Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Optimization of Helium Vessel Design for ILC Cavities

The ILC (International Linear Collider) is a proposed new major particle accelerator. It consists of two 20 km long linear accelerators colliding electrons and positrons at an energy exceeding 500 GeV, Achieving this collision energy while keeping reasonable accelerator dimensions requires the use of high electric field superconducting cavities as the main acceleration element. These cavities are operated at l.3 GHz inside an appropriate container (He vessel) at temperatures as low as 1.4 K using superfluid Helium as the refrigerating medium. The purpose of this thesis, in the context of the ILC R&D activities currently in progress at Fermilab (Fermi National Accelerator Laboratory), is the mechanical study of an ILC superconducting cavity and Helium vessel prototype. The main goals of these studies are the determination of the limiting working conditions of the whole He vessel assembly, the simulation of the manufacturing process of the cavity end-caps and the assessment of the Helium vessel's efficiency. In addition this thesis studies the requirements to certify the compliance with the ASME Code of the whole cavity/vessel assembly. Several Finite Elements Analyses were performed by the candidate himself in order to perform the studies listed above and described in detail in Chapters 4 through 8. ln particular the candidate has developed an improved procedure to obtain more accurate results with lower computational times. These procedures will be accurately described in the following chapters. After an introduction that briefly describes the Fennilab and in particular the Technical Division (where all the activities concerning with this thesis were developed), the first part of this thesis (Chapters 2 and 3) explains some of the main aspects of modem particle accelerators. Moreover it describes the most important particle accelerators working at the moment and the basic features of the ILC project. Chapter 4 describes all the activities that were done to certify the compliance of the Helium vessel and the cavity to the ASME code standard. After briefly recalling to the main contents of the the ASME Code (Sections II and Vlll - Division ll), the procedure used for finding all relevant stresses and comparing the obtained results with the maximum values allowed are explained. This part also includes the buckling verification of the cavity. In Chapter 5 the manufacturing process of the cavity end-caps, whose function is to link the Helium vessel with the cavity, is studied. The present configuration of the dies is described and the manufacturing process is simulated in order to explain the origin of some defects fol.llld on real parts. Finally a new design of the dies is proposed and the resulting deformed piece is compared with the design requirements. Chapter 6 describes a finite elements analysis to assess the efficiency and the stiffness of the Helium vessel. Furthermore the results of the optimization of the Helium vessel (in order to increase the value of the efficiency) are reported. The same stiffness analysis is used in Chapter 7 for the Blade-Tuner study. After a description of this tuner and of its function, the preliminary analyses done to confirm the results provided by the vendor are described and then its limiting load conditions are found. Chapter 8 shows a study of the resistance of all the welds present in between the cavity and the end-cap and between the end-caps and the He vessel for a smaller superconducting cavity operating at 3.9 GHz. Finally Chapter 9 briefly describes some R&D activities in progress at INFN (Section of Pisa) and Fermilab that could produce significant cost reductions of the Helium vessel design. All the finite elements analyses contained and described in this thesis made possible the certification of the whole superconducting cavity-Helium vessel assembly at Fermilab. Furthermore they gave several useful indications to the Fermilab staff to improve the performance of the Helium vessel by modifying some design parameters or refining the manufacturing processes.

43 PARTICLE ACCELERATORS↗

Code Verification and Solution Verification framework in pin-resolved neutron transport code MPACT

