Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard deviation modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Future Projections of the Large-Scale Meteorology Associated with California Heat Waves in CMIP5 Models

Previous work showed that climate models capture historical large-scale meteorological patterns (LSMPs) associated with California Central Valley heat waves including both ways these heat waves form. This work examines what models predict under the Representative Concentration Pathway (RCP) 4.5 and RCP8.5 scenarios. Model performance varies, so a multimodel average weights each model based on its historical performance in four parameters. An LSMP index (LSMPi) defined using upper atmosphere variables captures dates of past extreme surface temperature maxima. LSMPi correlates well with all values of California Central Valley-average surface maximum temperature. LSMPi distributions in future simulations shift ~0.6 standard deviations higher between 1961–2000 and 2061–2100 for RCP8.5 data. Based on the historical climatology, future scenarios show a large increase in the frequency and duration of heat waves in every model. Four times as many heat waves occur and their median duration doubles, using historical thresholds. Of the two ways heat waves form, Type 1 has similar frequency in the future. But, Type 2 becomes much more common because Type 2 has a preexisting hot anomaly in Southwestern Canada, much like the historical to future climatological change in that region (a “global warming” signal). The 20-year return value anomaly increases by 30–40%. The average of the 50 hottest temperatures increases 3.5–6 K depending on the scenario. When extreme values are defined using the future climatology, the models and their average have no consistent increase or decrease of distribution properties such as shape, scale, and return values of the extremes compared to historical values.

54 ENVIRONMENTAL SCIENCES↗

Planck 2015 results: XXIV. Cosmology from Sunyaev-Zeldovich cluster counts

In this work, we present cluster counts and corresponding cosmological constraints from the Planck full mission data set. Our catalogue consists of 439 clusters detected via their Sunyaev-Zeldovich (SZ) signal down to a signal-to-noise ratio of 6, and is more than a factor of 2 larger than the 2013 Planck cluster cosmology sample. The counts are consistent with those from 2013 and yield compatible constraints under the same modelling assumptions. Taking advantage of the larger catalogue, we extend our analysis to the two-dimensional distribution in redshift and signal-to-noise. We use mass estimates from two recent studies of gravitational lensing of background galaxies by Planck clusters to provide priors on the hydrostatic bias parameter, (1-b). In addition, we use lensing of cosmic microwave background (CMB) temperature fluctuations by Planck clusters as an independent constraint on this parameter. These various calibrations imply constraints on the present-day amplitude of matter fluctuations in varying degrees of tension with those from the Planck analysis of primary fluctuations in the CMB; for the lowest estimated values of (1-b) the tension is mild, only a little over one standard deviation, while it remains substantial (3.7σ) for the largest estimated value. We also examine constraints on extensions to the base flat ΛCDM model by combining the cluster and CMB constraints. The combination appears to favour non-minimal neutrino masses, but this possibility does little to relieve the overall tension because it simultaneously lowers the implied value of the Hubble parameter, thereby exacerbating the discrepancy with most current astrophysical estimates. In conclusion, improving the precision of cluster mass calibrations from the current 10%-level to 1% would significantly strengthen these combined analyses and provide a stringent test of the base ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Discrete flavor symmetry and minimal seesaw mechanism

This work proposes a neutrino mass model that is derived using the minimal seesaw mechanism, which contains only two right-handed neutrinos, under the non-Abelian discrete flavor symmetry S{sub 4} x Z{sub 2}. Two standard model doublets, L{sub {mu}} and L{sub {tau}}, are assigned simultaneously to a 2 representation of S{sub 4}. When the scalar fields introduced in this model, in addition to the standard model Higgs, and the leptons are coupled within the symmetry, the seesaw mechanism results in the tribimaximal neutrino mixing. This study examined the possible deviations from tribimaximal mixing related to the experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Redshift drift in an inhomogeneous universe: averaging and the backreaction conjecture

