Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

NDE Imaging of Time Differential Terahertz Waves

Natural voids are present in the vicinity of a conathane interface that bonds two different foam materials. These voids are out of focus with the terahertz imaging system and multiple optical reflections also make it difficult to determine their depths. However, waves passing through the top foam article at normal incidence are partially reflected at the denser conathane layer prior to total reflection at the tank s wall. Reflections embedded in the oscillating noise segment prior to the main signals can be extracted with dual applications of filtering and time derivative. Void's depth is computed from direct path's time of flight.

Trinh, Long B.↗

Covert laser remote sensing and vibrometry

Designs of single-beam laser vibrometry systems and methods. For example, a method for detecting vibrations of a target based on optical sensing is provided to include operating a laser to produce a laser probe beam at a laser frequency and modulated at a modulation frequency onto a target; collecting light at or near the laser to collect light from the target while the target is being illuminated by the laser probe beam through an optical receiver aperture; using a narrow-band optical filter centered at the laser frequency to filter light collected from the optical receiver aperture to transmit light at the laser frequency while blocking light at other frequencies; using an optical detector to convert filtered light from the narrow-band optical filter to produce a receiver electrical signal; using a lock-in amplifier to detect and amplify the receiver electrical signal at the modulation frequency while rejecting signal components at other frequencies to produce an amplified receiver electrical signal; processing the amplified receiver electrical signal to extract information on vibrations of the target carried by reflected laser probe beam in the collected light; and controlling optical power of the laser probe beam at the target to follow optical power of background illumination at the target.

Maleki, Lutfollah↗

Lidar Observations of Atmospheric CO2 Column During 2014 Summer Flight Campaigns

Advanced knowledge in atmospheric CO2 is critical in reducing large uncertainties in predictions of the Earth' future climate. Thus, Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) from space was recommended by the U.S. National Research Council to NASA. As part of the preparation for the ASCENDS mission, NASA Langley Research Center (LaRC) and Exelis, Inc. have been collaborating in development and demonstration of the Intensity-Modulated Continuous-Wave (IM-CW) lidar approach for measuring atmospheric CO2 column from space. Airborne laser absorption lidars such as the Multi-Functional Fiber Laser Lidar (MFLL) and ASCENDS CarbonHawk Experiment Simulator (ACES) operating in the 1.57 micron CO2 absorption band have been developed and tested to obtain precise atmospheric CO2 column measurements using integrated path differential absorption technique and to evaluate the potential of the space ASCENDS mission. This presentation reports the results of our lidar atmospheric CO2 column measurements from 2014 summer flight campaign. Analysis shows that for the 27 Aug OCO-2 under flight over northern California forest regions, significant variations of CO2 column approximately 2 ppm) in the lower troposphere have been observed, which may be a challenge for space measurements owing to complicated topographic condition, heterogeneity of surface reflection and difference in vegetation evapotranspiration. Compared to the observed 2011 summer CO2 drawdown (about 8 ppm) over mid-west, 2014 summer drawdown in the same region measured was much weak (approximately 3 ppm). The observed drawdown difference could be the results of the changes in both meteorological states and the phases of growing seasons. Individual lidar CO2 column measurements of 0.1-s integration were within 1-2 ppm of the CO2 estimates obtained from on-board in-situ sensors. For weak surface reflection conditions such as ocean surfaces, the 1- s integrated signal-to-noise ratio (SNR) of lidar measurements at 11 km altitude reached 376, which was equivalent to a 10-s CO2 error 0.33 ppm. For the entire processed 2014 summer flight campaign data, the mean differences between lidar remote sensed and in-situ estimated CO2 values were about -0.013 ppm. These results indicate that current laser absorption lidar approach could meet space measurement requirements for CO2 science goals.

Lin, Bing↗

Terrestrial Planet Optical Phase Curves: I. Direct Measurements of the Earth

NASA’s EPOXI mission used the Deep Impact spacecraft to observe the disk-integrated Earth as an analog to terrestrial exoplanets’ appearance. The mission took five 24 hr observations in 2008–2009 at various phase angles(57°.7–86°.4)and ranges(0.11–0.34 au), of which three equatorial(E1, E4, E5)and two polar(P1, North and P2,South). The visible data taken by the HRIV instrument ranges from 0.3 to 1.0μm, taken trough seven spectral filters that have spectral widths of about 100 nm, and which are centered about 100 nm apart, from 350 to 950 nm. The disk-integrated, 24 hr averaged signal is used in a phase angle analysis. A Lambertian-reflecting, spherical planet model is used to estimate geometric albedo for every observation and wavelength. The geometric albedos range from 0.143(E1, 950 nm)to 0.353(P2, 350 nm)and show wavelength dependence. The equatorial observations have similar values, while the polar observations have higher values due to the ice in view. Therefore, equatorial observations can be predicted for other phase angles, but(Earth-like)polar views(with ice)would be underestimated.

