisions. Each manufacturer has selected a specific dual-energy CT approach (or in one case, three different approaches); understanding HU variability among low monochromatic images may be required when more than one dual-energy CT scanner type is available for use. Methods: A large elliptical dualenergy quality control phantom (Gammex Inc.; Middleton, WI) containing several standard tissue type materials was scanned at least three times on each of the following systems: GE HD750, prototype GE Revolution CT with GSI, Siemens Flash, Siemens Edge, Siemens AS 128, and Philips IQon. Images were generated at 50, 70, and 140 keV. Soft tissue and Iodine HU were measured on a single central 5mm-thick image; NIST constants were used to calculate the ideal HU for each material. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were held as consistent as possible (thickness, kernel, no noise reduction). Results: Measured soft tissue (29 HU at 120 kVp) varied from 28 HU to 44 HU at 50 keV (excluding one outlier), from 21 HU to 31 HU at 70 keV, and from 19 HU to 32 HU at 140 keV. Measured iodine (5mg/ml, 106 HU at 120 kVp) varied from 246 HU to 280 HU at 50 keV, from 123 HU to 129 HU at 70 keV, and from 22 HU to 32 HU at 140 keV. Conclusion: Measured HU in standard rods across 3 dual-energy CT manufacturers and 6 scanner models varied directly with monochromatic level, with the most variability was observed at 50 keV and least variability at 70keV. Future work will include additional scanner platforms and how measurement variability impacts radiologists. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Ubiquitination of specific mitochondrial matrix proteins

Several protein quality control systems in bacteria and/or mitochondrial matrix from lower eukaryotes are absent in higher eukaryotes. These are transfer-messenger RNA (tmRNA), The N-end rule ATP-dependent protease ClpAP, and two more ATP-dependent proteases, HslUV and ClpXP (in yeast). The lost proteases resemble the 26S proteasome and the role of tmRNA and the N-end rule in eukaryotic cytosol is performed by the ubiquitin proteasome system (UPS). Therefore, we hypothesized that the UPS might have substituted these systems – at least partially – in the mitochondrial matrix of higher eukaryotes. Using three independent experimental approaches, we demonstrated the presence of ubiquitinated proteins in the matrix of isolated yeast mitochondria. First, we show that isolated mitochondria contain ubiquitin (Ub) conjugates, which remained intact after trypsin digestion. Second, we demonstrate that the mitochondrial soluble fraction contains Ub-conjugates, several of which were identified by mass spectrometry and are localized to the matrix. Third, using immunoaffinity enrichment by specific antibodies recognizing digested ubiquitinated peptides, we identified a group of Ub-modified matrix proteins. The modification was further substantiated by separation on SDS-PAGE and immunoblots. Last, we attempted to identify the ubiquitin ligase(s) involved, and identified Dma1p as a trypsin-resistant protein in our mitochondrial preparations. Taken together, these data suggest a yet undefined role for the UPS in regulation of the mitochondrial matrix proteins. -- Highlights: •Mitochondrial matrix contains ubiquitinated proteins. •Ubiquitination occurs most probably in the matrix. •Dma1p is a ubiquitin ligase present in mitochondrial preparations.

60 APPLIED LIFE SCIENCES↗

Test and extraction methods for the QC parameters of silicon strip sensors for ATLAS upgrade tracker

The Quality Control (QC) of pre-production strip sensors for the Inner Tracker (ITk) of the ATLAS Inner Detector upgrade has finished, and the collaboration has embarked on the QC test programme for production sensors. This programme will last more than 3 years and comprises the evaluation of approximately 22000 sensors. 8 Types of sensors, 2 barrel and 6 endcap, will be measured at many different collaborating institutes. The sustained throughput requirement of the combined QC processes is around 500 sensors per month in total. Measurement protocols have been established and acceptance criteria have been defined in accordance with the terms agreed with the supplier. For effective monitoring of test results, common data file formats have been agreed upon across the collaboration. To enable evaluation of test results produced by many different test setups at the various collaboration institutes, common algorithms have been developed to collate, evaluate, plot and upload measurement data. This allows for objective application of pass/fail criteria and compilation of corresponding yield data. These scripts have been used to process the data of more than 3000 sensors so far, and have been instrumental for identification of faulty sensors and monitoring of QC testing progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing an acoustic-property relationship in laser powder bed fusion with machine learning

