Images of the laser entrance hole from the static x-ray imager at NIF

The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60 {mu}m spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-184: Proton Computed Tomography Using 1D Silicon Diode Array

Purpose: Proton radiography and proton computed tomography (PCT) can be used to measure proton stopping power directly. However, practical and cost effective proton imaging detectors are not widely available. In this study, the authors investigated the feasibility of proton imaging using a silicon diode array. Methods: A one-dimensional silicon-diode detector array (1DSDA) was aligned with the central axis (CAX) of the proton beam. Polymethyl methacrylate (PMMA) slabs were used to find the correspondence between the water equivalent thickness (WET) and 1DSDA channel number. 2D proton radiographs (PR) were obtained by translation and rotation of a phantom relative to CAX while the proton nozzle and 1DSDA were kept stationary. A PCT image of one slice of the phantom was reconstructed using filtered backprojection. Results: PR and PCT images of the PMMA cube were successfully acquired using the 1DSDA. The WET of the phantom was measured using PR data with an accuracy of 4.2% or better. Structures down to 1 mm in size could be resolved. Reconstruction of a PCT image showed very good agreement with simulation. Limitations in spatial resolution are attributed to limited spatial sampling, beam collimation, and proton scatter. Conclusion: The results demonstrate the feasibility of using silicon diode arrays for proton imaging. Such a device can potentially offer fast image acquisition, high spatial and energy resolution for PR and PCT.

60 APPLIED LIFE SCIENCES↗

Cathode Strip Chambers in ATLAS: Installation, Commissioning and in situ Performance

The Muon Spectrometer of the ATLAS detector at the LHC is designed to provide high quality stand-alone muon identification, momentum measurement and trigger capabilities with high pseudorapidity coverage. Precision tracking at the inner-most station in the high pseudorapidity regions, 2.3 < |eta| < 2.7, is performed by 16 four-layered Cathode Strip Chambers on each end-cap. These are multi-wire proportional chambers with segmented cathodes providing excellent spatial resolution and high counting rate capability. The second cathode of each layer is coarsely segmented, providing the transverse coordinate. The detector level performance of the system is presented. The installation and commissioning effort for the Cathode Strip Chambers is described. Finally, the in situ performance is briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-H-CAMPUS-TeP2-03: High Sensitivity and High Resolution Fiber Based Micro-Detector for Sub-Millimeter Preclinical Dosimetry

Purpose: Current precision of small animal and cell micro-irradiators has continuously increased during the past years. Currently, preclinical irradiators can deliver sub-millimeter fields with micrometric precision but there are no water equivalent dosimeters to determine small field profiles and dose in the orthovoltage range of energies with micrometric resolution and precision. We have developed a fiber based micro-dosimeter with the resolution and dosimetric accuracy required for radiobiological research. Methods: We constructed two prototypes of micro-dosimeters based on different compositions of fiber scintillators to study the spatial resolution and dosimetric precision of small animal and cell micro-irradiators. The first has green output and the second has blue output. The blue output dosimeter has the highest sensitivity because it matches the spectral sensitivity of silicon photomultipliers. A blue detector with 500um cross section was built and tested respect to a CC01 ion chamber, film, and the 1500um green output detector. Orthovoltage fields from 1×1mm2 to 5×5mm2 were used for detector characteristics comparison. Results: The blue fiber dosimeter shows great agreement with films and matches dose measurements with the gold-standard ion chamber for 5×5mm2 fields. The detector has the appropriate sensitivity to measure fields from 1×1mm2 to larger sizes with a 1% dosimetric accuracy. The spatial resolution is in the sub-millimeter range and the spectral matching with the photomultiplier allows reducing the sensor cross section even further than the presented prototype. These results suggest that scintillating fibers combined with silicon photomultipliers is the appropriate technology to pursue micro-dosimetry for small animals and disperse cell samples. Conclusion: The constructed detectors establish a new landmark for the resolution and sensitivity of fiber based microdetectors. The validation of the detector in our small animal and cell irradiator shows that they are appropriate for preclinical and micro single cell irradiation quality assurance and dosimetry.

