Verification and Enhancement of VIIRS Day-Night Band (DNB) Power Outage Detection Product

This case study of Hurricane Matthew (October 2016) uses the NASA Short-Term Prediction Research and Transition (SPoRT) Center DNB power outage product (using GSFC VIIRS DNB preliminary Black Marble product, Roman et al.. 2017) and 2013 LandScan Global population data to look for correlations between the post-event %-of-normal radiance and the utility company-reported outage numbers (obtained from EAGLE-1).

DISASTER↗

Weekly Verification of Dosimetric Data for Virtual Wedge Using a 2D Diode Detector Array

A linac manufacturer has recommended that users measure virtual wedge (VW) angle and VW factor as a weekly quality assurance (QA) procedure. The purpose of this study was to investigate whether a 2D diode detector array (MapCHECK{sup TM}) is a useful tool for the verification of dosimetric data for VW. Measurements were performed on 2 linear accelerators (4, 6, and 10 MV) at 10-cm depth for a field size of 10 x 10 cm{sup 2} and with wedge angles of 15, 30, 45, and 60{sup o}. To verify the VW dose distributions generated by the treatment planning system (TPS), we confirmed that agreement between TPS data and measurements were {<=}2% dose difference or 2-mm distance-to-agreement based on American Association of Physicists in Medicine Task Group Report 53 (AAPM TG-53). We present here the results of a 1-year evaluation of VW by means of a 2D diode detector array. The maximum 2-fold standard deviation of the measured wedge angle turned out to be within 1.0, and all measured VW factors to be 1.00 {+-} 0.03. Although >95% of the points measured for 6 and 10 MV were generally within the tolerance of the dose distribution as mentioned above, the percentage of agreement between the measured data for 4 MV and TPS data were somewhat below 90%. We also verified generally good reproducibility for the dose distribution. The 2-D diode detector array was thus found to be useful as a tool for weekly VW QA.

61 RADIATION PROTECTION AND DOSIMETRY↗

Code Verification of the HIGRAD Computational Fluid Dynamics Solver

The purpose of this report is to outline code and solution verification activities applied to HIGRAD, a Computational Fluid Dynamics (CFD) solver of the compressible Navier-Stokes equations developed at the Los Alamos National Laboratory, and used to simulate various phenomena such as the propagation of wildfires and atmospheric hydrodynamics. Code verification efforts, as described in this report, are an important first step to establish the credibility of numerical simulations. They provide evidence that the mathematical formulation is properly implemented without significant mistakes that would adversely impact the application of interest. Highly accurate analytical solutions are derived for four code verification test problems that exercise different aspects of the code. These test problems are referred to as: (i) the quiet start, (ii) the passive advection, (iii) the passive diffusion, and (iv) the piston-like problem. These problems are simulated using HIGRAD with different levels of mesh discretization and the numerical solutions are compared to their analytical counterparts. In addition, the rates of convergence are estimated to verify the numerical performance of the solver. The first three test problems produce numerical approximations as expected. The fourth test problem (piston-like) indicates the extent to which the code is able to simulate a 'mild' discontinuity, which is a condition that would typically be better handled by a Lagrangian formulation. The current investigation concludes that the numerical implementation of the solver performs as expected. The quality of solutions is sufficient to provide credible simulations of fluid flows around wind turbines. The main caveat associated to these findings is the low coverage provided by these four problems, and somewhat limited verification activities. A more comprehensive evaluation of HIGRAD may be beneficial for future studies.