Quality control of Laser Powder Bed Fusion (PBF-LB) additively manufactured parts is an important hurdle inhibiting the technology’s use structural applications. Acoustic monitoring of the laser powder bed fusion process can detect defects in-situ that are known to degrade mechanical properties. However, processing-structure-property (PSP) relationships are required to extrapolate from detected defects to part performance. Here, this study explores how acoustics may be a suitable signature linking processing conditions to properties, thus effectively substituting for structure in the PSP relationship. Establishing such a relationship would enable a part’s mechanical performance to be directly predicted from its acoustic signature, reducing the need for destructive testing or microstructural analysis to ensure a part will meet performance requirements. One hundred CoCrFeMnNi high entropy alloy tensile bars were printed across 13 process conditions in a series of 6 prints. The acoustic signatures of these tensile bars were used to train machine learning models to predict each part’s mechanical properties. By using both process information and acoustic information to predict mechanical properties, yield strength was predicted 18% more accurately and ductility to failure was predicted 10% more accurately than is achieved when using duplicate parts to predict part performance. Finally, individual acoustic frequencies were investigated to determine why acoustic signatures improve mechanical property predictions and the potential physical origins of these signatures. This work demonstrates how blending acoustics, process information, and machine learning can provide in-situ diagnostics of mechanical properties and improve the reliability of the PBF-LB process.

Acoustic emission↗

TU-B-19A-01: Image Registration II: TG132-Quality Assurance for Image Registration

AAPM Task Group 132 was charged with a review of the current approaches and solutions for image registration in radiotherapy and to provide recommendations for quality assurance and quality control of these clinical processes. As the results of image registration are always used as the input of another process for planning or delivery, it is important for the user to understand and document the uncertainty associate with the algorithm in general and the Result of a specific registration. The recommendations of this task group, which at the time of abstract submission are currently being reviewed by the AAPM, include the following components. The user should understand the basic image registration techniques and methods of visualizing image fusion. The disclosure of basic components of the image registration by commercial vendors is critical in this respect. The physicists should perform end-to-end tests of imaging, registration, and planning/treatment systems if image registration is performed on a stand-alone system. A comprehensive commissioning process should be performed and documented by the physicist prior to clinical use of the system. As documentation is important to the safe implementation of this process, a request and report system should be integrated into the clinical workflow. Finally, a patient specific QA practice should be established for efficient evaluation of image registration results. The implementation of these recommendations will be described and illustrated during this educational session. Learning Objectives: Highlight the importance of understanding the image registration techniques used in their clinic. Describe the end-to-end tests needed for stand-alone registration systems. Illustrate a comprehensive commissioning program using both phantom data and clinical images. Describe a request and report system to ensure communication and documentation. Demonstrate an clinically-efficient patient QA practice for efficient evaluation of image registration.

60 APPLIED LIFE SCIENCES↗

What's with all this peer-review stuff anyway?

The Journal of Physical Security was ostensibly started to deal with a perceived lack of peer-reviewed journals related to the field of physical security. In fact, concerns have been expressed that the field of physical security is scarcely a field at all. A typical, well-developed field might include the following: multiple peer-reviewed journals devoted to the subject, rigor and critical thinking, metrics, fundamental principles, models and theories, effective standards and guidelines, R and D conferences, professional societies, certifications, its own academic department (or at least numerous academic experts), widespread granting of degrees in the field from 4-year research universities, mechanisms for easily spotting 'snake oil' products and services, and the practice of professionals organizing to police themselves, provide quality control, and determine best practices. Physical Security seems to come up short in a number of these areas. Many of these attributes are difficult to quantify. This paper seeks to focus on one area that is quantifiable: the number of peer-reviewed journals dedicated to the field of Physical Security. In addition, I want to examine the number of overall periodicals (peer-reviewed and non-peer-reviewed) dedicated to physical security, as well as the number of papers published each year about physical security. These are potentially useful analyses because one can often infer how healthy or active a given field is by its publishing activity. For example, there are 2,754 periodicals dedicated to the (very healthy and active) field of physics. This paper concentrates on trade journal versus peer-reviewed journals. Trade journals typically focus on practice-related topics. A paper appropriate for a trade journal is usually based more on practical experience than rigorous studies or research. Models, theories, or rigorous experimental research results will usually not be included. A trade journal typically targets a specific market in an industry or trade. Such journals are often considered to be news magazines and may contain industry specific advertisements and/or job ads. A peer-reviewed journal, a.k.a 'referred journal', in contrast, contains peer-reviewed papers. A peer-reviewed paper is one that has been vetted by the peer review process. In this process, the paper is typically sent to independent experts for review and consideration. A peer-reviewed paper might cover experimental results, and/or a rigorous study, analyses, research efforts, theory, models, or one of many other scholarly endeavors.

