Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Design of the Universal Neutron Irradiator

SHINE medical isotopes is developing a novel method to produce the medical isotope Mo-99, which is the parent of Tc-99m, the most widely used diagnostic compound in nuclear medicine. This method utilizes U-235 fission in a subcritical liquid target solution, driven by an accelerator-based neutron source that is based on a deuterium-tritium reaction in a gaseous target. In this approach, the neutron-generating target is surrounded by uranyl sulfate (low-enriched uranium); fission in the uranium salt solution efficiently produces the desired Mo-99, as well as other fission products. After irradiation, Mo-99 is separated and the uranyl sulfate solution can be irradiated again to produce Mo-99. This allows the solution to be recycled for a very long time and significantly reduces the amount of associated nuclear waste. SHINE has received U.S. Nuclear Regulatory Commission (NRC) approval to construct an Mo-99 production facility based on this method. In order to produce Mo-99 efficiently, the solution should be as close as possible to criticality. Because the solution is over moderated, any precipitation could push the solution to become critical and thereby hard to control. One of the possible precipitation scenarios is the formation of uranyl peroxide. Under irradiation, water decomposes into the products of radiolysis, some of which will form peroxide. To prevent precipitation, one has to develop a way to decompose the peroxide before it can react with uranium and form hard-to-dissolve precipitates. To study peroxide formation and develop methods to prevent precipitation, we are developing an experiment capable of mimicking radiation conditions in the SHINE system. This report describes the irradiation setup we designed to irradiate a small volume of uranyl sulfate solution for the duration of one SHINE irradiation (~6 days) at the relevant fission power (~0.5 W/cc)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The ASD Scorpius Accelerator at the NNSS. Recruitment Slides for the University of Nevada, Reno [Slides]

The Scorpius Accelerator: Supports the maintenance of the US nuclear stockpile, helps the US not return to nuclear testing, is one of four diagnostics being installed 963 feet below ground, probes subcritical implosions of nuclear material, and supports the validation of LANL and LLNL computer codes. We are searching engineers and scientists with experienced in: Mechanical Engineering, Electrical Engineering, Pulsed Power, Plasma Physics, Controls, Diagnostics, and Fluids and pressure systems.

42 ENGINEERING↗

FPGA-Based Spill Regulation System for the Muon Delivery Ring at Fermilab

The Muon to Electron Experiment (\acrshort{Mu2e}) requires a uniform beam profile from the Muon Delivery Ring to meet their experimental needs. A specialized Spill Regulation System (\acrshort{SRS}) has been developed to help achieve consistent spill uniformity. The system is based on a custom-designed carrier board featuring an Arria 10 SoC, capable of executing real-time feedback control. The FPGA processes beam pulses of approximately 200 ns every 1.695 microseconds, allowing for continuous monitoring of the extracted spill intensity through fast bunch integration. The system directly controls three quadrupole magnets, which work in conjunction with sextupole magnets to achieve third-order resonant extraction. Furthermore, the board interfaces with Fermilab s Accelerator Control Network (ACNET), enabling operators to modify spill regulation settings in real-time via the control network while providing diagnostic waveforms. These waveforms help operators monitor the process and fine-tune the feedback mechanisms. This paper presents an overview of the board's architecture and its initial progress toward regulating beam extraction. This initial version of the regulation system aims to evaluate baseline performance to inform future system improvements.

Berlioz, Jose Rene [Fermilab]↗

Hypervelocity impact facility for simulating materials exposure to impact by space debris

The Space Power Institute at Auburn University has constructed an electromagnetically driven particle accelerator for simulating the effects of space debris on the materials for use in advanced spacecraft. The facility consists of a capacitively driven accelerator section, a drift tube and a specimen impact chamber. The drift tube is sufficiently long that all electrical activity has ceased prior to impact in the specimen chamber. The impact chamber is large enough to allow a wide range of specimen geometries, ranging from small coupons to active portions of advanced spacecraft. The electric drive for the accelerator consists of a 67 kJ, 50 k capacitor bank arranged in a low inductance configuration. The bank is discharged through an aluminum armature/plastic ablator plate/projectile load in roughly 1.2 microsec. The evaporation of the ablaitor plate produces an expanding gas slug, mostly H2, traveling at a velocity of some 60 km/sec. Because of the pressure and local density, the expanding gas cloud accelerates projectiles due to plasma drag. To date, we have utilized projectiles consisting of 100 micron SiC, 100 and 400 micron Al2O3, 100 and 145 micron olivines. Since many particles are accelerated in a given experiment, there is a range of velocities for each shot as well as some particle breakup. Advanced diagnostics techniques allow determination of impact coordinates, velocity, and approximate size for as many as 50 individual impacts in a given experiment. We routinely measure velocities in the range 1-15 km/sec. We have used this facility to study a variety of impact generated phenomena on coated surfaces, both paint and plastic, thermal blanket material, solar cell arrays, and optical materials such as glass and quartz lenses. The operating characteristics of the gun, the advanced diagnostic scheme, and the results of studies of crater morphology are described in detail. Projectile residue analysis, as a function of impact velocity for the materials listed above, is also discussed. Wherever possible, these results are compared to those obtained by LDEF investigators and future experiments suggested which could help to explain unique features associated with LDEF impacts.