17 WIND ENERGY↗

AN ALMA IMAGING STUDY OF METHYL FORMATE (HCOOCH{sub 3}) IN TORSIONALLY EXCITED STATES TOWARD ORION KL

We recently reported the first identification of rotational transitions of methyl formate (HCOOCH{sub 3}) in the second torsionally excited state toward Orion Kleinmann-Low (KL), observed with the Nobeyama 45 m telescope. In combination with the identified transitions of methyl formate in the ground state and the first torsional excited state, it was found that there is a difference in rotational temperature and vibrational temperature, where the latter is higher. In this study, high spatial resolution analysis by using Atacama Large Millimeter/Submillimeter Array (ALMA) science verification data was carried out to verify and understand this difference. Toward the Compact Ridge, two different velocity components at 7.3 and 9.1 km s{sup −1} were confirmed, while a single component at 7.3 km s{sup −1} was identified toward the Hot Core. The intensity maps in the ground, first, and second torsional excited states have quite similar distributions. Using extensive ALMA data, we determined the rotational and vibrational temperatures for the Compact Ridge and Hot Core by the conventional rotation diagram method. The rotational temperature and vibrational temperatures agree for the Hot Core and for one component of the Compact Ridge. At the 7.3 km s{sup −1} velocity component for the Compact Ridge, the rotational temperature was found to be higher than the vibrational temperature. This is different from what we obtained from the results by using the single-dish observation. The difference might be explained by the beam dilution effect of the single-dish data and/or the smaller number of observed transitions within the limited range of energy levels (≤30 K) of E{sub u} in the previous study.

79 ASTRONOMY AND ASTROPHYSICS↗

The cleanroom case study in the Software Engineering Laboratory: Project description and early analysis

This case study analyzes the application of the cleanroom software development methodology to the development of production software at the NASA/Goddard Space Flight Center. The cleanroom methodology emphasizes human discipline in program verification to produce reliable software products that are right the first time. Preliminary analysis of the cleanroom case study shows that the method can be applied successfully in the FDD environment and may increase staff productivity and product quality. Compared to typical Software Engineering Laboratory (SEL) activities, there is evidence of lower failure rates, a more complete and consistent set of inline code documentation, a different distribution of phase effort activity, and a different growth profile in terms of lines of code developed. The major goals of the study were to: (1) assess the process used in the SEL cleanroom model with respect to team structure, team activities, and effort distribution; (2) analyze the products of the SEL cleanroom model and determine the impact on measures of interest, including reliability, productivity, overall life-cycle cost, and software quality; and (3) analyze the residual products in the application of the SEL cleanroom model, such as fault distribution, error characteristics, system growth, and computer usage.

Green, Scott↗

Gamma Source Verification for GAMSRC and GAMSOR

Nuclear reactors that rely upon the fission reaction have two modes of thermal energy deposition in the reactor system: neutron absorption and gamma absorption. The gamma rays are typically generated by neutron capture reactions or during the fission process which means the primary driver of energy production is of course the neutron interactions. The GAMSOR program was first built in the mid 1980s to properly account for the gamma heating in an operating reactor core on core internals. The GAMSOR code is sequence of DIF3D calculations to compute the neutron and gamma flux and combine them to define both the neutron and gamma heating throughout the modeled domain. The goal of this manuscript is to present the software verification of GAMSOR. The first step of the GAMSOR sequence of calculations involves of a modified version of DIF3D (called DIF3D-GAMSOR) which generates a gamma source distribution for the follow-on DIF3D gamma transport calculation (step 2). This modified version of DIF3D increases the burden of maintenance and verification work on GAMSOR as one must reverify the DIF3D capabilities which is undesirable. Because the calculation of the gamma source is the only unique aspect of GAMSOR beyond the regular DIF3D capabilities, that part was put in a standalone code called GAMSRC such that one can use the verified DIF3D code in step 1 followed by GAMSRC to carry out the same GAMSOR calculation step. As a consequence, this manuscript is focused on verification of the gamma source files generated by GAMSRC. The verification of the modified version of DIF3D (DIF3D-GAMSOR) will be done less rigorously in that it will be verified that it produces the same output that GAMSRC does and thus GAMSRC is equivalent to GAMSOR on the problems studied here. Hand calculations and independent numerical calculations of the gamma source generation are used for the verification work. This work follows the same methodology of GAMSRC. As expected, the results agree well with those calculated by GAMSRC as will be shown.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of Maximal Oxygen Uptake in Active Military Personnel During Treadmill Running

