Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Femtosecond laser ablation of brass in air and liquid media

Laser ablation of brass in air, water, and ethanol was investigated using a femtosecond laser system operating at a wavelength of 785 nm and a pulse width less than 130 fs. Scanning electron and optical microscopy were used to study the efficiency and quality of laser ablation in the three ablation media at two different ablation modes. With a liquid layer thickness of 3 mm above the target, ablation rate was found to be higher in water and ethanol than in air. Ablation under water and ethanol showed cleaner surfaces and less debris re-deposition compared to ablation in air. In addition to spherical particles that are normally formed from re-solidified molten material, micro-scale particles with varying morphologies were observed scattered in the ablated structures (craters and grooves) when ablation was conducted under water. The presence of such particles indicates the presence of a non-thermal ablation mechanism that becomes more apparent when ablation is conducted under water.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication of a 238Pu target

Precision neutron-induced reaction data are important for modeling the network of isotope production and destruction within a given diagnostic chain. This network modeling has many applications such as the design of advanced fuel cycle for reactors and the interpretation of radiochemical data related to the stockpile stewardship and nuclear forensics projects. Our current funded effort is to improve the neutron-induced reaction data on the short-lived actinides and the specific goal is to improve the neutron capture data on {sup 238}Pu with a half-life of 87.7 years. In this report, the fabrication of a {sup 238}Pu target for the proposed measurement using the DANCE array at LANL is described. The {sup 238}Pu target was fabricated from a sample enriched to 99.35%, acquired from ORNL. A total of 395 {micro}g was electroplated onto both sides of a 3 {micro}m thick Ti foil using a custom-made plating cell, shown in Fig 1. The target-material loaded Ti foil is sandwiched between two double-side aluminized mylar foils with a thickness of 1.4 {micro}m. The mylar foil is glued to a polyimide ring. This arrangement is shown partially in Fig. 2. The assembled target is then inserted into an aluminum container with a wall thickness of 0.76 mm, shown in Fig. 3. A derlin ring is used to keep the target assembly in place. The ends of this cylindrical container are vacuum-sealed by two covers with thin Kapton foils as windows for the beam entrance and exit. Shown in Fig. 4 is details of the arrangement. This target is used for phase I of the proposed measurement on {sup 238}Pu scheduled for Nov 2010 together with the DANCE array to address the safety issues raised by LANL. Shown in Fig. 5 is the preliminary results on the yield spectrum as a function of neutron incident energy with a gate on the total {gamma}-ray energy of equivalent Q value. Since no fission PPAC is employed, the distinction between the capture and fission events cannot be made, which is important for the higher neutron incident energy. However, it indicates that a cross section of less than one barn can be measured. The second phase of this experiment will be carried out in 2011 by assembling a PPAC with the {sup 238}Pu target to extend the measurement to higher neutron incident energies by distinguishing the capture from fission events. The fission cross section becomes dominant for neutron incident energies above 30 keV. This PPAC was developed in FY2010 under the NA22 funding and performed very well for the {sup 239}Pu and {sup 241}Pu measurements. A new {sup 238}Pu target will be fabricated for the phase II measurement using the same electroplating technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Soft x-ray shock loading and momentum coupling in meteorite and planetary materials.

X-ray momentum coupling coefficients, C{sub M}, were determined by measuring stress waveforms in planetary materials subjected to impulsive radiation loading from the Sandia National Laboratories Z-machine. Results from the velocity interferometry (VISAR) diagnostic provided limited equation-of-state data as well. Targets were iron and stone meteorites, magnesium rich olivine (dunite) solid and powder ({approx}5--300 {mu}m), and Si, Al, and Fe calibration targets. All samples were {approx}1 mm thick and, except for Si, backed by LiF single-crystal windows. The x-ray spectrum included a combination of thermal radiation (blackbody 170--237 eV) and line emissions from the pinch material (Cu, Ni, Al, or stainless steel). Target fluences 0.4--1.7 kJ/cm{sup 2} at intensities 43--260 GW/cm{sup 2} produced front surface plasma pressures 2.6--12.4 GPa. Stress waves driven into the samples were attenuating due to the short ({approx}5 ns) duration of the drive pulse. Attenuating wave impulse is constant allowing accurate C{sub M} measurements provided mechanical impedance mismatch between samples and the window are known. Impedance-corrected C{sub M} determined from rear-surface motion was 1.9--3.1 x 10{sup -5} s/m for stony meteorites, 2.7 and 0.5 x 10{sup -5} s/m for solid and powdered dunite, 0.8--1.4 x 10{sup -5}.