Rose, M. Frank↗

Adventures in Space Medicine

Human space flight experience has demonstrated a variety of hazards and risks to health and performance. In developing ways to help respond to these issues, the field of space medicine has developed a comprehensive program of space flight health risk management that has resulted in positive contributions to medicine and society in general. Examples include accelerated focus on critical health issues such as aging and osteoporosis, and development of new technologies such as non-invasive diagnostic testing for diabetics. The role of health care professionals in human space exploration represents a fulfillment of new adventures and expanding frontiers.

Billica, Roger D.↗

Performance characteristics of the deep space 1 flight spare ion thruster long duration test, the first 21,300 hours of operation

A long duration test of the DSl flight spare ion thruster (FT2) is presently being conducted at the Jet Propulsion Laboratory. To, date the thruster has accumulated over 23,500 hours of operation, and 190 kg of Xenon propellant, over 230% of the initial design life. The primary objectives of the test include the processing of 200 kg of Xenon propellant, the identification of unknown failure modes, the characterization and drivers of these failure modes, and to measure performance degradation as the thruster wears. The test is fitted with an extensive array of diagnostics to measure engine wear and performance degradation. To date the most notable erosion processes include severe discharge cathode keeper erosion, accelerator grid erosion, reduction in electrical isolation of the neutralizer assembly, and deposit formation within the neutralizer orifice, reducing margin from plume mode. Over the past 23,500 hours of operation, performance degradation has been minimal, and it is anticipated that the above erosion processes will not preclude the thruster from processing over 200 kg of Xenon.

ion thrusters deep space one↗

A Summary of the 2010 Photocathode Physics for Photoinjectors Workshop

This contribution contains a summary and some highlights from the Photocathode Physics for Photoinjectors (P3) Workshop [1]. This workshop, held at Brookhaven National Laboratory in Ocotber of 2010, was aimed at bringing the photocathode community together to discuss and explore the current state of the art in accelerator photocathodes, from both a theoretical and a materials science perspective. All types of photocathode materials were discussed, including metals, NEA and PEA semiconductors, and "designer" photocathodes with bespoke properties. Topics of the workshop included: Current status of photocathodes for accelerator applications Current fabrication methods Applications of modern materials science to the growth and analysis of cathodes Photoemission spectroscopy as a diagnostic of cathode performance Utilization of modern user facilities Photoemission theory Novel ideas in cathode development Discussion forum on future collaboration for cathode growth, analysis and testing

Bazarov, I↗

Minimizing Errant Beam at the Spallation Neutron Source

Over the years SNS has been optimizing the amount of errant beam pulses in the accelerator. The errant beam pulses can damage the superconducting cavities and thus lower the uptime of the accelerator. This talk will present the effort that has been made to lower the amount of errant beam pulses with new diagnostics, analysis of processes that cause errant beam, and the resulting lessons learned.

Peters, Charles C.↗

Mechanical Stability Study for Integrable Optics Test Accelerator at Fermilab

The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p⁺) diagnostic test ring. A heavy low frequency steel floor girder is proposed as the primary tier for IOTA device component support. Two design lengths; (8) 4 m and (2) 2.8 m long girders with identical cross section completely encompass the ring. This study focuses on the 4 m length girder and the development of a working prototype. Hydrostatic Level Sensor (HLS), temperature, metrology and fast motion measurements characterize the anticipated mechanical stability of the IOTA ring.

43 PARTICLE ACCELERATORS↗

High-efficiency high-energy Ka source for the critically-required maximum illumination of x-ray optics on Z using Z-petawatt-driven laser-breakout-afterburner accelerated ultrarelativistic electrons LDRD .

