Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Tabletop Testing for EV Charging Ecosystem PKI (Project T34PKI Final Report)

To test the communications and cybersecurity functionality, Electric Vehicle and charging station vendors have had to ship their products to in-person testing events. This is cumbersome, expensive, inefficient, and an impediment to rapid time-to-deployment. In this project Sandia used COTS hardware and Open-Source Software to develop and demonstrate a more agile, productive approach: testing low-voltage controllers independently from high-voltage power delivery sub-systems. This approach allows communications controllers to be transported easily (e.g. shipped at low cost, checked as airline baggage); set up on a table-top (“bench testing”); and use ordinary 120 VAC outlets to conduct agile testing. Table-top platforms become end nodes that can connect to laboratory and cloud-based servers to test communications and cybersecurity, specifically Public Key Infrastructure (PKI) functionality and interoperability, separately from EV battery charging (power/energy transfer) functionality.

33 ADVANCED PROPULSION SYSTEMS↗

A Unit Testing Framework for Scientific Legacy Code

Large-scale scientific applications play important roles in supporting research. However, it is often very expensive and time-consuming to make changes to, maintain and evolve the scientific code due to its complexity and poor programming skills of researchers. Therefore, in order to visualize scientific code architecture to optimize software design, understand undocumented source code, and analyze software flow and functionality, we first introduce a unit testing framework (UTF). Then, because such infrastructure's performance is very crucial in practical use since the scientific legacy applications simulate instances in a long period of time, we improve the UTF by applying Message Passing based Parallelization and parallel I/O operations. Furthermore, due to the scientific code has enormous state data and the I/O capacity on the server is limited, we apply in situ data analysis method to encounter fewer resource limitations, and adopt signal processing to greatly reduce data transfer. Last, we demonstrated the correctness and high-efficiency of our framework for legacy Earth model on Titan supercomputer.

97 MATHEMATICS AND COMPUTING↗

WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary and secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.

60 APPLIED LIFE SCIENCES↗

Community-Driven Methods for Open and Reproducible Software Tools for Analyzing Datasets from Atom Probe Microscopy

Atom probe tomography, and related methods, probe the three-dimensional architecture of a material. The software tools that microscopists use, and how these tools are connected into workflows, makes a substantial contribution to the accuracy and precision of such a material characterization experiment. Typically, we adapt methods from other communities like mathematics, data science, computational geometry, artificial intelligence, or scientific computing. We also realize that improving on research data management is a challenge when it comes to align with the FAIR data stewardship principles. Faced with this global challenge, we are convinced that collaborating is useful. Here, we report the results and challenges with an inter-laboratory call for developing test cases for several types of atom probe software tools. The results support why defining detailed recipes of software workflows and sharing these recipes is necessary and rewarding: Open source tools and (meta)data exchange can help to make our day-to-day data processing tasks become more efficient, the training of new users and knowledge transfer become easier, and assist us with automated quantification of uncertainties to gain access to substantiated results.

36 MATERIALS SCIENCE↗

NEW SOFTWARE QUALITY ASSURANCE GUIDANCE FOR CONSEQUENCE ASSESSMENT MODELS

The U.S. Department of Energy (DOE) Subcommittee for Consequence Assessment and Protective Action (SCAPA) is developing new software quality assurance (SQA) guidance for consequence assessment models and related emergency management software. In 2004, a DOE Order and Guide were issued to provide comprehensive SQA guidelines for safety software used at nuclear facilities. Some consequence assessment models need to meet these guidelines, but others do not because they support less critical “safety-related’ applications for which DOE has not issued SQA guidelines. The SCAPA SQA guidance is based on the DOE SQA Guide for safety software but the SCAPA guidance applies a more graded approach. The SCAPA guidance focuses on enhancing the quality and reliability of software through appropriate SQA planning, software design and implementation documentation, verification and validation testing, and configuration management. In putting together this guidance, SCAPA is seeking to support the development of effective SQA programs without stymieing technical innovation. This SQA guidance also will provide a framework to supplement and integrate the hodgepodge of project- program-, company-, or site-based SQA expectations that may already exist for some safety-related applications.