36 MATERIALS SCIENCE↗

Engineered Elastomer Substrates for Guided Assembly of Complex 3D Mesostructures by Spatially Nonuniform Compressive Buckling

Approaches capable of creating 3D mesostructures in advanced materials (device-grade semiconductors, electroactive polymers, etc.) are of increasing interest in modern materials research. A versatile set of approaches exploits transformation of planar precursors into 3D architectures through the action of compressive forces associated with release of prestrain in a supporting elastomer substrate. Although a diverse set of 3D structures can be realized in nearly any class of material in this way, all previously reported demonstrations lack the ability to vary the degree of compression imparted to different regions of the 2D precursor, thus constraining the diversity of 3D geometries. This paper presents a set of ideas in materials and mechanics in which elastomeric substrates with engineered distributions of thickness yield desired strain distributions for targeted control over resultant 3D mesostructures geometries. This approach is compatible with a broad range of advanced functional materials from device-grade semiconductors to commercially available thin films, over length scales from tens of micrometers to several millimeters. A large range of 3D structures can be produced in this way, some of which have direct relevance to applications in tunable optics and stretchable electronics.

36 MATERIALS SCIENCE↗

High Power Cryogenic Targets

The development of high power cryogenic targets for use in parity violating electron scattering has been a crucial ingredient in the success of those experiments. As we chase the precision frontier, the demands and requirements for these targets have grown accordingly. We discuss the state of the art, and describe recent developments and strategies in the design of the next generation of these targets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spike morphology in blast-wave-driven instability experiments

The laboratory experiments described in the present paper observe the blast-wave-driven Rayleigh-Taylor instability with three-dimensional (3D) initial conditions. About 5 kJ of energy from the Omega laser creates conditions similar to those of the He-H interface during the explosion phase of a supernova. The experimental target is a 150 {mu}m thick plastic disk followed by a low-density foam. The plastic piece has an embedded, 3D perturbation. The basic structure of the pattern is two orthogonal sine waves where each sine wave has an amplitude of 2.5 {mu}m and a wavelength of 71 {mu}m. In some experiments, an additional wavelength is added to explore the interaction of modes. In experiments with 3D initial conditions the spike morphology differs from what has been observed in other Rayleigh-Taylor experiments and simulations. Under certain conditions, experimental radiographs show some mass extending from the interface to the shock front. Current simulations show neither the spike morphology nor the spike penetration observed in the experiments. The amount of mass reaching the shock front is analyzed and potential causes for the spike morphology and the spikes reaching the shock are discussed. One such hypothesis is that these phenomena may be caused by magnetic pressure, generated by an azimuthal magnetic field produced by the plasma dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cyclic nanoindentation studies on CrN thin films prepared by RF sputtering on Zr-based metallic glass

Cyclic nanoindentation tests were carried out to study the influence of the chromium nitride thin films on the mechanical properties of Zr-based metallic glass. Chromium nitride thin coatings have been deposited on Zr{sub 50}Cu{sub 40}Al{sub 10} metallic glass substrate by RF sputtering. The deposition process was done at room temperature under nitrogen reactive gas using a metallic chromium target. The CrN films have a thickness of 300 nm. Several cyclic nanoindentation measurements were conducted on CrN films and Zr{sub 50}Cu{sub 40}Al{sub 10} metallic glass substrate samples at various loading rate values. We have found that the coated metallic glass sample shows high mechanical properties such as hardness and reduced elastic modulus. Cyclic nanoindentation results show a hardening behaviour for these CrN coatings. Moreover, the CrN coated on Zr-based metallic glass was found to have a high value of resistance to crack propagation, as being analysed through the SEM pictures of the residual Vickers indentation impressions.

