At least 847 records · Page 47

Calibration of the photon spectrometer PHOS of the ALICE experiment

The procedure for the energy calibration of the high granularity electromagnetic calorimeter PHOS of the ALICE experiment is presented. The methods used to perform the relative gain calibration, to evaluate the geometrical alignment and the corresponding correction of the absolute energy scale, to obtain the nonlinearity correction coefficients and finally, to calculate the time-dependent calibration corrections, are discussed and illustrated by the PHOS performance in proton-proton (pp) collisions at √s = 13 TeV. After applying all corrections, the achieved mass resolutions for π 0 and η mesons for p T > 1.7 GeV/c are σ m π0 = 4.56 ± 0.03 MeV/c 2 and σ m η = 15.3 ± 1.0 MeV/c 2 , respectively.

47 OTHER INSTRUMENTATION↗

Bright x-ray stainless steel K-shell source development at the National Ignition Facility

High x-ray conversion efficiency (XRCE) K-shell sources are being developed for high energy density experiments for use as backlighters and for the testing of materials exposed to high x-ray fluxes and fluences. Recently, sources with high XRCE in the K-shell x-ray energy range of iron and nickel were investigated at the National Ignition Facility (NIF). The x-ray conversion efficiency in the 5–9 keV spectral range was determined to be 6.8% ± 0.3%. These targets were 4.1 mm diameter, 4 mm tall hollow epoxy tubes having a 50 μm thick wall supporting a tube of 3 to 3.5 μm thick stainless steel. The NIF laser deposited ∼460 kJ of 3ω light into the target in a 140 TW, 3.3 ns square pulse. The absolute x-ray emission of the source was measured by two calibrated Dante x-ray spectrometers. Time resolved images filtered for the Fe K-shell were recorded to follow the heating of the target. Time integrated high-resolution spectra were recorded in the K-shell range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Thermal-Vacuum Compatible Flat Plate Radiometric Souce for System-Level Testing of Optical Sensors

This work describes the development of an improved vacuum compatible flat plate radiometric source used for characterizing and calibrating remote optical sensors, in situ, throughout their testing period. The original flat plate radiometric source was developed for use by the VIIRS instrument during the NPOESS Preparatory Project (NPP). Following this effort, the FPI has had significant upgrades in order to improve both the radiometric throughput and uniformity. Results of the VIIRS testing with the reconfigured FPI are reported and discussed.

Calibration↗

Future Flight Opportunities and Calibration Protocols for CERES: Continuation of Observations in Support of the Long-Term Earth Radiation Budget Climate Data Record

The goal of the Clouds and the Earth s Radiant Energy System (CERES) project is to provide a long-term record of radiation budget at the top-of-atmosphere (TOA), within the atmosphere, and at the surface with consistent cloud and aerosol properties at climate accuracy. CERES consists of an integrated instrument-algorithm validation science team that provides development of higher-level products (Levels 1-3) and investigations. It involves a high level of data fusion, merging inputs from 25 unique input data sources to produce 18 CERES data products. Over 90% of the CERES data product volume involves two or more instruments. Continuation of the Earth Radiation Budget (ERB) Climate Data Record (CDR) has been identified as critical in the 2007 NRC Decadal Survey, the Global Climate Observing System WCRP report, and in an assessment titled Impacts of NPOESS Nunn-McCurdy Certification on Joint NASA-NOAA Climate Goals . Five CERES instruments have flown on three different spacecraft: TRMM, EOS-Terra and EOS-Aqua. In response, NASA, NOAA and NPOESS have agreed to fly the existing CERES Flight Model (FM-5) on the NPP spacecraft in 2011 and to procure an additional CERES Sensor with modest upgrades for flight on the JPSS C1 spacecraft in 2014, followed by a CERES follow-on sensor for flight in 2018. CERES is a scanning broadband radiometer that measures filtered radiance in the SW (0.3-5 m), total (TOT) (0.3-200 m) and WN (8-12 m) regions. Pre-launch calibration is performed on each Flight Model to meet accuracy requirements of 1% for SW and 0.5% for outgoing LW observations. Ground to flight or in-flight changes are monitored using protocols employing onboard and vicarious calibration sources. Studies of flight data show that SW response can change dramatically due to optical contamination. with greatest impact in blue-to UV radiance, where tungsten lamps are largely devoid of output. While science goals remain unchanged for ERB Climate Data Record, it is now understood that achieving these goals is more difficult for two reasons. The first is an increased understanding of the dynamics of the Earth/atmosphere system which demonstrates that separation of natural variability from anthropogenic change on decadal time scales requires observations with higher accuracy and stabilit

