Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPACE LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Delving into the depths of NGC 3783 with XRISM

The 2024 X-ray/UV observation campaign of NGC 3783, led by XRISM, revealed the launch of an ultrafast outflow (UFO) with a radial velocity of 0.19c (57 000 km s −1 ). This event is synchronized with the sharp decay, within less than half a day, of a prominent soft X-ray/UV flare. Accounting for the look-elsewhere effect, the XRISM Resolve data alone indicate a low probability of 2 × 10 −5 that this UFO detection is due to random chance. The UFO features narrow H-like and He-like Fe lines with a velocity dispersion of ∼1000 km s −1 , suggesting that it originates from a dense clump. Beyond this primary detection, there are hints of weaker outflow signatures throughout the rise and fall phases of the soft flare. Their velocities increase from 0.05c to 0.3c over approximately three days, and they may be associated with a larger stream in which the clump is embedded. The radiation pressure is insufficient to drive the acceleration of this rapidly evolving outflow. The observed evolution of the outflow kinematics instead closely resembles that of solar coronal mass ejections, implying magnetic driving and, conceivably, reconnection near the accretion disk as the likely mechanisms behind both the UFO launch and the associated soft flare.

Astronomy and AstroPhysics↗

Understanding cold electron impact on parallel-propagating whistler chorus waves via moment-based quasilinear theory

Earth's magnetosphere hosts a wide range of collisionless particle populations that interact through various wave-particle processes. Among these, cold electrons, with energies below 100 eV, often dominate the plasma density but remain poorly characterized due to measurement challenges such as spacecraft charging and photoelectron contamination. Understanding the contribution of these cold populations to wave–particle interaction is of significant interest. Recent kinetic simulations identified a secondary drift-driven instability, in which parallel-propagating whistler-mode chorus waves excite oblique electrostatic whistler waves near the resonance cone and Bernstein-mode turbulence. These secondary modes enable a new channel of energy transfer from the parallel-propagating whistler wave to the cold electrons. In this work, we develop a moment-based quasilinear theory of the secondary instabilities to quantify such energy exchange. Our results show that these secondary instabilities persist for a wide range of parameters and, in many cases, lead to nearly complete damping of the primary wave. Such secondary instability might limit the amplitude of parallel-propagating whistler waves in Earth's magnetosphere and might explain why high-amplitude oblique whistler or electron Bernstein waves are rarely observed simultaneously with high-amplitude field-aligned whistler waves in the inner magnetosphere.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Warm-phase microphysical evolution in large-eddy simulations of tropical cumulus congestus: evaluating drop size distribution evolution using polarimetry retrievals, in situ measurements, and a thermal-based framework

Owing to uncertainties in convective microphysics processes, improving parameterizations in Earth system models (ESMs) can benefit from observationally constrained cases suitable for scaling between cloud-resolving models and ESMs. We propose a benchmark large-eddy simulation (LES) cumulus congestus case study from the NASA Cloud, Aerosol, and Monsoon Processes Philippines Experiment (CAMP 2 Ex) for evaluating and improving ESMs in single-column model (SCM) mode. We seek observational constraints using novel polarimetric retrievals and in situ cloud microphysics measurements. Simulations using bulk and bin microphysics initialized with observed aerosol profiles are compared to cloud-top retrievals of cloud droplet effective radius (R eff ), effective variance (ν eff ), and number concentration (N d ) from the airborne Research Scanning Polarimeter (RSP). Both schemes reproduce characteristics of cloud-top N d and R eff that increase and decrease with altitude, respectively. Cloud-top N d is low-biased relative to RSP retrievals in both schemes, potentially due to limitations in both simulations and retrieval assumptions. Cloud-top R eff is low-biased in the bulk scheme but reasonably reproduced by the bin scheme. Profiles of N d and R eff are sensitive to the collision–coalescence process and the vertical variation in aerosol size distribution. Comparison of simulated and in situ droplet size distributions (DSDs) shows that, to first order, integrated moments are always sensitive to sizes < ~ 30 µm and can also be sensitive to larger sizes if the DSDs are sufficiently broad, with implications for the assumed maximum observed size retrieved by the RSP. The bin scheme captures the observed extended tail of the DSD, while the bulk scheme is unable to due to parametric constraints. Differences in expected relationships between in situ measurements of cloud cores and cloud-top retrievals by RSP demonstrate difficulty in constraining well the case presented herein. Finally, a thermal-tracking framework demonstrates that the dilution of N d throughout a thermal's lifetime is heavily determined by collision–coalescence and the height-varying aerosol distribution and that, in the absence of these, the impact of entrainment on diluting N d is largely offset by secondary activation. Implications for evaluating warm-phase convective microphysics schemes in ESMs and translating results for use on global, space-based polarimetry platforms are discussed.