Figueiredo, PS, Looney, DP, Pryor, JL, Doughty, EM, McClung, HL, Vangala, SV, Santee, WR, Beidleman, BA, and Potter, AW. Verification of maximal oxygen uptake in active military personnel during treadmill running. J Strength Cond Res 36(4): 1053–1058, 2022—It is unclear whether verification tests are required to confirm “true” maximal oxygen uptake ($\dot{V}_{o2}$max) in modern warfighter populations. Our study investigated the prevalence of $\dot{V}_{o2}$max attainment in U.S. Army soldiers performing a traditional incremental running test. In addition, we examined the utility of supramaximal verification testing as well as repeated trials for familiarization for accurate $\dot{V}_{o2}$max assessment. Sixteen U.S. Army soldiers (1 woman, 15men; age, 21±2 years; height, 1.73±0.06m; body mass, 71.6±10.1 kg) completed 2 laboratory visits, each with an incremental running test (modified Astrand protocol) and a verification test (110% maximal incremental test speed) on a motorized treadmill. We evaluated $\dot{V}_{o2}$max attainment during incremental testing by testing for the definitive $\dot{V}_{o2}$ plateau using a linear least-squares regression approach. Peak oxygen uptake ($\dot{V}_{o2}$peak) was considered statistically equivalent between tests if the 90% confidence interval around the mean difference was within 62.1 ml·kg -1 ·min -1 . Oxygen uptake plateaus were identified in 14 of 16 volunteers for visit 1 (87.5%) and all 16 volunteers for visit 2 (100%). Peak oxygen uptake was not statistically equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between the incremental test and verification test on visit 1 (2.3 ml·kg -1 ·min -1 , [1.3–3.2]) or visit 2 (1.1 ml·kg -1 ·min -1 [0.2–2.1]). Interestingly, $\dot{V}_{o2}$peak was equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between visits for the incremental tests (0.0ml·kg -1 ·min -1 [-0.8to 0.9]) but not the verification tests (-1.2 ml·kg -1 ·min -1 [-2.2 to -0.2]). Modern U.S. Army soldiers can attain $\dot{V}_{o2}$max by performing a modified Astrand treadmill running test. Additional familiarization and verification tests for confirming $\dot{V}_{o2}$max in healthy active military personnel may be unnecessary.

60 APPLIED LIFE SCIENCES↗

HTTR-GT/H2 test plant - design study on helium gas turbine for the heat utilization system connected to JAEA's HTTR - 18674

In JAEA (Japan Atomic Energy Agency), the program of verification of combined system with helium gas turbine power generation and hydrogen production using nuclear heat which becomes the first in the world, is proceeding. From 2014 to 2015 Japanese Fiscal Year, the design study of the heat utilization system which is arranged in cascade to the heat supply system to supply the hydrogen production system and helium gas turbine system which are installed in the secondary helium-cooling system of High Temperature Engineering Test Reactor (HTTR) was performed and measure technologies of the system have been verified. MHI participated in the design study work of main equipment of this system. This paper reports the result of the design study of a helium gas turbine among those results. Self-sustaining condition (a power generation output is attained) is required for the gas turbine system in three modes of operation such as a) gas turbine individual operation, b) gas turbine + hydrogen production system combined operation, and c) hydrogen production system load loss and gas turbine independent shift operation]. By adopting a multi-stage centrifugal type impeller as a gas turbine and a compressor as a result of design study, it confirmed that all the mode-of-operation self-sustaining can be attained, and can attain a maximum of approx. 1 MWe power generation output on condition of the turbine inlet temperature of 560 deg. C, the turbine flow of 9.8 kg/sec, the compressor inlet temperature of 30 deg. C, and the compression ratio 1.3. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The JOREK non-linear extended MHD code and applications to large-scale instabilities and their control in magnetically confined fusion plasmas

