Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

SU-C-17A-03: Evaluation of Deformable Image Registration Methods Between MRI and CT for Prostate Cancer Radiotherapy

Purpose: We evaluated the performance of two commercially available and one open source B-Spline deformable image registration (DIR) algorithms between T2-weighted MRI and treatment planning CT using the DICE indices. Methods: CT simulation (CT-SIM) and MR simulation (MR-SIM) for four prostate cancer patients were conducted on the same day using the same setup and immobilization devices. CT images (120 kVp, 500 mAs, voxel size = 1.1x1.1x3.0 mm3) were acquired using an open-bore CT scanner. T2-weighted Turbo Spine Echo (T2W-TSE) images (TE/TR/α = 80/4560 ms/90°, voxel size = 0.7×0.7×2.5 mm3) were scanned on a 1.0T high field open MR-SIM. Prostates, seminal vesicles, rectum and bladders were delineated on both T2W-TSE and CT images by the attending physician. T2W-TSE images were registered to CT images using three DIR algorithms, SmartAdapt (Varian), Velocity AI (Velocity) and Elastix (Klein et al 2010) and contours were propagated. DIR results were evaluated quantitatively or qualitatively by image comparison and calculating organ DICE indices. Results: Significant differences in the contours of prostate and seminal vesicles were observed between MR and CT. On average, volume changes of the propagated contours were 5%, 2%, 160% and 8% for the prostate, seminal vesicles, bladder and rectum respectively. Corresponding mean DICE indices were 0.7, 0.5, 0.8, and 0.7. The intraclass correlation coefficient (ICC) was 0.9 among three algorithms for the Dice indices. Conclusion: Three DIR algorithms for CT/MR registration yielded similar results for organ propagation. Due to the different soft tissue contrasts between MRI and CT, organ delineation of prostate and SVs varied significantly, thus efforts to develop other DIR evaluation metrics are warranted. Conflict of interest: Submitting institution has research agreements with Varian Medical System and Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-E-J-231: Comparison of Delineation Variability of Soft Tissue Volume and Position in Head-And-Neck Between Two T1-Weighted Pulse Sequences Using An MR-Simulator with Immobilization

Purpose: There is growing interests in applying MR-simulator(MR-sim) in radiotherapy but MR images subject to hardware, patient and pulse sequence dependent geometric distortion that may potentially influence target definition. This study aimed to evaluate the influence on head-and-neck tissue delineation, in terms of positional and volumetric variability, of two T1-weighted(T1w) MR sequences on a 1.5T MR-sim Methods: Four healthy volunteers were scanned (4 scans for each on different days) using both spin-echo (3DCUBE, TR/TE=500/14ms, TA=183s) and gradient-echo sequences (3DFSPGR, TE/TR=7/4ms, TA=173s) with identical coverage, voxel-size(0.8×0.8×1.0mm3), receiver-bandwidth(62.5kHz/pix) and geometric correction on a 1.5T MR-sim immobilized with personalized thermoplastic cast and head-rest. Under this setting, similar T1w contrast and signal-to-noise ratio were obtained, and factors other than sequence that might bias image distortion and tissue delineation were minimized. VOIs of parotid gland(PGR, PGL), pituitary gland(PIT) and eyeballs(EyeL, EyeR) were carefully drawn, and inter-scan coefficient-of-variation(CV) of VOI centroid position and volume were calculated for each subject. Mean and standard deviation(SD) of the CVs for four subjects were compared between sequences using Wilcoxon ranksum test. Results: The mean positional(<4%) and volumetric(<7%) CVs varied between tissues, majorly dependent on tissue inherent properties like volume, location, mobility and deformability. Smaller mean volumetric CV was found in 3DCUBE, probably due to its less proneness to tissue susceptibility, but only PGL showed significant difference(P<0.05). Positional CVs had no significant differences for all VOIs(P>0.05) between sequences, suggesting volumetric variation might be more sensitive to sequence-dependent delineation difference. Conclusion: Although 3DCUBE is considered less prone to tissue susceptibility-induced artifact and distortion, our preliminary data showed that both sequences had insignificant differences on positional and volumetric CV in most head-and-neck tissues except for PGL. This study is majorly limited in its small sample size. Influences of image contrasts(T1w v.s. T2w) and inter-observer difference have to be further investigated.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-01: Accurate Prediction of CT Tube Current Modulation: Estimating Tube Current Modulation Schemes for Voxelized Patient Models Used in Monte Carlo Simulations

