Search NASA⌕ Search

SEARCH · Search NASA

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Studies of Nuclear Structure Related to an Induced Depletion of Isomers

Nuclear isomers have served as important touchstones in the development of nuclear models. In addition, those metastable excited states whose lifetimes reach decades or longer present intriguing possibilities as high-energy-density media. Together, these aspects have motivated considerable research on whether some isomeric nuclides might allow an induced release of the stored energy upon demand. Targeted studies of nuclear structure aimed at this question are a rather recent development, providing a parallel approach to direct tests of induced depletion on isomeric samples. This paper will discuss the relationship between these dual research tracks, as exemplified by experiments conducted on isomeric nuclei in {sup 108}Ag, {sup 178}Hf and {sup 180}Ta.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-A-9A-02: BEST IN PHYSICS (THERAPY) - 4D IMRT Planning Using Highly- Parallelizable Particle Swarm Optimization

Purpose: We present a particle swarm optimization (PSO)-based 4D IMRT planning technique designed for dynamic MLC tracking delivery to lung tumors. The key idea is to utilize the temporal dimension as an additional degree of freedom rather than a constraint in order to achieve improved sparing of organs at risk (OARs). Methods: The target and normal structures were manually contoured on each of the ten phases of a 4DCT scan acquired from a lung SBRT patient who exhibited 1.5cm tumor motion despite the use of abdominal compression. Corresponding ten IMRT plans were generated using the Eclipse treatment planning system. These plans served as initial guess solutions for the PSO algorithm. Fluence weights were optimized over the entire solution space i.e., 10 phases × 12 beams × 166 control points. The size of the solution space motivated our choice of PSO, which is a highly parallelizable stochastic global optimization technique that is well-suited for such large problems. A summed fluence map was created using an in-house B-spline deformable image registration. Each plan was compared with a corresponding, internal target volume (ITV)-based IMRT plan. Results: The PSO 4D IMRT plan yielded comparable PTV coverage and significantly higher dose—sparing for parallel and serial OARs compared to the ITV-based plan. The dose-sparing achieved via PSO-4DIMRT was: lung Dmean = 28%; lung V20 = 90%; spinal cord Dmax = 23%; esophagus Dmax = 31%; heart Dmax = 51%; heart Dmean = 64%. Conclusion: Truly 4D IMRT that uses the temporal dimension as an additional degree of freedom can achieve significant dose sparing of serial and parallel OARs. Given the large solution space, PSO represents an attractive, parallelizable tool to achieve globally optimal solutions for such problems. This work was supported through funding from the National Institutes of Health and Varian Medical Systems. Amit Sawant has research funding from Varian Medical Systems, VisionRT Ltd. and Elekta.

60 APPLIED LIFE SCIENCES↗

Recovery Act: Electrochromic Glazing Technology: Improved Performance, Lower Price (Final Report)