JOREK is a massively parallel fully implicit non-linear extended magneto-hydrodynamic (MHD) code for realistic tokamak X-point plasmas. It has become a widely used versatile simulation code for studying large-scale plasma instabilities and their control and is continuously developed in an international community with strong involvements in the European fusion research programme and ITER organization. This article gives a comprehensive overview of the physics models implemented, numerical methods applied for solving the equations and physics studies performed with the code. A dedicated section highlights some of the verification work done for the code. A hierarchy of different physics models is available including a free boundary and resistive wall extension and hybrid kinetic-fluid models. The code allows for flux-surface aligned iso-parametric finite element grids in single and double X-point plasmas which can be extended to the true physical walls and uses a robust fully implicit time stepping. Particular focus is laid on plasma edge and scrape-off layer (SOL) physics as well as disruption related phenomena. Among the key results obtained with JOREK regarding plasma edge and SOL, are deep insights into the dynamics of edge localized modes (ELMs), ELM cycles, and ELM control by resonant magnetic perturbations, pellet injection, as well as by vertical magnetic kicks. Also ELM free regimes, detachment physics, the generation and transport of impurities during an ELM, and electrostatic turbulence in the pedestal region are investigated. Regarding disruptions, the focus is on the dynamics of the thermal quench (TQ) and current quench triggered by massive gas injection and shattered pellet injection, runaway electron (RE) dynamics as well as the RE interaction with MHD modes, and vertical displacement events. Also the seeding and suppression of tearing modes (TMs), the dynamics of naturally occurring TQs triggered by locked modes, and radiative collapses are being studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-BRB-11: On the Sensitivity of An EPID-Based 3D Dose Verification System to Detect Delivery Errors in VMAT Treatments

Purpose: To investigate the sensitivity of an EPID-based 3D dose verification system to detect delivery errors in VMAT treatments. Methods: For this study 41 EPID-reconstructed 3D in vivo dose distributions of 15 different VMAT plans (H&N, lung, prostate and rectum) were selected. To simulate the effect of delivery errors, their TPS plans were modified by: 1) scaling of the monitor units by ±3% and ±6% and 2) systematic shifting of leaf bank positions by ±1mm, ±2mm and ±5mm. The 3D in vivo dose distributions where then compared to the unmodified and modified treatment plans. To determine the detectability of the various delivery errors, we made use of a receiver operator characteristic (ROC) methodology. True positive and false positive rates were calculated as a function of the γ-parameters γmean, γ1% (near-maximum γ) and the PTV dose parameter ΔD{sub 50} (i.e. D{sub 50}(EPID)-D{sub 50}(TPS)). The ROC curve is constructed by plotting the true positive rate vs. the false positive rate. The area under the ROC curve (AUC) then serves as a measure of the performance of the EPID dosimetry system in detecting a particular error; an ideal system has AUC=1. Results: The AUC ranges for the machine output errors and systematic leaf position errors were [0.64 – 0.93] and [0.48 – 0.92] respectively using γmean, [0.57 – 0.79] and [0.46 – 0.85] using γ1% and [0.61 – 0.77] and [ 0.48 – 0.62] using ΔD{sub 50}. Conclusion: For the verification of VMAT deliveries, the parameter γmean is the best discriminator for the detection of systematic leaf position errors and monitor unit scaling errors. Compared to γmean and γ1%, the parameter ΔD{sub 50} performs worse as a discriminator in all cases.

60 APPLIED LIFE SCIENCES↗

Coupled geomechanical investigation of depletion-induced fault reactivation

Fault reactivation during subsurface fluid production pose significant challenges to safe and sustainable resource extraction. Here, this study presents a three-dimensional coupled geomechanical framework to investigate the processes driving fault reactivation, capturing the interactions between reservoir dynamics and geomechanical responses. Verification against theoretical estimations based on linear poroelasticity confirms the model's capacity in representing reservoir background stress responses. However, the study reveals that relying solely on background stress states can underestimate or overestimate fault reactivation potential, emphasizing the importance of including localized stress perturbations such as differential compaction and stress redistribution. Applied to a fault (M1) inspired by the geological characteristics of the Groningen field, the model shows slip initiation at 2965 m depth with 16.0 MPa depletion, aligning with field observations where seismicity occurred at approximately 3 km depth after 15.8 MPa depletion. Parametric studies reveal: (1) inelastic reservoir compaction delays fault reactivation and mitigates fault slip by reducing stress concentration, (2) higher intermediate in-situ stress magnitudes decrease the Coulomb Failure Stress (CFS) increase rate and reduce fault slip, (3) larger fault offsets amplify shear stress near the offset zone, promoting earlier reactivation and longer rupture propagation, and (4) fault permeability significantly influences pressure diffusion, with low-permeability faults leading to sharper stress changes and earlier fault destabilization. These insights highlight the critical role of geological and mechanical parameters in fault reactivation and provide a predictive framework for mitigating induced seismicity risks.