consequence assessment modeling↗

Validating automated resonance evaluation with synthetic data

The integrity and precision of nuclear data are crucial for a broad spectrum of applications, from national security and nuclear reactor design to medical diagnostics, where the associated uncertainties can significantly impact outcomes. A substantial portion of uncertainty in nuclear data originates from the subjective biases in the evaluation process, a crucial phase in the nuclear data production pipeline. Recent advancements indicate that automation of certain routines can mitigate these biases, thereby standardizing the evaluation process and enhancing reproducibility. This research aims to provide a methodology, framework, and metrics for the validation of automated nuclear data evaluation software leveraging high-quality synthetic data that closely mimic real experimental observables. An introduced error metric provides a scale and intuitive measure of the evaluation quality by quantifying the estimate’s accuracy and performance across the specified energy range. Synthetic data provides access to experimental observables and underlying resonance parameters, enabling comparison of different evaluations. The methodology is demonstrated using Ta-181 isotope data in the resolved resonance region. The Automated Resonance Identification Subroutine (ARIS), which operates without prior resonance information, was used to test and showcase the framework’s capabilities utilizing the proposed error metrics. The results demonstrate the effectiveness of the proposed approach and framework for optimizing software parameters and testing hypotheses through “what-if” controlled experiments, such as modifying assumptions about experimental conditions or average resonance parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Guideline 36 Conformance Test v2.0

ASHRAE Guideline 36 provides guidance for how typical commercial building HVAC systems should be controlled to reduce energy costs and improve the indoor environmental quality for occupants. An industry-led effort is developing test scripts for how control manufacturers can test that the control logic in their control products follows Guideline 36. This software intends to support that effort in two ways. First, by providing a testbed for control manufacturers to run the test scripts against their own control products and compare their generated results to the expected results provided by the test scripts. Second, by providing a testbed that can be used during the development of test scripts to rapidly and repeatably verify they exercise Guideline 36 logic as desired and generate accurate expected results that control products can be compared to. An initial version of the software has already been developed and released open-source by a previous CEC-funded project that implemented the first use case (https://github.com/LBNL-ETA/guideline36_conformance_test/blob/master/LICENSE.txt), while this software disclosure will add the functionality of the second use case, as well as update the software where needed, all open-source. We intend to extend and contribute to the existing open-source software repository.

Blum, David [Lawrence Berkeley National Laboratory↗

Interpretation of production tests in geothermal wells with T2Well-EWASG

In the geothermal sector, being able to simulate production tests by combining surface and downhole measurements can be extremely useful, improving data interpretation and reducing the impact of unavailable field data. This is possible with T2Well, a coupled wellbore-reservoir simulator. In this study, we plugged the EWASG equation of state for high enthalpy geothermal reservoirs into T2Well and extended the function to analytically compute the heat exchange between wellbore and formation at the short times. Changes to the analytical heat exchange function were verified by comparison with wellbore-formation heat exchange numerically simulated. T2Well-EWASG was validated by reproducing the flowing pressure and temperature logs taken from literature, and by using the software for the interpretation of a short production test. Lastly, simulation results indicate that T2Well-EWASG can be effectively used to improve the interpretation of production tests performed in geothermal wells.

58 GEOSCIENCES↗

Exploratory Investigation of Disengagements and Crashes in Autonomous Vehicles Under Mixed Traffic: An Endogenous Switching Regime Framework

Autonomous Vehicles (AVs) have a large potential to improve traffic safety but also pose some critical challenges. While AVs may help reduce crashes caused by human error, they still may experience failures of technologies and sensing, as well as decision-making errors in a mixed traffic environment. A disengagement refers to an AV transitioning control from autonomous systems to the trained test driver. The safety critical nature of disengagements makes it imperative to analyze disengagements and crashes together. In this study, we analyze both crashes and disengagements from real-world AV driving in California to fill the knowledge gap regarding the relationship between disengagements and crashes in a mixed traffic environment. A nested logit model was calibrated using three different outcomes: (1) disengagement with a crash, (2) disengagement with no crash, and (3) no disengagement with a crash. Furthermore, endogenous switching regime models were also calibrated to draw distinctions between the relation of disengagements and crashes while accounting for endogeneity effects. The results show that factors related to AV systems (such as software failures) and other roadway participants increase the propensity of a disengagement without a crash. Furthermore, AVs were observed to disengage less often as the technology matured over time. Marginal effects revealed an 8% decrease. The results thus suggest that disengagements are a part of AVs' safe performance and disengagement alerts may need to be triggered in order to avoid certain failures with current technology.

