Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Assembly and Delivery of Rabbit Capsules for Irradiation of Silicon Carbide Cladding Tube Specimens in the High Flux Isotope Reactor

Neutron irradiation of silicon carbide (SiC)-based fuel cladding under a high radial heat flux presents a critical challenge for SiC cladding concepts in light water reactors (LWRs). Fission heating in the fuel provides a high heat flux through the cladding, which, combined with the degraded thermal conductivity of SiC under irradiation, results in a large temperature gradient through the thickness of the cladding. The strong temperature dependence of swelling in SiC creates a complex stress profile in SiCbased cladding tubes as a result of differential swelling. The Nuclear Science User Facilities (NSUF) Program within the US Department of Energy Office of Nuclear Energy is supporting research efforts to improve the scientific understanding of the effects of irradiation on SiC cladding tubes. Ultimately, the results of this project will provide experimental validation of multi-physics models for SiC-based fuel cladding during LWR operation. The first objective of this project is to irradiate tube specimens using a previously developed design that allows for irradiation testing of miniature SiC tube specimens subjected to a high radial heat flux. The previous “rabbit” capsule design uses the gamma heating in the core of the High Flux Isotope Reactor (HFIR) to drive a high heat flux through the cladding tube specimens. A compressible aluminum foil allows for a constant thermal contact conductance between the cladding tubes and the rabbit housing despite swelling of the SiC tubes. To allow separation of the effects of irradiation from those due to differential swelling under a high heat flux, a new design was developed under the NSUF program. This design allows for irradiation of similar SiC cladding tube specimens without a high radial heat flux. This report briefly describes the irradiation experiment design concepts, summarizes the irradiation test matrix, and reports on the successful delivery of six rabbit capsules to the HFIR. Rabbits of both low and high heat flux configurations have been assembled, welded, evaluated, and delivered to the HFIR along with a complete quality assurance fabrication package. These rabbits contain a wide variety of specimens including monolith tubes, SiC fiber SiC matrix (SiC/SiC) composites, duplex specimens (inner composite, outer monolith), and specimens with a variety of metallic or ceramic coatings on the outer surface. The rabbits are targeted for insertion during HFIR cycle 475, which is scheduled for September 2017.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fabrication of titanium thermal protection system panels by the NOR-Ti-bond process

A method for fabricating titanium thermal protection system panels is described. The method has the potential for producing wide faying surface bonds to minimize temperature gradients and thermal stresses resulting during service at elevated temperatures. Results of nondestructive tests of the panels are presented. Concepts for improving the panel quality and for improved economy in production are discussed.

Wells, R. R.↗

The prominence-corona interface compared with the chromosphere-corona transition region

The intensities of 52 optically thin EUV emission lines formed at temperatures of 350,000 to 2.2 million K in nine hedgerow prominences observed at the limb are compared with the intensities of the same lines formed within network cells at the center of the solar disk in order to compare the prominence-corona interface (PC) with the chromosphere-corona transition region (CC). It is found for all nine prominences that the ratio of the intensity of a line measured in a cell to that in a prominence decreases with increasing temperature approximately as the -0.6 power of temperature. This ratio is used as the basis for comparing the PC with the CC in the framework of two different geometries wherein the prominence consists of one or more identical fully resolved slabs or threads in the line of sight or contains one or more identical unresolved cylindrical threads. It is concluded that three effects may contribute to the systematic difference between the PC and the CC: (1) the pressure within the PC might increase outward; (2) the temperature gradient within the PC might increase more slowly with temperature than in the CC; and (3) the unresolved internal geometry of a prominence can directly explain some, but not all, of the systematic difference.

Orrall, F. Q.↗

Linear theory of tearing in a high-beta plasma

The linear dispersion relation for a collisionless plasma in a sheared one-dimensional current sheet is calculated with reference to conditions in the daytime magnetopause. Calculations are extended to include plasmas with beta approximately equal to 1. It is found that the tearing mode eigenstructure and temporal growth rate are a sensitive function of the ratios l sub s/l sub G, l sub s/l sub T, and l sub s/l sub n, where l sub s is the shearing length of the magnetic field, l sub G is the gradient scale length, and l sub T is the temperature gradient scale length. In particular, if beta is approximately equal to 1, and l sub s is less than l sub G, l sub n, and l sub T, then the thickness of the layer over which particles are resonantly accelerated by the induction magnetic field is approximately rho, a thermal gyroradius. If the above conditions are not satisfied, plasma gradients may electrostatically stabilize the mode.