Coupled geomechanical modeling↗

Development of the engineering design integration (EDIN) system: A computer aided design development

The EDIN (Engineering Design Integration) System which provides a collection of hardware and software, enabling the engineer to perform man-in-the-loop interactive evaluation of aerospace vehicle concepts, was considered. Study efforts were concentrated in the following areas: (1) integration of hardware with the Univac Exec 8 System; (2) development of interactive software for the EDIN System; (3) upgrading of the EDIN technology module library to an interactive status; (4) verification of the soundness of the developing EDIN System; (5) support of NASA in design analysis studies using the EDIN System; (6) provide training and documentation in the use of the EDIN System; and (7) provide an implementation plan for the next phase of development and recommendations for meeting long range objectives.

Glatt, C. R.↗

SU-F-T-229: A Novel Method for EPID-Based In-Vivo Exit Dose Verification for Intensity Modulated Radiotherapy

Purpose: Electronic portal imaging device (EPID) can be used to acquire a two-dimensional exit dose distribution during treatment delivery, thus allowing the in-vivo verification of the dose delivery through a comparison of measured portal images to predicted portal dose images (PDI). The aim of this study was to present a novel method to easily and accurately predict PDI, and to establish an EPID-based in-vivo dose verification method during IMRT treatments. Methods: We developed a model to determine the predicted portal dose at the same plane of the EPID detector location. The Varian EPID (aS1000) positions at 150cm source-to-detector-distance (SDD), and can be used to acquire in-vivo exit dose using Portal Dosimetry (PD) function. Our model was generated to make an equivalent water thickness represent the buildup plate of EPID. The exit dose at extend SDD plane with patient CT data in the beam can be calculated as the predicted PDI in the treatment planning system (TPS). After that, the PDI was converted to the fluence at SDD of 150cm using the inverse square law coded in MATLAB. Five head-and-neck and prostate IMRT patient plans contain 32 fields were investigated to evaluate the feasibility of this new method. The measured EPID image was compared with PDI using the gamma analysis. Results: The average results for cumulative dose comparison were 81.9% and 91.6% for 3%, 3mm and 4%, 4mm gamma criteria, respectively. Results indicate that the patient transit dosimetry predicted algorithm compares well with EPID measured PD doses for test situations. Conclusion: Our new method can be used as an easy and feasible tool for online EPID-based in-vivo dose delivery verification for IMRT treatments. It can be implemented for fast detecting those obvious treatment delivery errors for individual field and patient quality assurance.

60 APPLIED LIFE SCIENCES↗

Daily dose monitoring with atlas-based auto-segmentation on diagnostic quality CT for prostate cancer