Under the auspices of the Science of Extreme Environments LDRD program, a <2 year theoretical- and computational-physics study was performed (LDRD Project 130805) by Guy R Bennett (formally in Center-01600) and Adam B. Sefkow (Center-01600): To investigate novel target designs by which a short-pulse, PW-class beam could create a brighter K{alpha} x-ray source than by simple, direct-laser-irradiation of a flat foil; Direct-Foil-Irradiation (DFI). The computational studies - which are still ongoing at this writing - were performed primarily on the RedStorm supercomputer at Sandia National Laboratories Albuquerque site. The motivation for a higher efficiency K{alpha} emitter was very clear: as the backlighter flux for any x-ray imaging technique on the Z accelerator increases, the signal-to-noise and signal-to-background ratios improve. This ultimately allows the imaging system to reach its full quantitative potential as a diagnostic. Depending on the particular application/experiment this would imply, for example, that the system would have reached its full design spatial resolution and thus the capability to see features that might otherwise be indiscernible with a traditional DFI-like x-ray source. This LDRD began FY09 and ended FY10.

43 PARTICLE ACCELERATORS↗

The role of the gas/plasma plume and self-focusing in a gas-filled capillary discharge waveguide for high-power laser-plasma applications

The role of the gas/plasma plume at the entrance of a gas-filled capillary discharge plasma waveguide in increasing the laser intensity has been investigated. Distinction is made between neutral gas and hot plasma plumes that, respectively, develop before and after discharge breakdown. Time-averaged measurements show that the on-axis plasma density of a fully expanded plasma plume over this region is similar to that inside the waveguide. Above the critical power, relativistic and ponderomotive self-focusing lead to an increase in the intensity, which can be nearly a factor of 2 compared with the case without a plume. When used as a laser plasma wakefield accelerator, the enhancement of intensity can lead to prompt electron injection very close to the entrance of the waveguide. Self-focusing occurs within two Rayleigh lengths of the waveguide entrance plane in the region, where the laser beam is converging. Analytical theory and numerical simulations show that, for a density of 3.0 × 10{sup 18} cm{sup −3}, the peak normalized laser vector potential, a{sub 0}, increases from 1.0 to 1.85 close to the entrance plane of the capillary compared with a{sub 0} = 1.41 when the plume is neglected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Applications of machine learning to a compact magnetic spectrometer for high repetition rate, laser-driven particle acceleration

Accurately and rapidly diagnosing laser–plasma interactions is often difficult due to the time-intensive nature of the analysis and will only become more so with the rise of high repetition rate lasers and the desire to implement feedback on a commensurate timescale. Diagnostic analysis employing machine learning techniques can help address this problem while maintaining a high degree of accuracy. We report on the application of machine learning to the analysis of a scintillator-based electron spectrometer for experiments on high intensity, laser–plasma interactions at the Colorado State University Advanced Lasers and Extreme Photonics facility. Our approach utilizes a neural network trained on synthetic data and tested on experiments to extract the accelerated electron temperature. By leveraging transfer learning, we demonstrate an improvement in the neural network accuracy, decreasing the network error by 50%.

Swanson, K. K. (ORCID:0000000286880568)↗

Toward Predicting Acute Myeloid Leukemia Patient Response to 7 + 3 Induction Chemotherapy via Diagnostic Microdosing

Acute myeloid leukemia (AML) is a rare yet deadly cancer of the blood and bone marrow. Presently, induction chemotherapy with the DNA damaging drugs cytarabine (ARA-C) and idarubicin (IDA), known as 7 + 3, is the standard of care for most AML patients. However, 7 + 3 is a relatively ineffective therapy, particularly in older patients, and has serious therapy-related toxicities. Therefore, a diagnostic test to predict which patients will respond to 7 + 3 is a critical unmet medical need. We hypothesize that a threshold level of therapy-induced 7 + 3 drug-DNA adducts determines cytotoxicity and clinical response. We further hypothesize that in vitro exposure of AML cells to nontoxic diagnostic microdoses enables prediction of the ability of AML cells to achieve that threshold during treatment. Our test involves dosing cells with very low levels of 14C-labeled drug followed by DNA isolation and quantification of drug-DNA adducts via accelerator mass spectrometry. Here, we have shown proof of principle by correlating ARA-C- and DOX-DNA adduct levels with cellular IC50 values of paired sensitive and resistant cancer cell lines and AML cell lines. Moreover, we have completed a pilot retrospective trial of diagnostic microdosing for 10 viably cryopreserved primary AML samples and observed higher ARA-C- and DOX-DNA adducts in the 7 + 3 responders than nonresponders. In conclusion, these initial results suggest that diagnostic microdosing may be a feasible and useful test for predicting patient response to 7 + 3 induction chemotherapy, leading to improved outcomes for AML patients and reduced treatment-related morbidity and mortality.