An expression for the average redshift drift in a statistically homogeneous and isotropic dust universe is given. The expression takes the same form as the expression for the redshift drift in FLRW models. It is used for a proof-of-principle study of the effects of backreaction on redshift drift measurements by combining the expression with two-region models. The study shows that backreaction can lead to positive redshift drift at low redshifts, exemplifying that a positive redshift drift at low redshifts does not require dark energy. Moreover, the study illustrates that models without a dark energy component can have an average redshift drift observationally indistinguishable from that of the standard model according to the currently expected precision of ELT measurements. In an appendix, spherically symmetric solutions to Einstein's equations with inhomogeneous dark energy and matter are used to study deviations from the average redshift drift and effects of local voids.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OBSERVATIONS OF SOLAR ENERGETIC PARTICLES FROM {sup 3}He-RICH EVENTS OVER A WIDE RANGE OF HELIOGRAPHIC LONGITUDE

A prevailing model for the origin of {sup 3}He-rich solar energetic particle (SEP) events attributes particle acceleration to processes associated with the reconnection between closed magnetic field lines in an active region and neighboring open field lines. The open field from the small reconnection volume then provides a path along which accelerated particles escape into a relatively narrow range of angles in the heliosphere. The narrow width (standard deviation <20 Degree-Sign ) of the distribution of X-ray flare longitudes found to be associated with {sup 3}He-rich SEP events detected at a single spacecraft at 1 AU supports this model. We report multispacecraft observations of individual {sup 3}He-rich SEP events that occurred during the solar minimum time period from 2007 January through 2011 January using instrumentation carried by the two Solar Terrestrial Relations Observatory spacecraft and the Advanced Composition Explorer. We find that detections of {sup 3}He-rich events at pairs of spacecraft are not uncommon, even when their longitudinal separation is >60 Degree-Sign . We present the observations of the {sup 3}He-rich event of 2010 February 7, which was detected at all three spacecraft when they spanned 136 Degree-Sign in heliographic longitude. Measured fluences of {sup 3}He in this event were found to have a strong dependence on longitude which is well fit by a Gaussian with standard deviation {approx}48 Degree-Sign centered at the longitude that is connected to the source region by a nominal Parker spiral magnetic field. We discuss several mechanisms for distributing flare-accelerated particles over a wide range of heliographic longitudes including interplanetary diffusion perpendicular to the magnetic field, spreading of a compact cluster of open field lines between the active region and the source surface where the field becomes radial and opens out into the heliosphere, and distortion of the interplanetary field by a preceding coronal mass ejection. Statistical studies of additional {sup 3}He-rich events detected at multiple spacecraft will be needed to establish the relative importance of the various mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Model-Independent Evidence for J / ψ p Contributions to Λ b 0 → J / ψ p K – Decays

The data sample of Λ 0 b → J/ψpK - decays acquired with the LHCb detector from 7 and 8 TeV pp collisions, corresponding to an integrated luminosity of 3 fb -1 , is inspected for the presence of J/ψp or J/ψK - contributions with minimal assumptions about K - p contributions. It is demonstrated at more than nine standard deviations that Λ 0 b → J/ψpK - decays cannot be described with K - p contributions alone, and that J/ψp contributions play a dominant role in this incompatibility. These model-independent results support the previously obtained model-dependent evidence for P + c → J/ψp charmonium-pentaquark states in the same data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MEASUREMENTS OF THE SOFT GAMMA-RAY EMISSION FROM SN2014J WITH SUZAKU

