Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 3”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Symmetric Mass Generation

In recent years tantalizing signs for a novel phase have been reported that is chirally symmetric but nevertheless exhibits massive bound states. The necessary condition for such a phase, referred to as Symmetric Mass Generation (SMG), is the cancellation of all (continuous and discrete) 't~Hooft anomalies. In 3+1 dimensions this occurs in systems containing a multiple of 16 massless Weyl fermions. SMG was originally discovered in lower dimensional condensed matter systems. We present results investigating four dimensional field theories with gauge group SU(3). Our findings suggest that SU(3) with $N_f=8$ fundamental fermions exhibits an SMG phase not only on the lattice but also in the infinite cutoff continuum limit. If confirmed, SMG could provide a new UV completion of the standard model and give rise to new scenarios for beyond standard model physics.

Hasenfratz, Anna [U. Colorado, Boulder] (ORCID:000↗

INCREASING THE TRANSPARENCY AND REPRODUCIBILITY OF SPACE RADIATION SCIENCE: THE RADIATION BIOLOGY ONTOLOGY

Among the primary objectives of the Open/Open-Source Science paradigm are making scientific investigation data transparent and results reproducible [1], objectives shared by the FAIR principles [2]. To accomplish this, the conceptual framework that includes all the investigation objects needs to be accurately captured and communicated to all data consumers. A large part of this requires using metadata standards to annotate data collected. These standards should be readily accessible, informed by scientific community consensus and sufficiently specific to encompass all of the important aspects of the investigation. Starting in 2020 we have been co-leading an open consortium to develop a new metadata standard, the Radiation Biology Ontology (RBO), through the Open Biological and Biomedical Ontologies (OBO) Foundry [3]. We began by transforming many of the terms from the National Council on Radiation Protection and Measurement into concepts that can be formally related to existing OBO Foundry classes or attributes. We then identified and imported into the RBO existing OBO Foundry classes that have obvious relevance for radiation biomedicine (for example, concepts from the Environment Ontology that describe radiative processes, and concepts from the Gene Ontology dealing with molecular and cellular responses to radiation). Finally, we scrutinized datasets from investigations of radiation effects held in NASA GeneLab and LSDA repositories and added additional classes, instances, and attributes into the RBO that should be used to annotate these data. We developed the RBO using the open-source tools of GitHub and publish the RBO periodically through the NIH/NCBI BioPortal website, so systems worldwide can leverage the knowledge it contains [4]. This initial phase of concept modeling has yielded an RBO that at present has more than 300 declared concepts, with more than 3500 additional concepts imported from other OBO Foundry ontologies. While this first phase has focused on concepts for annotating samples, environments, exposures, and measurements, the next phase will center on supporting annotation of results and findings, such as concept models of molecular, cellular and tissue effects. The value of the RBO will be determined in part by our ability to engage the community in its development, and we have established a Radiobiology Informatics Consortium with unrestricted membership as the owner of the RBO in order to encourage investigators, system owners and other to join in this effort. Anyone can report issues or request new concept modeling or other features directly on GitHub. By using the BioPortal application programming interface, systems can pose dynamic queries to the latest version of the RBO for information on individual classes or entire hierarchies; this design eliminates the need for systems to be updated in order to use newer versions of the RBO. We hope to contribute to the advancement of open radiobiological science through the continued, open development of the RBO, that will provide more precise, machine-interpretable descriptions of investigations, as well as support data meta-analysis through machine learning or other artificial intelligence methods. REFERENCES [1] Open science in space. Nature Medicine, 2021. 27(9): p. 1485-1485. [2] Wilkinson, M.D., et al., The FAIR Guiding Principles for scientific data management and stewardship. Sci Data, 2016. 3: p. 160018. [3] Smith, B., et al., The OBO Foundry: coordinated evolution of ontologies to support biomedical data integration. Nat Biotechnol, 2007. 25(11): p. 1251-5. [4] Whetzel, P.L., et al., BioPortal: enhanced functionality via new Web services from the National Center for Biomedical Ontology to access and use ontologies in software applications. Nucleic Acids Res, 2011. 39(Web Server issue): p. W541-5.

informatics↗

Effect of Ce{sup 3+} Ion on Structural and Hyperfine Interaction Studies of Co{sub 0.5}Ni{sub 0.5}Fe{sub 2−x}Ce{sub x}O{sub 4} Ferrites: Useful for Permanent Magnet Applications

