Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

A consistent-mode indicator for the eigensystem realization algorithm

A new method is described for assessing the consistency of structural modal parameters identified with the Eigensystem Realization Algorithm. Identification results show varying consistency in practice due to many sources including high modal density, nonlinearity, and inadequate excitation. Consistency is considered to be a reliable indicator of accuracy. The new method is the culmination of many years of experience in developing a practical implementation of the Eigensystem Realization Algorithm. The effectiveness of the method is illustrated using data from NASA Langley's Controls-Structures-Interaction Evolutionary Model.

Pappa, R. S.↗

Numerical modeling of physical vapor transport under microgravity conditions: Effect of thermal creep and stress

One of the most promising applications of microgravity (micro-g) environments is the manufacture of exotic and high-quality crystals in closed cylindrical ampoules using physical vapor transport (PVT) processes. The quality enhancements are believed to be due to the absence of buoyant convection in the weightless environment - resulting in diffusion-limited transport of the vapor. In a typical experiment, solid-phase sample material is initially contained at one end of the ampoule. The sample is made to sublime into the vapor phase and deposit onto the opposite end by maintaining the source at an elevated temperature with respect to the deposit. Identification of the physical factors governing both the rates and uniformity of crystal growth, and the optimization of the micro-g technology, will require an accurate modeling of the vapor transport within the ampoule. Previous micro-g modeling efforts have approached the problem from a 'classical' convective/diffusion formulation, in which convection is driven by the action of buoyancy on thermal and solutal density differences. The general conclusion of these works have been that in low gravity environments the effect of buoyancy on vapor transport is negligible, and vapor transport occurs in a diffusion-limited mode. However, it has been recently recognized than in the non-isothermal (and often low total pressure) conditions encountered in ampoules, the commonly-assumed no-slip boundary condition to the differential equations governing fluid motion can be grossly unrepresentative of the actual situation. Specifically, the temperature gradients can give rise to thermal creep flows at the ampoule side walls. In addition, temperature gradients in the vapor itself can, through the action of thermal stress, lead to bulk fluid convection.

Mackowski, Daniel W.↗

Generation Mechanisms UV and X-ray Emissions During SL9 Impact

The purpose of this grant was to study the ultraviolet and X-ray emissions associated with the impact of comet Shoemaker-Levy 9 with Jupiter. The University of Michigan task was primarily focused on theoretical calculations. The NAGW-4788 subtask was to be largely devoted to determining the constraints placed by the X-ray observations on the physical mechanisms responsible for the generation of the X-rays. Author summarized below the ROSAT observations and suggest a physical mechanism that can plausibly account for the observed emissions. It is hoped that the full set of activities can be completed at a later date. Further analysis of the ROSAT data acquired at the time of the impact was necessary to define the observational constraints on the magnetospheric-ionospheric processes involved in the excitation of the X-ray emissions associated with the fragment impacts. This analysis centered around improvements in the pointing accuracy and improvements in the timing information. Additional pointing information was made possible by the identification of the optical counterparts to the X-ray sources in the ROSAT field-of-view. Due to the large number of worldwide observers of the impacts, a serendipitous visible plate image from an observer in Venezuela provided a very accurate location of the present position of the X-ray source, virtually eliminating pointing errors in the data. Once refined, the pointing indicated that the two observed X-ray brightenings that were highly correlated in time with the K and P2 events were brightenings of the X-ray aurora (as identified in images prior to the impact).Appendix A "ROSAT observations of X-ray emissions from Jupiter during the impact of comet Shoemaker-Levy 9' also included.

Waite, J. Hunter, Jr.↗

Method and Apparatus for the Portable Identification of Material Thickness and Defects Using Spatially Controlled Heat Application

A method and a portable apparatus for the nondestructive identification of defects in structures. The apparatus comprises a heat source and a thermal imager that move at a constant speed past a test surface of a structure. The thermal imager is off set at a predetermined distance from the heat source. The heat source induces a constant surface temperature. The imager follows the heat source and produces a video image of the thermal characteristics of the test surface. Material defects produce deviations from the constant surface temperature that move at the inverse of the constant speed. Thermal noise produces deviations that move at random speed. Computer averaging of the digitized thermal image data with respect to the constant speed minimizes noise and improves the signal of valid defects. The motion of thermographic equipment coupled with the high signal to noise ratio render it suitable for portable, on site analysis.