The hard X-ray detector (HXD) on board Suzaku measured soft γ -rays from the SN Ia SN2014J at 77 ± 2 days after the explosion. Although the confidence level of the signal is about 90% (i.e., 2 σ ), the 3 σ upper limit has been derived at <2.2 × 10{sup −4} ph s{sup −1} cm{sup −2} in the 170–250 keV band as the first independent measurement of soft γ -rays with an instrument other than INTEGRAL . For this analysis, we have examined the reproducibility of the NXB model of HXD/GSO using blank sky data. We find that the residual count rate in the 90–500 keV band is distributed around an average of 0.19% with a standard deviation of 0.42% relative to the NXB rate. The averaged residual signals are consistent with that expected from the cosmic X-ray background. The flux of SN2014J derived from Suzaku measurements taken in one snapshot at t = 77 ± 2 days after the explosion is consistent with the INTEGRAL values averaged over the period between t = 50 and 100 days and also with explosion models of single or double degenerate scenarios. Being sensitive to the total ejecta mass surrounding the radioactive material, the ratio between continuum and line flux in the soft gamma-ray regime might distinguish different progenitor models. The Suzaku data have been examined with this relation at t = 77 ± 2 days, but could not distinguish models between single and double degenerate-progenitors. We disfavor explosion models with larger {sup 56}Ni masses than 1 M {sub ⊙}, from our 1 σ error on the 170–250 keV X-ray flux of (1.2 ± 0.7) × 10{sup −4} ph s{sup −1} cm{sup −2}.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for a new resonance decaying into two spin-0 bosons in a final state with two photons and two bottom quarks in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search for a new boson X is presented using CERN LHC proton-proton collision data collected by the CMS experiment at $\sqrt{s}$ = 13 TeV in 2016–2018, and corresponding to an integrated luminosity of 138 fb -1 . The resonance X decays into either a pair of Higgs bosons HH of mass 125 GeV or an H and a new spin-0 boson Y. One H subsequently decays to a pair of photons, and the second H or Y, to a pair of bottom quarks. The explored mass ranges of X are 260–1000 GeV and 300–1000 GeV, for decays to HH and to HY, respectively, with the Y mass range being 90–800 GeV. For a spin-0 X hypothesis, the 95% confidence level upper limit on the product of its production cross section and decay branching fraction is observed to be within 0.90–0.04 fb, depending on the masses of X and Y. The largest deviation from the background-only hypothesis with a local (global) significance of 3.8 (below 2.8) standard deviations is observed for X and Y masses of 650 and 90 GeV, respectively. The limits are interpreted using several models of new physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-Phase Fluid Flow Properties of Rough Fractures With Heterogeneous Wettability: Analysis With Lattice Boltzmann Simulations

Fractures are conduits for fluid flow in low-permeability geological formations. Multiphase flow properties of fractures are important in natural processes and in engineering applications such as the evaluation of the sealing capacity of caprocks and productivity of hydrocarbon-bearing tight rocks. Investigations of flow and transport through fractures typically focus on the effects of fracture geometric and mechanical factors such as aperture, roughness, and compressibility. The wettability of the fracture surfaces and its influence on microscale interfacial phenomena and macroscale effective transport properties are seldom studied. In this study, we investigated the effect of heterogeneous wetting properties on the displacement of water by supercritical CO2 through a series of lattice Boltzmann method simulations. The results show the evolution of the CO2 plume within a fracture is controlled by both the roughness of the aperture field and the wetting distribution. We combined these factors into a capillary pressure map that can be related to the macroscopic flow behavior of the fracture. We observed that heterogeneous wetting distributions promote the residual trapping of water where lower capillary pressures allowed for isolated water pockets in higher capillary pressure zones. Analysis of fracture unsteady relative permeability shows the effect of wetting on permeability evolution and provides support for the viscous-coupling relative permeability model. Finally, analysis of the steady-state relative permeability and saturation demonstrates a strong correlation between permeability and the standard deviation of the capillary pressure field. Thus, characterizing the distribution of wetting properties of fractures is crucial to understanding multiphase fracture flow and transport properties.