Nanoparticles of Co{sub 0.5}Ni{sub 0.5}Fe{sub 2−x}Ce{sub x}O{sub 4} (where x = 0.0, 0.01, 0.015 and 0.02) ferrites are prepared by the modified solution combustion method using a mixture of fuels and are characterized to understand their structural, microstructural and magnetic properties. The X-ray diffraction is used to confirm the formation of a single-phase cubic spinel structure. The average crystallite sizes are calculated using the Scherrer formula and are found to be less than 50 nm. The microstructural features are obtained by the scanning electron microscopy, and the compositional analysis is done by using the energy-dispersive spectroscopy. The transmission electron microscopy (TEM) investigations show that the synthesized ferrites are made up of very fine spherical nanoparticles. The influence of a rare-earth element (Ce{sup 3+}) on the magnetic properties of the samples was studied using the Mössbauer spectroscopy. The Mössbauer spectroscopy reveals the formation of broadened Zeeman lines and quadrupole-split lines and the presence of the Fe{sup 3+} charge state at B sites in the samples. The quadrupole splitting shows that the orientation of the magnetic hyperfine field with respect to the principle axes of the electric field gradient was random. The magnetic hyperfine field values indicate that the A sites have more A-O-B superexchange interactions than the B sites. The coexistence of magnetic sextet and a doublet component on the room-temperature spectra suggests superparamagnetic properties of the nanoparticles. The low-temperature (15 K) Mössbauer spectroscopy explores the paramagnetic relaxation in the nanoparticles. The area under the sextet refers to Fe{sup 3+} concentrations in the tetrahedral and octahedral sites of the ferrite. This study confirms that the Ce{sup 3+} substitution of Fe{sup 3+} only for octahedron sites causes the decrease in Fe-O-Fe arrangement. The effect of Ce{sup 3+} doping on the magnetic properties of Co{sub 0.5}Ni{sub 0.5}Fe{sub 2}O{sub 4} is examined from the vibrating sample magnetometry (VSM) spectra. Saturation magnetization values are decreased initially and then increased, as result of Ce{sup 3+} doping. This can be explained by Neel’s two-sub-lattice model. Further, the value of coercivity is found to be increasing with increasing Ce{sup 3+} concentration. The obtained results of M-H loop with improved coercivity (from 851 to 1039 Oe) by Ce{sup 3+} doping of Co{sub 0.5}Ni{sub 0.5}Fe{sub 2}O{sub 4} demonstrate the usefulness for permanent magnet applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling the non-Schmid crystallographic slip in MAX phases

We present a crystal plasticity constitutive relation for the description of experimentally observed non-Schmid crystallographic slip in a class of ternary carbides and nitrides commonly referred to as MAX phases. In the constitutive relation, we assume that the evolution of the slip system strength in MAX phases has two components – a classical component that depends on the Taylor cumulative shear strain and a non-Schmid component that depends on the stress normal to the slip plane. The non-Schmid crystal plasticity constitutive relation is then used to carry out finite element simulations of micropillar compression of single crystals of two MAX phases, Ti 2 AlC and Ti 3 AlC 2 . The finite element simulations not only quantitatively predict the stress – strain response of a wide range of crystallographic orientations of the micropillars but also rationalize the non-uniform deformation and the deformed shape of the micropillars observed in the experiments for the two materials. As a result, parametric studies are also carried out to quantify the role of the non-Schmid effect and understand the effects of key experimental parameters on the stress – strain response of the micropillars of the two MAX phases.

36 MATERIALS SCIENCE↗

Influence of alveolar mixing and multiple breaths of aerosol intake on particle deposition in the human lungs