Cramer, K. Elliott↗

Suzaku Observation of the Dwarf Nova V893 Scorpii: The Discovery of a Partial X-Ray Eclipse

V893 Sco is an eclipsing dwarf nova that had attracted little attention from X-ray astronomers until it was proposed as the identification of an RXTE all-sky slew survey (XSS) source. Here we report on the po inted X-ray observations of this object using Suzaku. We confirm V893 Sco to be X-ray bright, whose spectrum is highly absorbed for a dwar f nova. We have also discovered a partial X-ray eclipse in V893 Sco. This is the first time that a partial eclipse is seen in Xray light c urves of a dwarf nova. We have successfully modeled the gross features of the optical and X-ray eclipse light curves using a boundary layer geometry of the X-ray emission region. Future observations may lead to confirmation of this basic picture, and allow us to place tight co nstraints on the size of the X-ray emission region. The partial X-ray eclipse therefore should make V893 Sco a key object in understanding the physics of accretion in quiescent dwarf nova.

Mukai, Koji↗

Earthshine as an Illumination Source at the Moon

Earthshine is the dominant source of natural illumination on the surface of the Moon during lunar night, and at some locations within permanently shadowed regions (PSRs) near the poles that never receive direct sunlight. As such, earthshine has the potential to enable the scientific investigation and exploration of conditions in areas of the Moon that are either temporarily or permanently hidden from the Sun. Earthshine has also been used to refer to Earthlight reflected from the lunar surface, but in this study we use it to refer specifically to Earthlight incident at the Moon. Under certain circumstances, the heat flux from earthshine could also influence the transport and cold-trapping of volatiles present in the very coldest areas within PSRs. In this study, Earth's spectral irradiance, as it would appear at the Moon in the solar reflectance band (0.3–3.0 µm) and at thermal emission wavelengths (3–50 µm), is examined with a suite of model image cubes and whole-disk spectra created using the Virtual Planetary Laboratory (VPL) three-dimensional (latitude, longitude and altitude) modeling capability. At the Moon, the broadband, hemispherical irradiance from Earth at full-phase is approximately 0.15 W m−2 with comparable contributions from solar reflectance and thermal emission; for context, this about 0.01% that of solar irradiance and has an equivalent temperature of around 40 K. Over the simulated timeframe, spanning two lunations, Earth's thermal irradiance shows very little net change (less than a few mW m−2 resulting from cloud variability and the south-to-north motion of the sub-observer latitude on Earth). In the solar band, Earth's diurnally averaged light curve at phase angles g ≤ 60° is well-fit using a Henyey–Greenstein integral phase function. At wavelengths longward of about 0.7 µm, near the well-known vegetation “red edge”, Earth's reflected solar radiance shows significant diurnal modulation as a result of the broad maximum in projected landmass at terrestrial longitudes between 60°W and 0°, as well as from the distribution of clouds. A simple formulation with adjustable coefficients is presented, condensed from the VPL model grid, for estimating Earth's hemispherical irradiance at the Moon as a function of wavelength, phase angle and sub-observer coordinates (terrestrial latitude and longitude). Uncertainties in any one prediction are estimated to be 10–12% at 0.3 µm, rising to >25% near 2.5 µm as a result of the increasing relative brightness and unpredictable influence of clouds. Although coefficient values are derived from a suite of spring equinox models, the approximation appears to be valid for all seasons, to within the stated uncertainties. It is demonstrated that earthshine is sufficiently bright to serve as a natural illumination source for optical measurements on a robotic lander/rover, allowing the identification of water ice mixed with regolith at the percent-level of fractional area.