Program verification in scientific computing encompasses the application of formal and mathematical techniques to a scientific computing code for its credibility, accuracy, and validity. Code Verification identifies bugs and performance issues in the software development stage. Solution Verification assesses the applicability of the code and the accuracy of the solution to problems of interest. Both activities utilize application cases and quantify the error against prescribed acceptance criteria. However, simply executing more application cases does not guarantee stronger or more comprehensive credibility. Here, we establish a verification framework that involves Code Verification and Solution Verification, both of which work together such that the overarching goal of “converge to the correct answer for the intended application” can be reasonably inferred. The application of such a verification framework is demonstrated using the pin-resolved neutron transport code MPACT, where standard unit tests and regression tests are covered, and where the Method of Exact Solutions and the Method of Manufactured Solutions are successfully used. Additionally, the applicability of Method of Manufactured Solutions is extended to the OECD/NEA C5G7 benchmark problems of practical material and geometric configurations. Solution Verification activities are demonstrated on a practical hierarchy of application models of increasing complexity ranging from 2D pin cell problems to 3D assembly problems. The convergence behavior and rate of convergence with respect to each individual variable are studied and provided. This framework can be adapted broadly to other fields involving scientific computing codes.

97 MATHEMATICS AND COMPUTING↗

Development of a multi-modal Monte-Carlo radiation treatment planning system combined with PHITS

A new multi-modal Monte-Carlo radiation treatment planning system is under development at Japan Atomic Energy Agency. This system (developing code: JCDS-FX) builds on fundamental technologies of JCDS. JCDS was developed by JAEA to perform treatment planning of boron neutron capture therapy (BNCT) which is being conducted at JRR-4 in JAEA. JCDS has many advantages based on practical accomplishments for actual clinical trials of BNCT at JRR-4, the advantages have been taken over to JCDS-FX. One of the features of JCDS-FX is that PHITS has been applied to particle transport calculation. PHITS is a multipurpose particle Monte-Carlo transport code, thus application of PHITS enables to evaluate doses for not only BNCT but also several radiotherapies like proton therapy. To verify calculation accuracy of JCDS-FX with PHITS for BNCT, treatment planning of an actual BNCT conducted at JRR-4 was performed retrospectively. The verification results demonstrated the new system was applicable to BNCT clinical trials in practical use. In framework of R and D for laser-driven proton therapy, we begin study for application of JCDS-FX combined with PHITS to proton therapy in addition to BNCT. Several features and performances of the new multimodal Monte-Carlo radiotherapy planning system are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Steps towards verification and validation of the Fetch code for Level 2 analysis, design, and optimization of aqueous homogeneous reactors

Babcock and Wilcox Technical Services Group (B and W) has identified aqueous homogeneous reactors (AHRs) as a technology well suited to produce the medical isotope molybdenum 99 (Mo-99). AHRs have never been specifically designed or built for this specialized purpose. However, AHRs have a proven history of being safe research reactors. In fact, in 1958, AHRs had 'a longer history of operation than any other type of research reactor using enriched fuel' and had 'experimentally demonstrated to be among the safest of all various type of research reactor now in use [1].' While AHRs have been modeled effectively using simplified 'Level 1' tools, the complex interactions between fluids, neutronics, and solid structures are important (but not necessarily safety significant). These interactions require a 'Level 2' modeling tool. Imperial College London (ICL) has developed such a tool: Finite Element Transient Criticality (FETCH). FETCH couples the radiation transport code EVENT with the computational fluid dynamics code (Fluidity), the result is a code capable of modeling sub-critical, critical, and super-critical solutions in both two-and three-dimensions. Using FETCH, ICL researchers and B and W engineers have studied many fissioning solution systems include the Tokaimura criticality accident, the Y12 accident, SILENE, TRACY, and SUPO. These modeling efforts will ultimately be incorporated into FETCH'S extensive automated verification and validation (V and V) test suite expanding FETCH'S area of applicability to include all relevant physics associated with AHRs. These efforts parallel B and W's engineering effort to design and optimize an AHR to produce Mo99. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A comparison between radiation therapists and medical specialists in the use of kilovoltage cone-beam computed tomography scans for potential lung cancer radiotherapy target verification and adaptation