Predictive dosimetry models play an important role in assessing health effect of inhaled particulate matter and in optimizing delivery of inhaled pharmaceutical aerosols. Here, in this study, the commonly used 1D Multiple-Path Particle Dosimetry model (MPPD) was improved by including a mechanistically based model component for alveolar mixing of particles and by extending the model capabilities to account for multiple breaths of aerosol intake. These modifications increased the retained fraction of particles and consequently particle deposition predictions in the deep lung during tidal breathing. Comparison with an existing dataset (J. Aerosol Sci., 99:27-39, 2016) obtained under two breathing conditions referred to as slow and fast breathing showed significant differences in 1 µm particle deposition between predictions (slow: 30±1%, fast: 21±1%) and measurements (slow: 43±9%, fast: 30±5%) when the prior version of MPPD (single breath and no mixing, J. Aerosol Sci., 151:105647, 2021) was used. Adding a mixing model and multiple breaths moved the predictions (slow: 34±2%, fast:25±2%) closer to the range of deposition measurements. For 2.9 µm particles, predictions from both the original (slow: 70±2%, fast: 57±2%) and the revised MPPD model (slow: 71±2%, fast: 59±3%) compared well with experiments (slow: 67±8%, fast: 58±10%). This was expected as suspended fraction of 2.9 µm particles was small and thus the addition of alveolar mixing and multi breath capability only slightly increased the retained fraction for particles of this size and greater. The revised 1D model improves dose predictions in the deep lung and support human risk assessment from exposure to airborne particles.

60 APPLIED LIFE SCIENCES↗

Utah FORGE: GES Well 16A(78)-32 and Well 16B(78)-32 Stimulation Seismic Event Catalogs

This dataset contains seismic event catalogs from the hydraulic stimulation of wells 16A(78)-32 and 16B(78)-32 at the Utah FORGE site in April 2024. The data was collected by Geo Energy Suisse (GES) using a variety of seismic monitoring technologies, including 3-component (3C) geophones and distributed acoustic sensing (DAS) systems. These technologies were deployed across several locations, including wells 16A, 16B, and Delano-1, with sensor arrays at multiple depths to capture microseismic activity during the stimulations. The catalogs provide both real-time and manually checked seismic event locations, with detailed parameters such as trigger conditions, velocity models, and data acquisition settings. The dataset includes information on the stimulation stages, event rates, and hydraulic injection conditions for each well, with a report detailing the data acquisition configuration and seismic event location methodologies. Users will need to reference the included report for a complete understanding of the sensor network, data processing techniques, and accuracy considerations.

15 GEOTHERMAL ENERGY↗

Projection Microstereolithography for Architected Materials

Stereolithography (SL) is a prominent paradigm in the realm of additive manufacturing (AM) technologies, which refers to fabrication approaches that build “bottom up” by adding material. Pioneered in 1984 by Chuck Hull, SL relies on light-activated solidification of a liquid photosensitive resin in a layer-by-layer fashion, with the geometry of each layer defined by sectioning a three-dimensional (3D) computer model by closely-spaced parallel planes. The maturation of the technology over nearly three subsequent decades has resulted in the wide availability of commercial SL products, such as the ProJet series from 3D Systems, Inc. (which uses the proprietary acronym SLA to refer to SL technology), which routinely produces parts with 50-100 µm resolution in all three axes, and overall dimensions of 0.25-0.5 m. In the most general terms, advancements in SL technology have generally been aimed at achieving four goals: decreasing (1) system cost and (2) minimum feature size (i.e. improving resolution), while (3) increasing overall part size and (4) build speed. SL systems can be broadly categorized into two classes, by the way in which they deliver illumination to produce the shape of each object layer to be fabricated: laser-scanning and mask projection approaches. Commercially-available SL systems incorporate the laser-scanning approach, following the original scheme described by Hull, since digital image projection technology has only emerged relatively recently as a viable alternative. A significant limitation of laser scanning is the relatively slow speed of rastering the laser to form each layer’s pattern, highlighting the need for a dynamic mask-based approach to polymerize larger areas in a single exposure. The recent proliferation of digital display technologies (referred to as spatial light modulators or SLMs) has enabled the implementation of such “dynamic masking,” increasing system throughput by allowing a complete image layer to be cross-linked simultaneously. These mask projection SL systems are gaining greater prominence, and the landscape of some of the parameters available for system design, as implemented in recent work by a variety of investigators, has been reviewed by Lambert et al.