Purpose: Most patient models used in Monte Carlo-based estimates of CT dose, including computational phantoms, do not have tube current modulation (TCM) data associated with them. While not a problem for fixed tube current simulations, this is a limitation when modeling the effects of TCM. Therefore, the purpose of this work was to develop and validate methods to estimate TCM schemes for any voxelized patient model. Methods: For 10 patients who received clinically-indicated chest (n=5) and abdomen/pelvis (n=5) scans on a Siemens CT scanner, both CT localizer radiograph (“topogram”) and image data were collected. Methods were devised to estimate the complete x-y-z TCM scheme using patient attenuation data: (a) available in the Siemens CT localizer radiograph/topogram itself (“actual-topo”) and (b) from a simulated topogram (“sim-topo”) derived from a projection of the image data. For comparison, the actual TCM scheme was extracted from the projection data of each patient. For validation, Monte Carlo simulations were performed using each TCM scheme to estimate dose to the lungs (chest scans) and liver (abdomen/pelvis scans). Organ doses from simulations using the actual TCM were compared to those using each of the estimated TCM methods (“actual-topo” and “sim-topo”). Results: For chest scans, the average differences between doses estimated using actual TCM schemes and estimated TCM schemes (“actual-topo” and “sim-topo”) were 3.70% and 4.98%, respectively. For abdomen/pelvis scans, the average differences were 5.55% and 6.97%, respectively. Conclusion: Strong agreement between doses estimated using actual and estimated TCM schemes validates the methods for simulating Siemens topograms and converting attenuation data into TCM schemes. This indicates that the methods developed in this work can be used to accurately estimate TCM schemes for any patient model or computational phantom, whether a CT localizer radiograph is available or not. Funding Support: NIH Grant R01-EB017095; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski; Disclosures - Cynthia McCollough: Research Grant, Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-F-J-153: ACR MRI Phantom Test On a 1.5T MR-Simulator with Flexible Coils Setting and Performance Comparison to Volumetric Head Coil Setting

Purpose: To accommodate head-and-neck (HN) RT simulation scan with immobilization, sub-optimized flexible radiofrequency coils have to be used on an MR-sim rather than a volumetric head coil for diagnostic radiological (DR) applications. In this study, we present and compare ACR MRI phantom test with flexible coils setting (RT-setting) and volumetric head coil setting (DR-setting). Methods: Two 8-channel array coils were wrapped close to an ACR MRI phantom placed on a flat couch-top in RT-setting for acquisition. ACR MRI phantom tests were conducted 10 times for each setting on a 1.5T MR-sim. Sagittal localizer (TE/TR=20/200ms), axial T1 (TE/TR=20/500ms) and T2 scans (2TEs/TR=20,80/2000ms) were acquired (NEX=1). Acqusition and image analysis were conducted following ACR guidelines. Extra 10 RT-setting acquisitions were obtained by enabling prescan normalization. Results: For RT-setting without prescan normalization, all tests passed the ACR recommended criteria but image intensity uniformity. Geometric accuracy was 147.8±0.3mm and 191.0±0.4mm. Spatial resolution was 0.9mm. Slice thickness was 5.2mm±0.1mm (T1) and 5.1±0.1mm (T2). Slice position accuracy was 1.4±0.6mm, −2.2±0.3mm (T1), and 1.5±0.2mm, −2.2±0.2mm (T2). Image uniformity was 80.6%±2.6% (T1) and 80.2%±3.1% (T2) (criteria: ≥87.5% for 1.5T). Ghosting ratio was 0.0006±0.0004. Low contrast detectability was 30.7±1.7 (T1) and 22.6±3.0 (T2). Image uniformity (91.4%±4.2% and 91.8%±4.3%) and low contrast detectability (36.5±1.4 and 31.6±2.2) of DR-setting were better than RT-setting. Prescan normalization substantially improved image uniformity to 93.4%±0.2% and 93.4%±0.3%, but slightly compromised ghosting (0.0033±0.0004) and spatial resolution (0.9mm or 1.0mm) for RT-setting. Conclusion: Flexible coils setting for HN-RT simulation scan could successfully pass ACR criteria (prescan normalization enabled) and generally achieve comparable performance to volumetric coil setting, although compromise on low contrast detectability was observed probably due to the lower signal-to-noise ratio of the flexible coils. Our results could also serve as a reference baseline of high-field MR-sim QA performance under ACR guideline.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-15: Is the Reproducibility with Respect to Bone of Tumor Position at Simulation for Breath Hold CT Scans Correlated to the Reproducibility for Multiple Breath Hold CBCTs at Treatment in SBRT Thoracic Patients?