Surface↗

Stable and tunable MeV $$\gamma$$-ray generation via dual-laser inverse Thomson scattering from a laser-plasma accelerator

Abstract Inverse Thomson scattering from laser-plasma accelerators offers a pathway to compact, tunable MeV $$\gamma$$ -ray sources for reduced-dose radiography and enhanced performance in nuclear resonance fluorescence (NRF)-based isotope identification. However, photon yield and spectral quality are often limited by constraints on interaction geometry and scatter-laser tunability. Here we demonstrate a MeV $$\gamma$$ -ray source based on a dual-laser inverse Thomson scattering configuration driven by a 100-TW laser-plasma accelerator. Electron beams tunable from 122 to 204 MeV with $$<5$$ mrad divergence and $$<1$$ mrad pointing stability generate $$\gamma$$ rays with peak energies from 276 keV to 1.2 MeV and yields up to $$2\times 10^{7}$$ photons per shot. By independently controlling the interaction position and the scatter-pulse duration, we experimentally match the scatter pulse to the walk-off-limited interaction length. Extending the scatter pulse to 200 fs increases photon production by approximately $$15\%$$ while maintaining operation in the linear Thomson regime, thereby preserving narrow spectral bandwidth and controlled radiation divergence. Radiographic characterization demonstrates MeV-level penetration and $$\approx 0.1$$ mm spatial resolution, while stable operation is sustained over multi-hour timescales across multiple days. These results show that interaction-length optimization provides a scalable strategy for improving photon yield, spectral control, and operational stability in compact laser-plasma-accelerator-driven $$\gamma$$ -ray sources.

Tsai, Hai-En↗

Maximum Likelihood Spectrum Decomposition for Isotope Identification and Quantification

A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte Carlo simulations were used to build the response matrix of a shielded high-purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared with decay-corrected values from the calibration certificate. For most nuclei in the standard ( 241 Am, 109 Cd, 137 Cs, and 60 Co), the deviations from the certificate values were generally no more than 6% with a few outliers as high as 10%. Furthermore, for 57 Co, the radionuclide with the lowest activity, the deviations from the standard reached as high as 25%, driven by the meager statistics in the calibration spectra. In addition, a complete treatment of error propagation for the technique is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sparse and Random Sampling Techniques for High-Resolution, Full-Field, BSS-Based Structural Dynamics Identification from Video

Video-based techniques for identification of structural dynamics have the advantage that they are very inexpensive to deploy compared to conventional accelerometer or strain gauge techniques. When structural dynamics from video is accomplished using full-field, high-resolution analysis techniques utilizing algorithms on the pixel time series such as principal components analysis and solutions to blind source separation the added benefit of high-resolution, full-field modal identification is achieved. An important property of video of vibrating structures is that it is particularly sparse. Typically video of vibrating structures has a dimensionality consisting of many thousands or even millions of pixels and hundreds to thousands of frames. However the motion of the vibrating structure can be described using only a few mode shapes and their associated time series. As a result, emerging techniques for sparse and random sampling such as compressive sensing should be applicable to performing modal identification on video. This work presents how full-field, high-resolution, structural dynamics identification frameworks can be coupled with compressive sampling. The techniques described in this work are demonstrated to be able to recover mode shapes from experimental video of vibrating structures when 70% to 90% of the frames from a video captured in the conventional manner are removed.

47 OTHER INSTRUMENTATION↗

PAH Products and Processing by Different Energy Sources

Isoviolanthrene (C34H18), a polycyclic aromatic hydrocarbon (PAH) molecule, was studied via matrix isolation in argon and water at 20 K. Infrared spectroscopy was performed in situ where samples were irradiated using ultraviolet light. Experimental spectra were compared to theoretical spectra for vibrational band assignment, determination of the corresponding A-values, and photoproduct identification. Isoviolanthrene was also deposited as a thin film and irradiated with different energy sources: ultraviolet photons (10.2 eV), soft electrons (1.5 keV), protons (1.5 MeV), and He+ particles (1.5 MeV), to understand the effects of different energy sources on a PAH. Anions and cations of soviolanthrene were produced as a result of UV photolysis in an argon matrix. Hydrogenand oxygen-rich aromatic photoproducts were produced by ultraviolet photons when isoviolanthrene was isolated in a water matrix. The irradiated PAH thin films results were dependent on the energy source. Irradiation with ultraviolet photons yielded a broad underlying feature centered at 9.6 μm, while bombardment with soft electrons gave a broad feature centered at 7.7 μm. In the case of proton bombardment, no broad feature was detected, in contrast with He+ bombardment that destroyed most of the isoviolanthrene and produced broad features in the C-Hoop and C–H stretching regions. A comparison of astronomical IR emission observations with our experimental results in the mid-infrared range has revealed a similarity between the observed plateaus and the broad features produced by our experiments.

