Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Laser Spectroscopy of Exotic Atoms and Molecules Containing Octupole-Deformed Nuclei

This project investigated the nuclear, atomic, and molecular structure of exotic atoms and molecules containing actinide isotopes. These short-lived radioactive systems are challenging to produce and study in the laboratory, yet they offer unique opportunities for fundamental science. These nuclei are predicted to exhibit pear-shaped (octupole) deformation, a rare collective nuclear behavior that dramatically enhances their sensitivity to fundamental physics phenomena such as time-reversal- and parity-violating effects. Such enhancements make them ideal probes for exploring open questions in our understanding of the universe such as the origin of the matter–antimatter asymmetry of the universe. To realize these measurements, the project led the development of a new laser spectroscopy experiment at MIT, and later commissioned at the Facility for Rare Isotope Beams (FRIB) at Michigan State University: the Resonance Ionization Spectroscopy Experiment (RISE). RISE combines the spectroscopic precision of collinear laser spectroscopy with the sensitivity of particle-detection techniques, enabling measurements of rare isotopes produced at rates as low as a few ions per second. The beamline was designed, built, and installed, and was successfully commissioned at FRIB during the grant period. RISE is now a permanent capability of the FRIB facility, and has produced several results on the study of rare atoms and molecules for nuclear structure and fundamental symmetries. In parallel with the FRIB program, the project contributed to the first precision laser-spectroscopy measurements of short-lived radioactive molecules. Working with international collaborators at CERN's ISOLDE facility, the team conducted pioneering experiments on radium monofluoride (RaF) and actinium monofluoride (AcF). The results from this work have been published in major journals of science, including Nature, Science, Nature Physics, Nature Communications, and Physical Review Letters. These findings have guided future experiments on the laser cooling of radioactive molecules, opening a new platform for precision tests of fundamental symmetries.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluating lignocellulosic biomass, its derivatives, and downstream products with Raman spectroscopy

The creation of fuels, chemicals, and materials from plants can aid in replacing products fabricated from non-renewable energy sources. Before using biomass in downstream applications, it must be characterized to assess chemical traits, such as cellulose, lignin, or lignin monomer content, or the sugars released following an acid or enzymatic hydrolysis. The measurement of these traits allows researchers to gage the recalcitrance of the plants and develop efficient deconstruction strategies to maximize yields. Standard methods for assessing biomass phenotypes often have experimental protocols that limit their use for screening sizeable numbers of plant species. Raman spectroscopy, a non-destructive, non-invasive vibrational spectroscopy technique, is capable of providing qualitative, structural information and quantitative measurements. Applications of Raman spectroscopy have aided in alleviating the constraints of standard methods by coupling spectral data with multivariate analysis to construct models capable of predicting analytes. Hydrolysis and fermentation products, such as glucose and ethanol, can be quantified off-, at-, or on-line. Raman imaging has enabled researchers to develop a visual understanding of reactions, such as different pretreatment strategies, in real-time, while also providing integral chemical information. Finally, this review provides an overview of what Raman spectroscopy is, and how it has been applied to the analysis of whole lignocellulosic biomass, its derivatives, and downstream process monitoring.

09 BIOMASS FUELS↗

Exploring the Limits of Biological Complexity Amenable to Studies by Incoherent Neutron Spectroscopy

The wavelengths of neutrons available at neutron scattering facilities are comparable with intra- and inter-molecular distances, while their energies are comparable with molecular vibrational energies, making such neutrons highly suitable for studies of molecular-level dynamics. The unmistakable trend in neutron spectroscopy has been towards measurements of systems of greater complexity. Several decades of studies of dynamics using neutron scattering have witnessed a progression from measurements of solids to liquids to protein complexes and biomembranes, which may exhibit properties characteristic of both solids and liquids. Over the last two decades, the frontier of complexity amenable to neutron spectroscopy studies has reached the level of cells. Considering this a baseline for neutron spectroscopy of systems of the utmost biological complexity, we briefly review what has been learned to date from neutron scattering studies at the cellular level and then discuss in more detail the recent strides into neutron spectroscopy of tissues and whole multicellular organisms.