Purpose: To evaluate correlation between the reproducibility of tumor position under feedback guided voluntary deep inspiration breath hold gating at simulation and at treatment. Methods: All patients treated with breath hold (BH) have 3-6 BH CTs taken at simulation (sim). In addition, if the relationship between the tumor and nearby bony anatomy on treatment BH CT(or CBCT) is found to be greater than 5 mm different at treatment than it was at sim, a repeat BH CT is taken before treatment. We retrospectively analyzed the sim CTs for 19 patients who received BH SBRT lung treatments and had repeat BH CT on treatment. We evaluated the reproducibility of the tumor position during the simulation CTs and compared this to the reproducibility of the tumor position on the repeat treatment CT with our in-house CT alignment software (CT-Assisted Targeting for Radiotherapy). Results: Comparing the tumor position for multiple simulation BH CTs, we calculated: maximum difference (max) = 0.69cm; average difference (x) = 0.28cm; standard deviation (σ) = 0.18cm. Comparing the repeat BH CBCTs on treatment days we calculated: max = 0.44cm; x = 0.16cm; σ = 0.22cm. We also found that for 95% of our BH cases, the absolute variation in tumor position within the same imaging day was within 5mm of the range at the time of simulation and treatment. We found that 75% of the BH cases had less residual tumor motion on treatment days than at simulation. Conclusion: This suggests that a GTV contour based upon the residual tumor motion in multiple BH datasets plus 2 mm margin should be sufficient to cover the full range of residual tumor motion on treatment days.

60 APPLIED LIFE SCIENCES↗

WE-AB-202-11: Radiobiological Modeling of Tumor Response During Radiotherapy Based On Pre-Treatment Dynamic PET Imaging Data

Purpose: To evaluate the ability of a multiscale radiobiological model of tumor response to predict mid-treatment hypoxia images, based on pretreatment imaging of perfusion and hypoxia with [18-F]FMISO dynamic PET and glucose metabolism with [18-F]FDG PET. Methods: A mechanistic tumor control probability (TCP) radiobiological model describing the interplay between tumor cell proliferation and hypoxia (Jeong et al., PMB 2013) was extended to account for intra-tumor nutrient heterogeneity, dynamic cell migration due to nutrient gradients, and stromal cells. This extended model was tested on 10 head and neck cancer patients treated with chemoradiotherapy, randomly drawn from a larger MSKCC protocol involving baseline and mid-therapy dynamic PET scans. For each voxel, initial fractions of proliferative and hypoxic tumor cells were obtained by finding an approximate solution to a system of linear equations relating cell fractions to voxel-level FDG uptake, perfusion (FMISO K{sub 1}) and hypoxia (FMISO k{sub 3}). The TCP model then predicted their evolution over time up until the mid treatment scan. Finally, the linear model was reapplied to predict each lesion’s median hypoxia level (k{sub 3}[med,sim]) which in turn was compared to the FMISO k{sub 3}[med] measured at mid-therapy. Results: The average k3[med] of the tumors in pre-treatment scans was 0.0035 min{sup −1}, with an inter-tumor standard deviation of σ[pre]=0.0034 min{sup −1}. The initial simulated k{sub 3}[med,sim] of each tumor agreed with the corresponding measurements within 0.1σ[pre]. In 7 out of 10 lesions, the mid-treatment k{sub 3}[med,sim] prediction agreed with the data within 0.3σ[pre]. The remaining cases corresponded to the most extreme relative changes in k{sub 3}[med]. Conclusion: This work presents a method to personalize the prediction of a TCP model using pre-treatment kinetic imaging data, and validates the modeling of radiotherapy response by predicting changes in median hypoxia values during treatment. Variations from predicted response may be a useful biomarker, which should be further explored. Partially supported by NIH grant #1 R01 CA157770-01A1 and a grant from Varian Corporation.