99 GENERAL AND MISCELLANEOUS↗

WE-AB-204-05: Harmonizing PET/CT Quantification in Multicenter Studies: A Case Study

Purpose: To present the implementation of a strategy to harmonize FDG PET/CT quantification (SUV), performed with different scanner models and manufacturers. Methods: The strategy was based on Boellaard (2011) and EARL FDG-PET/CT accreditation program, that propose quality control measurements for harmonizing scanner performance. A NEMA IEC Body phantom study was performed using four different devices: PHP-1 (Gemini TF Base, Philips); PHP-2 (Gemini GXL, Philips); GEH (Discovery 600, General Electric); SMS (Biograph Hi-Rez 16, Siemens). The SUV Recovery Coefficient (RC) was calculated using the clinical protocol and other clinically relevant reconstruction parameters. The most appropriate reconstruction parameters (MARP) for SUV harmonization, in each scanner, are those which achieve EARL harmonizing standards. They were identified using the lowest root mean square errors (RMSE). To evaluate the strategy’s effectiveness, the Maximum Differences (MD) between the clinical and MARP RC values were calculated. Results: The reconstructions parameters that obtained the lowest RMSE are: FBP 5mm (PHP-1); LOR-RAMLA 2i0.008l (PHP-2); VuePointHD 2i32s10mm (GEH); and FORE+OSEM 4i8s6mm (SMS). Thus, to ensure that quantitative PET image measurements are interchangeable between these sites, images must be reconstructed with the above-mentioned parameters. Although, a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies was observed. The MD showed that the strategy was effective in reducing the variability of SUV quantification for small structures (<17mm). Conclusion: The harmonization strategy of the SUV quantification implemented with these devices was effective in reducing the variability of small structures quantification, minimizing the inter-scanner and inter-institution differences in quantification. However, it is essential that, in addition to the harmonization of quantification, the standardization of the methodology of patient preparation must be maintained, in order to minimize the SUV variability due to biological factors. Financial support by CAPES.

60 APPLIED LIFE SCIENCES↗

SU-G-206-07: Dual-Energy CT Inter- and Intra-Scanner Variability Within One Make and Model

Purpose: It can be logistically quite difficult to scan patients on the same exact device for their repeat visits in multi-scanner facilities. The reliability between dual-energy CT scanners’ quantitative results is not known, nor is their individual repeatability. Therefore, we evaluated inter- and intra-scanner variability with respect to several key clinical quantitative metrics specific to dual-energy CT. Methods: Eleven identical GE HD-750 CT scanners in a busy clinical environment were used to perform dual-energy (DE) CT scans of a large elliptical quality control (QC) phantom (Gammex, Inc.; Middleton, WI) which contains many standard insert materials. The DE-QC phantom was scanned bi-weekly during 2016; 3 to 4 scans were obtained from each scanner (a total of 35 data sets were used for analysis). Iodine accuracy for the 2mg/ml, 5mg/ml and 15mg/ml rods (from the Iodine(Water) image set) and soft tissue HU (40 HU based on NIST constants) from the 50keV data set were used to assess inter- and intra-scanner variability (standard deviation). Results: Intra-scanner variability average for 2mg/ml Iodine was 0.10 mg/ml (range 0.05–0.15 mg/ml), for 5mg/ml Iodine was 0.12 mg/ml (range 0.07–0.16 mg/ml), for 15 mg/ml Iodine was 0.25 mg/ml (range 0.16–0.37 mg/ml), and for the soft tissue inserts was 2.1 HU (range 1.8–2.6 HU). Inter-scanner variability average for 2mg/ml Iodine was 0.16 mg/ml (range 0.11–0.19 mg/ml), for 5mg/ml Iodine was 0.18 mg/ml (range 0.11–0.22 mg/ml), for 15 mg/ml Iodine was 0.35 mg/ml (range 0.23–0.44 mg/ml), and for the soft tissue inserts was 3.8 HU (range 3.1–4.5 HU). Conclusion: Intra-scanner variability for the iodine and soft tissue inserts averaged 3.1% and 5.2% respectively, and inter-scanner variability for these regions analyzed averaged 5.0% and 9.5%, respectively. Future work will include determination of smallest measurable change and acceptable limits for DE-CT scanner variability over longer time intervals. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Lung autophagic response following exposure of mice to whole body irradiation, with and without amifostine