59 BASIC BIOLOGICAL SCIENCES↗

No Neon, but Jets in the Remarkable Recurrent Nova M31N 2008-12a?—Hubble Space Telescope Spectroscopy of the 2015 Eruption

The 2008 discovery of an eruption of M31N 2008-12a began a journey on which the true nature of this remarkable recurrent nova continues to be revealed. M31N 2008-12a contains a white dwarf (WD) close to the Chandrasekhar limit, accreting at a high rate from its companion, and undergoes thermonuclear eruptions that are observed yearly and may even be twice as frequent. In this paper, we report on Hubble Space Telescope Space Telescope Imaging Spectrograph ultraviolet spectroscopy taken within days of the predicted 2015 eruption, coupled with Keck spectroscopy of the 2013 eruption. Together, this spectroscopy permits the reddening to be constrained to E(B−V)=0.10±0.03. The UV spectroscopy reveals evidence for highly ionized, structured, and high-velocity ejecta at early times. No evidence for neon is seen in these spectra, however, but it may be that little insight can be gained regarding the composition of the WD (CO versus ONe).

79 ASTRONOMY AND ASTROPHYSICS↗

Laser-Induced Breakdown Spectroscopy: Application to Powder Samples

Laser-induced breakdown spectroscopy (LIBS) is an atomic emission spectroscopy technique which with the help of a broad band spectrometer can simultaneously perform multi-elemental and in situ analysis of various samples (solid, liquid, powder or gaseous) and various environments which are sometimes difficult to access with standard chemical analytical techniques. In this chapter, we focus on some applications of LIBS on powder samples with varying concentration and how to reduce the matrix effects. By “matrix effect,” we refer to the influence of the physical and chemical properties of the sample on the plasma excitation. The possibility of developing a LIBS based sensor system for total carbon quantification in soil samples is discussed and the feasibility of laser-induced breakdown spectroscopy for the analysis of gasification slag is investigated. The results of these two analyses are compared with those obtained from a carbon analyzer and inductively coupled plasma-optical emission spectroscopy (ICP-OES).

36 MATERIALS SCIENCE↗

To Sample or Not to Sample - An Investigation Into the Uncertainty from Sampling Followed by Laboratory Analysis Versus In-Toto Gamma Spectroscopy for Situations of Non-Uniform Radioactivity Distribution

During the decommissioning of structures and the remediation of soil, material that is known or suspected to be contaminated with radioactivity must be assayed. For many, if not most, of the cases, the radioactive material concentration can be determined or inferred by gamma spectroscopy. In most, if not all, of these cases, the radioactivity is not uniformly distributed. For these situations, is it better to perform in-toto measurements of the entire item, or is it better to extract a sample and analyze that sample? For the in-toto gamma spectroscopy measurement, the results will not be accurate unless the calibration method perfectly represents the measured item. And since the calibrations normally assume uniformly distributed radioactivity, any nonuniform distribution of radioactivity in the measured material will cause an error in the results. A mathematical program using probabilistic methods has been developed to estimate the uncertainty in in-toto gamma spectroscopy measurements. This program has the capability of determining the efficiency of various types of non-uniform radioactivity distributions and to compare it to the uniform distribution efficiency. Repeating this for a large number of random tries allows the estimation of the measurement uncertainty. A new feature has been added to the program to simulate the extraction of a sample from these same non-uniform distributions, to compute the average concentration in this extracted sample, and to compare it to the average concentration in the original item to be measured. Repeating this for a large number of random tries allows the estimation of the sampling uncertainty. These two computations were run on several different 'typical' contamination measurement scenarios [200 liter drums, 27 cubic meter 'truck' containers, 0.01-10 liter 'laboratory' containers, and 3600 square meter soil 'in-situ' plots]. In all cases examined, the sampling uncertainty was larger than the in-toto gamma measurement uncertainty - typically about an order of magnitude larger. This means that in-toto measurements are likely better for situations where the activity is not homogeneous, and where gamma spectroscopy is appropriate. If sampling is to be done, then the best results will be when the largest mass of sample is extracted and when it is made up from the largest number of discrete sub-samples. The more extreme the non-uniformity, the more important this is. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Considerations and Lessons Learned from the Use of Gamma Spectroscopy Systems at FUSRAP Project Sites - 17459