36 MATERIALS SCIENCE↗

Aluminium plasma production at high laser intensity

Thick and thin films of Al targets were irradiated in vacuum with iodine laser at 1315 nm wavelength, 300 ps pulse duration at a maximum intensity of about 10{sup 16} W/cm{sup 2} by varying the pulse energy and focal position. The laser-generated plasma was monitored in forward and backward directions by using ion collectors, SiC detectors, Thomson parabola spectrometer, and X-ray streak camera. Ion emission shows maximum proton energy of about 4 MeV in self-focusing conditions and a maximum Al ion energy of about 50 MeV. An evaluation of the electric field driving ions in conditions of target normal sheath acceleration is given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using L-shell x-ray spectra to determine conditions of non-local thermal dynamic equilibrium plasmas

K-shell x-ray spectra of Li- to H-like ions have long been used to determine plasma conditions. The ratio of integrated line intensities is used to determine the temperature. At the density of non-local thermal dynamic equilibrium (NLTE) plasmas (ne ≈ 10 21 cm -3 ), the K-shell spectrum is not very sensitive to density. We propose using the L-shell emission of open L-shell ions (C- to Li-like) as an alternative to determine both temperature and density of NLTE plasmas. First, the L-shell models of a mid-Z material need to be verified against the temperatures obtained using a K-shell spectrum of a low-Z material. A buried layer platform is being developed at the OMEGA laser to study the open L-shell spectra of NLTE plasmas of mid-Z materials. Studies have been done using a 250 μm diameter dot composed of a layer of 1200 Å thick Zn between two 600 Å thick layers of Ti, in the center of a 1000 μm diameter, 13 μm thick beryllium tamper. Lasers heat the target from both sides for up to 3 ns. The size of the emitting volume vs time was measured with x-ray imaging (face-on and side-on) to determine the density. The temperature was measured from the Ti K-shell spectra. The use of this platform for the verification of atomic L-shell models is discussed.

36 MATERIALS SCIENCE↗

Exploratory study of fission product yields of neutron-induced fission of U 235 , U 238 , and Pu 239 at 8.9 MeV

Using dual-fission chambers each loaded with a thick (200–400–mg/cm 2 ) actinide target of 235,238 U or 239 Pu and two thin (~10–100–μg/cm 2 ) reference foils of the same actinide, the cumulative yields of fission products ranging from 92 Sr to 147 Nd have been measured at E n = 8.9MeV. The 2 H(d,n) 3 He reaction provided the quasimonoenergetic neutron beam. Here, the experimental setup and methods used to determine the fission product yield (FPY) are described, and results for typically eight high-yield fission products are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of the K -Shell Opacity of a Solid-Density Magnesium Plasma Heated by an X-Ray Free-Electron Laser

We present measurements of the spectrally resolved x rays emitted from solid-density magnesium targets of varying sub-μm thicknesses isochorically heated by an x-ray laser. The data exhibit a largely thickness independent source function, allowing the extraction of a measure of the opacity to K-shell x rays within well-defined regimes of electron density and temperature, extremely close to local thermodynamic equilibrium conditions. The deduced opacities at the peak of the Kα transitions of the ions are consistent with those predicted by detailed atomic-kinetics calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unfolding linac photon spectra and incident electron energies from experimental transmission data, with direct independent validation

