Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Angular distribution of atoms emitted from a SrZrO{sub 3} target by laser ablation under different laser fluences and oxygen pressures

Angular distributions of atoms emitted by laser ablation of perovskite-type oxide SrZrO{sub 3} have been investigated using electron probe microanalysis with wavelength-dispersive spectroscopy and charge-coupled device photography with an interference filter. Each constituent element has been analyzed as a two-modal distribution composed of a broad cos{sup m} {theta} distribution and a narrow cos{sup n} {theta} distribution. The exponent n characterizes the component of laser ablation while the exponent m characterizes that of thermal evaporation, where a larger n or m means a narrower angular distribution. In vacuum, O (n=6) showed a broader distribution than those of Sr (n=16) and Zr (n=17), and Sr{sup +} exhibited a spatial distribution similar to that of Sr. As the laser fluence was increased from 1.1 to 4.4 J/cm{sup 2}, the angular distribution of Sr became narrower. In the laser fluence range of 1.1-4.4 J/cm{sup 2}, broadening of the angular distribution of Sr was observed only at the fluence of 1.1 J/cm{sup 2} under the oxygen pressure of 10 Pa. Monte Carlo simulations were performed to estimate approximately the energy of emitted atoms, focusing on the broadening of the angular distribution under the oxygen pressure of 10 Pa. The energies of emitted atoms were estimated to be 1-20 eV for the laser fluence of 1.1 J/cm{sup 2}, and more than 100 eV for 2.2 and 4.4 J/cm{sup 2}.

36 MATERIALS SCIENCE↗

Fabrication of freestanding LiNbO{sub 3} thin films via He implantation and femtosecond laser ablation

The authors report using a combination of ion-implantation exfoliation and femtosecond laser ablation to fabricate thin (micrometers-thick) single-crystal films of a complex oxide, LiNbO{sub 3}. The process physics for the method is bounded by the threshold for ablation and the onset of laser thermal outdiffusion of the implanted He used in exfoliation selective etching.

36 MATERIALS SCIENCE↗

Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. Conclusions: In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of damage and ablation dynamics of multilayer dielectric films initiated by few-cycle pulses versus longer femtosecond pulses

The importance of high intensity few- to single-cycle laser pulses for applications such as intense isolated attosecond pulse generation is constantly growing, and with the breakdown of the monochromatic approximation in field ionization models, the few-cycle pulse (FCP) interaction with solids near the damage threshold has ushered a new paradigm of nonperturbative light–matter interaction. In this Letter, we systematically study and contrast how femtosecond laser-induced damage and ablation behaviors of SiO 2 /HfO 2 -based reflective multilayer dielectric thin film systems vary between FCP and 110 fs pulses. With time-resolved surface microscopy and ex situ analysis, we show that there are distinct differences in the interaction depending on the pulse duration, specifically in the “blister” morphology formation at lower fluences (damage) as well as in the dynamics of debris formation at higher fluences (ablation).

42 ENGINEERING↗

Evaluation of the RADCHEM Diagnostic as an Assessment of Fuel-Ablator Mix and Fuel Rho R

The RADCHEM diagnostic consists of the collection of both gaseous and solid debris samples following a NIF shot. Small amounts of detector elements are doped into the inner-most layer of the ablator shell, which then undergo nuclear activations with neutrons and/or charged particles that are produced during the fusion process. Reaction products are collected and their radioactive decays are counted in order to determine the number and type of activations that occurred. Simulations have shown that these data can then be correlated to several capsule parameters, including fuel rhoR ({rho}R), implosion asymmetry, and fuel-ablator mix. In this document we present a brief summary of the simulations that have been performed, and evalute the ability of RADCHEM to assess capsule performance. A longer, follow-on document, which will include more details on the specific simulations and experimental techniques that have been considered for RADCHEM, is currently being written.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Laser Ablation, Absorbance Ratio Spectrometry (LAARS) Assay Performance Study (FY2018 Annual Report)