60 APPLIED LIFE SCIENCES↗

An FPGA-based hardware accelerator supporting sensitive sequence homology filtering with profile hidden Markov models

Abstract Background Sequence alignment lies at the heart of genome sequence annotation. While the BLAST suite of alignment tools has long held an important role in alignment-based sequence database search, greater sensitivity is achieved through the use of profile hidden Markov models (pHMMs). Here, we describe an FPGA hardware accelerator, called HAVAC, that targets a key bottleneck step (SSV) in the analysis pipeline of the popular pHMM alignment tool, HMMER. Results The HAVAC kernel calculates the SSV matrix at 1739 GCUPS on a $$\sim$$ ∼ $3000 Xilinx Alveo U50 FPGA accelerator card, $$\sim$$ ∼ 227× faster than the optimized SSV implementation in nhmmer . Accounting for PCI-e data transfer data processing, HAVAC is 65× faster than nhmmer’s SSV with one thread and 35× faster than nhmmer with four threads, and uses $$\sim$$ ∼ 31% the energy of a traditional high end Intel CPU. Conclusions HAVAC demonstrates the potential offered by FPGA hardware accelerators to produce dramatic speed gains in sequence annotation and related bioinformatics applications. Because these computations are performed on a co-processor, the host CPU remains free to simultaneously compute other aspects of the analysis pipeline.

59 BASIC BIOLOGICAL SCIENCES↗

An optimized FM-index library for nucleotide and amino acid search

Abstract Background Pattern matching is a key step in a variety of biological sequence analysis pipelines. The FM-index is a compressed data structure for pattern matching, with search run time that is independent of the length of the database text. Implementation of the FM-index is reasonably complicated, so that increased adoption will be aided by the availability of a fast and flexible FM-index library. Results We present AvxWindowedFMindex (AWFM-index), a lightweight, open-source, thread-parallel FM-index library written in C that is optimized for indexing nucleotide and amino acid sequences. AWFM-index introduces a new approach to storing FM-index data in a strided bit-vector format that enables extremely efficient computation of the FM-index occurrence function via AVX2 bitwise instructions, and combines this with optional on-disk storage of the index’s suffix array and a cache-efficient lookup table for partial k-mer searches. The AWFM-index performs exact match count and locate queries faster than SeqAn3’s FM-index implementation across a range of comparable memory footprints. When optimized for speed, AWFM-index is $$\sim $$ ∼ 2–4x faster than SeqAn3 for nucleotide search, and $$\sim $$ ∼ 2–6x faster for amino acid search; it is also $$\sim $$ ∼ 4x faster with similar memory footprint when storing the suffix array in on-disk SSD storage. Conclusions AWFM-index is easy to incorporate into bioinformatics software, offers run-time performance parameterization, and provides clients with FM-index functionality at both a high-level (count or locate all instances of a query string) and low-level (step-wise control of the FM-index backward-search process). The open-source library is available for download at https://github.com/TravisWheelerLab/AvxWindowFmIndex.

59 BASIC BIOLOGICAL SCIENCES↗

Validation of simulated wave energy converter responses to focused waves

Focused waves are increasingly used as a design method to predict extreme loads for offshore structures, such as wave energy converters (WECs). However, the ability of computational methods to accurately simulate the prescribed focused waves and resulting wave structure interactions is not well validated. This study uses two computational fluid dynamic methods, WEC-Sim and STAR-CCM+, to evaluate the responses of two taut-moored WEC-like buoys to three different focused waves. WEC-Sim is a computationally efficient, mid-fidelity model, based on linearised potential flow theory. In contrast, STAR-CCM+ is a high-fidelity, three-dimensional, unsteady, Reynolds-averaged Navier–Stokes-based model. The two buoy geometries considered are a hemispherical-bottom cylinder and a truncated cylinder with a cylindrical moon pool. Three prescribed focused waves are generated in both codes, and the simulated displacements and mooring loads are obtained for each of the hydrodynamic bodies. The resulting STAR-CCM+ generated focused waves have approximately the same accuracy, in comparison with the analytic solution, as experimentally generated focused waves. The WEC-Sim simulated responses, when using viscous coefficients tuned to the measured displacements, are, on average, within 11.5% of experimentally measured values, whereas the STAR-CCM+ simulated responses are, on average, within 14.2% of the experimental values.