The growing dependency of the US on energy imports and anticipated further increases in energy prices reinforce the concerns about meeting the energy demand in the future and one element of a secure energy future is conservation. It is estimated that the buildings sector represents 40% of the US's total energy consumption. And buildings produce as much as one third of the greenhouse gas emissions primarily through fossil fuel usage during their operational phase. A significant fraction of this energy usage is simply due to inefficient window technology. Electrochromic (EC) windows allow electronic control of their optical properties so that the transparency to light can be adjusted from clear to dark. This ability to control the amount of solar energy allowed into the building can be advantageously used to minimize lighting, heating and air conditioning costs. Currently, the penetration of EC windows into the marketplace is extremely small, and consequently there is a huge opportunity for energy savings if this market can be expanded. In order to increase the potential energy savings it is necessary to increase the quantity of EC windows in operation. Additionally, any incremental improvement in the energy performance of each window will add to the potential energy savings. The overall goals of this project were therefore to improve the energy performance and lower the cost of dynamic (EC) smart windows for residential and commercial building applications. This project is obviously of benefit to the public by addressing two major areas: lowering the cost and improving the energy performance of EC glazings. The high level goals for these activities were: (i) to improve the range between the clear and the tinted state, (ii) reduce the price of EC windows by utilizing lower cost materials, (iii) lowering the U-Value, and (iv) ensure the proposed changes have no detrimental effect to the proven durability of the window. SAGE Electrochromics Inc. is the only company in the US which has a track record of producing EC windows, and presently has a small operational factory in Faribault MN which is shipping products throughout the world. There is a much larger factory currently under construction close by. This project was targeted specifically to address the issues outlined above, with a view to implementation on the new high volume manufacturing facility. Each of the Tasks which were addressed in this project is relatively straightforward to implement in this new facility and so the benefits of the work will be realized quickly. The research described here has helped to understand and provide solutions to several interesting and previously unresolved issues of the technology as well as make progress in areas which will have a significant impact on energy saving. In particular several materials improvements have been made, and tasks related to throughput and yield improvements have been completed. All of this has been accomplished without any detrimental effect on the proven durability of the SageGlass EC device. The project was divided into four main areas: 1. Improvement of the Properties of the EC device by material enhancements (Task 2); 2. Reduce the cost of production by improving the efficiency and yields of some key manufacturing processes (Task 3); 3. Further reduce the cost by significant modifications to the structure of the device (Task 4); 4. Ensure the durability of the EC device is not affected by any of the changes resulting from these activities (Task 5). A detailed description of the activities carried out in these areas is given in the following report, along with the aims and goals of the work. We will see that we have completed Tasks 2 and 3 fully, and the durability of the resulting device structure has been unaffected. Some of Task 4 was not carried out because of difficulties with integrating the installation of the required targets into the production coater due to external constraints not related to this project. We will also see that the durability of the devices produced as a result of this work was largely unaffected by the changes made here, and so we can conclude that the objectives of Task 5 have also been fulfilled. As a result, the future production of EC windows has benefited greatly from this work. We anticipate higher volumes and better yields for devices with an improved EC performance from the new high volume manufacturing facility currently under construction at SAGE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system

Purpose: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Methods: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio–caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient’s tumor motion. A substitute target with the patient’s tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors’ QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients’ tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Results: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors and gimbal motion errors in the ExacTrac log analyses (n = 13). Conclusions: The newly developed video image-based QA system, including in-house software, can analyze more than a thousand images (33 frames/s). Positional errors are approximately equivalent to those in ExacTrac log analyses. This system is useful for the visual illustration of the progress of the tracking state and for the quantification of positional accuracy during dynamic tumor tracking irradiation in the Vero4DRT system.

60 APPLIED LIFE SCIENCES↗

Characterization of Radiation Effects and Ion Tracks with Spallation Neutron Probes

Swift heavy ions are typically defined as high-mass charged particles of kinetic energy above ~1 MeV per nucleon (MeV/u). In this regime, the energy deposition of the ions is dominated by electronic stopping, and each individual ion may induce a linear trail of damage with a width of a few nanometers and a length of several tens of micrometers or more. During the last decade, ion tracks and other radiation effects induced by swift heavy ions have been studied in a wide range of materials for basic research, as well as for a wide variety of applications. The interactions of swift heavy ions with matter are significantly different from those induced by lower energy ions (keV-MeV), where atoms are directly displaced from their lattice sites via elastic collisions. In contrast, swift ions (MeV-GeV) transfer their kinetic energy to the electrons of the target, inducing ionization and initiating a cascade of secondary electrons that quickly spreads radially. The extremely high energy densities (up to tens of eV/atom) along the ion path lead to a confined plasma-like state that is dissipated through electron–phonon coupling to the lattice. Further, subsequent rapid transitions through equilibrium and non-equilibrium states trigger complex structural modifications within a highly localized nanoscale damage zone, forming ion tracks in materials ion tracks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A needle guidance system for biopsy and therapy using two-dimensional ultrasound

Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-H-CAMPUS-TeP1-03: Magnetically Focused Proton Irradiation of Small Volume Radiosurgery Targets