42 ENGINEERING↗

SU-F-T-139: Meeting the Challenges of Quality Control in the TOPAS Monte Carlo Simulation Toolkit for Proton Therapy

Purpose: Monte Carlo particle transport simulation (MC) codes have become important tools in proton therapy and biology, both for research and practice. TOPAS is an MC toolkit serving users worldwide (213 licensed users at 95 institutions in 21 countries). It provides unprecedented ease in 4D placement of geometry components, beam sources and scoring through its user-friendly and reproducible parameter file interface. Quality control (QC) of stochastic simulation software is inherently difficult, and the versatility of TOPAS introduces additional challenges. But QC is vital as the TOPAS development team implements new features, addresses user feedback and reacts to upgrades of underlying software (i.e. Geant4). Methods: Whenever code is committed to our repository, over 50 separate module tests are automatically triggered via a continuous integration service. They check that the various module options execute successfully and that their results are statistically consistent with previous reference values. Prior to each software release, longer end-to-end tests automatically validate TOPAS against experimental data and a TOPAS benchmark. These include simulating multiple properties of spread-out Bragg peaks, validating nuclear models, and searching for differences in patient simulations. Results: Continuous integration has proven effective in catching regressions at the time they are introduced, particularly when implementing new features that involve refactoring code (e.g. multithreading and ntuple output). Code coverage statistics highlight untested portions of code and guide development of new tests. The various end-to-end tests demonstrate that TOPAS accurately describes the physics of proton therapy within clinical tolerances. Conclusion: The TOPAS QC strategy of frequent short tests and pre-release long tests has led to a more reliable tool. However, the versatility of TOPAS makes it difficult to predict how users might combine different modules, and so QC ultimately remains a partnership between the developer and the user. This work was funded by National Cancer Institute grant R01 CA 140735.

60 APPLIED LIFE SCIENCES↗

Improving superficial target delineation in radiation therapy with endoscopic tracking and registration

Purpose: Target delineation within volumetric imaging is a critical step in the planning process of intensity modulated radiation therapy. In endoluminal cancers, endoscopy often reveals superficial areas of visible disease beyond what is seen on volumetric imaging. Quantitatively relating these findings to the volumetric imaging is prone to human error during the recall and contouring of the target. We have developed a method to improve target delineation in the radiation therapy planning process by quantitatively registering endoscopic findings contours traced on endoscopic images to volumetric imaging. Methods: Using electromagnetic sensors embedded in an endoscope, 2D endoscopic images were registered to computed tomography (CT) volumetric images by tracking the position and orientation of the endoscope relative to a CT image set. Regions-of-interest (ROI) in the 2D endoscopic view were delineated. A mesh created within the boundary of the ROI was projected onto the 3D image data, registering the ROI with the volumetric image. This 3D ROI was exported to clinical radiation treatment planning software. The precision and accuracy of the procedure was tested on two solid phantoms with superficial markings visible on both endoscopy and CT images. The first phantom was T-shaped tube with X-marks etched on the interior. The second phantom was an anatomically correct skull phantom with a phantom superficial lesion placed on the pharyngeal surface. Markings were contoured on the endoscope images and compared with contours delineated in the treatment planning system based on the CT images. Clinical feasibility was tested on three patients with early stage glottic cancer. Image-based rendering using manually identified landmarks was used to improve the registration. Results: Using the T-shaped phantom with X-markings, the 2D to 3D registration accuracy was 1.5-3.5 mm, depending on the endoscope position relative to the markings. Intraobserver standard variation was 0.5 mm. Rotational accuracy was within 2 deg. Using the skull phantom, registration accuracy was assessed by calculating the average surface minimum distance between the endoscopy and treatment planning contours. The average surface distance was 0.92 mm with 93% of all points in the 2D-endoscopy ROI within 1.5 mm of any point within the ROI contoured in the treatment planning software. This accuracy is limited by the CT imaging resolution and the electromagnetic (EM) sensor accuracy. The clinical testing demonstrated that endoscopic contouring is feasible. With registration based on em tracking only, accuracy was 5.6-8.4 mm. Image-based registration reduced this error to less than 3.5 mm and enabled endoscopic contouring in all cases. Conclusions: Registration of contours generated on 2D endoscopic images to 3D planning space is feasible, with accuracy smaller than typical set-up margins. Used in addition to standard 3D contouring methods in radiation planning, the technology may improve gross tumour volume (GTV) delineation for superficial tumors in luminal sites that are only visible in endoscopy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-169: A Periodic Quality Assurance Program for a Spot-Scanning Proton Treatment Facility