58 GEOSCIENCES↗

Accurate simulation of surfaces and interfaces of ten FCC metals and steel using Lennard–Jones potentials

Abstract The earlier integration of validated Lennard–Jones (LJ) potentials for 8 fcc metals into materials and biomolecular force fields has advanced multiple research fields, for example, metal–electrolyte interfaces, recognition of biomolecules, colloidal assembly of metal nanostructures, alloys, and catalysis. Here we introduce 12-6 and 9-6 LJ parameters for classical all-atom simulations of 10 further fcc metals (Ac, Ca (α), Ce (γ), Es (β), Fe (γ), Ir, Rh, Sr (α), Th (α), Yb (β)) and stainless steel. The parameters reproduce lattice constants, surface energies, water interfacial energies, and interactions with (bio)organic molecules in 0.1 to 5% agreement with experiment, as well as qualitative mechanical properties under standard conditions. Deviations are reduced up to a factor of one hundred in comparison to earlier Lennard–Jones parameters, embedded atom models, and density functional theory. We also explain a quantitative correlation between atomization energies from experiments and surface energies that supports parameter development. The models are computationally very efficient and applicable to an exponential space of alloys. Compatibility with a wide range of force fields such as the Interface force field (IFF), AMBER, CHARMM, COMPASS, CVFF, DREIDING, OPLS-AA, and PCFF enables reliable simulations of nanostructures up to millions of atoms and microsecond time scales. User-friendly model building and input generation are available in the CHARMM-GUI Nanomaterial Modeler. As a limitation, deviations in mechanical properties vary and are comparable to DFT methods. We discuss the incorporation of reactivity and features of the electronic structure to expand the range of applications and further increase the accuracy.

Kanhaiya, Krishan (ORCID:0000000236222655)↗

The vertical-velocity skewness in the atmospheric boundary layer without buoyancy and Coriolis effects

One of the main features of near-neutral atmospheric boundary layer (ABL) turbulence is the positive vertical velocity skewness $Sk_w$ above the roughness sublayer or the buffer region in smooth-walls. The $Sk_w$ variations are receiving renewed interest in many climate-related parameterizations of the ABL given their significance to cloud formation and to testing sub-grid schemes for Large Eddy Simulations (LES). The vertical variations of $Sk_w$ are explored here using wind tunnel and flume experiments collected above smooth, rough, and permeable-walls in the absence of buoyancy and Coriolis effects. These laboratory experiments form a necessary starting point to probe the canonical structure of $Sk_w$ as they deal with a key limiting case (i.e., near-neutral conditions). Diagnostic models based on cumulant expansions, realizability constraints, and constant mass flux approach routinely employed in the convective boundary layer as well as prognostic models based on third-order budgets are used to explain variations in $Sk_w$ for the idealized laboratory conditions. The failure of flux-gradient relations to model $Sk_w$ from the gradients of the vertical velocity variance σ$_w^2$ are explained and corrections based on models of energy transport offered. Novel links between the diagnostic and prognostic models are also featured, especially for the inertial term in the third-order budget of the vertical velocity fluctuation. The co-spectral properties of w′/σ w vs w′ 2 /σ$_w^2$ are also presented for the first time to assess the dominant scales governing $Sk_w$ in the inner and outer layers, where w′ is the fluctuating vertical velocity and σ w is the vertical velocity standard deviation.>

Boundary layer flow↗

CHARACTERIZING THE RADIO-X-RAY CONNECTION IN GRS 1915+105

We analyzed radio and X-ray observations of GRS 1915+105, between 1995 May and 2006 June, focusing on the times characterized by radio flares and cycles of hard dips-soft spikes in the X-ray light curve. Assuming these flares to be discrete ejections, we applied a plasmon model to the radio data, with good agreement with the light curves. We fitted a total of 687 radio flares with a standard model of a plasmon. We found that the distribution of width is t{sub 0} = 1160 s with an rms deviation of 360 s, while that of the amplitude is S {sub max} = 59 mJy with an rms deviation of 28 mJy. The distribution of width is thus rather peaked, while that of the amplitude is not. Regarding radio and X-ray links, this study confirms previous observations on smaller data sets, namely that X-ray cycles of hard dips-soft spikes are always followed by radio flares. A strong correlation is found between the length of X-ray 'dips' in the X-ray light curves and the amplitude and fluence of the subsequent radio oscillations. A model of an exponential rise of the form L{sub 15GHz}({Delta}t) = L {sub max}(1 - exp(-({Delta}t - {Delta}t{sub min})/{tau}) is in good agreement with the observations, with the maximum fluence L{sub max} on the order of 70 Jy s, and the characteristic time {tau} on the order of 200-500 s. We discuss possible physical interpretations of this correlation, regarding the nature of the ejected material and the physical process responsible for the ejection.