36 MATERIALS SCIENCE↗

Deep Borehole Field Test Specifications

This report documents conceptual design development for the Deep Borehole Field Test (DBFT), mainly the test packages (not containing waste) and the system for demonstrating emplacement and retrieval of those packages in the Field Test Borehole (FTB). For the DBFT to have demonstration value, it must be based on conceptualization of a deep borehole disposal (DBD) system for specific waste forms. This document therefore describes a current reference DBD concept, and analyzes key design options for disposal, to guide selection of options for the DBFT. The most important of these options is the emplacement mode, i.e. whether packages are emplaced using a wireline or a string of drill pipe (with a drill rig). This choice is analyzed using cost and risk models, in Sections 5 and 6. Other emplacement mode options are also identified and discussed. The reference DBD concept and the analysis of waste packaging and emplacement options, are used to develop requirements and assumptions for the DBFT and to recommend DBFT specifications. Design issues are identified, and priorities are developed for further conceptual design development and additional engineering analysis, anticipating future design activities. Conceptual design development is part of a process that proceeds in three stages: 1) conceptual design including feasibility studies; 2) preliminary design that includes technical and cost information necessary for final design; and 3) final design sufficient for fabrication or construction. The DBFT engineering demonstration will follow such an evolution. Whereas design evolution typically begins with bench-scale and pilot-scale investigations proceeding to conceptual, preliminary, and final designs, the DBFT can proceed directly to design because of extensive previous work and published literature on scientific drilling, characterization methods, waste packaging and handling, industrial deep-hole drilling and construction, and downhole operations. Hence it is anticipated that this report will lead to completion of conceptual design, then preliminary and final design, fabrication and testing, and demonstration of waste emplacement in a deep borehole.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bottom Fixed Platform Dynamics Models Assessing Surface Ice Interactions for Transitional Depth Structures in the Great Lakes: FAST8 – IceDyn

To create long-term solutions for offshore wind turbines in a variety of environmental conditions, CAE tools are needed to model the design-driving loads that interact with an offshore wind turbine system during operation. This report describes our efforts in augmenting existing CAE tools used for offshore wind turbine analysis with a new module that can provide simulation capabilities for ice loading on the system. This augmentation was accomplished by creating an ice-loading module coupled to FAST8, the CAE tool maintained by the NREL for simulating land-based and offshore wind turbine dynamics. The new module includes both static and dynamic ice loading that can be applied during a dynamic simulation of the response of an offshore wind turbine. The ice forces can be prescribed, or influenced by the structure’s compliant response, or by the dynamics of both the structure and the ice floe. The new module covers ice failure modes of spalling, buckling, crushing, splitting, and bending. The supporting structure of wind turbines can be modeled as a vertical or sloping form at the waterline. The Inward Battered Guide Structure (IBGS) foundation designed by Keystone Engineering for the Great Lakes was used to study the ice models coupled to FAST8. The IBGS foundation ice loading simulations in FAST8 were compared to the baseline simulation case without ice loading. The ice conditions reflecting those from Lake Huron at Port Huron and Lake Michigan at North Manitou were studied under near rated wind speed of 12 m/s for the NREL 5-MW reference turbine. Simulations were performed on ice loading models 1 through 4 and ice model 6 with their respective sub-models. The purpose of ice model 5 is to investigate ice loading on sloping structures such as ice-cones on a monopile and is not suitable for multi-membered jacketed structures like the IBGS foundation. The key response parameters from the simulations, shear forces and moments from the tower base and IBGS foundation base, were compared. Ice models 1 and 6 do not significantly affect the tower fore-aft shear and moment. However, ice model 2 (dynamic analyses), model 3 (random ice loading), and model 4 (multiple ice failure zone loading) show increased effect on the tower fore-aft shear and moment with significant effect from ice model 3.1. In general ice loading creates large reaction forces and moments at the base of the IBGS foundation; the largest occurred in model 1.1 (steady creep ice indentation loading) followed by model 3.1 (random creep ice indentation loading). In general the power production from the ice loading cases had little deviation from the baseline case without ice loading. For ultimate limit state (ULS), ice model 1.1 ice and 3.1 appear to be the ice most critical models to consider at an early stage of design. Ice model 4 is an important tool for assessing structural fatigue.

17 WIND ENERGY↗

Center for Integrated Simulation of Fusion Relevant RF Actuators

This project was part of the “Center for Integrated Simulation of Fusion Relevant RF Actuators” SciDAC-4 project, led by Dr. Paul Bonoli (MIT). Rather than use an acronym (CISFRRFA), the project will be referred to in this document as the “RF-SciDAC4”. The larger SciDAC-4 project goals were to: 1. Develop an integrated simulation of the antenna + sheath + scrape-off-layer + core plasma system which fully utilizes leadership class computing resources to move towards a quantitative predictive capability for the response to RF power. 2. Work closely with the SciDAC-4 Whole Device Modeling (WDM) community to make both our new code development efforts, as well as the established hierarchy of RF tools, available within their environment, and to utilize WDM technologies to implement the couplings below. 3. Validate this predictive capability on appropriately diagnosed experiments including dedicated RF test stands, linear devices, and existing tokamaks. 4. Use these tools to inform design of robust, impurity-mitigating RF heating and current drive sources for future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Global and Regional Temperature-change Potentials for Near-term Climate Forcers