Purpose: To investigate the use of magnetic focusing for small volume proton radiosurgery targets using a triplet combination of quadrupole rare earth permanent magnet Halbach cylinder assemblies Methods: Fourteen quadrupole magnets consisting of 24 segments of radiation hard samarium-cobalt adhered into k=3 Halbach cylinders with various field gradients (100 to 250 T/m) were designed and manufactured. Triplet combinations of the magnets were placed on a positioning track on our Gantry 1 treatment table. Unmodulated 127 MeV proton beams with initial diameters of 3 to 20 mm were delivered to a water tank using single-stage scattering. Depth and transverse dose distributions were measured using a PTW PR60020 diode detector and EBT3 film, respectively. This data was compared with unfocused passively collimated beams. Monte Carlo simulations were also performed - both for comparison with experimental data and to further investigate the potential of triplet magnetic focusing. Results: Experimental results using 150 T/m gradient magnets and 15 to 20 mm initial diameter beams show peak to entrance dose ratios that are ∼ 43 to 48 % larger compared with spot size matched 8 mm collimated beams (ie, transverse profile full-widths at 90% maximum dose match within 0.5 mm of focused beams). In addition, the focusing beams were ∼ 3 to 4.4 times more efficient per MU in dose to target delivery. Additional results using different magnet combinations will also be presented. Conclusion: Our results suggest that triplet magnetic focusing could reduce entrance dose and beam number while delivering dose to small (∼≤ 10 mm diameter) radiosurgery targets in less time compared to unfocused beams. Immediate clinical applications include those associated with proton radiosurgery and functional radiosurgery of the brain and spine, however other treatment sites can be also envisioned. This project was sponsored with funding from the Department of Defense (DOD# W81XWH-BAA-10-1).

60 APPLIED LIFE SCIENCES↗

Cerebral Arteries Extraction using Level Set Segmentation and Adaptive Tracing for CT Angiography

We propose an approach for extracting cerebral arteries from partial Computed Tomography Angiography (CTA). The challenges of extracting cerebral arteries from CTA come from the fact that arteries are usually surrounded by bones and veins in the lower portion of a CTA volume. There exists strong intensity-value overlap between vessels and surrounding objects. Besides, it is inappropriate to assume the 2D cross sections of arteries are circle or ellipse, especially for abnormal vessels. The navigation of the arteries could change suddenly in the 3D space. In this paper, a method based on level set segmentation is proposed to target this challenging problem. For the lower portion of a CTA volume, we use geodesic active contour method to detect cross section of arteries in the 2D space. The medial axis of the artery is obtained by adaptively tracking along its navigation path. This is done by finding the minimal cross section from cutting the arteries under different angles in the 3D spherical space. This method is highly automated, with minimum user input of providing only the starting point and initial navigation direction of the arteries of interests.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LEPS2: the second Laser-Electron Photon facility at SPring-8

A new project to construct the second beamline for the laser-electron photon beam at SPring-8 (LEPS2) has started. Based on the LEPS experience, the project aims to improve the intensity of the photon beam and to expand the detector acceptance by adopting the BNL-E949 detector, which is a hermetic detector in a large 1 T solenoid magnet. The central region of tracking chambers will be upgraded for the LEPS2. A new LEPS2 experimental building has just been constructed outside the experimental hall of the storage ring. The present status of the development of a frozen-spin polarized HD target is also reported.