Quest, K. B.↗

Observations of mesoscale vertical velocities around frontal zones

Vertical velocity and reflectivity data obtained with a VHF Doppler radar over a 15-day period in October and November of 1981 are analyzed. Standard radiosonde data and surface observations were used to locate two occluded fronts, two warm fronts, and a cold front that passed the radar site. These fronts are also evident in the radar reflectivity data. Most studies of the vertical circulation patterns associated with mososcale systems have used precipitation and cloud formations as tracers. Unlike other observational techniques, the VHF radar permits the continuous measurement of the three-dimensional air velocity vector in time and height from a fixed location. With the beam in a vertically pointing position, signals are scattered from turbulent variations in the refractive index with half the scale of the radar wavelength and by regions with sudden changes in the refractive index associated with horizontally stratified layers. Generally, the strongest echoes occur at the maximum in the vertical gradient of refractivity, usually at the base of a temperature inversion, such as the tropopause. VHF radars can also be used to locate atmospheric fronts, which are characterized by static stability, large horizontal temperature gradients, large vorticities, and vertical wind shears. These radars can provide the velocity field data needed to study wave motions associated with fronts and compare the actual vertical circulation to theoretical predictions.

Dennis, T. S.↗

Ultralow noise performance of an 8.4-GHz maser-feedhorn system

A total system noise temperature of 6.6 K was demonstrated with an 8.4-GHz traveling wave maser and feedhorn operating in a cryogenic environment. Both the maser and feedhorn were inserted in the helium cryostat, with the maser operating in the 1.6-K liquid bath and the feedhorn cooled in the helium gas, with a temperature gradient along the horn ranging from the liquid bath temperature at its lower end to room temperature at its top. The ruby maser exhibited 43 dB of gain with a bandwidth of 76 MHz(-3 dB) centered at 8400 MHz. Discussions of the maser, cooled feedhorn, and cryostat designs are presented along with a discussion of the noise temperature measurements.

Johnson, D. L.↗

Multicomponent Convection Induced by Fronts in the Chlorate-Sulfite Reaction

An application of a new method is presented for the measurement of the temperature profiles of chemical waves propagating through a solution. Using solutions of thermocolor materials, the temperature distribution caused by the heat released in the propagating chlorate oxidation of sulfite was visualized and recorded using digital image processing methods. After calibration, the temperature gradient was calculated from the gray scale value in a digitized image. Extensive multicomponent convection ('fingering') was induced by descending fronts. Only ascending fingers were observed because of the large thermal gradient that suppressed descending ones. The characteristics of the temperature profile were determined as a function of initial sulfite and chlorate concentration, and tube diameter. Unusual behavior was observed when the fronts propagated under conditions of continuously changing diameter in a conical vessel. Fingering occurred periodically in a front descending in a flask with an increasing diameter. However, when a front propagated down in flask whose diameter decreased, no multicomponent convection was observed.

Nagy, Istvan P.↗

Modeling Thermal Contact Resistance

One difficulty in using cryocoolers is making good thermal contact between the cooler and the instrument being cooled. The connection is often made through a bolted joint. The temperature drop associated with this joint has been the subject of many experimental and theoretical studies. The low temperature behavior of dry joints have shown some anomalous dependence on the surface condition of the mating parts. There is also some doubts on how well one can extrapolate from the test samples to predicting the performance of a real system. Both finite element and analytic models of a simple contact system have been developed. The model assumes (a) the contact is dry (contact limited to a small portion of the total available area and the spaces in-between the actual contact patches are perfect insulators), (b) contacts are clean (conductivity of the actual contact is the same as the bulk), (c) small temperature gradients (the bulk conductance may be assumed to be temperature independent), (d) the absolute temperature is low (thermal radiation effects are ignored), and (e) the dimensions of the nominal contact area are small compared to the thickness of the bulk material (the contact effects are localized near the contact). The models show that in the limit of actual contact area much less than the nominal area (a much less than A), that the excess temperature drop due to a single point of contact scales as a(exp -1/2). This disturbance only extends a distance approx. A(exp 1/2) into the bulk material. A group of identical contacts will result in an excess temperature drop that scales as n(exp -1/2), where n is the number of contacts and n dot a is constant. This implies that flat rough surfaces will have a lower excess temperature drop than flat polished surfaces.