59 BASIC BIOLOGICAL SCIENCES↗

Beam Breakup Effects in Dielectric Based Accelerators

The dynamics of the beam in structure-based wakefield accelerators leads to beam stability issues not ordinarily found in other machines. In particular, the high current drive beam in an efficient wakefield accelerator loses a large fraction of its energy in the decelerator structure, resulting in physical emittance growth, increased energy spread, and the possibility of head-tail instability for an off axis beam, all of which can lead to severe reduction of beam intensity. Beam breakup (BBU) effects resulting from parasitic wakefields provide a potentially serious limitation to the performance of dielectric structure based wakefield accelerators as well. We report on experimental and numerical investigation of BBU and its mitigation. The experimental program focuses on BBU measurements at the AWA facility in a number of high gradient and high transformer ratio wakefield devices. New pickup-based beam diagnostics will provide methods for studying parasitic wakefields that are currently unavailable. The numerical part of this research is based on a particle-Green's function beam breakup code we are developing that allows rapid, efficient simulation of beam breakup effects in advanced linear accelerators. The goal of this work is to be able to compare the results of detailed experimental measurements with the accurate numerical results and to design an external FODO channel for the control of the beam in the presence of strong transverse wakefields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Global characterization of a laser-generated neutron source

Laser-driven neutron sources are routinely produced by the interaction of laser-accelerated protons with a converter. They present complementary characteristics to those of conventional accelerator-based neutron sources (e.g. short pulse durations, enabling novel applications like radiography). We present here results from an experiment aimed at performing a global characterization of the neutrons produced using the Titan laser at the Jupiter Laser Facility (Livermore, USA), where protons were accelerated from 23 $\mathrm {\mu }$ m thick plastic targets and directed onto a LiF converter to produce neutrons. For this purpose, several diagnostics were used to measure these neutron emissions, such as CR-39, activation foils, time-of-flight detectors and direct measurement of $^7{\rm Be}$ residual activity in the LiF converters. The use of these different, independently operating diagnostics enables comparison of the various measurements performed to provide a robust characterization. These measurements led to a neutron yield of $2.0\times 10^{9}$ neutrons per shot with a modest angular dependence, close to that simulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status and evolution of the ESRF beamline ID19

The ESRF synchrotron beamline ID19, dedicated to full-field parallel-beam imaging techniques such as phase-contrast and absorption microtomography and X-ray topography, is one of the most versatile instruments of its kind. This paper presents key characteristics of ID19 in its present form, names examples for research and development performed on the beamline, and outlines the plans for an upgrade on the beamline in coming years, to adapt to the growing needs of the user community. The technical goals envisioned include an increase in available beam size and maximum photon energy, and a substantial increase in flux density for applications using beams of small and intermediate size.

43 PARTICLE ACCELERATORS↗

Absolute calibration method for laser megajoule neutron yield measurement by activation diagnostics

The laser megajoule (LMJ) and the National Ignition Facility (NIF) plan to demonstrate thermonuclear ignition using inertial confinement fusion (ICF). The neutron yield is one of the most important parameters to characterize ICF experiment performance. For decades, the activation diagnostic was chosen as a reference at ICF facilities and is now planned to be the first nuclear diagnostic on LMJ, measuring both 2.45 MeV and 14.1 MeV neutron yields. Challenges for the activation diagnostic development are absolute calibration, accuracy, range requirement, and harsh environment. At this time, copper and zirconium material are identified for 14.1 MeV neutron yield measurement and indium material for 2.45 MeV neutrons. A series of calibrations were performed at Commissariat a l'Energie Atomique (CEA) on a Van de Graff facility to determine activation diagnostics efficiencies and to compare them with results from calculations. The CEA copper activation diagnostic was tested on the OMEGA facility during DT implosion. Experiments showed that CEA and Laboratory for Laser Energetics (LLE) diagnostics agree to better than 1% on the neutron yield measurement, with an independent calibration for each system. Also, experimental sensitivities are in good agreement with simulations and allow us to scale activation diagnostics for the LMJ measurement range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