Stanford, McKenna Wallace [Columbia Univ., New Yor↗

Energy-Efficiency & Water Institute Research Facility, Purdue University, (IN)

The renovation of the Schneider Avenue Building to construct two research laboratories within the building is complete. The research laboratories are for the Purdue Calumet Water Institute and the Energy Efficiency and Reliability Center. The Water Institute occupies approximately 1000+ SF of research space plus supporting offices. The Energy-Efficiency Center occupies approximately 1000+ SF that houses the research space. The labs will enhance the Water & Energy Institute’s research capabilities necessary to tackle these issues through the development of practical approaches critical to local government and industry. The addition of these research laboratories to the Purdue University Calumet campus is in both direct support of the University’s Strategic Plan as well as the 2008 Campus Master Plan that identifies a 20% shortage of research space.

54 ENVIRONMENTAL SCIENCES↗

Delving into the depths of NGC 3783 with XRISM

We present our study of the X-Ray Imaging and Spectroscopy Mission (XRISM) observation of the Seyfert-1 galaxy NGC 3783. XRISM’s Resolve microcalorimeter has enabled, for the first time, a detailed characterization of the highly ionized outflows in this active galactic nucleus. Our analysis constrains their outflow and turbulent velocities, along with their ionization parameter (ξ) and column density (N H ). The high-resolution Resolve spectrum reveals a distinct series of Fe absorption lines between 6.4 and 7.8 keV, ranging from Fe XVIII to Fe XXVI. At lower energies (1.8−3.3 keV), absorption features from Si, S, and Ar are also detected. Our spectroscopy and photoionization modeling of the time-averaged Resolve spectrum uncovers six outflow components, five of which exhibit relatively narrow absorption lines with outflow velocities ranging from 560 to 1170 km s −1 . In addition, a broad absorption feature is detected, which is consistent with Fe XXVI outflowing at 14 300 km s −1 (0.05 c). The kinetic luminosity of this component is 0.8−3% of the bolometric luminosity. Our analysis of the Resolve spectrum shows that more highly ionized absorption lines are intrinsically broader than those of lower-ionization species, indicating that the turbulent velocity of the six outflow components (ranging from 0 to 3500 km s −1 ) increases with ξ. Furthermore, we find that the column density (N H ) of the outflows generally declines with the ionization parameter up to log ξ = 3.2 but rises beyond this point, suggesting a complex ionization structure. The absorption profile of the Fe XXV resonance line is intriguingly similar to UV absorption lines (Lyα and C IV) observed by the Hubble Space Telescope, from which we infer that the outflows are clumpy in nature. Our XRISM/Resolve results from lower- and higher-ionization regimes support a “hybrid wind” scenario in which the observed outflows have multiple origins and driving mechanisms. We explore various interpretations of our findings within active galactic nucleus wind models.

X-rays: galaxies↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Nanoscale Effects on Oxygen Ion Conductance in Oxide Electrolytes

This chapter describes the results from a project that aimed to develop an understanding of oxygen ionic transport processes in oxide nanostructured materials that may enable the design of new types of electrolyte materials for electrochemical device applications with enhanced ionic conductivity that function well at low temperatures. Increased ionic transport at low temperatures would simply allow the use of a wide range of lower-cost materials for electrochemical devices. Interface-controlled nucleation and growth of two- and three-dimensional, nanostructured materials show unique physical, chemical and electronic properties that are different from bulk materials due to quantum confinement and other effects occurring at the nanoscale. Atomic and ionic transport, which is crucial for many technological applications including catalysis and fuel-cell technology, is also expected to be enhanced in nanostructured materials due to effects related to size, electronic structure, space charge and multiple interface pathways. We have investigated the fundamental scientific issues associated with oxygen ionic transport properties of multilayer, single- and poly-crystalline nano-oxide film structures on suitable substrates. We have taken advantage of our ability to grow and characterize single-crystal, pure and doped multilayer, nanoscale materials, using state-of-the-art capabilities at the Environmental Molecular Sciences Laboratory (EMSL). Detail description of the results from the investigations of thin films with nanodomains, with interfaces parallel to the substrate surfaces and with interfaces perpendicular to the substrate surfaces is discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron density distribution and crystal structure of 27R-AlON, Al{sub 9}O{sub 3}N{sub 7}