Roderick De Cock↗

Free-space Forwarded-pump Entanglement Source Synchronization

We investigate entanglement source synchronization using a forwarded-pump signal sent over a 3.2-km free-space retro-reflected link. Results show sub-picosecond alignment between the sources. The paper considers several fundamental and practical aspects of this approach.

quantum entanglement↗

The Earth in Living Color - NASA’s Surface Biology and Geology Designated Observable

The Surface Biology and Geology (SBG) Designated Observable will transform our understanding of the global land surface, inland and coastal aquatic ecosystems through visible-to-shortwave infra-red imaging (VSWIR) spectroscopy and thermal infra-red (TIR) imaging. SBG is one of four high-priority observables recommended in the 2017 NASA Earth Science Decadal Survey t o address science questions on vegetation and aquatic ecosystem health, snow-cover dynamics, volcanic activity, and minerology. With a planned launch readiness date of 2028, SBG is currently in Pre-Phase A, with Level 1 requirements being developed for a two-spacecraft architecture, including an additional constellation pathfinder. The recommended architecture emerged from an extensive study (2018-2021) that engaged the research and applications community to consider the science questions and measurement objectives of the Decadal Survey. A Science and Applications Traceability Matrix was used as a basis for scoring candidate architectures, with inputs from four working groups that covered algorithms, applications, calibration and validation, and modeling. Two pathfinder studies, Modeling End-to-End Traceability in support of SBG (MEET-SBG) and Space-based Imaging Spectroscopy and Thermal pathfindER (SISTER) are providing pre-launch modeling tools and data for algorithm development to support science value trades. The architecture consists of one spacecraft hosting a wide-swath VSWIR imaging spectrometer providing 30-m ground-sample distance (GSD), a spectral range of 380-2500 nm (at 10 nm resolution), 16-day revisit with 400 signal-to-noise for VNIR and 250 for SWIR (at 25% reflectance). A separate spacecraft will host a wide swath thermal imager, with five to seven bands placed between 4-12 μm), with 60-m (GSD), 3- day revisit, and 0.2K noise-equivalent differential temperature (NeDT). A VNIR compact camera will be hosted on the TIR spacecraft to enable coincident TIR and VNIR observations. A constellation pathfinder will evaluate options for enabling VSWIR mission continuity using Small Sats or data buys. Partnerships with international space agencies contribute technology as well as improvements to temporal revisit. SBG, when launched, will be the first dedicated mission collecting the full spectra of the Earth’s ‘living color’ and will play a critical role in NASA’s Earth System Observatory.

David S Schimel↗

Control of Networked Traffic Flow Distribution - A Stochastic Distribution System Perspective

Networked traffic flow is a common scenario for urban transportation, where the distribution of vehicle queues either at controlled intersections or highway segments reflect the smoothness of the traffic flow in the network. At signalized intersections, the traffic queues are controlled by traffic signal control settings and effective traffic lights control would realize both smooth traffic flow and minimize fuel consumption. Funded by the Energy Efficient Mobility Systems (EEMS) program of the Vehicle Technologies Office of the US Department of Energy, we performed a preliminary investigation on the modelling and control framework in context of urban network of signalized intersections. In specific, we developed a recursive input-output traffic queueing models. The queue formation can be modeled as a stochastic process where the number of vehicles entering each intersection is a random number. Further, we proposed a preliminary B-Spline stochastic model for a one-way single-lane corridor traffic system based on theory of stochastic distribution control.. It has been shown that the developed stochastic model would provide the optimal probability density function (PDF) of the traffic queueing length as a dynamic function of the traffic signal setting parameters. Based upon such a stochastic distribution model, we have proposed a preliminary closed loop framework on stochastic distribution control for the traffic queueing system to make the traffic queueing length PDF follow a target PDF that potentially realizes the smooth traffic flow distribution in a concerned corridor.