Kittel, Peter↗

An Analysis of the North Polar Spur using HaloSat

We present HaloSat X-ray observations of the entirety of the bright X-ray emitting feature known14as the North Polar Spur (NPS). The large field of view of HaloSat enabled coverage of the entire15bright NPS in only fourteen fields, which were each observed for≈30,000 s. We find that the NPS16fields are distinct in both brightness and spectral shape from the surrounding halo fields. We fit the17NPS as two thermal components in ionization equilibrium with temperatures kTcool≈0.087 keV18and kThot≈0.28 keV. We note a temperature gradient in the NPS hot component with an inner19arc temperature warmer than the outer arc. The emission measures we find for the cool component20of the NPS is a factor of 3-5 greater than that of the hot component, which suggests that the bulk of21the NPS material is in the≈0.1 keV component. We evaluate distance estimates of 0.4 kpc and 8.022kpc for the NPS. Our findings suggest a preference for a distant NPS with an energy of≈6×105423erg, an age of≈10 Myr, and pressures consistent with a 10μG magnetic field associated with the24Fermi bubbles. The electron density≈10×10−3cm−3is consistent with estimates for the shock25region surrounding a galactic scale event.

Daniel M LaRocca↗

Multiple Probe Measurements at Uranus Motivated By Spatial Variability

Motivation: Spatial variations in the temperature field and composition of Uranus' atmosphere demonstrate a need for multiple entry probes to characterize vertical profiles in multiple locations. We will review variation of composition and temperature, which are produced by dynamical processes on a range of scales from global (polar anomalies, zonal bands) to regional (vortices, storms) [1–2]. In particular, the spatial variation of convective activity is not well understood based on existing remote sensing observations [3]. Understanding how these processes operate, and how they modulate variable composition, is key to constraining bulk atmospheric abundances. Abundances in turn provide cosmochemical constraints on planetary origins. Secondary probes at Uranus: Key measurements for secondary probes are temperature-pressure profiles, along with compositional profiles. Radio occultations are limited to shallow levels less than ~2 bar [4]. In situ temperature-pressure measurements (or atmospheric structure measurements) can unambiguously extend these results to deeper levels. Measurements with vertical resolution of at least 2 km are needed to characterize anomalies like the 1.2-bar feature from the Voyager 2 occultation at 2–6° S [4], which supports a range of temperature gradients depending on assumptions of composition. Simultaneous measurements of temperature, pressure, and composition are key to understanding this class of features. Species such as methane, hydrogen sulfide, and ammonia must be measured along a probe descent profile because they vary over several orders of magnitude due to the strong temperature dependence of their saturation vapor pressures [e.g., 5]. Results of these measurements can be interpreted to understand the potential for moist convective activity in the atmosphere. Lessons from the other giant planets: On Jupiter, the Galileo Probe's entry into a meteorologically distinct five-micron hot spot led many to interpret the local composition as column-stretched, so that well-mixed abundances were reached at deeper levels than in surrounding, unperturbed regions [6–8]. Ground-based microwave measurements and Juno data now indicate that the deep depletion of ammonia is a very widespread atmospheric characteristic not limited to 5-µm hot spots [9–11]. But in the absence of multiple probes, we do not know if the other volatiles H2S and H2O behave in the same way. The open questions for the Jupiter case strongly motivate sending multiple probes to Uranus. On Saturn, retrievals of NH3 and PH3 abundances at shallow levels vary with latitude [12], but it is unknown how deep these differences extend, which is why a Saturn probe (or probes) was a mission theme for NASA's New Frontiers 4 and 5 opportunities [13]. Challenges for secondary probes: Cost is an issue due to the perception that it involves sacrifices to other mission elements. Spacecraft trajectories may be constrained by needs for orbit insertion that limit probe deliveries to different latitudes, and additional limitations may be placed on communication windows for probe descent phases (particularly if multiple probes are released from the orbiter simultaneously) [14]. Finally, composition sensors for miniature secondary probes are not at the required technological maturity [15]. Mass spectrometers are typically too large, massive, and powerhungry, while smaller nanosensors are only beginning to be developed for planetary missions. Finally, the need for probe survival heating is most easily met by radioisotope heat sources, but these require regulatory approvals that are even more difficult to satisfy compared to standard environmental reviews [16], unless the secondary probe is designed as a core element of a mission. References: [1] Molter E.M., et al. (2021) PSJ, 2, 3. [2] Rowe-Gurney N., et al. (2021) Icar, 365, 114506. [3] Hueso R., Sánchez-Lavega A. (2019) SSRv, 215, 52. [4] Lindal G.F., et al. (1987) JGR, 92, 14987– 15001. [5] Simon A.A., et al. (2022) RemS, 14, 1518. [6] Atreya, S.K., et al. (1997) in The Three Galileos: The Man, the Spacecraft, the Telescope, pp. 249–260 (C. Barbieri et al., eds.). [7] Showman A.P., Ingersoll A.P. (1998) Icar, 132, 205–220. [8] Friedson A.J. (2005) Icar, 177, 1–17. [9] de Pater I., et al. (2001) Icar, 149, 66–78. [10] Li C., et al. (2017) GeoRL, 44, 5317–5325. [11] de Pater I., et al. (2019) Icar, 322, 168–191. [12] Fletcher L.N., et al. (2009) Icar, 202, 543–564. [13] National Research Council (2011) Vision and Voyages. [14] Sayanagi K.M., et al. (2020) SSRv, 216, 72. [15] Wong M.H. et al. (2021) BAAS, 53, 486. [16] Zide A., Mendoza-Hill A., Cheney D. (2022) COSPAR Abstracts H0.6-0012-22.