The crystal structure of Al{sub 9}O{sub 3}N{sub 7} was characterized by laboratory X-ray powder diffraction (CuKα{sub 1}). The title compound is trigonal with space group R3-bar m (centrosymmetric). The hexagonal unit-cell dimensions (Z=3) are a=0.30656(2) nm, c=7.2008(3) nm and V=0.58605(5) nm{sup 3}. The initial structural model was derived by the powder charge-flipping method and subsequently refined by the Rietveld method. The final structural model showed the positional disordering of two of the five types of Al sites. The maximum-entropy method-based pattern fitting method was used to confirm the validity of the split-atom model, in which conventional structure bias caused by assuming intensity partitioning was minimized. The disordered crystal structure was successfully described by overlapping five types of domains with ordered atom arrangements. The distribution of atomic positions in one of the five types of domains can be achieved in the space group R3{sup ¯}m. The atom arrangements in the four other domains are noncentrosymmetric with the space group R3m. Two of the four types of domains are related by a pseudo-symmetry inversion, and the two remaining domains also have each other the inversion pseudo-symmetry. The very similar domain structure has been also reported for 21R-AlON (Al{sub 7}O{sub 3}N{sub 5}) in our previous study. - Graphical abstract: A bird’s eye view of electron densities up to 50% (0.074 nm{sup −3}) of the maximum on the plane parallel to (110) with the corresponding atomic arrangements of Al{sub 9}O{sub 3}N{sub 7}. Highlights: • Crystal structure of Al{sub 9}O{sub 3}N{sub 7} is determined by laboratory X-ray powder diffraction. • The atom arrangements are represented by the split-atom model. • The maximum-entropy method-based pattern fitting method is used to confirm the validity of the model. • The disordered structure is described by overlapping five types of domains with ordered atom arrangements.

36 MATERIALS SCIENCE↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

From Theory to Large-Scale Simulations, or Living Without “The Paradox of Choice”

Navigating the challenges we face at work and in life is often difficult, and can even make us question our past decisions. This dilemma is even worse nowadays because of the many options available to us, leaving us not enough time to explore them all: the paradox of choice. My life experience offers another perspective on how to make choices; wherein I had to rely more on serendipity, coincidence, and embracing risks. This paper presents a brief description of my career path in space science—from a small village in the countryside to one of the top science Laboratories in the world—and lessons learned through the process of becoming a more resilient scientist. I came to the United States from Bulgaria about 30 years ago, seeking a better education and job opportunities. Navigating a career of research scientist, not only did I find jobs that motivated me every day, I also met amazing people to work with along the way. As a woman in science, I hope my story can inspire and attract young researchers (girls and boys alike) to our community, helping to grow and diversify the next generation of space scientists.

99 GENERAL AND MISCELLANEOUS↗

Measurement and modeling of pulsed microchannel plate operation (invited)

Microchannel plates (MCPs) are a standard detector for fast-framing x-ray imaging and spectroscopy of high-temperature plasmas. The MCP is coated with conductive striplines that carry short duration voltage pulses to control the timing and amplitude of the signal gain. This gain depends on the voltage to a large exponent so that small reflections or impedance losses along the striplines can have a significant impact on the position-dependent amplitude and pulse width of the gain. Understanding the pulsed gain response therefore requires careful measurements of the position- and time-dependent surface voltage coupled with detailed modeling of the resulting electron cascade. We present measurements and modeling of the time- and space-dependent gain response of MCP detectors designed for use at Sandia National Laboratories' Z facility. The pulsed gain response is understood through measurements using a high impedence probe to determine the voltage pulse propagating along the stripline surface. Coupling the surface voltage measurements with Monte Carlo calculations of the electron cascade in the MCP provides a prediction of the time- and position-dependent gain that agrees with measurements made on a subpicosecond UV laser source to within the 25% uncertainty in the simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity Reach of the Neutron EDM Experiment: The Electric Field Strength

The search for an electric dipole moment of the neutron tests physics beyond the Standard Model such as new sources of CP-violation and Supersymmetry. The nEDM experiment aims to improve the sensitivity on the current limit of the electric dipole moment of the neutron to <10{sup -27} e{center_dot}cm. The experiment will use a flux of Ultra Cold Neutrons (UCNs) produced and stored in a bath of superfluid He-II. A change in precession frequency is expected for a non-zero EDM when an electric field is applied parallel and antiparallel to a magnetic field across the neutron storage cell. A dominant parameter in terms of reducing the statistical uncertainty of this measurement is the strength of the applied electric field. An experiment to measure if superfluid He-II can sustain up to 50 kV/cm for a volume and electrode spacings comparable to the nEDM experiment has been constructed at Los Alamos National Laboratory. It consists in a large-area parallel plate capacitor immersed in a 200 liter central volume inside a suitable cryostat that in turn is connected to a dilution refrigerator unit. A description of test runs and the status of the experiment is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermophysical Properties of a Uranium Nitride–Molybdenum-Tungsten Composite Fuel for Nuclear Thermal Propulsion