60 APPLIED LIFE SCIENCES↗

X-ray modulation transfer functions of photostimulable phosphor image plates and scanners

The modulation transfer functions of two types of photostimulable phosphor image plates were determined in the 10 keV to 50 keV x-ray energy range using a resolution test pattern with up to 10 line pairs per mm (LP/mm) and a wavelength dispersive x-ray spectrometer. Techniques were developed for correcting for the partial transmittance of the high energy x rays through the lead bars of the resolution test pattern, and the modulation transfer function (MTF) was determined from the measured change in contrast with LP/mm values. The MTF was convolved with the slit function of the image plate scanner, and the resulting point spread functions (PSFs) were in good agreement with the observed shapes and widths of x-ray spectral lines and with the PSF derived from edge spread functions. The shapes and the full width at half-maximum (FWHM) values of the PSF curves of the Fuji Superior Resolution (SR) and Fuji Maximum Sensitivity (MS) image plate detectors, consisting of the image plate and the scanner, determined by the three methods gave consistent results: The SR PSF is Gaussian with 0.13 mm FWHM, and the MS PSF is Lorentzian with 0.19 mm FWHM. These techniques result in the accurate determination of the spatial resolution achievable using image plate and scanner combinations and enable the optimization of spatial resolution for x-ray spectroscopy and radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density fluctuation measurements using beam emission spectroscopy on Heliotron J

This paper describes the measurement of the density fluctuation using beam emission spectroscopy in Heliotron J, having the non-symmetrical helical-magnetic-axis configuration. In order to optimize the sightlines, the numerical calculations are carried out to estimate the spatial resolution and the observation location. When a tangential neutral beam is used as diagnostic one, suitable sightlines from the newly installed diagnostic port are selected whose spatial resolution {Delta}{rho} is less than {+-}0.07 over the entire plasma region. Modification of the interference filter and the detection systems enables us to measure the radial profile of the density fluctuation. Each of the three coherent modes due to the fast-ion-driven magnetohydrodynamic instabilities has different radial structure of the density fluctuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of absolute extreme ultraviolet diagnostic on J-TEXT

The absolute extreme ultraviolet (AXUV) diagnostic system is used for radiation observation on J-TEXT tokamak [J. Zhang, G. Zhuang, Z. J. Wang, Y. H. Ding, X. Q. Zhang, and Y. J. Tang, Rev. Sci. Instrum. 81, 073509 (2010)]. The upgrade of the AXUV system is aimed to improve the spatial resolution and provide a three-dimensional image on J-TEXT. The new system consists of 12 AXUV arrays (4 AXUV16ELG arrays, 8 AXUV20ELG arrays). The spatial resolution in the cross-section is 21 mm for the AXUV16ELG arrays and 17 mm for the AXUV20ELG arrays. The pre-amplifier is also upgraded for a higher signal to noise ratio. By upgrading the AXUV imaging system, a more accurate observation on the radiation information is obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(U) Estimating the Photonics Budget, Resolution, and Signal Requirements for a Multi-Monochromatic X-ray Imager

This document examines the performance of a generic flat-mirror multimonochromatic imager (MMI), with special emphasis on existing instruments at NIF and Omega. We begin by deriving the standard equation for the mean number of photons detected per resolution element. The pinhole energy bandwidth is a contributing factor; this is dominated by the finite size of the source and may be considerable. The most common method for estimating the spatial resolution of such a system (quadrature addition) is, technically, mathematically invalid for this case. However, under the proper circumstances it may produce good estimates compared to a rigorous calculation based on the convolution of point-spread functions. Diffraction is an important contribution to the spatial resolution. Common approximations based on Fraunhofer (farfield) diffraction may be inappropriate and misleading, as the instrument may reside in multiple regimes depending upon its configuration or the energy of interest. It is crucial to identify the correct diffraction regime; Fraunhofer and Fresnel (near-field) diffraction profiles are substantially different, the latter being considerably wider. Finally, we combine the photonics and resolution analyses to derive an expression for the minimum signal level such that the resulting images are not dominated by photon statistics. This analysis is consistent with observed performance of the NIF MMI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GPU Acceleration of Kernel Density Estimators in Monte Carlo Neutron Transport Simulations