Target volume matching using cone-beam computed tomography (CBCT) is the preferred treatment verification method for lung cancer in many centers. However, radiation therapists (RTs) are trained in bony matching and not soft tissue matching. The purpose of this study was to determine whether RTs were equivalent to radiation oncologists (ROs) and radiologists (RDs) in alignment of the treatment CBCT with the gross tumor volume (GTV) defined at planning and in delineating the GTV on the treatment CBCT, as may be necessary for adaptive radiotherapy. In this study, 10 RTs, 1 RO, and 1 RD performed a manual tumor alignment and correction of the planning GTV to a treatment CBCT to generate an isocenter correction distance for 15 patient data sets. Participants also contoured the GTV on the same data sets. The isocenter correction distance and the contoured GTVs from the RTs were compared with the RD and RO. The mean difference in isocenter correction distances was 0.40 cm between the RO and RD, 0.51 cm between the RTs, and RO and 0.42 cm between the RTs and RD. The 95% CIs were smaller than the equivalence limit of 0.5 cm, indicating that the RTs were equivalent to the RO and RD. For GTV delineation comparisons, the RTs were not found to be equivalent to the RD or RO. The alignment of the planning defined GTV and treatment CBCT using soft tissue matching by the RTs has been shown to be equivalent to those by the RO and RD. However, tumor delineation by the RTs on the treatment CBCT was not equivalent to that of the RO and RD. Thus, it may be appropriate for RTs to undertake soft tissue alignment based on CBCT; however, further investigation may be necessary before RTs undertake delineation for adaptive radiotherapy purposes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nonlinear verification of a linear critical gradient model for energetic particle transport by Alfven eigenmodes

Here, a “stiff transport” critical gradient model of energetic particle (EP) transport by EPdriven Alfven eigenmodes (AEs) is verified against local nonlinear gyrokinetic simulations of a well-studied beam-heated DIII-D discharge 146102. A greatly simplifying linear “recipe” for the limiting EP-density gradient (critical gradient) is considered here. In this recipe, the critical gradient occurs when the AE linear growth rate, driven mainly by the EP gradient, exceeds the ion temperature gradient (ITG) or trapped electron mode (TEM) growth rate, driven by the thermal plasma gradient, at the same toroidal mode number (n) as the AE peak growth, well below the ITG/TEM peak n. This linear recipe for the critical gradient is validated against the critical gradient determined from far more expensive local nonlinear simulations in the gyrokinetic code GYRO, as identified by the point of transport runaway when all driving gradients are held fixed. The reduced linear model is extended to include the stabilization from equilibrium E×B velocity shear. The nonlinear verification unambiguously endorses one of two alternative recipes proposed in Ref. 1: the EP-driven AE growth rate should be determined with rather than without added thermal plasma drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FY-09 Report: Experimental Validation of Stratified Flow Phenomena, Graphite Oxidation, and Mitigation Strategies of Air Ingress Accidents

The Idaho National Laboratory (INL), under the auspices of the U.S. Department of Energy, is performing research and development that focuses on key phenomena important during potential scenarios that may occur in the Next Generation Nuclear Plant (NGNP)/Gen-IV very high temperature reactor (VHTR). Phenomena Identification and Ranking Studies to date have identified that an air ingress event following on the heels of a VHTR depressurization is a very important incident. Consequently, the development of advanced air ingress-related models and verification and validation data are a very high priority for the NGNP Project. Following a loss of coolant and system depressurization incident, air will enter the core through the break, leading to oxidation of the in-core graphite structure and fuel. If this accident occurs, the oxidation will accelerate heat-up of the bottom reflector and the reactor core and will eventually cause the release of fission products. The potential collapse of the core bottom structures causing the release of CO and fission products is one of the concerns. Therefore, experimental validation with the analytical model and computational fluid dynamic (CFD) model developed in this study is very important. Estimating the proper safety margin will require experimental data and tools, including accurate multidimensional thermal-hydraulic and reactor physics models, a burn-off model, and a fracture model. It will also require effective strategies to mitigate the effects of oxidation. The results from this research will provide crucial inputs to the INL NGNP/VHTR Methods Research and Development project. The second year of this three-year project (FY-08 to FY-10) was focused on (a) the analytical, CFD, and experimental study of air ingress caused by density-driven, stratified, countercurrent flow; (b) advanced graphite oxidation experiments and modeling; (c) experimental study of burn-off in the core bottom structures, (d) implementation of advanced graphite oxidation models into the GAMMA code, and (f) air ingress and oxidation mitigation analyses of the whole air-ingress scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-490: Independent Three-Dimensional (3D) Dose Verification of VMAT/SBRT Using EPID and Cloud Computing