The thermal conductivity of a ceramic-metal composite consisting of 60 vol % uranium nitride incorporated into a molybdenum-tungsten matrix has been measured up to a temperature of 1200°C. Compositing nuclear fuel with refractory materials is considered a viable way to improve the thermal and mechanical properties of fuels, and more recently, has been investigated as a way to improve hydrogen compatibility in a nuclear thermal propulsion rocket reactor. Here, we demonstrate that high-density composites can be produced from direct current sintering and that the resulting thermal conductivity is improved compared to the pure.

33 ADVANCED PROPULSION SYSTEMS↗

LINKING TESTS OF GRAVITY ON ALL SCALES: FROM THE STRONG-FIELD REGIME TO COSMOLOGY

The current effort to test general relativity (GR) employs multiple disparate formalisms for different observables, obscuring the relations between laboratory, astrophysical, and cosmological constraints. To remedy this situation, we develop a parameter space for comparing tests of gravity on all scales in the universe. In particular, we present new methods for linking cosmological large-scale structure, the cosmic microwave background, and gravitational waves with classic PPN tests of gravity. Diagrams of this gravitational parameter space reveal a noticeable untested regime. The untested window, which separates small-scale systems from the troubled cosmological regime, could potentially hide the onset of corrections to GR.

79 ASTRONOMY AND ASTROPHYSICS↗

Order-by-order uncertainties of nucleon-nucleon Wolfenstein amplitudes in chiral effective field theory

Quantum mechanical invariance principles dictate the most general operator structure that can be present in the nucleon-nucleon (NN) interaction. Five independent operators appear in the on-shell NN amplitude together with five corresponding coefficient functions. The usual choice for these coefficient functions is known as the NN Wolfenstein amplitudes. We analyze the order-by-order convergence of each of the five NN Wolfenstein amplitudes predicted by a semilocal coordinate space potential implementation of chiral effective field theory (𝜒⁢EFT). We do this at laboratory kinetic energies between 25 and 200 MeV for both neutron-proton and proton-proton scattering. Our analysis uses the Gaussian-process methods developed by the BUQEYE Collaboration to describe the contributions of each 𝜒⁢EFT order, and so yields truncation uncertainties for each Wolfenstein amplitude that are correlated across scattering angles. We combine information on the size of different orders in the EFT to infer the 𝜒⁢EFT breakdown scale for each amplitude, finding, on average, Λ 𝑏 between 750 and 800 MeV. Furthermore, with this choice of Λ 𝑏 , the EFT truncation uncertainties cover both higher-order results and empirical Wolfenstein amplitudes well for all orders other than the leading order.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hardness assurance for proton direct ionization-induced SEEs using a high-energy proton beam

The low-energy proton energy spectra of all shielded space environments have the same shape. This shape is easily reproduced in the laboratory by degrading a high-energy proton beam, producing a high-fidelity test environment. We use this test environment to dramatically simplify rate prediction for proton direct ionization effects, allowing the work to be done at high-energy proton facilities, on encapsulated parts, without knowledge of the IC design, and with little or no computer simulations required. Proton direct ionization (PDI) is predicted to significantly contribute to the total error rate under the conditions investigated. Scaling effects are discussed using data from 65-nm, 45-nm, and 32-nm SOI SRAMs. These data also show that grazing-angle protons will dominate the PDI-induced error rate due to their higher effective LET, so PDI hardness assurance methods must account for angular effects to be conservative. As a result, we show that this angular dependence can be exploited to quickly assess whether an IC is susceptible to PDI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large-scale shell-model calculations for even-odd {sup 61-65}Fe isotopes

Large-scale shell-model calculations have been performed to calculate the negative-parity states of even-odd {sup 61-65}Fe isotopes. The results are compared with the recent experimental data reported at Legnaro National Laboratories and also with earlier calculations with fpg interaction in a truncated configuration space. It is observed that negative parity states of {sup 61}Fe can be well reproduced with GXPF1A interaction in full fp space without truncation. For {sup 63}Fe the correct ordering of levels is not reproduced. The structure of the wave function for the ground state and first excited state suggests that the ordering of the single-particle energy levels gets modified due to monopole correction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