Priestley, Kory J.↗

Modeling and Proof-of-Concept of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing collaboration searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a pilot experiment realization of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD coaxial reflector setup allows for the focusing of converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within $\SI{50}{\micro\metre}$ in the axial dimension. Additionally, it is demonstrated that the blackbody photon source used in this calibration must be at a temperature of at least $\SI{15}{\kelvin}$ to $\SI{40}{\kelvin}$, depending on the sensitivity of the SNSPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Closed Orbit Measurement System at the DELTA Synchrotron Radiation Facility And First Investigations Concerning the Installation of a Beam Based BPM Calibration System

For a synchrotron radiation source it is necessary to operate a monitoring system to determine the beam position with high resolution and accuracy with respect to the axis of the quadrupole magnets. In this paper the present closed orbit measurement system of the DELTA SR-Facility, concerning the hardware setup, data processing and the calibration methods, will be presented. The results of the calibration measurements and the recent operating experience will be discussed. These results show, that the system is close to the design resolution. But the BPM offsets with respect to the magnetic center of the quadrupole magnets turn out to be not acceptable. For some BPMs they are in the order of several 100 micro m. Therefore it was decided to install a beam based BPM calibration system in the near future . This system should allow to determine the BPM offsets relative to the center of the quadrupole magnets for all 40 BPMs. It is planned to install a system in order to change the focussing strength of each quadrupole individually either in a static or dynamic way.

43 PARTICLE ACCELERATORS↗

Feasibility of full-core pin resolved CFD simulations of small modular reactor with momentum sources

Complex flow structure interactions and heat transfer processes take place in nuclear reactor cores. Given the extreme pressure/temperature and radioactive conditions inside the core, numerical simulations offer an attractive and sometimes more feasible approach to study the related flow and heat transfer phenomena in addition to the experiments. Under the Exascale Computing Project, the full-core simulation of a small modular reactor (SMR) has been pursued coupling Computational Fluid Dynamics (CFD) and neutronics. A key aspect of the modeling of SMR fuel assemblies is the presence of spacer grids and the mixing promoted by mixing vanes or the equivalent. A reduced order methodology is adopted based on momentum sources to mimic the mixing of the vanes. The momentum sources have been carefully calibrated with detailed Large Eddy Simulations (LES) of spacer grids performed with Nek5000. Modeling the spacer grid and mixing vanes (SGMV) effect without body-fitted computational grid avoids the excessive costs in resolving the local geometric details, and thus supports the simulation to be scaled up to the full core. Besides the progress on momentum source modeling, this paper also features the first full-core pin resolved CFD simulation ever performed to the authors' knowledge. This represents a significant advancement in capability for the CFD of nuclear reactors, which will hopefully serve as an inspiration for further integrating high-fidelity numerical simulations in actual engineering designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pixel response characterization of the ARCADIA fully depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

Particle tracking detectors↗

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗

Control of Laser Plasma Based Accelerators up to 1 GeV

This dissertation documents the development of a broadband electron spectrometer (ESM) for GeV class Laser Wakefield Accelerators (LWFA), the production of high quality GeV electron beams (e-beams) for the first time in a LWFA by using a capillary discharge guide (CDG), and a statistical analysis of CDG-LWFAs. An ESM specialized for CDG-LWFAs with an unprecedented wide momentum acceptance, from 0.01 to 1.1 GeV in a single shot, has been developed. Simultaneous measurement of e-beam spectra and output laser properties as well as a large angular acceptance (> ± 10 mrad) were realized by employing a slitless scheme. A scintillating screen (LANEX Fast back, LANEX-FB)--camera system allowed faster than 1 Hz operation and evaluation of the spatial properties of e-beams. The design provided sufficient resolution for the whole range of the ESM (below 5% for beams with 2 mrad divergence). The calibration between light yield from LANEX-FB and total charge, and a study on the electron energy dependence (0.071 to 1.23 GeV) of LANEX-FB were performed at the Advanced light source (ALS), Lawrence Berkeley National Laboratory (LBNL). Using this calibration data, the developed ESM provided a charge measurement as well. The production of high quality electron beams up to 1 GeV from a centimeter-scale accelerator was demonstrated. The experiment used a 310 μm diameter gas-filled capillary discharge waveguide that channeled relativistically-intense laser pulses (42 TW, 4.5 x 10 18 W/cm 2 ) over 3.3 centimeters of sufficiently low density (≃ 4.3 x 10 18 /cm 3 ) plasma. Also demonstrated was stable self-injection and acceleration at a beam energy of ≃ 0.5 GeV by using a 225 μm diameter capillary. Relativistically-intense laser pulses (12 TW, 1.3 x 10 18 W/cm 2 ) were guided over 3.3 centimeters of low density (≃ 3.5 x 10 18 /cm 3 ) plasma in this experiment. A statistical analysis of the CDG-LWFAs performance was carried out. By taking advantage of the high repetition rate experimental system, several thousands of shots were taken in a broad range of the laser and plasma parameters. An analysis program was developed to sort and select the data by specified parameters, and then to evaluate performance statistically. The analysis suggested that the generation of GeV-level beams comes from a highly unstable and regime. By having the plasma density slightly above the threshold density for self injection, (1) the longest dephasing length possible was provided, which led to the generation of high energy e-beams, and (2) the number of electrons injected into the wakefield was kept small, which led to the generation of high quality (low energy spread) e-beams by minimizing the beam loading effect on the wake. The analysis of the stable half-GeV beam regime showed the requirements for stable self injection and acceleration. A small change of discharge delay t dsc , and input energy E in , significantly affected performance. The statistical analysis provided information for future optimization, and suggested possible schemes for improvement of the stability and higher quality beam generation. A CDG-LWFA is envisioned as a construction block for the next generation accelerator, enabling significant cost and size reductions.