Purpose: Dosimetric verification of VMAT/SBRT is currently performed on one or two planes in a phantom with either film or array detectors. A robust and easy-to-use 3D dosimetric tool has been sought since the advent of conformal radiation therapy. Here we present such a strategy for independent 3D VMAT/SBRT plan verification system by a combined use of EPID and cloud-based Monte Carlo (MC) dose calculation. Methods: The 3D dosimetric verification proceeds in two steps. First, the plan was delivered with a high resolution portable EPID mounted on the gantry, and the EPID-captured gantry-angle-resolved VMAT/SBRT field images were converted into fluence by using the EPID pixel response function derived from MC simulations. The fluence was resampled and used as the input for an in-house developed Amazon cloud-based MC software to reconstruct the 3D dose distribution. The accuracy of the developed 3D dosimetric tool was assessed using a Delta4 phantom with various field sizes (square, circular, rectangular, and irregular MLC fields) and different patient cases. The method was applied to validate VMAT/SBRT plans using WFF and FFF photon beams (Varian TrueBeam STX). Results: It was found that the proposed method yielded results consistent with the Delta4 measurements. For points on the two detector planes, a good agreement within 1.5% were found for all the testing fields. Patient VMAT/SBRT plan studies revealed similar level of accuracy: an average γ-index passing rate of 99.2± 0.6% (3mm/3%), 97.4± 2.4% (2mm/2%), and 72.6± 8.4 % ( 1mm/1%). Conclusion: A valuable 3D dosimetric verification strategy has been developed for VMAT/SBRT plan validation. The technique provides a viable solution for a number of intractable dosimetry problems, such as small fields and plans with high dose gradient.

60 APPLIED LIFE SCIENCES↗

Development of MELCOR 2.1 Guidance Report for LPF Applications

A complex nuclear facility includes several pathways that can transport accidentally released materials throughout the facility and potentially to the exterior environment. To model and estimate material transport and possible release as a source term from a U.S. Department of Energy (DOE) nuclear facility requires proficiency in applying simulation tools, such as the MELCOR code. DOE has designated MELCOR version 1.8.5, an obsolete version, as a DOE Tool Box code in its Central Registry. A leak path factor (LPF) guidance report written in 2004 did not include experimental validation data. Using an obsolete version of MELCOR requires additional verification and validations, which may be cost prohibitive. Without any developer support and lack of experimental data validation, it is difficult to justify to regulators that the calculated source term with the obsolete version of MELCOR from the facility is accurate and defensible. The goal of this work is to replace the obsolete guidance report with MELCOR 2.1 with experimental validations. In this paper, we will present our approach to develop a MELCOR 2.1 guidance report for LPF applications. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

In vivo real-time dosimetric verification in high dose rate prostate brachytherapy