The emissions of reactive gases and aerosols can affect climate through the burdens of ozone, methane and aerosols, having both cooling and warming effects. These species are generally referred to near-term climate forcers (NTCFs) or short-lived climate pollutants (SLCPs), because of their short atmospheric residence time. The mitigation of these would be attractive for both air quality and climate on a 30-year timescale, provided it is not at the expense of CO2 mitigation. In this study we examine the climate effects of the emissions of NTCFs from 4 continental regions (East Asia, Europe, North America and South Asia) using results from the Task Force on Hemispheric Transport of Air Pollution Source-Receptor global chemical transport model simulations. We address 3 aerosol species (sulphate, particulate organic matter and black carbon - BC) and 4 ozone precursors (methane, reactive nitrogen oxides - NOx, volatile organic compounds VOC, and carbon monoxide - CO). For the aerosols the global warming potentials (GWPs) and global temperature change potentials (GTPs) are simply time-dependent scaling of the equilibrium radiative forcing, with the GTPs decreasing more rapidly with time than the GWPs. While the aerosol climate metrics have only a modest dependence on emission region, emissions of NOx and VOCs from South Asia have GWPs and GTPs of higher magnitude than from the other northern hemisphere regions. On regional basis, the northern mid-latitude temperature response to northern mid-latitude emissions is approximately twice as large as the global average response for aerosol emission, and about 20-30% larger than the global average for methane, VOC and CO emissions. We also found that temperatures in the Arctic latitudes appear to be particularly sensitive to black carbon emissions from South Asia.

climate forcer↗

Universal correlation between CP phase $\delta$ and the non-unitarity $\alpha$ parameter phases

The non-unitarity of the neutrino mixing matrix is a problem related with a more fundamental question about the origin of the neutrino mass. After a brief discussion on the questions ``why do we need model-independent framework for unitarity test?'', we show interesting properties present in the oscillation probabilities of neutrinos propagating in matter with non-unitarity. That is, (1) partial unitarity and (2) universal phase correlation. %To illuminate these points, we formulate a perturbative framework with the two expansion parameters $\epsilon \equiv \Delta m^2_{21} / \Delta m^2_{31}$ and $\alpha$ matrix elements. The complex triangular $\alpha$ matrix is introduced through the definition of $3 \times 3$ non-unitary flavor mixing matrix $N$ as %\begin{eqnarray} N &=& \left( \bf{1} - \alpha \right) U = \left\{ \bf{1} - \left[ \begin{array}{ccc}\alpha_{ee} & 0 & 0 \\\alpha_{\mu e} & \alpha_{\mu \mu} & 0 \\\alpha_{\tau e} & \alpha_{\tau \mu} & \alpha_{\tau \tau} \\\end{array}\right] \right\}U \label{alpha-matrix-def}\end{eqnarray}%where $U$ is the unitary MNS mixing matrix, and hence $\alpha$ characterizes the size and the flavor dependence of unitarity violation (UV)\footnote{%%%%%%%%%%%%%Despite that in the physics literature UV usually means ``ultraviolet'', we use UV in this manuscript as an abbreviation for ``unitarity violation'' or ``unitarity violating''.}~~caused by new physics (NP) at low- or high-scales.~~~~The point (1) above essentially means that despite non-unitary mixing, neutrino evolution must be unitary because the three active neutrinos span a complete state space of neutral leptons. The {\em phase correlation} mentioned in the point (2) refers an intriguing property that the complex $\alpha$ parameters and $\nu$Standard Model CP phase $\delta$ always come into the oscillation probabilities in a correlated way, $e^{- i \delta } \alpha_{\mu e}$, $\alpha_{\tau e}$, and $e^{i \delta} \alpha_{\tau \mu}$, universally in all the oscillation channels. The physical meaning of this result is briefly discussed. }

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of ICRF Heating for SPARC during First Campaign and Primary Reference-Like Discharge using the Stix Code