43 PARTICLE ACCELERATORS↗

On the consistency of Monte Carlo track structure DNA damage simulations

Purpose: Monte Carlo track structures (MCTS) simulations have been recognized as useful tools for radiobiological modeling. However, the authors noticed several issues regarding the consistency of reported data. Therefore, in this work, they analyze the impact of various user defined parameters on simulated direct DNA damage yields. In addition, they draw attention to discrepancies in published literature in DNA strand break (SB) yields and selected methodologies. Methods: The MCTS code Geant4-DNA was used to compare radial dose profiles in a nanometer-scale region of interest (ROI) for photon sources of varying sizes and energies. Then, electron tracks of 0.28 keV–220 keV were superimposed on a geometric DNA model composed of 2.7 × 10{sup 6} nucleosomes, and SBs were simulated according to four definitions based on energy deposits or energy transfers in DNA strand targets compared to a threshold energy E{sub TH}. The SB frequencies and complexities in nucleosomes as a function of incident electron energies were obtained. SBs were classified into higher order clusters such as single and double strand breaks (SSBs and DSBs) based on inter-SB distances and on the number of affected strands. Results: Comparisons of different nonuniform dose distributions lacking charged particle equilibrium may lead to erroneous conclusions regarding the effect of energy on relative biological effectiveness. The energy transfer-based SB definitions give similar SB yields as the one based on energy deposit when E{sub TH} ≈ 10.79 eV, but deviate significantly for higher E{sub TH} values. Between 30 and 40 nucleosomes/Gy show at least one SB in the ROI. The number of nucleosomes that present a complex damage pattern of more than 2 SBs and the degree of complexity of the damage in these nucleosomes diminish as the incident electron energy increases. DNA damage classification into SSB and DSB is highly dependent on the definitions of these higher order structures and their implementations. The authors’ show that, for the four studied models, different yields are expected by up to 54% for SSBs and by up to 32% for DSBs, as a function of the incident electrons energy and of the models being compared. Conclusions: MCTS simulations allow to compare direct DNA damage types and complexities induced by ionizing radiation. However, simulation results depend to a large degree on user-defined parameters, definitions, and algorithms such as: DNA model, dose distribution, SB definition, and the DNA damage clustering algorithm. These interdependencies should be well controlled during the simulations and explicitly reported when comparing results to experiments or calculations.

60 APPLIED LIFE SCIENCES↗

Beam-dynamics codes used at DARHT

Several beam simulation codes are used to help gain a better understanding of beam dynamics in the DARHT LIAs. The most notable of these fall into the following categories: for beam production – Tricomp Trak orbit tracking code, LSP Particle in cell (PIC) code, for beam transport and acceleration – XTR static envelope and centroid code, LAMDA time-resolved envelope and centroid code, LSP-Slice PIC code, for coasting-beam transport to target – LAMDA time-resolved envelope code, LSP-Slice PIC code. These codes are also being used to inform the design of Scorpius.

43 PARTICLE ACCELERATORS↗

Update on Ce+BAF Injector Baseline Simulations

Progress in the development of the positron injector concept for the Ce+BAF is presented. The results of start-to-end positron beam tracking simulations for two injector operating modes (low current high polarized beam and high current low polarized beam) are discussed. The efficiency of the positron capture system based on a normal conducting focusing solenoid downstream of the conversion target is compared with the efficiency of a superconducting solenoid.

Ushakov [Thomas Jefferson National Accelerator Fac↗

Sequestration of Sr-90 Subsurface Contamination in the Hanford 100-N Area by Surface Infiltration of a Ca-Citrate-Phosphate Solution