Purpose: To evaluate the feasibility of daily dose monitoring using a patient specific atlas-based autosegmentation method on diagnostic quality verification images.Methods: Seven patients, who were treated for prostate cancer with intensity modulated radiotherapy under daily imaging guidance of a CT-on-rails system, were selected for this study. The prostate, rectum, and bladder were manually contoured on the first six and last seven sets of daily verification images. For each patient, three patient specific atlases were constructed using manual contours from planning CT alone (1-image atlas), planning CT plus first three verification CTs (4-image atlas), and planning CT plus first six verification CTs (7-image atlas). These atlases were subsequently applied to the last seven verification image sets of the same patient to generate the auto-contours. Daily dose was calculated by applying the original treatment plans to the daily beam isocenters. The autocontours and manual contours were compared geometrically using the dice similarity coefficient (DSC), and dosimetrically using the dose to 99% of the prostate CTV (D99) and the D5 of rectum and bladder.Results: The DSC of the autocontours obtained with the 4-image atlases were 87.0%± 3.3%, 84.7%± 8.6%, and 93.6%± 4.3% for the prostate, rectum, and bladder, respectively. These indices were higher than those from the 1-image atlases (p < 0.01) and comparable to those from the 7-image atlases (p > 0.05). Daily prostate D99 of the autocontours was comparable to those of the manual contours (p= 0.55). For the bladder and rectum, the daily D5 were 95.5%± 5.9% and 99.1%± 2.6% of the planned D5 for the autocontours compared to 95.3%± 6.7% (p= 0.58) and 99.8%± 2.3% (p < 0.01) for the manual contours.Conclusions: With patient specific 4-image atlases, atlas-based autosegmentation can adequately facilitate daily dose monitoring for prostate cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Shuttle-tethered satellite system definition study. Volume 1: Executive study

The Tethered Satellite System has great prospects for extending orbital operations capability of the Space Transportation System to science, applications, and technology projects not otherwise attainable. The system will installed in the Shuttle Orbiter and will have the capability to deploy a captive satellite up to 100 km away from the Orbiter. Control and retrieval of the satellite are accomplished by means of a tether line connecting the satellite and the cargo bay mounted equipment in the Orbiter. At low satellite altitudes, the system will permit investigations of a duration that could not be pursued with sounding rockets of free-flying spacecraft. The propose of the Shuttle/Tethered Satellite System Definition Study was to produce the preliminary design, preliminary specifications, gross program plans, and program cost estimate for a 1982 operational verification flight. This was accomplished during a fifteen month effort under by the NASA George C. Marshall Space Flight Center (MSFC). The MSFC Phase 1 and related studies demonstrated the feasibility of the system and served as a starting point for the Phase 2 definition study.

Source record↗

Evaluation of MatriXX for IMRT and VMAT dose verifications in peripheral dose regions

Purpose: MatriXX is a two-dimensional ion chamber array designed for IMRT/VMAT (RapidArc, IMAT, etc.) dose verifications. Its dosimetric properties have been characterized for megavoltage beams in a number of studies; however, to the best of the authors' knowledge, there is still a lack of an investigation into its performance in the peripheral or low dose regions. In this work, the authors have carried out a systematic study on this issue. Methods: The authors compare the performance of MatriXX with a cylindrical ion chamber in solid water phantoms in the peripheral dose regions. The comparisons are performed for a number of typical irradiation conditions that involve different gantry and/or MLC motions, field sizes, and distances to the target including static gantry/open fields, static gantry/sweeping MLC gap (mimicking an IMRT delivery), dynamic gantry/oscillating sweeping MLC gap (mimicking a VMAT delivery), as well as clinical IMRT and VMAT plans. Results: MatriXX, when used according to the manufacturer's recommendations, is found to disagree with an ion chamber in peripheral dose regions. This disagreement has been attributed to four types of MatriXX errors, namely, positive bias, over-response to scattered doses, round-off error, and angular dependence, all of which contribute to dose inaccuracies in the peripheral regions. The positive bias, which is independent of the dose level, is cumulative when MatriXX operates in the movie mode. The accumulation is proportional to the number of movie frames (snaps) when the sampling time is greater than 500 ms and is proportional to the overall movie time for a sampling time shorter than 500 ms. This behavior suggests multiple sources of the bias. MatriXX is also found to over-respond to peripheral doses by about 2.0% for the regions investigated in this work (3-15 cm from the field edge), where phantom scatter and collimator scatter dominate. Round-off error is determined to be due to insufficient precision in conversion of the raw signals to MatriXX software data for low doses. Angular dependence is defined as the dose response of MatriXX at different gantry angles. Up to 8% difference in detector response has been observed between 0 deg. and 180 deg. Possible sources of these errors are discussed and a correction method is suggested. With corrections, MatriXX shows good agreement with the ion chamber in all cases involving different gantry and/or MLC dynamics, as well as the clinical plans. For both primary and peripheral doses, MatriXX shows dose linearity down to 2 cGy with an accuracy of within 1% of the local dose. Conclusions: The performance of MatriXX has been systematically evaluated in the peripheral dose regions. Major sources of error associated with MatriXX are identified and a correction method is suggested. This method has been successfully tested using both experimental and clinical plans. In all cases, good agreements between MatriXX and an ion chamber are achieved after corrections. The authors conclude that with proper corrections, MatriXX can be reliably used for peripheral dose measurements within the ranges studied.