Wang, Hong↗

Scanning Mobility Particle Sizer-Portable Optical Particle Spectrometer Intercomparison Field Campaign Report

A portable optical particle spectrometer (POPS) has recently been acquired by the United Kingdom Meteorological (UK Met) Office with the intention of mounting it on an unmanned aerial vehicle (UAV) for atmospheric aerosol research. Before conducting research with the new instrument, an intercomparison has been conducted to test the performance of the POPS against a scanning mobility particle sizer (SMPS) — a veteran and well-characterized particle sizer. As part of the Cloud-Aerosol-Radiation Interactions and Forcing (CLARIFY) campaign, the POPS was installed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility mobile site on Ascension Island in the South Atlantic Ocean, alongside an ARM-operated SMPS. Both instruments sampled continuously from 20 August to 9 September, 2017. The SMPS and the POPS were connected to a common aerosol inlet; however, in the case of the SMPS, the sample air was dried before it entered the instrument. The POPS is a miniaturized optical particle counter designed specifically for use in balloon and UAV applications. The instrument is fully described in Goa et al. (2016) and so is only briefly described here. The POPS samples particles by drawing air through an inlet tube into an optical chamber, where it is illuminated by a 405nm laser. A sheath air flow is used to focus the sample air into the center of the laser beam, and the sample flow is maintained at a near-constant rate by an onboard pump. Side-scattered laser light is reflected into a photomultiplier tube by a hemispherical mirror, and the signal amplitude recorded by a data logger. Individual particle sizes are then inferred by comparing the recorded signal amplitudes to scattering amplitudes calculated using Mie theory. In common with other optical particle counters, the POPS size distributions are influenced by the refractive index used in the Mie calculations. The POPS is calibrated by the manufacturers (Handix Scientific) using latex spheres, with a refractive index (RI) of 1.615+0.001i. Sampling aerosols with a different refractive index, particularly if they are strongly absorbing, will result in significant uncertainties/errors in the particle size distributions (PSDs). We have therefore used scattering amplitude curves (calculated by Handix) for more absorbing aerosols, with an RI of 1.54+0.027i, which is expected to be more representative of the biomass-burning aerosol particles sampled at the ARM site during the CLARIFY campaign. In contrast to the POPS, the SMPS measures particle size using the differential mobility technique after applying an electrical charge to aerosol particles. The method is independent of the refractive index (Ruzer 2013).

CLARIFY, portable optical particle spectrometer, s↗

Method and device for detection of condition of brushless motors and generators

A method and device for determining the position of a rotor in a brushless motor is provided. The method generally includes: injecting electrical signals into a stator of the brushless motor; measuring scattering parameters reflected back from the stator, wherein the scattering parameters are influenced by the near-field dynamics impaired by the motor; and comparing the measured scattering parameters to a predetermined data set of scattering parameters for known rotor positions to determine the position of the rotor. The method and device is also suitable for determining a condition of a motor or a generator.

Haupt, Justine Elaine↗

Simulation of X-ray transient absorption for following vibrations in coherently ionized F 2 molecules

We report femtosecond and attosecond X-ray transient absorption experiments are becoming increasingly sophisticated tools for probing nuclear dynamics. In this work, we explore and develop theoretical tools needed for interpretation of such spectra,in order to characterize the vibrational coherences that result from ionizing a molecule in a strong IR field. Ab initio data for F 2 is combined with simulations of nuclear dynamics, in order to simulate time-resolved X-ray absorption spectra for vibrational wavepackets after coherent ionization at 0 K and at finite temperature. Dihalogens pose rather difficult electronic structure problems, and the issues encountered in this work will be reflective of those encountered with any core–valence excitation simulation when a bond is breaking. The simulations reveal a strong dependence of the X-ray absorption maximum on the locations of the vibrational wave packets. A Fourier transform of the simulated signal shows features at the overtone frequencies of both the neutral and the cation, which reflect spatial interferences of the vibrational eigenstates. This provides a direct path for implementing ultrafast X-ray spectroscopic methods to visualize coherent nuclear dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Assessment of Suomi-NPP VIIRS On-orbit Radiometric Performance