The International Atomic Energy Agency (IAEA) has a long history of testing and using laser-based technologies for a variety of safeguards applications. Notable laser-based on-site applications include: 3-dimensional laser range (3DLR) instruments, used for facility design information and verification (DIV); laser measurements to verify unique labels and detect signs of tampering; and laser spectroscopy, for non-contact process monitoring. The IAEA is also evaluating analytical laboratory instruments, such as laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) for interrogating individual particles to determine uranium isotopic ratios in collected environment samples. Recent laser technology advancements will continue to fuel future IAEA adoption of new and novel laser-based safeguards tools. Pacific Northwest National Laboratory (PNNL) is developing one such tool, called the Laser Ablation, Absorbance Ratio Spectrometry (LAARS) technology, which is designed to provide high-fidelity 235 U/ 238 U isotope ratio measurements to support either on-site enrichment plant or off-site laboratory destructive assay (DA). Analyzing uranium hexafluoride (UF 6 ) DA samples on-site by LAARS could provide early indication of discrepancies with operator declarations during physical inventory verifications, so that such discrepancies could be addressed immediately, rather than after off-site analysis is completed. The IAEA is also seeking on-site DA options, because sample shipping time can be long and evolving restrictions on radioactive/corrosive material shipments may increasingly limit the IAEA’s ability to easily transport UF 6 samples. Routine on-site LAARS analysis could provide timely assay results and reduce the DA sample shipment inventory to just those needed for more definitive determination. A laboratory-based LAARS instrument could also provide rapid, cost-effective prescreening of selected DA samples shipped to the IAEA’s Nuclear Materials Laboratory in Seibersdorf, Austria. PNNL has also developed a complementary UF 6 sampling technology and method, called the Single-Use Destructive Assay (SUDA) sampler to easily collect DA samples that are ideal for on-site analysis by LAARS. Combining the LAARS and SUDA sampler technologies could provide a powerful new on-site DA option for the IAEA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryo-Ablation Experiments for Omega in FY23 [Slides]

Future HED & Nuclear Survivability platforms will use macroscopic 2PP lattice materials for inter-shell support and as a host for higher-yield DT wetted-lattice ablator targets. Average EOS and shock spatial non-uniformity measurements are needed as a function of lattice properties. The FY23 goal is to understand ablative & shock characteristics of heterogeneous D 2 - filled lattice materials at low drive intensities (~250TW/cm 2 ) in planar geometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser Ablation for Low-Cost Multijunction III-V Solar Cell Mesa Isolations

Eliminating photolithography from solar cell processing is a significant opportunity for cost reduction for III-V solar cells. In this work, we test femtosecond laser ablation and scribing as an alternative to contact photolithography and wet chemical etching for mesa isolation, when processing multijunction cells. We demonstrate that upright multijunction solar cells isolated by using the laser as a scribe to cleave through the substrate had virtually no performance loss when compared to a baseline cell processed with photolithography. By contrast, cells isolated by laser ablating through the active layers have performance losses that cannot be fully eliminated with post-processing etches. This demonstration of photolithography-free mesa isolation with no performance losses is promising for less expensive III-V manufacturing.

14 SOLAR ENERGY↗

Optical Microscopy-Guided Laser Ablation Electrospray Ionization Ion Mobility Mass Spectrometry: Ambient Single Cell Metabolomics with Increased Confidence in Molecular Identification

Single cell analysis is a field of increasing interest as new tools are continually being developed to understand intercellular differences within large cell populations. Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging technique for single cell metabolomics. Over the years, it has been validated that this ionization technique is advantageous for probing the molecular content of individual cells in situ. Here, we report the integration of a microscope into the optical train of the LAESI source to allow for visually informed ambient in situ single cell analysis. Additionally, we have coupled this ‘LAESI microscope’ to a drift-tube ion mobility mass spectrometer to enable separation of isobaric species and allow for the determination of ion collision cross sections in conjunction with accurate mass measurements. This combined information helps provide higher confidence for structural assignment of molecules ablated from single cells. Here, we show that this system enables the analysis of the metabolite content of Allium cepa epidermal cells with high confidence structural identification together with their spatial locations within a tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of the 176 Yb Interference Correction during Determination of the 176 Hf/ 177 Hf Ratio by Laser Ablation and Solution Analysis on the Neoma MC-ICP-MS

We utilized the Neoma™, a recently released MC-ICP-MS platform offered by ThermoFisher Scientific, to assess the behavior of the Lu-Yb-Hf system during laser ablation analyses of various zircon standards as well as solution-based analyses of the JMC-475 Hf standard doped with varying quantities of Yb and Lu. The primary goal of this work was to characterize the behavior of the Yb interference correction on the Neoma™ platform since this is one of the biggest issues in the Hf isotope analysis community and because the Neoma™ platform will supplant the Neptune™ series instrument. During laser ablation analysis, we found that the overall data quality scales proportionally with the total Hf signal intensity, with higher signal analyses producing extremely accurate (within 1 ε Hf unit) and precise (sub ε Hf unit within-run standard errors) data. At low Yb signals (<0.1 V 173 Yb), we were not able to produce an accurate internal Yb mass bias factor. However, utilizing an empirical approach allows for the application of session-specific relationships between the Yb and Hf mass bias factors, determined by analysis of standards of varying Yb content, to produce accurate ε Hf values from zircons with higher Yb/Hf ratios even where the total Hf signal intensity is relatively low. Similar behavior was observed in the solution analyses. Lastly, while the behavior of the Yb interference correction on the Neoma™ platform appears comparable to the Neptune™ series MC-ICP-MS, further work will help refine the understanding of the controls on mass bias behavior, oxide formation, session-to-session stability, etc.