Kernel Density Estimators (KDEs) have recently been explored for use in Monte Carlo radiation transport simulations as an alternative to histogram tallies for capturing spatially-resolved quantities such as neutron flux and reaction rates. Histogram tallies suffer from large uncertainties when detailed spatial resolution of the quantity of interest is required; increasing the resolution of the underlying mesh increases the uncertainty in each histogram bin. KDEs obtain estimates of underlying densities on user-defined points, with the uncertainty at those points being independent of the spatial resolution desired since collisions and particle-track segments are allowed to contribute to the score at multiple tally points. Thus, KDEs show potential for obtaining estimates of a smoother spatially-resolved with reduced variance when compared to a histogram. However, this ability that enables KDEs to obtain lower uncertainties per particle history is more computationally expensive than using a traditional histogram bins on a structured mesh. While KDEs are capable of producing lower tally uncertainties compared to histogram binning for a given number of histories, their increased computational cost may make them less efficient. Even so, it is possible to reduce this additional cost by exporting the KDE tally routines onto Graphics Processing Units (GPUs). GPUs are commonly found on high-performance computing machines as a means of increasing performance without adding additional compute nodes. While it is difficult for existing Monte Carlo radiation transport codes to take advantage of GPUs without rewriting large portions of the code, it is possible to leverage GPUs through heterogeneous computing. This work uses a modified version of OpenMC and exports the KDE tally routines onto a GPU to obtain problem-dependent speedups ranging between 1.6 and 5.0 for the problem studied in this paper. While this methodology is applied to KDEs, the same ideas can be applied to other computationally expensive vectorizable portions of Monte Carlo algorithms. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mineral Associations and Character of Isotopically Anomalous Organic Material in the Tagish Lake Carbonaceous Chondrite

We report a coordinated analytical study of matrix material in the Tagish Lake carbonaceous chondrite in which the same small ({le}20 {micro}m) fragments were measured by secondary ion mass spectrometry (SIMS), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), electron energy-loss spectroscopy (EELS), and X-ray absorption near-edge spectroscopy (XANES). SIMS analysis reveals H and N isotopic anomalies (hotspots), ranging from hundreds to thousands of nanometers in size, which are present throughout the fragments. Although the differences in spatial resolution of the SIMS techniques we have used introduce some uncertainty into the exact location of the hotspots, in general, the H and N isotopic anomalies are spatially correlated with C enrichments, suggesting an organic carrier. TEM analysis, enabled by site-specific extraction using a focused-ion-beam scanning-electron microscope, shows that the hotspots contain an amorphous component, Fe-Ni sulfides, serpentine, and mixed-cation carbonates. TEM imaging reveals that the amorphous component occurs in solid and porous forms, EDS indicates that it contains abundant C, and EELS and XANES at the C K edge reveal that it is largely aromatic. This amorphous component is probably macromolecular C, likely the carrier of the isotopic anomalies, and similar to the material extracted from bulk samples as insoluble organic matter. However, given the large sizes of some of the hotspots, the disparity in spatial resolution among the various techniques employed in our study, and the phases with which they are associated, we cannot entirely rule out that some of the isotopic anomalies are carried by inorganic material, e.g., sheet silicates. The isotopic composition of the organic matter points to an initially primitive origin, quite possibly within cold interstellar clouds or the outer reaches of the solar protoplanetary disk. The association of organic material with secondary phases, e.g., serpentine and carbonates, suggests that the organic matter was susceptible to parent-body processing, and thus, isotopic dilution.