Michael H Wong↗

Comparative cut-bar thermal conductivity apparatus.

Construction details, error analysis, and typical data for a rapid comparative device for thermal conductivity measurements are presented. The apparatus consists of a comparative cut-bar arrangement contained in a bell-jar. The cylinder shaped specimen is placed between two ARMCO-iron meter bars of the same diameter. The upper bar is equipped with a heater, while the lower one is terminated in a heat sink. The temperature gradient along the bars is measured with a series of copper/constantan microthermocouples, spot welded to them. The assembly is held together by loading the bars to a desired pressure, via a pneumatic cylinder. Contact resistance at the boundaries between the specimen and the meter bars is minimized by using a Hg/In/Ga alloy film at the interface and sufficient loading force. The gradients determined for the meter bars then may be extrapolated to the boundaries yielding the temperature drop along the specimen. Using two different length specimens, the magnitude of the temperature drop across the interface can be computed, or the true gradient along the specimen can be obtained from the difference in overall temperature drops and lengths.

Gaal, P. S.↗

Nucleation and growth control in protein crystallization

The five topics summarized in this final report are as follows: (1) a technique for the expedient, semi-automated determination of protein solubilities as a function of temperature and application of this technique to proteins other than lysozyme; (2) a small solution cell with adjustable temperature gradients for the growth of proteins at a predetermined location through temperature programming; (3) a microscopy system with image storage and processing capability for high resolution optical studies of temperature controlled protein growth and etching kinetics; (4) growth experiments with lysozyme in thermosyphon flow ; and (5) a mathematical model for the evolution of evaporation/diffusion induced concentration gradients in the hanging drop protein crystallization technique.

Rosenberger, Franz↗

Implementation and testing of the on-the-fly thermal scattering Monte Carlo sampling method for graphite and light water in MCNP6

Here, a proper treatment of thermal neutron scattering requires accounting for chemical binding through a scattering law S(α,β,T). Monte Carlo codes sample the secondary neutron energy and angle after a thermal scattering event from probability tables generated from S(α,β,T) tables at discrete temperatures, requiring a large amount of data for multiscale and multiphysics problems with detailed temperature gradients. We have previously developed a method to handle this temperature dependence on-the-fly during the Monte Carlo random walk using polynomial expansions in 1/T to directly sample the secondary energy and angle. In this paper, the on-the-fly method is implemented into MCNP6 and tested in both graphite-moderated and light water-moderated systems. The on-the-fly method is compared with the thermal ACE libraries that come standard with MCNP6, yielding good agreement with integral reactor quantities like k-eigenvalue and differential quantities like single-scatter secondary energy and angle distributions. The simulation runtimes are comparable between the two methods (on the order of 5–15% difference for the problems tested) and the on-the-fly fit coefficients only require 5–15 MB of total data storage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Healing of thermocapillary film rupture by viscous heating