This paper will discuss the application of gamma spectroscopy systems for analysis of environmental media samples for parents and daughter progeny of the Natural Uranium and Thorium Decay Series radionuclides. The concentrations and relative ratios of naturally occurring isotopes are used to confirm the presence of FUSRAP-related wastes and for understanding the associated potential dose and health risks. Focus will be given to lessons learned from the set-up and operation of onsite gamma spectroscopy laboratories used to provide stakeholders with defensible and timely results to support FUSRAP site investigations and remediation including adaptive survey design implementation, physical remediation and waste transport, and confirmatory final status survey activities. This paper focuses on the potential impacts to gamma spectroscopy measurement accuracy from the following: - Bias caused by sample matrix effects as well as use of different library reference values between performance evaluation study providers and testing laboratories; - Use of calibration sources with limited energy ranges, and; - Selection of available alternative isotopic decay reference data for the input of line energies and their intensities. These lessons learned include discussing how inter-laboratory measurement differences from blind performance evaluation samples are affected by the manufacturer's measurement method, including equilibrium assumptions; the isotope decay information source library used by the study provider and participating laboratories; and calibration source geometry/density variances from actual sample conditions. Any of these factors can significantly impact the accuracy of reported results data. Deepening the reader's understanding of the various factors that impact the accuracy, interpretation, and overall usability of gamma spectroscopy results data from laboratories will help ensure defensible decision-making and cost-effective mission implementation within FUSRAP and similar remediation programs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FTIR and Raman Spectroscopy of Reduced Graphene Oxide Carbon Nanoribbons and Graphene Oxide on Copper (Cu)

In the past couple of decades, carbon nanomaterials produced from graphene and graphite have emerged as one of the more important recently discovered substances. These carbon nanomaterials have been found to exhibit high levels of mechanical strength, thermal resistance, and electrical conductivity, thus having a multitude of applications. Therefore, it is important to identify and analyze their traits in order to maximize their effectiveness. Two spectroscopic techniques employed for such analyses of these materials are Fourier-Transform Infrared (FTIR) and Raman Spectroscopy. The advantages of FTIR and Raman include nondestructive analysis, relatively quick measurements under normal atmospheric conditions, and enhanced sensitivity with high resolution capacity. FTIR Spectroscopy was used in this research project to determine the effects of thermal exfoliation and photoreduction on the functionality groups of a carbon nanomaterial. Raman Spectroscopy was used in this research project to determine the effects of thermal exfoliation and photoreduction on the intensity of the disorder peak, which is greater in intensity if the carbon nanomaterial exhibits greater amounts of functionalities or defects in the graphitic material. There were two sample types which were analyzed with both FTIR and Raman Spectroscopy for the research project: graphene nanoribbons and graphene oxide. The m-grade graphene nanoribbons (GNRs) were produced from m-grade carbon nanotubes (CNTs) via Tour's method. The graphene oxide (GO) was produced from graphene via Tour's method, sonicated and centrifuged, dip-coated onto Copper (Cu) foil, and then photoreduced under a UV light source. FTIR measurements and analyses were conducted using a Jasco FTIR Spectrometer. Raman measurements and analyses were conducted using a Jasco Laser Raman Spectrometer. Tasks and techniques for this project included photoreduction, dip-coating, corrosion testing, FTIR and Raman data collection and analysis, and improvement of data collection for the Raman Spectrometer. GNRs exfoliated and reduced (deoxygenation) at 270 deg. C in air showed a significant decrease in O functionalities according to FTIR. However, Raman revealed that a large increase in graphene planar and edge defects are present as indicated by the disorder band at 1340 cm-1. Further optimization could be performed by thermal exfoliation at lower temperatures assuming a need for fewer structural defects. Graphene oxide coatings showed clear reduction with an increase with photoreduction time. Raman revealed that the reduced graphene oxide films had less disruption in the planar phonon lattice vibrations which indicates that the structure is returning to sp2 hybridization of pristine graphene without adding structural defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ Monitoring of Lanthanide Reactions with Oxide Species via Combined Absorption Spectroscopy and Electrochemical Methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