Purpose: In a recent computational study, an improved physics-based approach was proposed for unfolding linac photon spectra and incident electron energies from transmission data. In this approach, energy differentiation is improved by simultaneously using transmission data for multiple attenuators and detectors, and the unfolding robustness is improved by using a four-parameter functional form to describe the photon spectrum. The purpose of the current study is to validate this approach experimentally, and to demonstrate its application on a typical clinical linac. Methods: The validation makes use of the recent transmission measurements performed on the Vickers research linac of National Research Council Canada. For this linac, the photon spectra were previously measured using a NaI detector, and the incident electron parameters are independently known. The transmission data are for eight beams in the range 10-30 MV using thick Be, Al and Pb bremsstrahlung targets. To demonstrate the approach on a typical clinical linac, new measurements are performed on an Elekta Precise linac for 6, 10 and 25 MV beams. The different experimental setups are modeled using EGSnrc, with the newly added photonuclear attenuation included. Results: For the validation on the research linac, the 95% confidence bounds of the unfolded spectra fall within the noise of the NaI data. The unfolded spectra agree with the EGSnrc spectra (calculated using independently known electron parameters) with RMS energy fluence deviations of 4.5%. The accuracy of unfolding the incident electron energy is shown to be {approx}3%. A transmission cutoff of only 10% is suitable for accurate unfolding, provided that the other components of the proposed approach are implemented. For the demonstration on a clinical linac, the unfolded incident electron energies and their 68% confidence bounds for the 6, 10 and 25 MV beams are 6.1 {+-} 0.1, 9.3 {+-} 0.1, and 19.3 {+-} 0.2 MeV, respectively. The unfolded spectra for the clinical linac agree with the EGSnrc spectra (calculated using the unfolded electron energies) with RMS energy fluence deviations of 3.7%. The corresponding measured and EGSnrc-calculated transmission data agree within 1.5%, where the typical transmission measurement uncertainty on the clinical linac is 0.4% (not including the uncertainties on the incident electron parameters). Conclusions: The approach proposed in an earlier study for unfolding photon spectra and incident electron energies from transmission data is accurate and practical for clinical use.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-626: Intracranial SRS Re-Treatment Without Acquisition of New CT Images

Purpose: Linear accelerator based stereotactic radiosurgery (SRS) for multiple intracranial lesions with frequent surveillance is becoming a popular treatment option. This strategy leads to retreatment with SRS as new lesions arise. Currently, each course of treatment uses magnetic resonance (MR) and computed tomography (CT) images for treatment planning. We propose that new MR images, with course 1 CT images, may be used for future treatment plans with negligible loss of dosimetric accuracy. Methods: Ten patients that received multiple courses of SRS were retrospectively reviewed. The treatment plans and contours from non-initial courses were copied to the initial CTs and recalculated. Doses metrics for the plans calculated on the initial CTs and later CTs were compared. All CT scans were acquired on a Philips CT scanner with a 600 mm field of view and 1 mm slice thickness (Philips Healthcare, Andover, MA). All targets were planned to 20 Gy and calculated in Eclipse V. 13.6 (Varian, Palo Alto, CA) using analytic anisotropic algorithm with 1 mm calculation grid. Results: Sixteen lesions were evaluated. The mean time between courses was 250 +/− 215 days (range 103–979). The mean target volume was 2.0 +/− 2.9 cc (range 0.1–10.1). The average difference in mean target dose between the two calculations was 0.2 +/− 0.3 Gy (range 0.0 – 1.0). The mean conformity index (CI) was 1.28 +/− 0.14 (range 1.07 – 1.82). The average difference in CI was 0.03 +/− 0.16 (range 0.00 – 0.44). Targets volumes < 0.5 cc showed the largest changes in both metrics. Conclusion: Continued treatment based on initial CT images is feasible. Dose calculation on the initial CT for future treatments provides reasonable dosimetric accuracy. Changes in dose metrics are largest for small volumes, and are likely dominated by partial volume effects in target definition.

60 APPLIED LIFE SCIENCES↗

Polarized positrons at Ce\(^+\)BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab [1]. This concept is based on positron beam generation by a high current polarized electron beam (1 mA, 120 MeV, >85% polarization) irradiating a 4 mm thick rotating water-cooled tungsten target or liquid metal target. The update on the development of the Ce+BAF injector concept including the polarized electron source, the development of high power targets, simulations of positron capture, the design of the transport line from the positron injector to the CEBAF North Linac and the planned experiment to measure the upper limits of transverse and longitudinal emittances accepted by the 12 GeV CEBAF optics are presented. [1] J. Grames et al., "Positron beams at Ce+BAF", in Proc. 14th Int. Particle Accelerator Conf. (IPAC’23), Venice, Italy, MOPL152, pp. 896–899 (2023). doi:10.18429/JACoW-IPAC2023-MOPL152