58 GEOSCIENCES↗

TH-A-18C-01: Design Optimization of Segmented Scintillators for Megavoltage Cone- Beam CT

Purpose: Active matrix flat-panel imagers incorporating thick, segmented scintillators for megavoltage cone-beam CT (MV CBCT) imaging have demonstrated strong potential for facilitating soft-tissue visualization at low, clinically practical doses. In order to identify scintillator design parameters that optimize performance for this purpose, a modeling technique which includes both radiation and optical effects and which lends itself to computationally practical implementation has been developed and explored. Methods: A hybrid modeling technique, based on Monte Carlo event-by-event simulation of radiation transport and separate determination of optical effects, was devised as an alternative to computationally prohibitive event-by- event simulations of both radiation and optical transport. The technique was validated against empirical results from a previously reported 1.13 cm thick, 1.016 mm element-to-element pitch BGO scintillator prototype. Using this technique, the contrast-to-noise ratio (CNR) and spatial resolution performance of numerous scintillator designs, with thicknesses ranging from 0.5 to 6 cm and pitches ranging from 0.508 to 1.524 mm, were examined. Results: CNR and spatial resolution performance for the various scintillator designs demonstrate complex behavior as scintillator thickness and pitch are varied - exhibiting a clear trade-off between these two imaging metrics up to a thickness of ~3 cm. Based on these results, an optimization map highlighting those regions of design that provide a balance between these metrics was created. The map indicates that, for a given set of optical parameters, scintillator thickness and pitch can be judiciously chosen to maximize performance without resorting to thicker, more costly scintillators. Conclusion: Modeling radiation and optical effects in thick, segmented scintillators through use of a hybrid modeling technique provides a practical way to gain insight as to how to optimize the performance of such devices for radiotherapy imaging. Assisted by such modeling, the development of practical designs should greatly facilitate low-dose, soft tissue visualization through MV CBCT imaging. This project was supported in part by NIH grant R01 CA051397.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Electrical Imaging and Distributed Temperature Sensing Methods to Characterize Surface Water-Groundwater Exchange Regulating Uranium Transport at the Hanford 300 Area, Washington

A critical challenge in advancing prediction of solute transport between contaminated aquifers and rivers is improving understanding of how fluctuations in river stage, combined with subsurface heterogeneity, impart spatiotemporal complexity to solute exchange along river corridors. Here, we explored the use of waterborne geoelectrical imaging, in conjunction with fiber-optic distributed temperature sensor (DTS) monitoring, to improve the conceptual model for uranium transport within the hyporheic corridor at the Hanford 300 Area. We first inverted waterborne geoelectrical (resistivity and induced polarization) datasets for distributions of electrical resistivity and polarizability, from which the spatial complexity of the primary hydrogeologic units was reconstructed. Variations in the depth to the interface between the overlying coarse-grained, high permeability Hanford formation and the underlying finer-grained, less permeable Ringold formation, an important contact that limits vertical migration of contaminants, were resolved along ~3 km of the river corridor centered on the 300 Area. Polarizability images were translated into lithologic images using established relationships between polarizability and surface area normalized to pore volume (Spor). The spatial variability captured in the geoelectrical datasets indicates that previous studies based on borehole projections and point probing overestimate the contributing area for uranium exchange within the Columbia River at the Hanford 300 Area. The DTS data recorded on 1. 5 km of cable with a 1 m spatial resolution and 5 minute sampling interval revealed sub-reaches showing (1) high temperature anomalies and, (2) a strong negative correlation between temperature and river stage, both indicative of groundwater influxes during winter months. The DTS datasets confirm the hydrologic significance of the variability identified in the geoelectrical imaging and reveal a pattern of highly focused hyporheic exchange, with exchange concentrated at springs where the Hanford formation is thick, and coinciding with a paleochannel identified in ground penetrating radar surveys at one location. No evidence for focused hyporheic exchange is observed in the DTS data where the Ringold unit is in contact with the riverbed. Our findings illustrate how the combination of waterborne geoelectrical imaging and DTS technologies can characterize hyporheic exchange in a complex, coupled river-aquifer system.