absorption spectroscopy↗

Using GPU Programming for Inverse Spectroscopy

The Idaho National Laboratory (INL) has developed a detector that relies heavily on computationally expensive inverse spectroscopy algorithms to determine probabilistic three dimensional mappings of the source and its intensity. This inverse spectroscopy algorithm applies to material accountability due to the potential to determine where nuclear sources are present as a function of time and space. And yet because the novel algorithm can become prohibitively expensive on a standard desktop PC, the INL has incorporated new hardware from the commercial graphics community. General programming for graphics processing units (GPUs) is not a new concept. However, the application of GPUs to evidence theory-based inverse spectroscopy is both novel and particularly apropos. Improvements while using a (slightly upgraded) standard PC are approximately three orders of magnitude, making a ten hour computation in less than four seconds. This significantly changes the concept of prohibitively expensive calculations and makes application to materials accountability possible in near real time. Indeed, the sensor collection time is now expected to dominate the time required to determine the source and its intensity, instead of the inverse spectroscopy method.

97 MATHEMATICS AND COMPUTING↗

High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

47 OTHER INSTRUMENTATION↗

Electronic and magnetic structure of RScO{sub 3} (R=Sm,Gd,Dy) from x-ray spectroscopies and first-principles calculations

The electronic structures of SmScO{sub 3}, GdScO{sub 3}, and DyScO{sub 3} are investigated by means of x-ray photoelectron spectroscopy, x-ray emission spectroscopy (XES), and x-ray absorption spectroscopy (XAS). A strong hybridization between Sc 3d and O 2p is found, and a contribution of the rare-earth 5d states to this hybridization is not excluded. The band gaps of the compounds are determined by combining XES and XAS measurements. For SmScO{sub 3}, GdScO{sub 3}, and DyScO{sub 3} the band gaps were determined to be 5.6, 5.8, and 5.9 eV, respectively. Magnetization versus temperature measurements reveal antiferromagnetic coupling at 2.96 (SmScO{sub 3}), 2.61 (GdScO{sub 3}), and 3.10 K (DyScO{sub 3}). For DyScO{sub 3} a Rietveld refinement of a 2 K neutron-diffraction data set gives the spin arrangement of Dy in the Pbnm structure (Shubnikov group: Pb{sup '}n{sup '}m{sup '})

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relationship between ferroelectric properties and local structure of Pb{sub 1−x}Ba{sub x}Zr{sub 0.40}Ti{sub 0.60}O{sub 3} ceramic materials studied by X-ray absorption and Raman spectroscopies

This paper reports on the structural characterization of Pb{sub 1−x}Ba{sub x}Zr{sub 0.40}Ti{sub 0.60}O{sub 3} (PBZT) ferroelectric ceramic compositions prepared by the conventional solid state reaction method. X-ray absorption spectroscopy (XAS) and Raman spectroscopy were used in the probing of the local structure of PBZT samples that exhibit a normal or relaxor ferroelectric behavior. They showed a considerable local disorder around Zr and Pb atoms in the samples of tetragonal or cubic long-range order symmetry. The intensity of the E(TO{sub 3}) mode in the Raman spectra of PBZT relaxor samples remains constant at temperatures lower than T{sub m}, which has proven the stabilization of the correlation process between nanodomains. - Graphical abstract: X-ray absorption measurements showed considerable local disorder around Zr and Pb atoms in the samples of tetragonal or cubic long-range order symmetry. The intensity of the E(TO{sub 3}) mode in the Raman spectra of PBZT relaxor samples remains constant at temperatures lower than T{sub m}, which has proven the stabilization of the correlation process between nanodomains. Display Omitted - Highlights: • Structural characterization of Pb{sub 1−x}Ba{sub x}Zr{sub 0.40}Ti{sub 0.60}O{sub 3} (PBZT) ferroelectric ceramic. • X-ray absorption and Raman spectroscopies were used to probe the structure of PBZT. • Dissymmetry of Zr and Pb sites was observed in samples long-range cubic symmetry. • Local disorder in all PBZT samples through the observation of Raman active modes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined electron microscopy and spectroscopy characterization of as-received, acid purified, and oxidized HiPCO single-wall carbon nanotubes

Single-wall carbon nanotubes (SWCNTs) are very important materials due to their combination of unique structure, dimension, strength, chemical stability, and electronic properties. Nevertheless, SWCNTs from commercial sources usually contain several impurities, which are usually removed by a purification process that includes reflux in acids and strong oxidation. This strong chemical procedure may alter the nanotube properties and it is thus important to control the extent of functionalization and oxidation during the purification procedure. In this report, we provide a comprehensive study of the structure and physical composition of SWCNTs during each step of the purification process. Techniques such as Raman spectroscopy, transmission electron microscopy, scanning electron microscopy, thermogravimetric analysis, X-ray photoelectron spectroscopy and Infrared spectroscopy were used to track the SWCNTs structure, in terms of length and diameter distribution, and surface chemical modifications during each purification stage.