Research highlights: {yields} We investigated the effect 6 Gy of WBI on the autophagic machinery of normal mouse lung. {yields} Irradiation induces dysfunction of the autophagic machinery in normal lung, characterized by decreased transcription of the LC3A/Beclin-1 mRNA and accumulation of the LC3A, and p62 proteins. {yields} The membrane bound LC3A-II protein levels increased in the cytosolic fraction (not in the pellet), contrasting the patterns noted after starvation-induced autophagy. {yields} Administration of amifostine, reversed all the LC3A and p62 findings, suggesting protection of the normal autophagic function. -- Abstract: Purpose: The effect of ionizing irradiation on the autophagic response of normal tissues is largely unexplored. Abnormal autophagic function may interfere the protein quality control leading to cell degeneration and dysfunction. This study investigates its effect on the autophagic machinery of normal mouse lung. Methods and materials: Mice were exposed to 6 Gy of whole body {gamma}-radiation and sacrificed at various time points. The expression of MAP1LC3A/LC3A/Atg8, beclin-1, p62/sequestosome-1 and of the Bnip3 proteins was analyzed. Results: Following irradiation, the LC3A-I and LC3A-II protein levels increased significantly at 72 h and 7 days. Strikingly, LC3A-II protein was increased (5.6-fold at 7 days; p < 0.001) only in the cytosolic fraction, but remained unchanged in the membrane fraction. The p62 protein, was significantly increased in both supernatant and pellet fraction (p < 0.001), suggesting an autophagosome turnover deregulation. These findings contrast the patterns of starvation-induced autophagy up-regulation. Beclin-1 levels remained unchanged. The Bnip3 protein was significantly increased at 8 h, but it sharply decreased at 72 h (p < 0.05). Administration of amifostine (200 mg/kg), 30 min before irradiation, reversed all the LC3A and p62 findings on blots, suggesting restoration of the normal autophagic function. The LC3A and Beclin1 mRNA levels significantly declined following irradiation (p < 0.01), whereas Bnip3 levels increased. Conclusions: It is suggested that irradiation induces dysfunction of the autophagic machinery in normal lung, characterized by decreased transcription of the LC3A/Beclin-1 mRNA and accumulation of the LC3A, and p62 proteins. Whether this is due to defective maturation or to aberrant degradation of the autophagosomes requires further investigation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