The Visible-Infrared Imaging Radiometer Suite (VIIRS) is a key instrument on-board the Suomi National Polar-orbiting Partnership (NPP) spacecraft that was launched on October 28th 2011. VIIRS was designed to provide moderate and imaging resolution of most of the globe twice daily. It is a wide-swath (3,040 km) cross-track scanning radiometer with spatial resolutions of 370.and 740 m at nadir for imaging and moderate bands, respectively. It has 22 spectral bands covering the spectrum between 0.412 11m and 12.01 11m, including 14 reflective solar bands (RSB), 7 thermal emissive bands (TEB), and 1 day-night band (ON B). VIIRS observations are used to generate 22 environmental data products (EORs). This paper will briefly describe NPP VIIRS calibration strategies performed by the independent government team, for the initial on-orbit Intensive Calibration and Validation (ICV) activities. In addition, this paper will provide an early assessment of the sensor on-orbit radiometric performance, such as the sensor signal to noise ratios (SNRs), dual gain transition verification, dynamic range and linearity, reflective bands calibration based on the solar diffuser (SO) and solar diffuser stability monitor (SOSM), and emissive bands calibration based on the on-board blackbody calibration (OBC). A comprehensive set of performance metrics generated during the pre-launch testing program will be compared to VIIRS on-orbit early performance, and a plan for future cal/val activities and performance enhancements will be presented.

Oudrari, Hassan↗

Optical distance measuring instrument

An optical instrument, such as a stability monitor or a target range finder, uses an unstabilized laser to project a composite optical signal of coherent light having two naturally occurring longitudinal mode components. A beamsplitter divides the signal into a reference beam which is directed toward one photodetector and a transmitted beam which illuminates and is reflected from a distant target onto a second photodetector optically isolated from the first photodetector. Both photodetectors are operated on the square law principle to provide electrical signals modulated at a frequency equal to the separation between the frequencies of the two longitudinal mode components of the optical signal projected by the laser. Slight movement of the target may be detected and measured by electrically monitoring the phase difference between the two signals provided by the photodetectors and the range of the target measured with the aid of a microprocessor by changing the separation between the longitudinal modes by shifting the length of the resonator cavity in an iterative series of increments.

Abshire, J. B.↗

The influence of irregular terrain on infrasonic propagation in the troposphere

The relations describing the reflection of three-dimensional acoustic ray paths impinging on a non-flat surface are derived and used to approximate the propagation of infrasonic signals over irregular terrain in the geometric limit. The influence of non-flat ground is strongest for those paths that reflect off the surface multiple times, such as those in the tropospheric waveguide; however, notable differences in source and receiver elevations for stratospheric and thermospheric paths can produce notable differences in travel times and arrival amplitudes. The interaction of ray paths with topographical features is investigated using a simple hill to demonstrate the impact of topography on propagation within an azimuthal plane, as well as cases in which the ground surface interaction deflects the path out of the azimuthal plane. Finally, broadband waveform predictions are compared with observations for an event in the western U.S., and a statistical analysis of scattering losses due to interaction with topography in the limit of geometric acoustics is used to improve the agreement between predicted and observed infrasonic signals.

47 OTHER INSTRUMENTATION↗

An experimental study of the temporal statistics of radio signals scattered by rain

A fixed-beam bistatic CW experiment designed to measure the temporal statistics of the volume reflectivity produced by hydrometeors at several selected altitudes, scattering angles, and at two frequencies (3.6 and 7.8 GHz) is described. Surface rain gauge data, local meteorological data, surveillance S-band radar, and great-circle path propagation measurements were also made to describe the general weather and propagation conditions and to distinguish precipitation scatter signals from those caused by ducting and other nonhydrometeor scatter mechanisms. The data analysis procedures were designed to provide an assessment of a one-year sample of data with a time resolution of one minute. The cumulative distributions of the bistatic signals for all of the rainy minutes during this period are presented for the several path geometries.