79 ASTRONOMY AND ASTROPHYSICS↗

Evidence for direct CP violation in the decay B{sup {+-}{yields}D(*)}K{sup {+-}}, D{yields}K{sub S}{sup 0{pi}+{pi}-} and measurement of the CKM phase {phi}{sub 3}

We present a new measurement of the unitarity triangle angle {phi}{sub 3} using a Dalitz plot analysis of the K{sub S}{sup 0{pi}+{pi}-} decay of the neutral D meson produced in B{sup {+-}{yields}D(*)}K{sup {+-}} decays. The method exploits the interference between D{sup 0} and D{sup 0} to extract the angle {phi}{sub 3}, strong phase {delta}, and the ratio r of suppressed and allowed amplitudes. We apply this method to a 605 fb{sup -1} data sample collected by the Belle experiment. The analysis uses three decays: B{sup {+-}{yields}D}K{sup {+-}}, and B{sup {+-}{yields}D}*K{sup {+-}}with D*{yields}D{pi}{sup 0} and D*{yields}D{gamma}, as well as the corresponding charge-conjugate modes. From a combined maximum likelihood fit to the three modes, we obtain {phi}{sub 3}=78.4 deg. (+10.8 deg./-11.6 deg.){+-}3.6 deg. (syst){+-}8.9 deg. (model). CP conservation in this process is ruled out at the confidence level (1-CL)=5x10{sup -4}, or 3.5 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-G-BRD-01: A Data-Driven 4D-MRI Motion Model to Estimate Full Field-Of-View Abdominal Motion From 2D Image Navigators During MR-Linac Treatment

Purpose: To estimate full field-of-view abdominal respiratory motion from fast 2D image navigators using a 4D-MRI based motion model. This will allow for radiation dose accumulation mapping during MR-Linac treatment. Methods: Experiments were conducted on a Philips Ingenia 1.5T MRI. First, a retrospectively ordered 4D-MRI was constructed using 3D transient-bSSFP with radial in-plane sampling. Motion fields were calculated through 3D non-rigid registration. From these motion fields a PCA-based abdominal motion model was constructed and used to warp a 3D reference volume to fast 2D cine-MR image navigators that can be used for real-time tracking. To test this procedure, a time-series consisting of two interleaved orthogonal slices (sagittal and coronal), positioned on the pancreas or kidneys, were acquired for 1m38s (dynamic scan-time=0.196ms), during normal, shallow, or deep breathing. The coronal slices were used to update the optimal weights for the first two PCA components, in order to warp the 3D reference image and construct a dynamic 4D-MRI time-series. The interleaved sagittal slices served as an independent measure to test the model’s accuracy and fit. Spatial maps of the root-mean-squared error (RMSE) and histograms of the motion differences within the pancreas and kidneys were used to evaluate the method. Results: Cranio-caudal motion was accurately calculated within the pancreas using the model for normal and shallow breathing with an RMSE of 1.6mm and 1.5mm and a histogram median and standard deviation below 0.2 and 1.7mm, respectively. For deep-breathing an underestimation of the inhale amplitude was observed (RMSE=4.1mm). Respiratory-induced antero-posterior and lateral motion were correctly mapped (RMSE=0.6/0.5mm). Kidney motion demonstrated good motion estimation with RMSE-values of 0.95 and 2.4mm for the right and left kidney, respectively. Conclusion: We have demonstrated a method that can calculate dynamic 3D abdominal motion in a large volume, while acquiring real-time cine-MR images for MR-guided radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-362: Quantification and Modelling of the Ionization Chamber Simulation Effective Points On Monaco Treatment Planning System

