Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rejection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

The continuous measurement of hydrogen chloride in the ambient atmosphere using the dual isotope infrared absorption technique

The results of a program to develop a prototype gas filter correlation NDIR analyzer capable of providing the required HCl measurement capability, while maintaining an adequate rejection of any other gases anticipated in the atmosphere are presented. Examples of the performance of the prototype analyzer are presented which show an rms noise equivalent concentration of 0.06 ppm of HCl was achieved while maintaining an electronically determined 10% to 90% time response to gas samples of about 2 seconds. No measureable response was observed to CO2, CO, and H2O while maintaining an adequate rejection of the hydrocarbons, for example CH4 and n-hexane. The experiments were performed which demonstrate that the span stability of the HCl gas filter correlation analyzer is unaffected by the presence of water vapor and which support the belief that the incorporation of a relatively open-volume, multiple path sample cell into the instrument would enable ground station as well as airborne measurements of trace quantities of HCl in the ambient atmosphere to be performed.

Williams, K. G.↗

Shuttle active thermal control system development testing. Volume 2: Modular radiator system tests

Tests were designed to investigate the validity of the "modular" approach to space radiator system design for space shuttle and future applications by gathering performance data on various systems comprised of different numbers of identical panels, subject to nominal and extreme heat loads and environments. Both one-sided and two-sided radiation was tested, and engineering data was gathered on simulated low a/e coatings and system response to changes in outlet temperature control point. The results of the testing showed system stability throughout nominal orbital transients, unrealistically skewed environments, freeze-thaw transients, and rapid changes in outlet temperature control point. Various alternative panel plumbing arrangements were tested with no significant changes in performance being observed. With the MRS panels arranged to represent the shuttle baseline system, a maximum heat rejection of 76,600 Btu/hr was obtained in segmented tests under the expected worst case design environments. Testing of an alternate smaller two-sided radiation configuration yielded a maximum heat rejection of 52,931 Btu/hr under the maximum design environments.

Scheps, P. B.↗

A directional microphone array for acoustic studies of wind tunnel models

An end-fire microphone array that utilizes a digital time delay system has been designed and evaluated for measuring noise in wind tunnels. The directional response of both a four- and eight-element linear array of microphones has enabled substantial rejection of background noise and reverberations in the NASA Ames 40- by 80-foot wind tunnel. In addition, it is estimated that four- and eight-element arrays reject 6 and 9 dB, respectively, of microphone wind noise, as compared with a conventional omnidirectional microphone with nose cone. Array response to two types of jet engine models in the wind tunnel is presented. Comparisons of array response to loudspeakers in the wind tunnel and in free field are made.

Soderman, P. T.↗

Design analysis of levitation facility for space processing applications

Containerless processing facilities for the space laboratory and space shuttle are defined. Materials process examples representative of the most severe requirements for the facility in terms of electrical power, radio frequency equipment, and the use of an auxiliary electron beam heater were used to discuss matters having the greatest effect upon the space shuttle pallet payload interfaces and envelopes. Improved weight, volume, and efficiency estimates for the RF generating equipment were derived. Results are particularly significant because of the reduced requirements for heat rejection from electrical equipment, one of the principal envelope problems for shuttle pallet payloads. It is shown that although experiments on containerless melting of high temperature refractory materials make it desirable to consider the highest peak powers which can be made available on the pallet, total energy requirements are kept relatively low by the very fast processing times typical of containerless experiments and allows consideration of heat rejection capabilities lower than peak power demand if energy storage in system heat capacitances is considered. Batteries are considered to avoid a requirement for fuel cells capable of furnishing this brief peak power demand.

Frost, R. T.↗

Parametric test of a zirconium (4) oxide-polyacrylic acid dual layer hyperfiltration membrane with spacecraft washwater

Performance data consisting of solute rejections and product flux were measured, as dependent on the operation parameters. These parameters and ranges were pressure (500,000 n/m2 to 700,000 n/m2), temperature (74 C to 95 C), velocity (1.6 M/sec to 10 M/sec), and concentration (up to 14x). Tests were carried out on analog washwater. Data presented include rejections of organic materials, ammonia, urea, and an assortment of ions. The membrane used was deposited in situ on a porcelain ceramic substrate.

Brandon, C. A.↗

Phase 1 engineering and technical data report for the thermal control extravehicular life support system

A shuttle EVLSS Thermal Control System (TCS) is defined. Thirteen heat rejection subsystems, thirteen water management subsystems, nine humidity control subsystems, three pressure control schemes and five temperature control schemes are evaluated. Sixteen integrated TCS systems are studied, and an optimum system is selected based on quantitative weighting of weight, volume, cost, complexity and other factors. The selected sybsystem contains a sublimator for heat rejection, a bubble expansion tank for water management, and a slurper and rotary separator for humidity control. Design of the selected subsystem prototype hardware is presented.