16 TIDAL AND WAVE POWER↗

Investigation of Nitrogen Absorption Rate and Nitride Growth on SRF Cavity Grade RRR Niobium as a Function of Furnace Temperature

The current state of the art processing of niobium superconducting radio frequency cavities with nitrogen diffusion is performed at 800 C in a furnace with a partial pressure of approximately ~20 mTorr of nitrogen. Multiple studies have shown the bulk of the nitrogen absorbed by the niobium forms a thick (1-3 microns) non-superconducting nitride layer which must be removed to produce optimal RF results. The depth profiling of interstitial nitrogen and surface nitrides has already been probed using SIMS measurements for this recipe. These measurements have been successfully modelled by extrapolating data from nitride growth studies performed at atmospheric pressure and temperatures above 1000 C.1 One open question is whether there is a diffusion-only zone at lower temperature in the ~20 mTorr range in which the niobium will absorb nitrogen but not create a non-superconducting nitride layer; or is the absorption of nitrogen only possible by first forming a nitride buffer layer which then frees up nitrogen for absorption which is what has been shown down to 600 C at atmospheric pressures on long time scales. A systematic study of absorption vs. temperature and correlated SIMS measurements is required to answer this question. We report on measurements of the parabolic rate constant vs. temperature from 400 C to 900 C of cavity grade niobium with metallurgically flat witness samples. Depth profiles of witness samples using SIMS are presented together with SEM imaging for nitride crystals and correlated with N absorption.

Reece, Charles↗

Determination of Light Water Reactor Fuel Burnup with the Isotope Ratio Method

For the current project to demonstrate that isotope ratio measurements can be extended to zirconium alloys used in LWR fuel assemblies we report new analyses on irradiated samples obtained from a reactor. Zirconium alloys are used for structural elements of fuel assemblies and for the fuel element cladding. This report covers new measurements done on irradiated and unirradiated zirconium alloys, Unirradiated zircaloy samples serve as reference samples and indicate starting values or natural values for the Ti isotope ratio measured. New measurements of irradiated samples include results for 3 samples provided by AREVA. New results indicate: 1. Titanium isotope ratios were measured again in unirradiated samples to obtain reference or starting values at the same time irradiated samples were analyzed. In particular, 49Ti/48Ti ratios were indistinguishably close to values determined several months earlier and to expected natural values. 2. 49Ti/48Ti ratios were measured in 3 irradiated samples thus far, and demonstrate marked departures from natural or initial ratios, well beyond analytical uncertainty, and the ratios vary with reported fluence values. The irradiated samples appear to have significant surface contamination or radiation damage which required more time for SIMS analyses. 3. Other activated impurity elements still limit the sample size for SIMS analysis of irradiated samples. The sub-samples chosen for SIMS analysis, although smaller than optimal, were still analyzed successfully without violating the conditions of the applicable Radiological Work Permit