Purpose: Because of statistical noise in Monte Carlo dose calculations, effective point doses may not be accurate. Volume spheres are useful for evaluating dose in Monte Carlo plans, which have an inherent statistical uncertainty.We use a user-defined sphere volume instead of a point, take sphere sampling around effective point make the dose statistics to decrease the stochastic errors. Methods: Direct dose measurements were made using a 0.125cc Semiflex ion chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW, Germany).In the scanned CT phantom series the sensitive volume length of the IC (6.5mm) were delineated and defined the isocenter as the simulation effective points. All beams were simulated in Monaco in accordance to the measured model. In our simulation using 2mm voxels calculation grid spacing and choose calculate dose to medium and request the relative standard deviation ≤0.5%. Taking three different assigned IC over densities (air electron density(ED) as 0.01g/cm3 default CT scanned ED and Esophageal lumen ED 0.21g/cm3) were tested at different sampling sphere radius (2.5, 2, 1.5 and 1 mm) statistics dose were compared with the measured does. Results: The results show that in the Monaco TPS for the IC using Esophageal lumen ED 0.21g/cm3 and sampling sphere radius 1.5mm the statistical value is the best accordance with the measured value, the absolute average percentage deviation is 0.49%. And when the IC using air electron density(ED) as 0.01g/cm3 and default CT scanned EDthe recommented statistical sampling sphere radius is 2.5mm, the percentage deviation are 0.61% and 0.70%, respectivly. Conclusion: In Monaco treatment planning system for the ionization chamber 31010 recommend air cavity using ED 0.21g/cm3 and sampling 1.5mm sphere volume instead of a point dose to decrease the stochastic errors. Funding Support No.C201505006.

60 APPLIED LIFE SCIENCES↗

Appalachian Basin Temperature-Depth Maps and Structured Data in support of Feasibility Study of Direct District Heating for the Cornell Campus Utilizing Deep Geothermal Energy

This dataset contains shapefiles and rasters that summarize the results of a stochastic analysis of temperatures at depth in the Appalachian Basin states of New York, Pennsylvania, and West Virginia. This analysis provides an update to the temperature-at-depth maps provided in the Geothermal Play Fairway Analysis of the Appalachian Basin (GPFA-AB) Thermal Quality Analysis (GDR repository 879: https://gdr.openei.org/submissions/879). This dataset improves upon the GPFA-AB dataset by considering several additional uncertainties in the temperature-at-depth calculations, including geologic properties and thermal properties. A Monte Carlo analysis of these uncertain properties and the GPFA-AB estimated surface heat flow was used to predict temperatures at depth using a 1-D heat conduction model. In this data submission, temperatures are provided for depths from 1-5 km in 0.5 km increments. The mean, standard deviation, and selected quantiles of temperatures at these depths are provided as shapefiles with attribute tables that contain the data. Rasters are provided for the mean and standard deviation data. Figures and maps that summarize the data are also provided. For the pixel corresponding to Cornell University, Ithaca, NY, a .csv file containing the 10,000 temperature-depth profiles estimated from the Monte Carlo analysis is provided. These data are summarized in a figure containing violin plots that illustrate the probability of obtaining certain temperatures at depths below Cornell.

15 GEOTHERMAL ENERGY↗

Joint Seasonal ARMA Approach for Modeling of Load Forecast Errors in Planning Studies

To make informed and robust decisions in the probabilistic power system operation and planning process, it is critical to conduct multiple simulations of the generated combinations of wind and load parameters and their forecast errors to handle the variability and uncertainty of these time series. In order for the simulation results to be trustworthy, the simulated series must preserve the salient statistical characteristics of the real series. In this paper, we analyze day-ahead load forecast error data from multiple balancing authority locations and characterize statistical properties such as mean, standard deviation, autocorrelation, correlation between series, time-of-day bias, and time-of-day autocorrelation. We then construct and validate a seasonal autoregressive moving average (ARMA) model to model these characteristics, and use the model to jointly simulate day-ahead load forecast error series for all BAs.

Power system planning, Operations, Probabilistic m↗