High magnetic field tokamaks, like SPARC, rely on ion cyclotron radio frequency heating (ICRF) to reach fusion relevant temperatures. The SPARC tokamak will have 14 ICRF antennas in 7 toroidal locations delivering > 20 MW of power to the plasma. New capabilities with the full wave cold plasma solver, Stix, now allow for resolving the wave-particle resonances using lower order thermal corrections to capture core absorption of Landau damping and ion resonances in devices like SPARC. Favorable comparisons to the TORIC codes give confidence in the single pass absorption of this model to accurately capture the strength of edge interactions of the RF. Using this new dielectric formulation in the Stix code, simulations of the 2D poloidal cross section of SPARC are completed for the first campaign and primary reference-like discharges (PRD-like). A scan of the minority ion concentrations of helium-3 is performed and shows the expected behavior that as the helium-3 decreases the amount of single pass absorption also decreases which is seen in both scenarios. Additionally, both scenarios show only slight differences in single-pass absorption for the range of 3% to 5% helium-3 allowing for more flexibility in experiments. This study also highlights the differences between the first campaign and PRD-like with the first campaign discharges showing much more multi-pass absorption and an effect of confining the wave to a smaller portion of the cross-section due to the fast wave cut-off. This latter result suggests that far-field sheath rectification at the high-field side would be minimal for the first campaign scenario.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 09: Impact of the distance of reflective markers from linac isocenter on the positional accuracy of an infrared tracking system

Purpose: The HexaPOD™ six degree of freedom couchtop is equipped with an optical tracking system, consisting of a stereoscopic camera and a reference frame (RF) carrying infrared reflective markers. The manufacturer recommends placing the RF within 50 cm from linac isocenter (ISO), which is a serious limitation since the RF does not fit around the shoulders of most brain patients. This study quantifies the impact of extended RF distances from ISO on positional accuracy. Methods: An in-house tool with an estimated resolution of 0.3 mm and 0.1° was used. It is a large cube and a mathematical model of HexaPOD motion to determine the intersection of room lasers with the ruled cube edges. Combinations of translations (±1 and ±3 cm) and rotations (±2.5°) were executed on two HexaPOD couchtops for multiple RF distances from ISO (35 to 77 cm). For each combination, ten laser readings were fed into a least squares algorithm to determine the executed translations and rotations while minimizing operator reading errors. Results: The usable tracking volume is up to an RF distance of 82 cm from ISO. Positional accuracy of the HexaPOD/iGuide system is 0.6 mm and 0.1° (95% confidence). Positional accuracy variations versus RF distance from ISO are statistically insignificant (p = 0.05). Our results generally confirm recent internal estimates by the manufacturer (for future release). Conclusions: RF distances up to 77 cm from ISO are clinically acceptable, provided performing a patient safety study with a verification scan.

60 APPLIED LIFE SCIENCES↗

Human-System Interface Design Review Guidelines

The U.S. Nuclear Regulatory Commission (NRC) staff reviews the human factors engineering (HFE) aspects of nuclear power plants in accordance with the Standard Review Plan (NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition). The Human Factors Engineering Program Review Model (NUREG-0711, Revision 3, issued November 2012) contains detailed design review procedures. As part of the review process, the interfaces between plant personnel and the plant's systems and components are evaluated for conformance with HFE guidelines. This document, Human-System Interface Design Review Guidelines (NUREG-0700, Revision 3), provides the guidelines necessary to perform this evaluation. The review guidelines address the physical and functional characteristics of human-system interfaces (HSIs). Because these guidelines only address the HFE aspects of design and not other related considerations, such as instrumentation and control and structural design, they are referred to as HFE guidelines. In addition to the review of actual HSIs, the NRC staff can use the NUREG-0700 guidelines to evaluate a design-specific HFE guidelines document or style guide. The HFE guidelines are organized into four basic parts, which are divided into sections. Part I contains guidelines for the basic HSI elements: information displays, user-interface interaction and management, and analog displays and controls. These elements are used as building blocks to develop HSI systems to serve specific functions. Part II contains the guidelines for reviewing the following HSI systems: alarm system, safety parameter display system, group-view display system, soft control system, computer-based procedure system, automation system, and communication system. Part III provides guidelines for the review of workstations and workplaces. Part IV provides guidelines for the review of HSI support (i.e., maintainability of digital systems and degraded HSI and instrumentation and control conditions).