An Aerial Radiological Survey of Selected Areas of Area 18 - Nevada Test Site

As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of Area 18 of the Nevada Test Site (NTS) for the purpose of mapping man-made radiation deposited as a result of the Johnnie Boy and Little Feller I tests. The survey area centered over the Johnnie Boy ground zero but also included the ground zero and deposition area of the Little Feller I test, approximately 7,000 feet (2133 meters) southeast of the Johnnie Boy site. The survey was conducted in one flight. The completed survey covered a total of 4.0 square miles. The flight lines (with the turns) over the surveyed areas are presented in Figure 1. One 2.5-hour-long flight was performed at an altitude of 100 ft above ground level (AGL) with 200 foot flight-line spacing. A test-line flight was conducted near the Desert Rock Airstrip to ensure quality control of the data. The test line is not shown in Figure 1. However, Figure 1 does include the flight lines for a ''perimeter'' flight. The path traced by the helicopter flying over distinct roads within the survey area can be used to overlay the survey data on a base map or image. The flight survey lines were flown in an east-west orientation perpendicular to the deposition patterns for both sites. This technique provides better spatial resolution when contouring the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected every second over the course of the survey and were geo-referenced using a differential Global Positioning System. Spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also identify specific radioactive isotopes. Based on the results of the RSL NTS 1994 surveys, this area was chosen for a resurvey to improve the spatial resolution of the reported depositions for the Johnnie Boy and Little Feller I events. In addition, the survey was expected to confirm the absence of detectable concentrations of Americium-241 (Am-241) at the Johnnie Boy site and attempt to confirm the presence of Uranium-235 (U-235).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-129: A Strategy to Consolidate the Image Database of a VERO Unit Into a Radiotherapy Management System

Purpose: To present a strategy to integrate the imaging database of a VERO unit with a treatment management system (TMS) to improve clinical workflow and consolidate image data to facilitate clinical quality control and documentation. Methods: A VERO unit is equipped with both kV and MV imaging capabilities for IGRT treatments. It has its own imaging database behind a firewall. It has been a challenge to transfer images on this unit to a TMS in a radiation therapy clinic so that registered images can be reviewed remotely with an approval or rejection record. In this study, a software system, iPump-VERO, was developed to connect VERO and a TMS in our clinic. The patient database folder on the VERO unit was mapped to a read-only folder on a file server outside VERO firewall. The application runs on a regular computer with the read access to the patient database folder. It finds the latest registered images and fuses them in one of six predefined patterns before sends them via DICOM connection to the TMS. The residual image registration errors will be overlaid on the fused image to facilitate image review. Results: The fused images of either registered kV planar images or CBCT images are fully DICOM compatible. A sentinel module is built to sense new registered images with negligible computing resources from the VERO ExacTrac imaging computer. It takes a few seconds to fuse registered images and send them to the TMS. The whole process is automated without any human intervention. Conclusion: Transferring images in DICOM connection is the easiest way to consolidate images of various sources in your TMS. Technically the attending does not have to go to the VERO treatment console to review image registration prior delivery. It is a useful tool for a busy clinic with a VERO unit.

60 APPLIED LIFE SCIENCES↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Involvement of the Nrf2-proteasome pathway in the endoplasmic reticulum stress response in pancreatic β-cells

The ubiquitin-proteasome system plays a central role in protein quality control through endoplasmic reticulum (ER)-associated degradation (ERAD) of unfolded and misfolded proteins. NF-E2‐related factor 2 (Nrf2) is a transcription factor that controls the expression of an array of phase II detoxification and antioxidant genes. Nrf2 signaling has additionally been shown to upregulate the expression of the proteasome catalytic subunits in several cell types. Here, we investigated the role of Nrf2 in tunicamycin-induced ER stress using a murine insulinoma β-cell line, βTC-6. shRNA-mediated silencing of Nrf2 expression in βTC-6 cells significantly increased tunicamycin-induced cytotoxicity, elevated the expression of the pro-apoptotic ER stress marker Chop10, and inhibited tunicamycin-inducible expression of the proteasomal catalytic subunits Psmb5 and Psmb6. The effects of 3H-1,2-dithiole-3-thione (D3T), a small molecule Nrf2 activator, on ER stress were also examined in βTC-6 cells. D3T pretreatment reduced tunicamycin cytotoxicity and attenuated the tunicamycin-inducible Chop10 and protein kinase RNA-activated‐like ER kinase (Perk). The protective effect of D3T was shown to be associated with increased ERAD. D3T increased the expression of Psmb5 and Psmb6 and elevated chymotrypsin-like peptidase activity; proteasome inhibitor treatment blocked D3T effects on tunicamycin cytotoxicity and ER stress marker changes. Similarly, silencing of Nrf2 abolished the protective effect of D3T against ER stress. These results indicate that the Nrf2 pathway contributes to the ER stress response in pancreatic β-cells by enhancing proteasome-mediated ERAD. -- Highlights: ► Nrf2 silencing in pancreatic β-cells enhanced tunicamycin-mediated ER stress. ► Expression of the proteasome was inducible by Nrf2 signaling. ► Nrf2 activator D3T protected β-cells from tunicamycin-mediated ER stress. ► Protective effect of D3T was associated with Nrf2-dependent proteasome induction.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-08: Dual-Energy CT Iodine Accuracy Across Vendors and Platforms