Purpose: To develop daily and monthly quality assurance (QA) programs in support of a new spot-scanning proton treatment facility using a combination of commercial and custom equipment and software. Emphasis was placed on efficiency and evaluation of key quality parameters. Methods: The daily QA program was developed to test output, spot size and position, proton beam energy, and image guidance using the Sun Nuclear Corporation rf-DQA™3 device and Atlas QA software. The program utilizes standard Atlas linear accelerator tests repurposed for proton measurements and a custom jig for indexing the device to the treatment couch. The monthly QA program was designed to test mechanical performance, image quality, radiation quality, isocenter coincidence, and safety features. Many of these tests are similar to linear accelerator QA counterparts, but many require customized test design and equipment. Coincidence of imaging, laser marker, mechanical, and radiation isocenters, for instance, is verified using a custom film-based device devised and manufactured at our facility. Proton spot size and position as a function of energy are verified using a custom spot pattern incident on film and analysis software developed in-house. More details concerning the equipment and software developed for monthly QA are included in the supporting document. Thresholds for daily and monthly tests were established via perturbation analysis, early experience, and/or proton system specifications and associated acceptance test results. Results: The periodic QA program described here has been in effect for approximately 9 months and has proven efficient and sensitive to sub-clinical variations in treatment delivery characteristics. Conclusion: Tools and professional guidelines for periodic proton system QA are not as well developed as their photon and electron counterparts. The program described here efficiently evaluates key quality parameters and, while specific to the needs of our facility, could be readily adapted to other proton centers.

60 APPLIED LIFE SCIENCES↗

REBUS-PC v1.5 Verification Test Summary

Motivated in part by its usage for analysis of the University of Missouri Research Reactor (MURR), the verification of the REBUS-PC software for θ-R-Z geometries is discussed and displayed in this manuscript. Of particular importance is to show that the eigenvalue, flux, power, and burnup outputs of the software given a user problem is correct. REBUS-PC contains many features and MURR only makes use of some of those aspects. As an example, the use of region specific cross section sets, interpolation of the cross section data with respect to burnup, and automatic movement of control rods during the fuel cycle is discussed and displayed. To demonstrate the accuracy, 22 verification tests based upon 7 physical geometries are discussed. Geometry descriptions are provided in Section 2 and the REBUS-PC results for each verification test are discussed in Section 3. These verification tests consist of both analytic problems with known solutions and a more complicated input consistent with usage of REBUS-PC on the MURR reactor itself called STRZ. In this verification test summary report, the REBUS-PC software is repeatedly demonstrated to reproduce, or closely match, the eigenvalue, flux, and power distributions from analytic test problem solutions, demonstrating that the implemented finite difference approximation in θ-R-Z is working as intended. Several additional REBUS-PC features are tested, such as control rod movement by detailed comparisons of the results against reference solutions obtained using an auxiliary implemented MatLab program. As expected, the REBUS-PC software produces results that are 100% consistent with the stated capabilities and thus the verification exercise is completed. These verification tests should be executed with each re-compilation of the REBUS-PC source and after any source code changes. All output results from any such new work should be rigorously compared against the stored output of the 22 verification tests cited in this report that forms the basis of the verification process.

97 MATHEMATICS AND COMPUTING↗

Demonstration of Datacenter Automation Software and Hardware (DASH) at the California Franchise Tax Board

Control software and wireless sensors designed for closed-loop, monitoring and control of IT equipment's inlet air temperatures in datacenters were evaluated and tested while other datacenter cooling best practices were implemented. The controls software and hardware along with each best practice were installed sequentially and evaluated using a measurement and verification procedure between each measure. The results show that the overall project eliminates 475,239 kWh per year, which is 21.3percent of the baseline energy consumption of the data center. The total project, including the best practices will save $42,772 per year and cost $134,057 yielding a simple payback of 3.1 years. However, the control system alone eliminates 59.6percent of the baseline energy used to move air in the datacenter and 13.6percent of the baseline cooling energy, which is 15.2percent of the baseline energy consumption (see Project Approach, Task 1, below, for additional information) while keeping temperatures substantially within the limits recommended by ASHRAE. Savings attributed to the control system are $30,564 per year with a cost $56,824 for a simple payback of 1.9 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MPACT Fast Neutron Multiplicity System Prototype Development