astrochemistry – infrared: ISM – methods: laborato↗

HEAO A-2 soft X-ray source catalog

The HEAO A-2 low energy X-ray detectors have surveyed over 95% of the sky in the spectral bands 0.18-0.44 and 0.44-2.8 keV, down to a typical limiting sensitivity of 1 x 10 to the -11th and 3 x 10 to the -11th ergs per sq cm per sec in each band, respectively. Using a significance criterion of 6 sigma for existence, 114 sources are cataloged, of which 54 were previously undiscovered and 32 remain unidentified. The catalog contains a listing of all counterpart identifications and a cross-reference to all HEAO 1 A-2 low energy detector team publications on the catalog sources complete through the end of 1981. Supplementary material allows the estimation of spectral parameters for the spectral models from the observed intensities. Simple graphs allow the extraction of energy fluxes at the earth, both with and without the effects of interstellar absorption. The angular distribution of the cataloged sources in the 0.44-2.8 keV band is concentrated toward the galactic plane and resembles that seen at higher energy. The distribution in the 0.18-0.44 keV band is more uniform and contains many more newly discovered and unidentified sources.

Nugent, J. J.↗

Helicopter main-rotor noise: Determination of source contributions using scaled model data

Acoustic data from a test of a 40 percent model MBB BO-105 helicopter main rotor are scaled to equivalent full-scale flyover cases. The test was conducted in the anechoic open test section of the German-Dutch Windtunnel (DNW). The measured data are in the form of acoustic pressure time histories and spectra from two out-of-flow microphones underneath and foward of the model. These are scaled to correspond to measurements made at locations 150 m below the flight path of a full-scale rotor. For the scaled data, a detailed analysis is given for the identification in the data of the noise contributions from different rotor noise sources. Key results include a component breakdown of the noise contributions, in terms of noise criteria calculations of a weighted sound pressure level (dBA) and perceived noise level (PNL), as functions of rotor advance ratio and descent angle. It is shown for the scaled rotor that, during descent, impulsive blade-vortex interaction (BVI) noise is the dominant contributor to the noise. In level flight and mild climb, broadband blade-turbulent wake interaction (BWI) noise is dominant due to the absence of BVI activity. At high climb angles, BWI is reduced and self-noise from blade boundary-layer turbulence becomes the most prominent.

Brooks, Thomas F.↗

A search for the lenses in the Herschel Bright Sources (HerBS) sample

ABSTRACT Verifying that sub-mm galaxies are gravitationally lensed requires time-expensive observations with oversubscribed high-resolution observatories. Here, we aim to strengthen the evidence of gravitational lensing within the Herschel Bright Sources (HerBS) by cross-comparing their positions to optical (SDSS) and near-infrared (VIKING) surveys, in order to search for the foreground lensing galaxy candidates. Resolved observations of the brightest HerBS sources have already shown that most are lensed, and a galaxy evolution model predicts that ∼76 per cent of the total HerBS sources are lensed, although with the SDSS survey we are only able to identify the likely foreground lenses for 25 per cent of the sources. With the near-infrared VIKING survey, however, we are able to identify the likely foreground lenses for 57 per cent of the sources, and we estimate that 82 per cent of the HerBS sources have lenses on the VIKING images even if we cannot identify the lens in every case. We find that the angular offsets between lens and Herschel source are larger than that expected if the lensing is done by individual galaxies. We also find that the fraction of HerBS sources that are lensed falls with decreasing 500-micron flux density, which is expected from the galaxy evolution model. Finally, we apply our statistical VIKING cross-identification to the entire Herschel-ATLAS catalogue, where we also find that the number of lensed sources falls with decreasing 500-micron flux density.