Purpose: Although a major benefit of dual-energy CT is its quantitative capabilities, it is critical to understand how results vary by scanner manufacturer and/or model before making clinical patient management decisions. Each manufacturer utilizes a specific dual-energy CT approach; cross-calibration may be required for facilities with more than one dual-energy CT scanner type. Methods: A solid dual-energy quality control phantom (Gammex, Inc.; Appleton, WI) representing a large body cross-section containing three Iodine inserts (2mg/ml, 5mg/ml, 15 mg/ml) was scanned on these CT systems: GE HD-750 (80/140kVp), prototype GE Revolution CT with GSI (80/140kVp), Siemens Flash (80/140kVp and 100/140kVp), and Philips IQon (120kVp and 140kVp). Iodine content was measured in units of concentration (mg/ml) from a single 5mm-thick central image. Three to five acquisitions were performed on each scanner platform in order to compute standard deviation. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were as consistent as possible (thickness, kernel, no noise reduction applied). Results: Iodine measurement error ranges were −0.24-0.16 mg/ml for the 2mg/ml insert (−12.0 − 8.0%), −0.28–0.26 mg/ml for the 5mg/ml insert (−5.6 − 5.2%), and −1.16−0.99 mg/ml for the 15mg/ml insert (−7.7 − 6.6%). Standard deviations ranged from 0 to 0.19 mg/ml for the repeated acquisitions from each scanner. The average iodine measurement error and standard deviation across all systems and inserts was −0.21 ± 0.48 mg/ml (−1.5 ± 6.48%). The largest absolute measurement error was found in the 15mg/ml iodine insert. Conclusion: There was generally good agreement in Iodine quantification across 3 dual-energy CT manufacturers and 4 scanner models. This was unexpected given the widely different underlying dual-energy CT mechanisms employed. Future work will include additional scanner platforms, independent verification of the Iodine insert standard concentrations (especially the 15 mg/ml insert), and how much measurement variability can be clinically tolerated. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

SU-E-T-160: Characterization and Monitoring of Linear Accelerator Gantry Radiation Isocenter Motion

Purpose: To characterize the motion of the radiation isocenter, over time, as a function of gantry rotation for multiple linear accelerators (linacs). Two semi-automated image-based quality control (QC) test workflows were designed to achieve this goal. Methods: The full QC-test workflow for motion characterization consisted of acquiring 16 megavoltage images at 8 gantry angles of a ball-bearing suspended off the end of the couch. Performance constancy was assessed using a shortened QC-test workflow which consisted of imaging a cube phantom placed on the couch (5 images at 4 gantry angles). Both workflows use an image processing algorithm to determine the field center and phantom position on each image and computed radiation isocenter motion as a function of gantry angle. Motion was characterized for 9 linacs of same model and performance monitored for 2 months on 3 linacs. Results: The maximum isocenter motion determined with the full-workflow for 9 linacs was within 0.38–0.79 mm. The shortened-workflow usually agreed within 0.1 mm with the full-workflow and the time required for these methods was about 4 and 15 min, respectively. For all linacs, the isocenter motion perpendicular to the gantry rotation plane followed a consistent pattern with maximum amplitude of 0.36–0.59 mm. In the gantry rotation plane, the variation among linacs was higher and the beam axis described a circle of up to 0.6 mm radius around the gantry axis of rotation (2 linacs). The radiation isocenter motion was stable as a function of time for the monitored linacs and was within ±0.1 mm of the average. Conclusion: Radiation isocenter motion parallel and perpendicular to the gantry rotation plane was characterized. In the gantry rotation plane, beam spot positioning adjustment might be used to reduce the observed radiation isocenter motion. A shortened-workflow was designed and enables performance monitoring over time.

60 APPLIED LIFE SCIENCES↗