Hubbard, R. W.↗

Air-coupled acoustic radiation force for non-contact generation of broadband mechanical waves in soft media

A non-contact method for efficient, non-invasive excitation of mechanical waves in soft media is proposed, in which we focus an ultrasound (US) signal through air onto the surface of a medium under study. The US wave reflected from the air/medium interface provides radiation force to the medium surface that launches a transient mechanical wave in the transverse (lateral) direction. The type of mechanical wave is determined by boundary conditions. To prove this concept, a home-made 1 MHz piezo-ceramic transducer with a matching layer to air sends a chirped US signal centered at 1 MHz to a 1.6 mm thick gelatin phantom mimicking soft biological tissue. A phase-sensitive (PhS)-optical coherence tomography system is used to track/image the mechanical wave. The reconstructed transient displacement of the mechanical wave in space and time demonstrates highly efficient generation, thus offering great promise for non-contact, non-invasive characterization of soft media, in general, and for elasticity measurements in delicate soft tissues and organs in bio-medicine, in particular.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On-Orbit Noise Characterization of MODIS Reflective Solar Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS), launched on the Terra and Aqua spacecrafts, was designed to collect complementary and comprehensive measurements of the Earth's properties on a global scale. The 20 reflective solar bands (RSBs), covering a wavelength range from 0.41 to 2.1 micrometers, are calibrated on-orbit using regularly scheduled solar diffuser (SD) observations. Although primarily used for on-orbit gain derivation, the SD observations also facilitate the characterization of the detector signal-to-noise ratio (SNR). In addition to the calibration requirement of 2% for the reflectance factors and 5% for the radiances, the required SNRs are also specified for all RSB at their typical scene radiances. A methodology to characterize the on-orbit SNR for the MODIS RSB is presented. Overall performance shows that a majority of the RSB continue to meet the specification, therefore performing well. A temporal decrease in the SNR, observed in the short-wavelength bands, is attributed primarily to the decrease in their detector responses. With the exception of the inoperable and noisy detectors in band 6 identified prelaunch, the detectors of AquaMODIS RSB perform better than TerraMODIS. The approach formulated for on-orbit SNR characterization can also be used by other sensors that use on-board SDs for their on-orbit calibration (e.g., Suomi National Polar-Orbiting Partnership [SNPP]-Visible Infrared Imaging Radiometer Suite).

Reflective↗

A Semianalytical Ocean Color Inversion Algorithm with Explicit Water Column Depth and Substrate Reflectance Parameterization

A semianalytical ocean color inversion algorithm was developed for improving retrievals of inherent optical properties (IOPs) in optically shallow waters. In clear, geometrically shallow waters, light reflected off the seafloor can contribute to the water-leaving radiance signal. This can have a confounding effect on ocean color algorithms developed for optically deep waters, leading to an overestimation of IOPs. The algorithm described here, the Shallow Water Inversion Model (SWIM), uses pre-existing knowledge of bathymetry and benthic substrate brightness to account for optically shallow effects. SWIM was incorporated into the NASA Ocean Biology Processing Group's L2GEN code and tested in waters of the Great Barrier Reef, Australia, using the Moderate Resolution Imaging Spectroradiometer (MODIS) Aqua time series (2002-2013). SWIM-derived values of the total non-water absorption coefficient at 443 nm, at(443), the particulate backscattering coefficient at 443 nm, bbp(443), and the diffuse attenuation coefficient at 488 nm, Kd(488), were compared with values derived using the Generalized Inherent Optical Properties algorithm (GIOP) and the Quasi-Analytical Algorithm (QAA). The results indicated that in clear, optically shallow waters SWIM-derived values of at(443), bbp(443), and Kd(443) were realistically lower than values derived using GIOP and QAA, in agreement with radiative transfer modeling. This signified that the benthic reflectance correction was performing as expected. However, in more optically complex waters, SWIM had difficulty converging to a solution, a likely consequence of internal IOP parameterizations. Whilst a comprehensive study of the SWIM algorithm's behavior was conducted, further work is needed to validate the algorithm using in situ data.

Great Barrier Reef↗

A new scheme of force reflecting control

A new scheme of force reflecting control has been developed that incorporates position-error-based force reflection and robot compliance control. The operator is provided with a kinesthetic force feedback which is proportional to the position error between the operator-commanded and the actual position of the robot arm. Robot compliance control, which increases the effective compliance of the robot, is implemented by low pass filtering the outputs of the force/torque sensor mounted on the base of robot hand and using these signals to alter the operator's position command. This position-error-based force reflection scheme combined with shared compliance control has been implemented successfully to the Advanced Teleoperation system consisting of dissimilar master-slave arms. Stability measurements have demonstrated unprecedentedly high force reflection gains of up to 2 or 3, even though the slave arm is much stiffer than operator's hand holding the force reflecting hand controller. Peg-in-hole experiments were performed with eight different operating modes to evaluate the new force-reflecting control scheme. Best task performance resulted with this new control scheme.

Kim, Won S.↗