Bakx, Tom J. L. C.↗

Identification and Computation of Individual Propeller Acoustics of the Joby Aviation Aircraft

The individual propeller sources of the Joby Aviation aircraft are separated using an order tracking filter on measurement data and computed using high- fidelity computational fluid dynamics (CFD) to quantify the relative contributions to the total noise. Computational results are verified against experimental data for hover and steady level flight at 60 knots and demonstrate very good agreement of both overall sound pressure level magnitude and directivity. The propeller source separation for hover shows good agreement between the methods except for the inboard propellers, and it is expected that the assumptions in the CFD model do not accurately capture the flight test condition. Both methods are able to separate the higher tonal levels generated by the tail propellers due to the aerodynamic interaction. Overall, considering the discrepancies between the CFD model and flight test, the agreement in Vold-Kalman-filtered results and prediction yields confidence that the separation method is successful.

eVTOL↗

A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking

Purpose: Verification of high dose rate (HDR) brachytherapy treatment delivery is an important step, but is generally difficult to achieve. A technique is required to monitor the treatment as it is delivered, allowing comparison with the treatment plan and error detection. In this work, we demonstrate a method for monitoring the treatment as it is delivered and directly comparing the delivered treatment with the treatment plan in the clinical workspace. This treatment verification system is based on a flat panel detector (FPD) used for both pre-treatment imaging and source tracking. Methods: A phantom study was conducted to establish the resolution and precision of the system. A pretreatment radiograph of a phantom containing brachytherapy catheters is acquired and registration between the measurement and treatment planning system (TPS) is performed using implanted fiducial markers. The measured catheter paths immediately prior to treatment were then compared with the plan. During treatment delivery, the position of the {sup 192}Ir source is determined at each dwell position by measuring the exit radiation with the FPD and directly compared to the planned source dwell positions. Results: The registration between the two corresponding sets of fiducial markers in the TPS and radiograph yielded a registration error (residual) of 1.0 mm. The measured catheter paths agreed with the planned catheter paths on average to within 0.5 mm. The source positions measured with the FPD matched the planned source positions for all dwells on average within 0.6 mm (s.d. 0.3, min. 0.1, max. 1.4 mm). Conclusions: We have demonstrated a method for directly comparing the treatment plan with the delivered treatment that can be easily implemented in the clinical workspace. Pretreatment imaging was performed, enabling visualization of the implant before treatment delivery and identification of possible catheter displacement. Treatment delivery verification was performed by measuring the source position as each dwell was delivered. This approach using a FPD for imaging and source tracking provides a noninvasive method of acquiring extensive information for verification in HDR prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

Observations of several new transitions of interstellar HCO

Four new transitions of the interstellar formyl radical, HCO have been detected. Five transitions are now known for interstellar HCO, and thus its identification is secure. The column density found by assuming NGC 2024 is an extended source is N subT(HCO) = (8.5 + or - 4.0) x 10 to the 12th/sq cm. This gives a fractional abundance (abundance relative to hydrogen) for NGC 2024 which agrees quite well with some theoretical predictions. Several unidentified lines were detected and are reported here. Tentative identification for some of the unidentified lines are suggested.

Snyder, L. E.↗

Ground-based infrared observations of variable IRAS sources as candidates for late asymptotic giant branch stars

Analysis of the color distribution of OH/IR stars and IRAS low-resolution spectra class 30 objects suggests the presence of a well-defined evolutionary sequence which is populated by late asymptotic giant branch (LAGB) stars. The paper reports ground-based identification and infrared photometry of 10 candidates of news LAGB stars. None of the selected sources are found to have optical counterparts, and eight of the 10 show a strong 10-micron silicate absorption feature. It is suggested that these stars represent an invisible extension of extreme Mira variables and are some of the most evolved stars observed to date.

Kwok, Sun↗

TU-AB-201-09: Calibration of An Element of a New Directional Pd-103 Planar Source Array

Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