Purpose: To evaluate the performance of a diode array in the routine verification of planned dose to points inside the rectum from prostate high dose rate (HDR) brachytherapy using a real-time planning system. Methods: A dosimetric study involving 28 patients was undertaken where measured doses received during treatment were compared to those calculated by the treatment planning system (TPS). After the ultrasound imaging required for treatment planning had been recorded, the ultrasound probe was replaced with a geometric replica that contained an 8 mm diameter cylindrical cavity in which a PTW diode array type 9112 was placed. The replica probe was then positioned inside the rectum with the individual diode positions determined using fluoroscopy. Dose was then recorded during the patients' treatment and compared to associated coordinates in the planning system. Results: Factors influencing diode response and experimental uncertainty were initially investigated to estimate the overall uncertainty involved in dose measurements, which was determined to be {+-}10%. Data was acquired for 28 patients' first fractions, 11 patients' second fractions, and 13 patients' third fractions with collection dependent upon circumstances. Deviations between the diode measurements and predicted values ranged from -42% to +35% with 71% of measurements experiencing less than a 10% deviation from the predicted values. If the {+-}10% measurement uncertainty was combined with a tolerated dose discrepancy of {+-}10% then over 95% of the diode results exhibited agreement with the calculated data to within {+-}20%. It must also be noted that when large dose discrepancies were apparent they did not necessarily occur for all five diodes in the one measurement. Conclusions: This technique provided a method that could be utilized to detect gross errors in dose delivery of a real-time prostate HDR plan. Limitations in the detection system used must be well understood if meaningful results are to be achieved.

61 RADIATION PROTECTION AND DOSIMETRY↗

Verification of Bison fission product species conservation under TRISO reactor conditions

When assessing the reliability and predictive capabilities of a simulation tool, code verification is used to ensure that the implemented numerical algorithm is a faithful representation of its underlying mathematical model, including partial differential or integral equations, initial and boundary conditions, and auxiliary relationships. During this process, numerical results in a discrete solution are compared to the analytical solution of the mathematical model. Here, in this paper, the code verification process is applied to one-dimensional spatiotemporal problems that exercise partial differential equation governing the conservation of fission product species (or mass diffusion). Numerical experiments were performed in the Bison fuel performance code to evaluate its predictive capability under various TRISO reactor conditions such as base irradiation and safety heating test conditions for either short- or long-lived fission product species, as well as a case concerning evaporation from the outer surface of a particle. The code predictions were compared with the expected exact results obtained from the analytical expressions, and the fact that they demonstrate the correct analytical behavior provides strong evidence of proper numerical algorithm implementation.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-624: Quantitative Evaluation of 2D Versus 3D Dosimetry for Stereotactic Volumetric Modulated Arc Delivery Using COMPASS

Purpose: The purpose of this study was to evaluate quantitatively 2D versus 3D dosimetry for stereotactic volumetric modulated arc delivery using COMPASS with 2D array. Methods: Twenty-five patients CT images and RT structures of different sites like brain, head and neck, thorax, abdomen and spine were taken from Multiplan planning system for this study. All these patients underwent radical stereotactic treatment in Cyberknife. For each patient, linac based VMAT stereotactic plans were generated in Monaco TPS v 3.1 using Elekta Beam Modulator MLC. Dose prescription was in the range of 5-20Gy/fraction.TPS calculated VMAT plan delivery accuracy was quantitatively evaluated with COMPASS measured dose and calculated dose based on DVH metrics. In order to ascertain the potential of COMPASS 3D dosimetry for stereotactic plan delivery, 2D fluence verification was performed with MatriXX using Multicube. Results: For each site, D{sub 9} {sub 5} was achieved with 100% of prescription dose with maximum 0.05SD. Conformity index (CI) was observed closer to 1.15 in all cases. Maximum deviation of 2.62 % was observed for D{sub 9} {sub 5} when compared TPS versus COMPASS measured. Considerable deviations were observed in head and neck cases compare to other sites. The maximum mean and standard deviation for D{sub 9} {sub 5}, average target dose and average gamma were -0.78±1.72, -1.10±1.373 and 0.39±0.086 respectively. Numbers of pixels passing 2D fluence verification were observed as a mean of 99.36% ±0.455 SD with 3% dose difference and 3mm DTA. For critical organs in head and neck cases, significant dose differences were observed in 3D dosimetry while the target doses were matched well within limit in both 2D and 3D dosimetry. Conclusion: The quantitative evaluations of 2D versus 3D dosimetry for stereotactic volumetric modulated plans showed the potential of highlighting the delivery errors. This study reveals that COMPASS 3D dosimetry is an effective tool for patient specific quality assurance compared to 2D fluence verification.