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FINAL REPORT

Excellent progress was made in standardizing three complementary methods: Magnetic resonance imaging, x-ray micro CT, and MALDI imaging linear ion trap mass spectroscopy to image biomass and chemical, anatomical and functional changes that occur during pretreatment and hydrolysis. Magnetic resonance microscopy provides excellent images with as low as 5 uM resolution with hydrated biomass samples. We visualized dramatic changes in signal associated with the hydrolysis of the carbohydrates by strong acids. Quantitative diffusion approaches were used to probe more subtle structural changes in biomass. Diffusion tensor calculations reflect diffusion anisotropy and fractional anisotropy maps clearly show the longer range diffusion within the vessels compared to within the fiber cells. The diffusion is increased along the cell walls of the vessels. Suggesting that further research with NMR imaging should be pursued. X-ray CT provides excellent images at as low as 3.5 uM resolution from dried biomass. Small increases in surface area, and decreases in local density have been quantified in with wood after mild pretreatments; these changes are expected to be underestimates of the hydrated wood, due to the ~12% shrinkage that occurs upon drying untreated wood. MALDI-MS spectra show high ion intensities at most mass to charge ratios in untreated and pretreated woody material. MALDI-MSn is required to improve specificity and reduce background for imaging. MALDI-TOF is not specific enough for carbohydrate identification. Using MALDI-LIT/MSn we can readily identify oligomeric glucans and xylans and their fragmentation patterns as well as those of the glucuronic acid side chains of birch 4-O-methyl glucuronxylan. Imaging of glucan and xylan oligomers show that many contain isobaric ions with different distributions, indicating again that MSn is needed for accurate imaging of lignocellulosic materials. We are now starting to integrate the three imaging methods by using the same set of biomass samples imaged with all three methods, and using common analytical software to quantify parameters from the three dimensional images. In addition to the proposed experiments, we conducted imaging studies with a novel TOF-SIMS instrument available through collaborations with the AMOLF goup led by Ron Heeren at the FOM Institute in Amersterdam, Netherlands. ToF-SIMS was used to image intact cross sections of Populus stems with high spatial resolution, chemically selectivity. ToF-SIMS images were correlated with fluorescence microscopy which allowed for more positive ion identification.

09 BIOMASS FUELS↗

Campaign 1.7 Pu Aging. Development of Time of Flight Secondary Ion Mass Spectroscopy

The first application of Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS) to an aged plutonium surface has resulted in a rich set of surface chemistry data, as well as some unexpected results. FY15 was highlighted by not only the first mapping of hydrogen-containing features within the metal, but also a prove-in series of experiments using the system’s Sieverts Reaction Cell. These experiments involved successfully heating the sample to ~450 oC for nearly 24 hours while the sample was dosed several times with hydrogen, followed by an in situ ToF-SIMS analysis. During this year, the data allowed for better and more consistent identification of the myriad peaks that result from the SIMS sputter process. In collaboration with the AWE (U.K), the system was also fully aligned for sputter depth profiling for future experiments.

36 MATERIALS SCIENCE↗

GoldSim E-Area Low-Level Waste Facility Aquifer Zone Model Calibration Methodology

This report documents the development and calibration of the E-Area Low-Level Waste Facility (ELLWF) Gold Sim aquifer model. It provides a methodology on how a Gold Sim aquifer model can be calibrated to specific PORFLOW-based aquifer predictions. The calibration activity presented within this report focuses on the Slit Trench #06 (ST06) location that resides within the center set of Slit Trenches. This Gold Sim-based aquifer model is a generic model capable of being calibrated to any of the other trench locations within E-Area. In addition, subsequent activities (beyond the scope of this effort) will couple this GoldSim-based aquifer model to various GoldSim-based trench models, with the intent of performing stochastic analyses that couple all pertinent fate and transport processes from the ground surface up to the 100-m point of assessment (POA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved $b$-jet Energy Correction for $H \to b\bar{b}$ Searches at CDF

We present a method for improving the $b$-jet energy resolution in order to improve the signal sensitivity in searches for particles decaying to a $b$ quark and anti-$b$ quark. A correction function is computed for individual jets, which combines information from the secondary vertex tagger, the offline tracking and standard calorimeter-based jet-energy reconstruction algorithm in order to provide a more accurate measurement of the true $b$-quark energy. We apply the correction to Monte-Carlo-simulated jets in the process $WH \rightarrow \ell \nu b\bar b$ and find an improvement in both the mean and the resolution of the $b$-jet energy with respect to the $b$-quark energy. The correction improves the measured Higgs dijet invariant mass resolution from $\sim$ 15%(standard jet corrections) to $\sim$ 11%(improved jet corrections) in the Higgs mass range from 100 GeV/$c^2$ - 150 GeV/$c^2$. Using the corrected $b$-jet energies instead of the standard calorimeter-based $b$-jet energies results in a $\sim$ 9% improvement in the expected sensitivity for Higgs boson production cross section in the most sensitive search region of the $WH \rightarrow \ell \nu b\bar b$ analysis, which is two tagged jets and one charged central lepton.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multidimensional Diagnostics of the Interface Evolutions in Solid-State Lithium Batteries