43 PARTICLE ACCELERATORS↗

Summary of Alpha-Neutron Sources in GADRAS

A common source of neutrons for calibration and testing is alpha-neutron material, named for the alpha-neutron nuclear reaction that occurs within. This material contains a long-lived alpha-emitter and a lighter target element. When the alpha particle from the emitter is absorbed by the target, neutrons and gamma rays are released. Gamma Detector Response and Analysis Software (GADRAS) includes built-in alpha-neutron source definitions for AcC, AmB, AmBe, AmF, AmLi, CmC, and PuC. In addition, GADRAS users may create their own alpha-neutron sources by placing valid alpha-emitters and target elements in materials within their one-dimensional models (1DModel). GADRAS has the ability to use pre-built alpha-neutron sources for plotting or as trace-sources in 1D models. In addition, if any material (existing or user-defined) specified in a 1D model contains both an alpha emitter in conjunction with a target nuclide, or there is an interface between such materials, then the appropriate neutron-emission rate from the alpha-neutron reaction will be computed. The gamma-emissions from these sources are also computed, but are limited to a subset of nine target nuclides. If a user has experimental data to contribute to the alpha-neutron gamma emission database, it may be added directly or submitted to the GADRAS developers for inclusion. The gadras.exe.config file will be replaced when GADRAS updates are installed, so sending the information to the GADRAS developers is the preferred method for updating the database. This is also preferable because it enables other users to benefit from your efforts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Airborne Ground Penetrating Radar (GPR) for peat analyses in the Canadian Northern wetlands study

The study was conducted as part of the NASA Biospherics Research on Emissions from Wetlands (BREW) program. An important aspect of the program is to investigate the terrestrial production and atmospheric distribution of methane and other gases contributing to global warming. Multi-kilometer transects of airborne (helicopter) Ground Penetrating Radar (GPR) data were collected periodically along the 100 km distance from the coast inland so as to obtain a regional trend in peat depth and related parameters. Global Positioning System (GPS) data were simultaneously collected from the helicopter to properly georeference the GPR data. Additional 50 m ground-based transects of GPR data were also collected as a source of ground truthing, as a calibration aid for the airborne data sets, and as a source of higher resolution data for characterizing the strata within the peat. In situ peat depth probing and soil characterizations from excavated soil pits were used to verify GPR findings. Results from the ground-based data are presented.

Pelletier-Travis, Ramona E.↗

Calibrating Atmospheric Delay for the Cassini Gravitational Wave Experiment

The Cassini spacecraft together with one of the stations of the Deep Space Network (DSN) have been instrumented to carry out extremely precise Doppler tracking that will be used to search for the direct evidence of Gravitational radiation passing through our solar system. The two-way communications link between the ground antenna and the spacecraft constitute an "antenna" for gravitational waves that would perturb the phase of the RF signal in the link. The experiments will be carried out during the long cruise phase of the spacecraft on its journey to Saturn and will be sensitive to gravitational wave perturbations larger than the noise level fluctuations of 3 x 10(exp -15) as measured in the Allan Standard Deviation domain. The use of simultaneous, coherent X- and Ka-Band up and down signals will reduce the errors associated with charged particle fluctuations in the interplanetary medium and Earth's ionosphere to a negligible level. The primary fluctuations in the phase of the signals both to and from the spacecraft are expected to be caused by fluctuations in water vapor in the Earth's atmosphere We have designed and are testing a new atmospheric calibration system (with duplicate components) to sense line-of-sight water vapor and its physical temperature with a goal of calibrating 95% or more of tropospheric path delay fluctuations during the Cassini Gravitational Wave Experiment (GWE). The critical component of the calibration system consists of a newly designed water vapor radiometer having a I degree sensing beamwidth and 0.01 K brightness temperature stability over hour time scales. Auxiliary instrumentation includes a microwave temperature profiler to retrieve the vertical distribution of the vapor physical temperature, and surface meteorology. A detailed error budget has been developed to account for all of the possible sources of error during calibration of the GWE and will be discussed. Two identical calibration systems have been constructed in order to provide capability as well as backup during the actual GWE experiment. We will report on side-by-side testing of the vapor and temperature sensing components of this calibrations system as well as a comparison with a short baseline radio interferometric measurement at our Goldstone complex.