Thin liquid films sitting on a heated solid substrate and surrounded by a colder ambient gas phase are strongly affected by surface-shear stresses induced by surface tension and temperature gradients, as well as by viscous and capillary forces. The temperature dependence of surface tension may lead to thinning of liquid-film depressions promoting instability which takes place when a critical temperature difference $\unicode[STIX]{x0394}\unicode[STIX]{x1D717}_{cr}$ between the substrate and the ambient gas phase is exceeded. In this article we show theoretically that viscous heating, previously neglected in related literature, may delay or suppress the thermocapillary instability and leads to film healing. The viscous heating effect, by inhibiting heat transfer, prevents the system from reaching the critical value $\unicode[STIX]{x0394}\unicode[STIX]{x1D717}_{cr}$ required to bring about instability. As a consequence, the system remains within the stability region, suppressing film rupture. The presence of the viscous heating effect leads to a persistent circulating motion of two counter-rotating vortices lying diametrically opposite to a depression of the liquid–gas interface reducing the wavelength of disturbances to one half of its initial value. This effect has yet to be observed in experiment.

Mechanics↗

Linear ion-scale microstability analysis of high and low-collisionality NSTX discharges and NSTX-U projections

Linear gyrokinetic simulations were conducted to investigate ion-gyroradius-scale micro-instability predictions for high-beta NSTX discharges and NSTX-U projections that span over an order of magnitude variation in collisionality. A complex mix of microtearing modes and hybrid trapped electron modes/kinetic ballooning modes (TEM/KBM) is predicted for all experimental or projected conditions. Ion temperature gradient (ITG) instabilities are typically stable in the NSTX discharges investigated, consistent with the observed neoclassical ion thermal transport. ITG thresholds inferred from the simulations are typically much higher than the experimental NSTX gradients, as well as the projected gradients in the NSTX-U scenario, which assumed ion temperatures limited by neoclassical transport only. The analysis suggests ITG instabilities are unlikely to contribute significant anomalous thermal losses in high-beta, lower collisionality NSTX-U scenarios. On the other hand, the NSTX experimental profiles and NSTX-U projections are predicted to be very close to the predicted onset of unstable KBM at most radii investigated. The proximity of the various discharges to the KBM instability threshold implies it may play an important role in setting profile shapes and limiting global energy confinement. Here, it remains to be understood and predicted how KBM contributes to multi-channel transport (thermal and particle transport, for both ions and electrons) in a way that is consistent with experimental inferences.

36 MATERIALS SCIENCE↗

Effect of cooldown and residual magnetic field on the performance of niobium–copper clad superconducting radio-frequency cavity

Here, we present the results of rf measurements on a niobium–copper clad superconducting radio-frequency cavity with different cooldown conditions and residual magnetic field in a vertical test Dewar in order to explore the effect of thermal current induced magnetic field and its trapping on the performance of the cavity. The residual resistance, extracted from the Q 0 ( T ) curves in the temperature range 4.3–1.5 K, showed no dependence on a temperature gradient along the cavity during the cooldown across the critical temperature up to ~50 K m –1 . The rf losses due to the trapping of residual magnetic field during the cavity cooldown were found to be ~4.3 nΩ μ T –1 , comparable to the values measured in bulk niobium cavities. An increase of residual resistance following multiple cavity quenches was observed along with evidence of trapping of magnetic flux generated by thermoelectric currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved apparatus for trapped radical and other studies down to 1.5 K

A Dewar system and associated equipment for electron paramagnetic resonance (EPR) studies of trapped free radicals and other optical or irradiation experiments are described. The apparatus is capable of reaching a temperature of 1.5 K and transporting on the order of 20 W per K temperature gradient; its principal advantages are for use at pumped cryogen temperatures and for experiments with large heat inputs. Two versions of the apparatus are discussed, one of which is designed for EPR in a rectangular cavity operating in a TE(102) mode and another in which EPR is performed in a cylindrical microwave cavity.

Woollam, J. A.↗