Ushakov, Andriy↗

Xanthos-Lake Dataset

The Xanthos-Lake v1.0 dataset provides the input data, trained machine-learning models, and simulation outputs needed to characterize lake water balance, snow and ice conditions, and mixing-layer temperature within the Xanthos global hydrological modeling framework. The dataset supports lake representation across a wide range of lake sizes and hydroclimatic conditions by combining xLSIM, a basin-specific machine-learning emulator of lake snow, ice, ice-cover fraction, and mixing-layer temperature, with the Xanthos-Lake water-balance model. The archive contains NetCDF datasets used to train and evaluate xLSIM, trained model weights, processed meteorological and lake-property inputs, and basin- and lake-category-specific simulation outputs. These materials are organized into four primary data groups, described below. Snowice_model_inputs: Contains the NetCDF input data used to train xLSIM. The xLSIM machine-learning framework uses three lake-based datasets. The meteorological forcing dataset provides monthly relative humidity, specific humidity, surface wind speed, maximum and minimum air temperature, downward longwave and shortwave radiation, snowfall, surface air pressure, and total precipitation. Lake surface area is included as an additional static predictor. The target-state dataset provides lake ice thickness, snow depth, snow cover, and lake mixing-layer temperature, while a companion lake-surface dataset provides the lake ice-cover fraction. Before training, ice thickness and snow depth are converted from meters to centimeters, mixing-layer temperature is converted from kelvin to degrees Celsius and constrained to nonnegative values, and ice-cover fraction is converted from a fraction to a percentage. The predictor variables are normalized using statistics calculated across the selected lakes and time steps. Snowice_model_outputs: Contains the NetCDF outputs generated by xLSIM. For each basin, xLSIM produces a file containing observed and predicted lake-state variables for the training, validation, and testing periods. The modeled variables include lake ice thickness, snow depth, snow cover, mixing-layer temperature, and lake ice-cover fraction. For basins without a sufficiently persistent snow-and-ice signal, the emulator predicts only mixing-layer temperature. The outputs also include training and validation loss histories, the selected model configuration, identifiers of the lakes used in training, and SHAP-based feature-importance information at the global, lake, and seasonal-regime levels. The trained machine-learning model weights are provided separately within the dataset archive. Together, these files support model evaluation and subsequent coupling with the Xanthos-Lake water-balance framework. XanthosLAKES: Contains the NetCDF input data used by the Xanthos-Lake framework. Monthly meteorological inputs include relative and specific humidity, downward shortwave and longwave radiation, mean, maximum, and minimum air temperature, wind speed, precipitation, snowfall, and surface air pressure. Static lake-property datasets provide lake identifiers, geographic locations, surface area, volume, mean depth, elevation, drainage area, fetch, outlet-routing information, and associated Xanthos grid-cell attributes. Separate bathymetric datasets provide the coefficients of the area–depth and volume–depth relationships for each aggregated lake unit. GLEV-based records provide observed lake surface area and evaporation data used to initialize lake states, define reference conditions, and calibrate and evaluate the model. Xanthos-Lake Outputs: Contains the basin- and lake-category-specific NetCDF outputs generated by Xanthos-Lake. Monthly variables include lake surface area, storage volume, outlet discharge, evaporation rate, evaporation volume, lake–groundwater exchange, lake inflow, ice thickness, snow depth, snow-cover fraction, ice-cover fraction, and mixing-layer temperature. The files also contain lake-specific calibration and validation statistics, including normalized root-mean-square error, mean absolute error, Nash–Sutcliffe efficiency, Kling–Gupta efficiency, and percent bias. Stored calibrated and derived parameters include the weir discharge coefficient, fractional freeboard, groundwater exchange coefficient, reference water level, corresponding reference surface area and storage volume, weir-width adjustment factor, and the fraction of routed inflow entering the lake. Basin identifiers, lake category, simulation period, calibration and validation periods, and parameter-schema information are retained as NetCDF metadata.