300 area↗

SIFT-based dense pixel tracking on 0.35 T cine-MR images acquired during image-guided radiation therapy with application to gating optimization

Purpose: To first demonstrate the viability of applying an image processing technique for tracking regions on low-contrast cine-MR images acquired during image-guided radiation therapy, and then outline a scheme that uses tracking data for optimizing gating results in a patient-specific manner. Methods: A first-generation MR-IGRT system—treating patients since January 2014—integrates a 0.35 T MR scanner into an annular gantry consisting of three independent Co-60 sources. Obtaining adequate frame rates for capturing relevant patient motion across large fields-of-view currently requires coarse in-plane spatial resolution. This study initially (1) investigate the feasibility of rapidly tracking dense pixel correspondences across single, sagittal plane images (with both moderate signal-to-noise and spatial resolution) using a matching objective for highly descriptive vectors called scale-invariant feature transform (SIFT) descriptors associated to all pixels that describe intensity gradients in local regions around each pixel. To more accurately track features, (2) harmonic analysis was then applied to all pixel trajectories within a region-of-interest across a short training period. In particular, the procedure adjusts the motion of outlying trajectories whose relative spectral power within a frequency bandwidth consistent with respiration (or another form of periodic motion) does not exceed a threshold value that is manually specified following the training period. To evaluate the tracking reliability after applying this correction, conventional metrics—including Dice similarity coefficients (DSCs), mean tracking errors (MTEs), and Hausdorff distances (HD)—were used to compare target segmentations obtained via tracking to manually delineated segmentations. Upon confirming the viability of this descriptor-based procedure for reliably tracking features, the study (3) outlines a scheme for optimizing gating parameters—including relative target position and a tolerable margin about this position—derived from a probability density function that is constructed using tracking results obtained just prior to treatment. Results: The feasibility of applying the matching objective for SIFT descriptors toward pixel-by-pixel tracking on cine-MR acquisitions was first retrospectively demonstrated for 19 treatments (spanning various sites). Both with and without motion correction based on harmonic analysis, sub-pixel MTEs were obtained. A mean DSC value spanning all patients of 0.916 ± 0.001 was obtained without motion correction, with DSC values exceeding 0.85 for all patients considered. While most patients show accurate tracking without motion correction, harmonic analysis does yield substantial gain in accuracy (defined using HDs) for three particularly challenging subjects. An application of tracking toward a gating optimization procedure was then demonstrated that should allow a physician to balance beam-on time and tissue sparing in a patient-specific manner by tuning several intuitive parameters. Conclusions: Tracking results show high fidelity in assessing intrafractional motion observed on cine-MR acquisitions. Incorporating harmonic analysis during a training period improves the robustness of the tracking for challenging targets. The concomitant gating optimization procedure should allow for physicians to quantitatively assess gating effectiveness quickly just prior to treatment in a patient-specific manner.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of a clinical unit for digital radiography based on irradiation side sampling technology

Purpose: A characterization of a clinical unit for digital radiography (FUJIFILM FDR D-EVO) is presented. This system is based on the irradiation side sampling (ISS) technology and can be equipped with two different scintillators: one traditional gadolinium-oxysulphide phosphor (GOS) and a needle structured cesium iodide (CsI) phosphor panel.Methods: The characterization was achieved in terms of response curve, modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). For both scintillation screens the authors accomplished the measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9.Results: At the Nyquist frequency (3.33 lp/mm) the MTF is about 35% and 25% for CsI and GOS detectors, respectively. The CsI scintillator has better noise properties than the GOS screen in almost all the conditions. This is particularly true for low-energy beams, where the noise for the GOS system can go up to a factor 2 greater than that found for CsI. The DQE of the CsI detector reaches a peak of 60%, 60%, 58%, and 50% for the RQA3, RQA5, RQA7, and RQA9 beams, respectively, whereas for the GOS screen the maximum DQE is 40%, 44%, 44%, and 35%. The contrast-detail analysis confirms that in the majority of cases the CsI scintillator is able to provide improved outcomes to those obtained with the GOS screen.Conclusions: The limited diffusion of light produced by the ISS reading makes possible the achievement of very good spatial resolution. In fact, the MTF of the unit with the CsI panel is only slightly lower to that achieved with direct conversion detectors. The combination of very good spatial resolution, together with the good noise properties reached with the CsI screen, allows achieving DQE on average about 1.5 times greater than that obtained with GOS. In fact, the DQE of unit equipped with CsI is comparable to the best alternative methods available which are based on the same technology, and similar to others based on an a-Se direct conversion detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross strip microchannel plate imaging photon counters with high time resolution