The objective of this project is to develop a method to emplace apatite precipitate in the 100N vadose zone, which results in sorption and ultimately incorporation of Sr-90 into the apatite structure. The Ca-citrate-PO4 solution can be infiltrated into unsaturated sediments to result in apatite precipitate to provide effective treatment of Sr-90 contamination. Microbial redistribution during solution infiltration and a high rate of citrate biodegradation for river water microbes (water used for solution infiltration) results in a relatively even spatial distribution of the citrate biodegradation rate and ultimately apatite precipitate in the sediment. Manipulation of the Ca-citrate-PO4 solution infiltration strategy can be used to result in apatite precipitate in the lower half of the vadose zone (where most of the Sr-90 is located) and within low-K layers (which are hypothesized to have higher Sr-90 concentrations). The most effective infiltration strategy to precipitate apatite at depth (and with sufficient lateral spread) was to infiltrate a high concentration solution (6 mM Ca, 15 mM citrate, 60 mM PO4) at a rapid rate (near ponded conditions), followed by rapid, then slow water infiltration. Repeated infiltration events, with sufficient time between events to allow water drainage in the sediment profile can be used to buildup the mass of apatite precipitate at greater depth. Low-K heterogeneities were effectively treated, as the higher residual water content maintained in these zones resulted in higher apatite precipitate concentration. High-K zones did not receive sufficient treatment by infiltration, although an alternative strategy of air/surfactant (foam) was demonstrated effective for targeting high-K zones. The flow rate manipulation used in this study to treat specific depths and heterogeneities are not as easy to implement at field scale due to the lack of characterization of heterogeneities and difficulty tracking the wetting front over a large subsurface area. However, the use of real-time surface and cross-borehole geophysics can be used to track the infiltrating Ca-citrate-PO4 front so some adjustments can be made in the infiltration rate to precipitate apatite in desired zones. In addition, the reactive transport code used in this study with field scale physical parameters for sediments can be used to evaluate infiltration strategies along with preliminary water infiltration tests at field scale.

58 GEOSCIENCES↗

Public Perceptions of Environmental Public Health Risks in the United States

Understanding public perceptions about environmental health hazards, exposures, and health impacts can help environmental public health practitioners to target and prioritize community activities, policy needs, and communication strategies. The online cross-sectional 2013 summer wave of the ConsumerStyles survey sampled U.S. adults and used questions from the Centers for Disease Control’s Environmental Public Health Tracking Program to measure public awareness of governmental efforts to track environmental exposures and links to health impacts, as well as perceptions of environmental health issues. Unadjusted and adjusted logistic regressions examined the associations between demographic characteristics and level of awareness of government environmental public health efforts or level of concern about health risks associated with environmental pollutants. Responses were received from 4033 participants, yielding a response rate of 66.0%. More than half of respondents (57.8%) noted concerns about health risks from environmental pollutants. More than one-third (40.0%) of respondents reported awareness of government efforts. Nearly 40% of respondents felt that none of the health impacts listed in the survey were related to environmental issues. Multiple logistic regression models showed that non-Hispanic blacks, other races, females, people with a college or higher education, and people living in the Midwest or South regions were more likely than their counterparts to be concerned about how the environment affects their health. Future work should focus on improving risk communication, filling the information gap on environmental health issues, and understanding how perceptions change over time.

54 ENVIRONMENTAL SCIENCES↗

Statistical Correlation of Heliostat Pointing Deviation With Wind

This work was carried out as part of the Heliostat Consortium (HelioCon) Field Deployment subtask with the aim to develop a reduced order model framework for correlating wind speed and pointing deviation of a heliostat facet. There are only sparse field measurements of heliostat pointing deviations and accompanying wind conditions published in the literature. Heliostat test standards, such as IEC 62862-4-3, propose a suite of tests including laser pointing repeatability at wind speeds below 4 m/s, and provide technical requirements for heliostat slope and tracking deviations in coarse average wind speed bins of 4 m/s, 6 m/s, and 8 m/s. In addressing the gap of the variation of heliostat pointing deviation with wind speed, field measurements of laser pointing on a grid target and wind conditions were analyzed in this study at the Third-Party Metrology Platform at the National Laboratory of the Rockies (NLR) Flatirons Campus. Horizontal pointing deviations were found to follow a logarithmic relationship with peak wind speed, whereas vertical pointing deviations follow an exponential relationship with peak wind speed. Both horizontal and vertical pointing deviations also follow a second order polynomial relationship, as expected from the proportionality of elastic loads and deformations with the square of wind speed. The results indicate that heliostat facet pointing deviations in the vertical direction increase at a faster rate than in the horizontal direction with increasing wind speed over the tested range, however these are dependent on the heliostat structural design. Next steps are recommended for additional field measurements to confirm a linear relationship of pointing deviation with applied moment on a heliostat facet, and to distinguish between gravity-induced and wind-induced pointing deviations at different elevation angles. The derived correlations in the preliminary analysis in this report serve as a case study for heliostat developers and plant operators to estimate the wind-induced pointing deviations and their variation with peak gust wind speed. Next steps in future work would recommend higher resolution and longer duration datasets for different elevation angles and wind directions to reduce uncertainties and variance of collected laser beam spot data and their correlations with bin-averaged wind speed.