Abeshu, Guta [Pacific Northwest National Laborator↗

Lunar and Planetary Science XXXV: Impacts

The session "Impacts" included the following reports: Impacts in Two-layered Targets on Earth: Effects of Cover Thickness on Crater Morphostructure; Keurusselkae, A New Impact Structure in Central Finland; The Great Permian Extinction Debate; Towards a Better Understanding of Marine Impact Processes: What a Potential Drilling of the Mj lnir Crater (Barents Sea) Has to Offer; and Field Studies in the Central Uplift of the Vredefort Impact Structure.

Source record↗

Large Impact Features on Europa: Results of the Galileo Nominal Mission

The Galileo Orbiter examined several impact features on Europa at considerably better resolution than was possible from Voyager. The new data allow us to describe the morphology and infer the geology of the largest impact features on Europa, which are probes into the crust. We observe two basic types of large impact features: (1) "classic" impact craters that grossly resemble well-preserved lunar craters of similar size but are more topographically subdued (e.g., Pwyll) and (2) very flat circular features that lack the basic topographic structures of impact craters such as raised rims, a central depression, or central peaks, and which largely owe their identification as impact features to the field of secondary craters radially sprayed about them (e.g., Callanish). Our interpretation is that the classic craters (all <30 km diameter) formed entirely within a solid target at least 5 to 10 km thick that exhibited brittle behavior on time scales of the impact events. Some of the classic craters have a more subdued topography than fresh craters of similar size on other icy bodies such as Ganymede and Callisto, probably due to the enhanced viscous relaxation produced by a steeper thermal gradient on Europa. Pedestal ejecta facies on Europa (and Ganymede) may be produced by the relief-flattening movement of plastically deforming but otherwise solid ice that was warm at the time of emplacement. Callanish and Tyre do not appear to be larger and even more viscously relaxed versions of the classic craters; rather they display totally different morphologies such as distinctive textures and a series of large concentric structural rings cutting impact-feature-related materials. Impact simulations suggest that the distinctive morphologies would not be produced by impact into a solid ice target, but may be explained by impact into an ice layer approximately 10 to 15 km thick overlying a low-viscosity material such as water. The very wide (near antipodal) separation of Callanish and Tyre imply that approximately 10-15 km may have been the global average thickness of the rigid crust of Europa when these impacts occurred. The absence of detectable craters superposed on the interior deposits of Callanish suggests that it is geologically young (< 10(exp 8) years). Hence, it seems likely that our preliminary conclusions about the subsurface structure of Europa apply to the current day.

Moore, Jeffrey M.↗

MeV Au Ion Irradiation in Silicon and Nanocrystalline Zirconia Film Deposited on Silicon Substrate

Nanocrystalline zirconia (ZrO2) film with thickness of 305 nm deposited on a silicon substrate was irradiated with 2 MeV Au ions to different fluences at different temperatures. The implanted ion profiles were measured by time-of-flight secondary ion mass spectrometry (ToF-SIMS) and simulated using the stopping and range of ions inmatter (SRIM) code, respectively. The experimental results show that a large fraction of the incident Au ions penetrates through the ZrO2 film and are deposited into the Si substrate. At the interface of ZrO2 and Si, a sudden decrease of Au concentration is observed due to the much larger scattering cross section of Au in ZrO2 than in Si. The depth profile of the Au ions is measured in both the ZrO2 films and the Si substrates, and the results show that the Au distribution profiles do not exhibit a dependence on irradiation temperature. The local Au concentration increases proportionally with the irradiation fluence, suggesting that no thermal or irradiation-induced redistribution of the implanted Au ions. However, the Au concentration in the ZrO2 films, as determined by SIMS, is considerably lower than that predicted by the SRIM results, and the penetration depth from the SIMS measurements is much deeper than that from the SRIM predictions. These observations can be explained by an overestimation of the electronic stopping power, used in the SRIM program, for heavy incident ions in light targets. Over-estimation of the heavy-ion electronic stopping power may lead to errors in local dose calculation and underestimation of the projected range of slow heavy ions in targets that contain light elements. A quick estimate based on a reduced target density may be used to compensate the overestimation of the electronic stopping power in the SRIM program to provide better ion profile prediction.

Environmental Molecular Sciences Laboratory↗