Source record↗

Thermal control extravehicular life support system

The results of a comprehensive study which defined an Extravehicular Life Support System Thermal Control System (TCS) are presented. The design of the prototype hardware and a detail summary of the prototype TCS fabrication and test effort are given. Several heat rejection subsystems, water management subsystems, humidity control subsystems, pressure control schemes and temperature control schemes were evaluated. Alternative integrated TCS systems were studied, and an optimum system was selected based on quantitative weighing of weight, volume, cost, complexity and other factors. The selected subsystem contains a sublimator for heat rejection, bubble expansion tank for water management, a slurper and rotary separator for humidity control, and a pump, a temperature control valve, a gas separator and a vehicle umbilical connector for water transport. The prototype hardware complied with program objectives.

Source record↗

Electrical power generation subsystem for Space Shuttle Orbiter

The requirements, capabilities, and design of the Space Shuttle Orbiter electrical power generation (EPG) subsystem are presented. The Orbiter EPG subsystem is designed to have the flexibility to supply the basic Orbiter electrical loads and the power requirements of the payloads which, in some cases, are completely dependent on the Orbiter for both power and heat rejection. These needs are supplied by three hydrogen/oxygen fuel cell powerplants (FCPs), having the capability of providing a total of 14 kW average and up to 24 kW peak in the basic Orbiter configuration. Kits permit dedication of one FCP to the payload by providing an additional reactant tank pair for a seven-day mission and additional heat rejection capability.

Blaski, M. F.↗

Parametric evaluation of a dual-layer dynamic hyperfiltration membrane for recovery of spacecraft wash water at elevated temperature

Performance data consisting of solute rejections and product flux have been measured, as dependent on the operational parameters. These parameters were pressure, 5,000,000 N/sq m (750 psia) to 7,000,000 N/sq m (1040 psia); temperature, 347 K (165 F) to 368 K (200 F); velocity, 1.6 m/s to 10 m/s; and concentration (up to 14x). Tests were carried out on analog wash water. Data taken include rejections of organic materials (TOC), ammonia, urea, and an assortment of ions. The membrane used was a dual-layer, polyacrylic acid over zirconium oxide, deposited in situ on a porcelain ceramic substrate.

Brandon, C. A.↗

The effects of out-of-field radiation on earth-observing telescopes

The stray radiation rejection requirements for the Synchronous Earth Observation Satellite telescope were determined and compared with estimated stray radiation rejection performance. It was found that normal baffle design practice and 0.05 wavelength rms surface roughness on the mirrors is adequate to prevent stray light from limiting the telescope measurements as long as the sun is 10 deg or more from the edge of the field of view for a baffle tube length-to-aperture diameter ratio of 6.

Young, P. J.↗

Correlation microphone for measuring airframe noise in large-scale wind tunnels

A correlation microphone arrangement was used in the test section of the Ames 7- by 10-Foot and 40- by 80-Foot Wind Tunnels in an attempt to reject the reverberant and wind noise. The tests in the 7- by 10-foot wind tunnel covered a frequency range from 400 Hz to 8 kHz while the tests in the 40- by 80-foot tunnel covered the range from 31.5 to 800 Hz. Examination of the experimental data plus calculations of cross-correlations due to reflective noise indicate that the correlation microphone is effective in rejecting microphone wind noise and reverberant noise even at low frequencies, and that the low-frequency background noise monitored by the correlation microphone is reflected noise with a preferred direction from the tunnel drive system. Design studies indicate that this tunnel drive noise can be reduced substantially through suitable modification of the drive fans and acoustical treatment of the nacelles that house these fans.

Ahtye, W. F.↗

Deployable radiators for waste heat dissipation from Shuttle payloads

Thermal control of Shuttle instruments will require the use of a pumped fluid space radiator system to reject large quantities of waste heat. Many payloads, however, will have insufficient vehicle surface area available for radiators to reject this waste heat and will, therefore, require the use of deployed panels. It is desirable to utilize modularized, deployable radiator systems which have a high degree of configuration and component commonality to minimize the design, development, and fabrication costs. Prototypes of two radiator systems which meet these criteria are currently under development for Shuttle payload utilization: a 'rigid' radiator system which utilizes aluminum honeycomb panels of the Shuttle Orbiter configuration that are deployed by an Apollo Telescope Mount type scissors mechanism; and two 'flexible' radiator systems which use panels constructed from flexible metal/dielectric composite materials that are deployed by 'unrolling' or 'extending' in orbit. Detailed descriptions of these deployable radiator systems, along with design and performance features, are presented.