36 MATERIALS SCIENCE↗

Mass-Analyzed Threshold Ionization (MATI) Spectroscopy of Atoms and Molecules using VUV Synchrotron Radiation

Mass-analyzed threshold ionization (MATI) spectroscopy using synchrotron radiation (Advanced Light Source, Lawrence Berkeley National Laboratory) has been performed for Ar, N2, O2, N2O, H2O, C2H2, and C6H6. MATI allows for a better determination of ionization energies compared to those derived from photoionization efficiency curves traditionally used in synchrotron photoionization mass spectrometry. The separation of the long-lived Rydberg state from the directly-formed prompt ion, essential for a meaningful MATI spectrum, has been accomplished by employing an arrangement of ion optics coupled to unique electric-field pulsing schemes. For Ar, a number of resolved bands below the ionization energy are observed, and these are ascribed to high-n,l Rydberg states prepared in the MATI scheme. The first vibrational stateresolved MATI spectra of N2 and O2 are reported and spectral characteristics are discussed in comparison with previously-reported threshold photoelectron spectroscopic studies. While MATI performed with synchrotron radiation is intrinsically less sensitive compared to laser based sources, this work demonstrates that MATI spectroscopy performed with widely tunable VUV radiation is a complementary technique for studying the ionization spectroscopy of polyatomic molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoelectron Spectroscopy of C 60 F n - and C 60 F m 2- (n=17,33,35,43,45,47;m=34,46) in the Gas Phase and the Generation and Characterization of C 1 -C 60 F 47 - and D 2 -C 60 F 44 in Solution

A photoelectron spectroscopy investigation of the fluorofullerene anions C 60 F n - (n = 17, 33, 35, 43, 45, 47) and the doubly-charged anions C 60 F 34 2- and C 60 F 46 2- is reported. The electron affinities for the corresponding neutral molecules, C 60 F n , were directly measured and were found to increase as n increased, reaching the extremely high value of 5.66 ± 0.10 eV for C 60 F 47 . Density functional calculations suggest that the experimentally observed species C 60 F 17 - , C 60 F 35 - , and C 60 F 47 - were each formed by reductive-defluorination of the parent fluorofullerene, C 3v -C 60 F 18 , C 60 F 36 (a mixture of isomers), and D 3 -C 60 F 48 , respectively, without rearrangement of the remaining fluorine atoms. The DFT-predicted stability of C 60 F 47 - was verified by its generation by chemical reduction from D 3 -C 60 F 48 in chloroform solution at 25 °C and its characterization by mass spectrometry and 19 F NMR spectroscopy. Further reductive-defluorination of C 60 F 47 - in solution resulted in the selective generation of a new fluorofullerene, D 2 -C 60 F 44 , which was also characterized by mass spectrometry and 19 F NMR spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic structure of N,N'-ethylene-bis(1,1,1-trifluoropentane-2,4- dioneiminato)-copper(II) (Cu-TFAC), from soft X-ray spectroscopies and density functional theory calculations

The element and orbital-specific electronic structure of thin films of the organic material N,N'-ethylene-bis(1,1,1-trifluoropentane-2,4-dioneiminato)-copper(II) (designated as Cu-TFAC) has been studied using a combination of synchrotron radiation-excited resonant X-ray emission spectroscopy, X-ray photoelectron spectroscopy, X-ray absorption spectroscopy and density functional theory calculations. Furthermore, resonant X-ray emission at the carbonK-edge was used to measure the density of states for individual C sites in the molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic Structure of In2O3 from Resonant X-ray Emission Spectroscopy

The valence and conduction band structures of In2O3 have been measured using a combination of valence band x-ray photoemission spectroscopy, O K-edge resonant x-ray emission spectroscopy, and O K-edge x-ray absorption spectroscopy. Excellent agreement is noted between the experimental spectra and O 2p partial density of states calculated within hybrid density functional theory. Our data are consistent with a direct band gap for In2O3.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