17 WIND ENERGY↗

A data-driven method to estimate the antiproton background in the Mu2e experiment

The Mu2e experiment at Fermilab will search for the Charged Lepton Flavour Violating (CLFV) process of coherent, neutrinoless µ− → e − conversion in the field of an aluminum nucleus. The expected signal is a monochromatic electron with the energy of 104.97 MeV, slightly below the muon rest mass. Observation of a CLFV process would provide unambiguous evidence for Beyond the Standard Model (BSM) physics. Mu2e is sensitive to a wide range of BSM models and has the capability to distinguish between them, guiding us towards the most accurate models. The key features of the Mu2e experiment are: (1) a high intensity pulsed negative muon beam with about 1010 stopped µ −/s, and (2) a sophisticated superconducting solenoid system with a gradient magnetic field to form and guide the intense muon beam to the target. The Mu2e physics data taking is expected to begin in 2027. For Run I, the expected 5σ discovery sensitivity is Rµe = 1.2 × 10−15, with a total expected background of 0.11 ± 0.03 events. In the absence of a signal, the expected upper limit is Rµe < 6.2 × 10−16 at 90% CL. The success of this experiment hinges on the accurate estimation of the background from various SM processes that could provide signal-like electrons. One of the background processes is antiprotons annihilating in the stopping target to produce signal like electrons through π0 → γγ decays followed by γ conversions, and π− → µ−ν¯ decays followed by µ− decay. It is a relatively small background with large uncertainty (100%) due to the lack of antiproton production cross section information for the Mu2e proton beam energy of 8 GeV. We have developed a novel methodology to estimate the antiproton background in-situ. This forms the main theme of the thesis. We observed that at Mu2e energies, antiproton annihilation in the stopping target is the only source of events with multiple, simultaneous particle trajectories. From Geant4 simulations, only about 0.2% of the simulated antiproton annihilation events have a signal-like electron. Meanwhile, ∼ 5% of events have multiple reconstructible particle tracks per event. Therefore, we have devised a methodology to reconstruct the multi-track events and estimate the antiproton background by exploiting the large ratio of the production rates of the two final states.

Chithirasreemadam, Namitha [Pisa U.] (ORCID:000000↗

Dosimetric Effect of Prostate Motion During Helical Tomotherapy

Purpose: To assess the dosimetric consequence of intrafraction prostate motion on helical tomotherapy plans. Methods and Materials: An electromagnetic tracking device was used to measure real-time prostate motion for 515 fractions (16 patients). Motion tracks were used to retrospectively recalculate dose distributions using a four-dimensional calculation engine. The minimum dose (D{sub min}), maximum dose (D{sub max}), and dose to 95% of the volume (D{sub 95%}) were calculated for target volumes and compared with respective values from the treatment plan. The dosimetric effect was evaluated for each fraction. For each patient, the running cumulative effect was assessed throughout the course of treatment. Calculations were repeated assuming a time delay between initial patient setup and start of treatment. Results: Averaged over all fractions, the mean change in target D{sub 95%} was <1% (SD, 3-4%). Reductions in target D{sub 95%} of up to 20% were seen in individual fractions. Changes in prostate D{sub 95%} were similar in frequency and magnitude to D{sub 95%} changes in the planning target volume. The cumulative effect on target D{sub 95%} was approximately 1% (SD, 1%). The average cumulative effect after five fractions was 1% (SD, 1.5%). Conclusions: In general, the dosimetric effect of observed prostate motion on target D{sub 95%}was small. Infrequently severe D{sub 95%} degradations were observed for individual fractions, but their effect on the cumulative dose distribution was quickly reduced with minimal fractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