This document serves as both an FY2103 End-of-Year and End-of-Project report on efforts that resulted in the design of a prototype fast neutron multiplicity counter leveraged upon the findings of previous project efforts. The prototype design includes 32 liquid scintillator detectors with cubic volumes 7.62 cm in dimension configured into 4 stacked rings of 8 detectors. Detector signal collection for the system is handled with a pair of Struck Innovative Systeme 16-channel digitizers controlled by in-house developed software with built-in multiplicity analysis algorithms. Initial testing and familiarization of the currently obtained prototype components is underway, however full prototype construction is required for further optimization. Monte Carlo models of the prototype system were performed to estimate die-away and efficiency values. Analysis of these models resulted in the development of a software package capable of determining the effects of nearest-neighbor rejection methods for elimination of detector cross talk. A parameter study was performed using previously developed analytical methods for the estimation of assay mass variance for use as a figure-of-merit for system performance. A software package was developed to automate these calculations and ensure accuracy. The results of the parameter study show that the prototype fast neutron multiplicity counter design is very nearly optimized under the restraints of the parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Supercritical carbon dioxide tubular flow under temporally varying thermal boundary condition

During transient operation of fusion power plants the amount of thermal energy transferred from plasma to surrounding blanket modules will be varied over time, and will affect behavior of the working fluid inside the blanket and power conversion system where the coolant is in a supercritical state. Transient behavior of the power is in pulsed state in tokamak. The Optimized Supercritical Cycle Operation (OSCO) loop is constructed to investigate the thermohydraulic characteristics of the supercritical fluid under temporally varying thermal boundary condition. In this study the tube outer wall temperature data are measured for abrupt change in thermal power as a preliminary power transient test. The OSCO test conditions are selected to include the erratic behavior of the supercritical fluid under pseudo-critical condition during transient. In order to incorporate the delayed response of utilized thermocouples, a time constant is applied to adjust the obtained results. Along with the experimental study, computational fluid dynamic software is used to perform detailed analysis over the test section geometry. The preliminary test results are presented for comparison against the available correlations from the literature. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Liquid Cooling in Data Centers

Semiconductor manufacturers have aggressively attacked the problem of escalating microprocessor power consumption levels. Today, server manufacturers can purchase microprocessors that currently have power consumption levels capped at 100W maximum. However, total server power levels continue to increase, with the increase in power consumption coming from the supportin chipsets, memory, and other components. In turn, full rack heat loads are very aggressivley climbing as well, and this is making it increasingly difficult and cost-prohibitive for facility owners to cool these high power racks. As a result, facilities owners are turning to alternative, and more energy efficient, cooling solutions that deploy liquids in one form or another. The paper discusses the advent of the adoption of liquid-cooling in high performance computing centers. An overview of the following competing rack-based, liquid-cooling, technologies is provided: in-row, above rack, refrigerated/enclosed rack, rear door heat exchanger, and device-level (i.e., chip-level). Preparation for a liquid-cooled data center, retroft and greenfield (new), is discussed, with a focus on the key issues that are common to all liquid-cooling technologies that depend upon the delivery of water to the rack (or in some deployments, a Coolant Distribution Unit). The paper then discusses, in some detail, the actual implementation and deployment of a liquid device-level cooled (spray cooled) supercomputer at the Pacific Northwest National Laboratory. Initial results from a successful 30 day compliance test show excellent hardware stability, operating system (OS) and software stack stability, application stability and performance, and an availability level that exceeded expectations at 99.94%. The liquid-cooled supercomputer achieved a peak performance of 9.287 TeraFlops, which placed it at number 101 in the June 2007 Top500 fastest supercomputers worldwide. Long-term performance and energy efficiency testing is currently underway, and detailed results will be reported in upcoming publications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FASPAX ASIC revision 1.b first articles testing and support

Fermi National Accelerator Laboratory (Fermilab) and Field Viewers Ltd. Inc. (FV) will work together for a period of two weeks to bring up the FASPAX_V1.0b. During this period, Fermilab will help FV come up to speed with the ASIC functionality testing and train in the usage of the FASPAX test setup at Fermilab that uses the NIPXIe architecture with FleXRIO modules. This setup will be initially used for testing of chips to ensure the basic functionality and design parameters. The NIPXIe setup was developed by the Fermilab team, but it is has not yet been verified to be capable of fully testing the FASPAX_V1.0 chip. Fermilab will offer the developed software and hardware to FV for the on-site use at Fermilab. No guarantee is given by Fermilab for the setup to be able to fully cover the scope of the necessary tests. FV will be responsible for using and modifying of the setup to achieve the DOE-BES Phase-I targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