All-solid-state lithium metal batteries hold tremendous potential as next-generation energy storage solutions. However, their performance is hindered by complex chemo-mechanical instabilities at the interface, which encompass electrolyte decomposition, loss of contact due to volume changes, and the growth of lithium filaments. Given the complexity of these failure mechanisms, it is imperative to employ multidimensional diagnostics that leverage a combination of tools capable of quantifying formed voids and filaments, identifying the chemical and mechanical properties of lithium dendrites and electrolyte decomposition products, as well as monitoring the evolution of these processes in situ. The primary objective of this project is to develop a comprehensive characterization platform for solid-state battery interfaces, integrating FIB-SEM tomography, ToF-SIMS, in-SEM nanoindentation, and in-SIMS AFM-based stiffness mapping to enable structural, chemical, and mechanical analyses. The project team has accomplished significant milestones, including: 1) The successful development of a characterization platform that combines FIB-SEM, ToF-SIMS, nanoindentation, and AFM. 2) The creation of solid-state cells at various scales. 3) Real-time visualization of the plating and stripping of lithium. 4) Operando analysis of the chemical composition and evolution of electrolyte decomposition products, encompassing intermediate and metastable species, at both the cathode and anode interfaces. 5) In situ analysis of mechanical properties coupled with chemical mapping. 6) The implementation of the multiscale characterization technique has yielded valuable insights into cell failure mechanisms and has led to the development of a solid-state lithium cell that exhibits exceptional durability, surpassing 2500 cycles. This project has resulted in 10 publications, 1 invention disclosure, 8 manuscripts under review or in preparation.

25 ENERGY STORAGE↗

Modeling and Design of the Triton OWC System (Final Report)

Two versions of the Triton Oscillating Water Column type device will be modeled in WEC Sim. First, a model of a wave-tank scale device which can be tuned and validated against tank test data. Second, a model of the deployment-scale device will be constructed following the method of the tank-scale device to ensure that relevant physics are captured. In the latter case, the geometry, PTO architecture, and other design details are not yet finalized, so the model will serve as a platform for design iteration as time and budget allows. A subset of this iteration will be automated using existing WEC-Sim capabilities. A primary focus of this work will be familiarizing Triton personnel with the WEC-Sim workflow and model details so that the model of the deployment device can continue to be enhanced after project end.

16 TIDAL AND WAVE POWER↗

A Letter of Intent to Build a MiniBooNE Near Detector: BooNE

There is accumulating evidence for a difference between neutrino and antineutrino oscillations at the $\sim 1$ eV$^2$ scale. The MiniBooNE experiment observes an unexplained excess of electron-like events at low energies in neutrino mode, which may be due, for example, to either a neutral current radiative interaction, sterile neutrino decay, or to neutrino oscillations involving sterile neutrinos and which may be related to the LSND signal. No excess of electron-like events ($-0.5 \pm 7.8 \pm 8.7$), however, is observed so far at low energies in antineutrino mode. Furthermore, global 3+1 and 3+2 sterile neutrino fits to the world neutrino and antineutrino data suggest a difference between neutrinos and antineutrinos with significant ($\sin^22\theta_{\mu \mu} \sim 35%$) $\bar \nu_\mu$ disappearance. In order to test whether the low-energy excess is due to neutrino oscillations and whether there is a difference between $\nu_\mu$ and $\bar \nu_\mu$ disappearance, we propose building a second MiniBooNE detector at (or moving the existing MiniBooNE detector to) a distance of $\sim 200$ m from the Booster Neutrino Beam (BNB) production target. With identical detectors at different distances, most of the systematic errors will cancel when taking a ratio of events in the two detectors, as the neutrino flux varies as $1/r^2$ to a calculable approximation. This will allow sensitive tests of oscillations for both $\nu_e$ and $\bar \nu_e$ appearance and $\nu_\mu$ and $\bar \nu_\mu$ disappearance. Furthermore, a comparison between oscillations in neutrino mode and antineutrino mode will allow a sensitive search for CP and CPT violation in the lepton sector at short baseline ($\Delta m^2 > 0.1$ eV$^2$).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