60 APPLIED LIFE SCIENCES↗

GALE 3.2 Verification Report

This report is documentation of the verification activities that have been performed on GALE-3.2 to ensure that the codes meet the requirements and specifications set forth by NRC and that the code meets its intended purpose. These activities are done in accordance with the GALE Software Quality Assurance Plan (PNNL-24249) and the GALE Configuration Management & Maintenance Plan (PNNL-24250). These two plans meet the requirements set for by both PNNL software quality assurance requirements and the NRC’s Software Quality Assurance Program and Guidelines (NUREG/BR-0167). The verification activities are documented to conform to Level 2 requirements of NUREG/BR-0167. Verifications were performed for both GALE-3.2 BWR and GALE-3.2 PWR Codes. The GALE 3.2 BWR and PWR codes are computerized mathematical models for calculating the releases of radioactive material in gaseous and liquid effluents. These computer codes are tools which can be used to determine conformance with the requirements of Appendix I to Title 10, Part 50 of the Code of Federal Regulations (10 CFR 50).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantifying deformation during Zry-4 burst testing: a comparison of BISON and a combined in-situ digital image correlation and infrared thermography method

The development and verification of nuclear fuel-cladding performance codes require extensive testing to establish empirical correlations, necessitating more accelerated testing methods that can replace large validation studies. Here, in the present work, a technique was developed and implemented to experimentally quantify the relationship between temperature, cladding internal pressure, and strain in-situ during a burst test, with the specific aim of generating data for code validation and model refinement. Digital image correlation was used to measure hoop, axial, and radial strain, and infrared thermography to quantify axial temperature gradients. Several key experimental modifications to traditional LOCA burst testing were necessary, but are shown to effectively have little impact on burst temperatures. The time/temperature dependent pressure and time/spatially dependent thermal gradient data were used with BISON to simulate cladding burst and strain rates. Although the measured DIC strains reach appreciable amounts at slightly lower temperatures than BISON simulated strains, there is good agreement between the measured and simulated strains in terms of magnitude and rates leading up to burst. However, in the few seconds prior to and during burst, the BISON simulated strains are significantly lower than the measured strains, indicating the potential for model improvement. The combined experiment and simulation technique may be applied to any new cladding concept to accelerate fuel qualification.

36 MATERIALS SCIENCE↗

Magnetic flux noise in superconducting qubits and the gap states continuum

In the present study we investigate the selected local aspects of the metal-induced gap states (MIGSs) at the disordered metal–insulator interface, that were previously proposed to produce magnetic moments responsible for the magnetic flux noise in some of the superconducting qubit modalities. Our analysis attempts to supplement the available studies and provide new theoretical contribution toward their validation. In particular, we explicitly discuss the behavior of the MIGSs in the momentum space as a function of the onsite energy deviation, that mimics random potential disorder at the interface in the local approximation. It is found, that when the difference between the characteristic electronic potentials in the insulator increases, the corresponding MIGSs become more localized. This effect is associated with the increasing degree of the potential disorder that was earlier observed to produce highly localized MIGSs in the superconducting qubits. At the same time, the presented findings show that the disorder-induced localization of the MIGSs can be related directly to the decay characteristics of these states as well as to the bulk electronic properties of the insulator. As a result, our study reinforces plausibility of the previous corresponding investigations on the origin of the flux noise, but also allows to draw future directions toward their better verification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of 7050 Wrought Aluminum Alloy Wheel Die Forging and its Defects Analysis based on DEFORM

Defects such as folding, intercrystalline cracking and flow lines outcrop are very likely to occur in the forging of aluminum alloy. Moreover, it is difficult to achieve the optimal set of process parameters just by trial and error within an industrial environment. In producing 7050 wrought aluminum alloy wheel, a rigid-plastic finite element method (FEM) analysis has been performed to optimize die forging process. Processing parameters were analyzed, focusing on the effects of punch speed, friction factor and temperature. Meanwhile, mechanism as well as the evolution with respect to the defects of the wrought wheel was studied in details. From an analysis of the results, isothermal die forging was proposed for producing 7050 aluminum alloy wheel with good mechanical properties. Finally, verification experiment was carried out on hydropress.