36 MATERIALS SCIENCE↗

Ablation of ATJ Graphite at High Temperatures

Results of an extensive experimental program on the ablation of ATJ graphite in air at surface pressures of 0.3 to 4.4 atm and surface temperatures of 2570 to 4030 K are presented. The measured mass-loss rates are correlated with surface temperature, pressure, and effective nose radius. The results are compared with several equilibrium thermochemical ablation theories which differ basically in the chemical species that are considered and in the thermodynamic properties assigned to these species. All the theories predict about the same mass-loss rate in the diffusion-controlled oxidation regime and are in good agreement with the experimental results. At higher temperatures, however, the experimental and theoretical results do not agree. At temperatures above 3700 K, the experimental mass-loss rate becomes independent of pressure and an exponential function of temperature. A comparison of the high-temperature results with the theories indicates that all the theories, except the one based on the thermodynamic properties from the JANAF tables, are invalid because they overpredict the mass-loss rate. On the other hand, the theory based on the JANAF properties underpredicts the measured mass-loss rate by a factor of three at 4000 K. At least a portion of this difference between experiment and theory is attributed to particulate mass loss which is visually observed.

Thermochemical ablation↗

A New Ablative Heat Shield Sensor Suite Project

A new sensor suite is developed to measure performance of ablative thermal protection systems used in planetary entry vehicles for robotic and human exploration. The new sensor suite measures ablation of the thermal protection system under extreme heating encountered during planetary entry. The sensor technology is compatible with a variety of thermal protection materials, and is applicable over a wide range of entry conditions.

Thermal Protection↗

3D Multifunctional Ablative Thermal Protection System

NASA is developing the Orion spacecraft to carry astronauts farther into the solar system than ever before, with human exploration of Mars as its ultimate goal. One of the technologies required to enable this advanced, Apollo-shaped capsule is a 3-dimensional quartz fiber composite for the vehicle's compression pad. During its mission, the compression pad serves first as a structural component and later as an ablative heat shield, partially consumed on Earth re-entry. This presentation will summarize the development of a new 3D quartz cyanate ester composite material, 3-Dimensional Multifunctional Ablative Thermal Protection System (3D-MAT), designed to meet the mission requirements for the Orion compression pad. Manufacturing development, aerothermal (arc-jet) testing, structural performance, and the overall status of material development for the 2018 EM-1 flight test will be discussed.

Composite↗

Conformal Ablative Thermal Protection Systems (CA-TPS) for Venus and Saturn Backshells

This poster provides an overview of the work performed to date on the Conformal Ablative TPS (CA-TPS) element of the TPSM project out of GCDP. Under this element, NASA is developing improved ablative TPS materials based on flexible felt for reinforcement rather than rigid reinforcements. By replacing the reinforcements with felt, the resulting materials have much higher strain-to-failure and are much lower in thermal conductivity than their rigid counterparts. These characteristics should allow for larger tile sizes, direct bonding to aeroshells and even lower weight TPS. The conformal phenolic impregnated carbon felt (C-PICA) is a candidate for backshell TPS for both Venus and Saturn entry vehicles.

Saturn↗

Verification of a Finite Element Model for Pyrolyzing Ablative Materials

Ablating thermal protection system (TPS) materials have been used in many reentering spacecraft and in other applications such as rocket nozzle linings, fire protection materials, and as countermeasures for directed energy weapons. The introduction of the finite element model to the analysis of ablation has arguably resulted in improved computational capabilities due the flexibility and extended applicability of the method, especially to complex geometries. Commercial finite element codes often provide enhanced capability compared to custom, specially written programs based on versatility, usability, pre- and post-processing, grid generation, total life-cycle costs, and speed.

ablating materials↗

Ablative Thermal Protection Systems Fundamentals

This is a presentation of the fundamentals of ablative TPS materials for a short course at TFAWS 2017. It gives an overall description of what an ablator is, the equations that define it, and how to model it.

TPS↗

Analysis of Fibrous Felts for Flexible Ablators Using Synchrotron Hard X-Ray Micro-Tomography

We analyzed the material properties of low-density felts that are used as substrates for new-generation flexible and conformal carbon/phenolic ablators, and compared them with those of a rigid carbon fiber preform that is used to manufacture rigid carbon/phenolic ablators. Micro-tomography measurements were obtained using synchrotron X-rays, allowing the characterization of the materials microstructure at the scale of the fibers. Using the tomography voxels as computational grids, we computed tortuosity and room temperature conductivity. In addition we performed micro-scale simulations of the oxidation of carbon fibers using a random walk model for oxygen diffusion and a probability law to model surface reactions.

Ablation↗