42 ENGINEERING↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Proposal to Simultaneously Profile Wind and CO2 on Earth and Mars With 2-micron Pulsed Lidar Technologies

2-micron lidar technology has been in use and under continued improvement for many years toward wind measurements. But the 2-micron wavelength region is also rich in absorption lines of CO2 (and H2O to a lesser extent) that can be exploited with the differential absorption lidar (DIAL) technique to make species concentration measurements. A coherent detection receiver offers the possibility of making combined wind and DIAL measurements with wind derived from frequency shift of the backscatter spectrum and species concentration derived from power of the backscatter spectrum. A combined wind and CO2 measurement capability is of interest for applications on both Earth and Mars. CO2 measurements in the Earth atmosphere are of importance to studies of the global carbon cycle. Data on vertically-resolved CO2 profiles over large geographical observations areas are of particular interest that could potentially be made by deploying a lidar on an aircraft or satellite. By combining CO2 concentration with wind measurements an even more useful data product could be obtained in the calculation of CO2 flux. A challenge to lidar in this application is that CO2 concentration measurements must be made with a high level of precision and accuracy to better than 1%. The Martian atmosphere also presents wind and CO2 measurement problems that could be met with a combined DIAL/Doppler lidar. CO2 concentration in this scenario would be used to calculate atmospheric density since the Martian atmosphere is composed of 95% CO2. The lack of measurements of Mars atmospheric density in the 30-60 km range, dust storm formation and movements, and horizontal wind patterns in the 0-20 km range pose significant risks to aerocapture, and entry, descent, and landing of future robotic and human Mars missions. Systematic measurement of the Mars atmospheric density and winds will be required over several Mars years, supplemented with day-of-entry operational measurements. To date, there have been 5 successful robotic landings on Mars. Atmospheric density and wind reconstruction has been performed for 3 of these entries (the two Viking landers and Mars Pathfinder). At present, all Mars atmospheric density and wind models have these 3 entries (at widely scattered positions and seasons) as their basis, supplemented by coarse orbital measurements of atmospheric opacity and temperature. This lack of data leads to a large uncertainty in prediction of the Mars atmospheric density and winds in the altitude regime where deceleration of landers will occur. This uncertainty will have a dramatically large impact on mass, cost and risk. The precision and accuracy for application to Mars is not as stringent as Earth, but Mars does pose a challenge in needing a high level of wavelength stability and control in order to reference wavelength to the narrow linewidths found in the low atmospheric pressure of Mars, as illustrated in Figure 1.

Singh, Upendra N.↗

A Fast Infrared Radiative Transfer Model for Overlapping Clouds

A fast infrared radiative transfer model (FIRTM2) appropriate for application to both single-layered and overlapping cloud situations is developed for simulating the outgoing infrared spectral radiance at the top of the atmosphere (TOA). In FIRTM2 a pre-computed library of cloud reflectance and transmittance values is employed to account for one or two cloud layers, whereas the background atmospheric optical thickness due to gaseous absorption can be computed from a clear-sky radiative transfer model. FIRTM2 is applicable to three atmospheric conditions: 1) clear-sky, 2) single-layered ice or water cloud, and 3) two simultaneous cloud layers in a column (e.g., ice cloud overlying water cloud). Moreover, FIRTM2 outputs the derivatives (i.e., Jacobians) of the TOA brightness temperature with respect to cloud optical thickness and effective particle size. Sensitivity analyses have been carried out to assess the performance of FIRTM2 for two spectral regions, namely the longwave (LW) band (587.3 - 1179.5/cm) and the short-to-medium wave (SMW) band (1180.1 - 2228.9/cm). The assessment is carried out in terms of brightness temperature differences (BTD) between FIRTM2 and the well-known discrete ordinates radiative transfer model (DISORT), henceforth referred to as BTD (F-D). The BTD (F-D) values for single-layered clouds are generally less than 0.8 K. For the case of two cloud layers (specifically ice cloud over water cloud), the BTD(F-D) values are also generally less than 0.8 K except for the SMW band for the case of a very high altitude (>15 km) cloud comprised of small ice particles. Note that for clear-sky atmospheres, FIRTM2 reduces to the clear-sky radiative transfer model that is incorporated into FIRTM2, and the errors in this case are essentially those of the clear-sky radiative transfer model.

Niu, Jianguo↗