Resch, G. M.↗

Solar-Reflectance-Based Calibration of Spectral Radiometers

A method by which to calibrate a spectral radiometer using the sun as the illumination source is discussed. Solar-based calibrations eliminate several uncertainties associated with applying a lamp-based calibration to field measurements. The procedure requires only a calibrated reflectance panel, relatively low aerosol optical depth, and measurements of atmospheric transmittance. Further, a solar-reflectance-based calibration (SRBC), by eliminating the need for extraterrestrial irradiance spectra, reduces calibration uncertainty to approximately 2.2% across the solar-reflective spectrum, significantly reducing uncertainty in measurements used to deduce the optical properties of a system illuminated by the sun (e.g., sky radiance). The procedure is very suitable for on-site calibration of long-term field instruments, thereby reducing the logistics and costs associated with transporting a radiometer to a calibration facility.

Cattrall, Christopher↗

Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

strain-gage balance↗

JPSS-2 VIIRS Polarization Sensitivity Performance Comparison with Heritage VIIRS Sensors

The Joint Polar Satellite System 2 (JPSS-2) is the follow-on for the Suomi-National Polar-orbiting Partnership (S-NPP) and Joint Polar Satellite System 1 (JPSS-1) missions. These spacecrafts provide critical weather and global climate products to the user community. A primary sensor on both JPSS and S-NPP is the Visible-Infrared Imaging Radiometer Suite (VIIRS) with Earth observations covering the Reflective Solar Band (RSB), Thermal Emissive Band (TEB) and Day Night Band (DNB) spectral regions. The VIIRS Sensor Data Records (SDRs) contain the calibrated Earth observations that are used in Environmental Data Record (EDR) products such as Ocean Color/Chlorophyll (OCC) and Sea Surface Temperature (SST). This SDR calibration is performed using unpolarized sources such as the Solar Diffuser (SD) for the RSBs and an On-Board Calibrator BlackBody (OBCBB) for the TEBs. Therefore, polarized Earth scenes will have radiometric bias errors within the SDRs based on how sensitive VIIRS is to polarized illumination and is corrected in some EDR algorithms. This paper will discuss the JPSS-2 VIIRS polarization characterization methodology, polarization sensitivity results and compare its performance to its predecessors S-NPP and JPSS-1 VIIRS. Optical modifications to the JPSS-2 VIIRS sensor to address heritage polarization sensitivity issues will be discussed.

S-NPP↗

Jpss-4 VIIRS Polarization Sensitivity Performance Comparison With Heritage VIIRS Sensors

The Joint Polar Satellite System 4 (JPSS-4) is the follow-on for the Suomi-National Polar-orbiting Partnership (S-NPP) and Joint Polar Satellite Systems 1-3 (JPSS-1, -2 and -3) missions. A primary sensor on both JPSS and S-NPP spacecrafts is the Visible-Infrared Imaging Radiometer Suite (VIIRS) that provides valuable weather and climate products to the user community. VIIRS covers the Reflective Solar Band (RSB) and Thermal Emissive Band (TEB) spectral regions and contains a Day Night Band (DNB) that uses Lunar illumination at night. VIIRS provides top-of-atmosphere radiance, reflectance, and brightness temperature within the Sensor Data Records (SDRs) that are used in sea surface temperature, cloud characterization, land surface properties and ocean color/chlorophyll Environmental Data Record (EDR) products. The SDR calibration is performed using unpolarized sources such as a Solar Diffuser (SD) for the RSBs or an On-Board Calibrator BlackBody (OBCBB) for the TEBs. Earth scenes with polarizing properties will create radiometric bias errors within the SDRs based on how sensitive VIIRS is to polarized illumination and must be corrected in some EDR algorithms. This paper will discuss the JPSS-4 VIIRS polarization characterization methodology, polarization sensitivity results and compare its performance to its predecessors S-NPP and JPSS-1 through -3 VIIRS.

David Moyer↗