We have implemented cross strip readout microchannel plate detectors in 18 mm active area format including open face (UV/particle) and sealed tube (optical) configurations. These have been tested with a field programmable gate array based parallel channel electronics for event encoding which can process high input event rates (> 5 MHz) with high spatial resolution. Using small pore MCPs (6 {micro}m) operated in a pair, we achieve gains of >5 x 10{sup 5} which is sufficient to provide spatial resolution of <35 {micro}m FHWM, with self triggered event timing accuracy of {approx}2 ns for sealed tube optical sensors. A peak quantum efficiency of {approx}19% at 500 nm has been achieved with SuperGenII photocathodes that have response over the 400 nm to 900 nm range. Local area counting rates of up to >200 events/mcp pore sec{sup -1} have been attained, along with image linearity and stability to better than 50 {micro}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-H-207A-01: Computational Evaluation of High-Resolution 18F Positron Imaging Using Radioluminescence Microscopy with Lu2O3: Eu Thin-Film Scintillator

Purpose: Radioluminescence microscopy, an emerging and powerful tool for high resolution beta imaging, has been applied to molecular imaging of cellular metabolism to understand tumor biology. A novel thin-film (10 µm thickness) scintillator made of Lu{sub 2}O{sub 3}: Eu has been developed to enhance the system performance. However the advances of radioluminescence imaging with Lu{sub 2}O{sub 3}scintillator compared with that using conventional scintillator have not been explored theoretically to date. To validate the advantages of the thin-film scintillator, this study uses a novel computational simulation framework to evaluate the performance of radioluminescence microscopy using both conventional and thin-film scintillators. Methods: Numerical models for different stages of positron imaging are established. Positron from {sup 18}F passing through the scintillator and its neighbor structures are modeled by Monte-Carlo simulation using Geant4. The propagation and focus of photons by the microscope are modeled by convolution with a depth-varying point spread function generated by the Gibson-Lanni model. Photons focused on the detector plane are then captured and converted into electronic signals by an electron multiplication (EM) CCD camera, which is described by a photosensor model considering various noises and charge amplification. Results: The performance metrics of radioluminescence imaging with a thin-film Lu{sub 2}O{sub 3} and conventional CdWO{sub 4} scintillator are compared, including spatial resolution, sensitivity, positron track area and intensity. The spatial resolution of Lu{sub 2}O{sub 3} system can achieve 10 µm maximally, a 12 µm enhancement from that obtained from CdWO{sub 4} system. Meanwhile, the system with Lu{sub 2}O{sub 3} scintillator can provide a higher mean sensitivity: 40% compared with that (21.5%) obtained from CdWO{sub 4} system. Moreover, the simulation results are in good agreement with previous experimental measurements. Conclusion: This study provides a new theoretical understanding of our imaging system and has the potential to promote the development of radioluminescence microscopy for more reliable and robust application on the functional imaging of delicate biological structures. The authors acknowledge funding from NIH grant R01CA186275 and SBIR grant 1R43GM110888-01.

60 APPLIED LIFE SCIENCES↗

High quality single shot ultrafast MeV electron diffraction from a photocathode radio-frequency gun

A compact ultrafast electron diffractometer, consisting of an s-band 1.6 cell photocathode radio-frequency gun, a multi-function changeable sample chamber, and a sensitive relativistic electron detector, was built at Shanghai Jiao Tong University. High-quality single-shot transmission electron diffraction patterns have been recorded by scattering 2.5 MeV electrons off single crystalline gold and polycrystalline aluminum samples. The high quality diffraction pattern indicates an excellent spatial resolution, with the ratio of the diffraction ring radius over the ring rms width beyond 10. The electron pulse width is estimated to be about 300 fs. The high temporal and spatial resolution may open new opportunities in various areas of sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