Cox, R. L.↗

Additional studies of forest classification accuracy as influenced by multispectral scanner spatial resolution

First, an analysis of forest feature signatures was used to help explain the large variation in classification accuracy that can occur among individual forest features for any one case of spatial resolution and the inconsistent changes in classification accuracy that were demonstrated among features as spatial resolution was degraded. Second, the classification rejection threshold was varied in an effort to reduce the large proportion of unclassified resolution elements that previously appeared in the processing of coarse resolution data when a constant rejection threshold was used for all cases of spatial resolution. For the signature analysis, two-channel ellipse plots showing the feature signature distributions for several cases of spatial resolution indicated that the capability of signatures to correctly identify their respective features is dependent on the amount of statistical overlap among signatures. Reductions in signature variance that occur in data of degraded spatial resolution may not necessarily decrease the amount of statistical overlap among signatures having large variance and small mean separations. Features classified by such signatures may thus continue to have similar amounts of misclassified elements in coarser resolution data, and thus, not necessarily improve in classification accuracy.

Sadowski, F. E.↗

Auxiliary Payload Power System thermal control

The Auxiliary Payload Power System (APPS) provides supplementary power and cooling to Space Processing Application (SPA) experiments to be mounted in the APPS and the Spacelab in the Shuttle Payload Bay. SPA experiment operations are planned for early Shuttle flights. This paper presents thermal control study results for preliminary analysis and design definition of the APPS. A 100/sq m, three-wing, pumped-fluid, deployable radiator with separate APPS equipment and SPA experiments coolant loops was selected as the baseline. The system is capable of rejecting the heat (approximately 26 kw) associated with the production and consumption of approximately 16 kw of electrical power produced by the APPS fuel cells for a worst case radiator orientation. For the most favorable orientation, the heat rejection and power capability approach 38 and 24 kw, respectively. Alternate approaches were evaluated, such as heat pipes for the radiator and alternate fluids for the coolant loops. Emphasis was placed on using Shuttle developed hardware: coolant pumps, heat exchangers, fluids, and radiator technology.

Nagel, R. G.↗

Urea transport through composite polyallylamine membranes

Polyallylamine composite reverse osmosis membranes were prepared by plasma polymerization and deposition onto small-pored cellulose acetate/cellulose nitrate films. The polyallylamine coated the porous substrate with a thin uniform polymer film which exhibited water permeability and urea rejection, of interest because of the potential application of reverse osmosis to urine purification in closed environmental systems. The flux of C-14 labeled urea was studied under the influence of osmotic gradients provided by sodium chloride solutions. The urea flux was found to be enhanced by an osmotic pressure gradient in the same direction and diminished, but not prevented, by an opposing osmotic pressure gradient. Consideration is given to the mechanism of the urea transport, as well as to the influence of concentration polarization on the experimental results. The minimization of coupled flow in pores of a critical size range is apparently necessary to improve urea rejection.

Ballou, E. V.↗

Sizing-tube-fin space radiators

Temperature and size considerations of the tube fin space radiator were characterized by charts and equations. An approach of accurately assessing rejection capability commensurate with a phase A/B level output is reviewed. A computer program, based on Mackey's equations, is also presented which sizes the rejection area for a given thermal load. The program also handles the flow and thermal considerations of the film coefficient.

Peoples, J. A.↗

A directional filter diplexer using optical techniques for millimeter to submillimeter wavelengths

An optical diplexer for injection of a local oscillator into a mixer, useful in the submillimeter and short millimeter range, is described. It has very low insertion loss for both the signal and local oscillator (LO) and high rejection of LO noise. The measured performance of a unit tested at 337 GHz indicates a loss of about 0.2 dB for both inputs and 20-dB noise rejection.

Erickson, N. R.↗

Thermal analysis of a high energy propulsion system /hydrazine and liquid fluorine/ for a rover class Mars Orbiter

Maintaining cryogenic fluorine at a -189 C during the interplanetary cruise period to Mars is a major thermal problem. At this low temperature the heat rejection by radiation is severely limited and the allowable thermal load to the fluorine tank is less than approximately 8 watts. Previous studies generally constrain the spacecraft to an inline tank configuration which tends to maximize the fluorine tank's view and heat rejection to space. With the Inertial Upper Stage, sufficient stack height may not be available on the Shuttle for an inline tank configuration. Therefore, this study addresses the more thermally constraining side by side tank configuration.

Stultz, J. W.↗