60 APPLIED LIFE SCIENCES↗

Gamma Source Verification for GAMSRC and GAMSOR

Nuclear reactors that rely upon the fission reaction have two modes of thermal energy deposition in the reactor system: neutron absorption and gamma absorption. The gamma rays are typically generated by neutron capture reactions or during the fission process which means the primary driver of energy production is of course the neutron interactions. The GAMSOR program was first built in the mid 1980s to properly account for the gamma heating in an operating reactor core on core internals. The GAMSOR code is sequence of DIF3D calculations to compute the neutron and gamma flux and combine them to define both the neutron and gamma heating throughout the modeled domain. The goal of this manuscript is to present the software verification of GAMSOR. The first step of the GAMSOR sequence of calculations involves of a modified version of DIF3D (called DIF3D-GAMSOR) which generates a gamma source distribution for the follow-on DIF3D gamma transport calculation (step 2). This modified version of DIF3D increases the burden of maintenance and verification work on GAMSOR as one must reverify the DIF3D capabilities which is undesirable. Because the calculation of the gamma source is the only unique aspect of GAMSOR beyond the regular DIF3D capabilities, that part was put in a standalone code called GAMSRC such that one can use the verified DIF3D code in step 1 followed by GAMSRC to carry out the same GAMSOR calculation step. As a consequence, this manuscript is focused on verification of the gamma source files generated by GAMSRC. The verification of the modified version of DIF3D (DIF3D-GAMSOR) will be done less rigorously in that it will be verified that it produces the same output that GAMSRC does and thus GAMSRC is equivalent to GAMSOR on the problems studied here. Hand calculations and independent numerical calculations of the gamma source generation are used for the verification work. This work follows the same methodology of GAMSRC. As expected, the results agree well with those calculated by GAMSRC as will be shown.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Patient-Specific 3D Pretreatment and Potential 3D Online Dose Verification of Monte Carlo-Calculated IMRT Prostate Treatment Plans

Purpose: Fast and reliable comprehensive quality assurance tools are required to validate the safety and accuracy of complex intensity-modulated radiotherapy (IMRT) plans for prostate treatment. In this study, we evaluated the performance of the COMPASS system for both off-line and potential online procedures for the verification of IMRT treatment plans. Methods and Materials: COMPASS has a dedicated beam model and dose engine, it can reconstruct three-dimensional dose distributions on the patient anatomy based on measured fluences using either the MatriXX two-dimensional (2D) array (offline) or a 2D transmission detector (T2D) (online). For benchmarking the COMPASS dose calculation, various dose-volume indices were compared against Monte Carlo-calculated dose distributions for five prostate patient treatment plans. Gamma index evaluation and absolute point dose measurements were also performed in an inhomogeneous pelvis phantom using extended dose range films and ion chamber for five additional treatment plans. Results: MatriXX-based dose reconstruction showed excellent agreement with the ion chamber (<0.5%, except for one treatment plan, which showed 1.5%), film ({approx}100% pixels passing gamma criteria 3%/3 mm) and mean dose-volume indices (<2%). The T2D based dose reconstruction showed good agreement as well with ion chamber (<2%), film ({approx}99% pixels passing gamma criteria 3%/3 mm), and mean dose-volume indices (<5.5%). Conclusion: The COMPASS system qualifies for routine prostate IMRT pretreatment verification with the MatriXX detector and has the potential for on-line verification of treatment delivery using T2D.

62 RADIOLOGY AND NUCLEAR MEDICINE↗