36 MATERIALS SCIENCE↗

Collision prediction software for radiotherapy treatments

Purpose: This work presents a method of collision predictions for external beam radiotherapy using surface imaging. The present methodology focuses on collision prediction during treatment simulation to evaluate the clearance of a patient’s treatment position and allow for its modification if necessary. Methods: A Kinect camera (Microsoft, Redmond, WA) is used to scan the patient and immobilization devices in the treatment position at the simulator. The surface is reconstructed using the SKANECT software (Occipital, Inc., San Francisco, CA). The treatment isocenter is marked using simulated orthogonal lasers projected on the surface scan. The point cloud of this surface is then shifted to isocenter and converted from Cartesian to cylindrical coordinates. A slab models the treatment couch. A cylinder with a radius equal to the normal distance from isocenter to the collimator plate, and a height defined by the collimator diameter is used to estimate collisions. Points within the cylinder clear through a full gantry rotation with the treatment couch at 0° , while points outside of it collide. The angles of collision are reported. This methodology was experimentally verified using a mannequin positioned in an alpha cradle with both arms up. A planning CT scan of the mannequin was performed, two isocenters were marked in PINNACLE, and this information was exported to AlignRT (VisionRT, London, UK)—a surface imaging system for patient positioning. This was used to ensure accurate positioning of the mannequin in the treatment room, when available. Collision calculations were performed for the two treatment isocenters and the results compared to the collisions detected the room. The accuracy of the Kinect-Skanect surface was evaluated by comparing it to the external surface of the planning CT scan. Results: Experimental verification results showed that the predicted angles of collision matched those recorded in the room within 0.5°, in most cases (largest deviation −1.2°). The accuracy study for the Kinect-Skanect surface showed an average discrepancy between the CT external contour and the surface scan of 2.2 mm. Conclusions: This methodology provides fast and reliable collision predictions using surface imaging. The use of the Kinect-Skanect system allows for a comprehensive modeling of the patient topography including all the relevant anatomy and immobilization devices that may lead to collisions. The use of this tool at the treatment simulation stage may allow therapists to evaluate the clearance of a patient’s treatment position and optimize it before the planning CT scan is performed. This can allow for safer treatments for the patients due to better collision predictions and improved clinical workflow by minimizing replanning and resimulations due to unforeseen clearance issues.

60 APPLIED LIFE SCIENCES↗

Machine Learning and Data Mining for Comprehensive Test Ban Treaty Monitoring

The Comprehensive Test Ban Treaty (CTBT) is gaining renewed attention in light of growing worldwide interest in mitigating risks of nuclear weapons proliferation and testing. Since the International Monitoring System (IMS) installed the first suite of sensors in the late 1990's, the IMS network has steadily progressed, providing valuable support for event diagnostics. This progress was highlighted at the recent International Scientific Studies (ISS) Conference in Vienna in June 2009, where scientists and domain experts met with policy makers to assess the current status of the CTBT Verification System. A strategic theme within the ISS Conference centered on exploring opportunities for further enhancing the detection and localization accuracy of low magnitude events by drawing upon modern tools and techniques for machine learning and large-scale data analysis. Several promising approaches for data exploitation were presented at the Conference. These are summarized in a companion report. In this paper, we introduce essential concepts in machine learning and assess techniques which could provide both incremental and comprehensive value for event discrimination by increasing the accuracy of the final data product, refining On-Site-Inspection (OSI) conclusions, and potentially reducing the cost of future network operations.

99 GENERAL AND MISCELLANEOUS↗