Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Aeroelastic considerations for continuous patrol/high altitude surveillance platforms

For the last several years, an investigation has been conducted regarding the feasibility of unmanned, airborne, High-Altitude Powered Platforms (HAPP), and High Surveillance Platforms for Over-the-Horizon Targeting (HI-SPOT). These airborne platforms have been proposed as a means of achieving a continuous regional communication-relay or for continuous regional surveillance for use in agricultural research or military applications, i.e., fleet support. These platforms would offer improvements over existing orbiting satellites. These improvements are related to better resolution and increased mission flexibility. The required mission endurance up to six months, would be obtained through the use of either solar power, a cryogenically fueled engine, or microwave-power. Attention is given to airborne platform configuration, structure, structural and aerodynamic modeling, modal analysis, and flutter analysis.

Turner, C. D.↗

Evaluation of the Separability of Monodisperse Polystyrene Latex Microspheres in a Continuous Flow Electrophoresis System

The continuous flow electrophoresis system makes electrophoresis possible in a free flowing film of aqueous electrolyte medium. The sample is introduced at one end of the chamber and is subjected to a lateral dc field. This process separates the sample into fractions since each component has a distinctive electrophoric mobility. Evaluations were made of sample conductivity and buffer conductivity as they affect sample band spread and separation using the Continuous Particle Electrophoresis (CPE) system. Samples were prepared from mixtures of 5 percent and 1 percent polystyrene latex (PSL) microspheres which were .4, .56 and .7 microns in diameter. These were prepared in electrolyte media 1x and 3x the conductivity of the curtain buffer, approximately 150 and 450 micro mhos/cm. Samples with matched conductivities produced greater resolution and less band spread than those with 3x the conductivity of the curtain buffer.

Williams, G., Jr.↗

A homotopy continuation method for general preliminary orbit determination and special application to the Tracking and Data Relay Satellite System

A recent mathematical technique for solving systems of equations is applied in a very general way to the orbit determination problem. The use of this technique, the homotopy continuation method, was motivated by the possible need to perform preliminary orbit determination in the Tracking and Data Relay Satellite System (TDRSS), using range and Doppler tracking alone. In the formulation studied here, a set of six tracking observations is continuously transformed from a set with known solutions to the given set with unknown solutions, and the corresponding orbit state vector is followed from the a priori orbit state to the solution orbit states. A modular numerical algorithm is developed to follow the state vector. The technique is formulated and then tested, using both real and simulated tracking, with positive results. Direct comparisons show that the basic method has a much larger radius of convergence than standard or simply modified Newton-Raphson methods. An extension of the basic method is formulated that is expected to produce a global method.

Smith, R. L.↗

Analysis of upper mantle structure using wave field continuation of P waves

Wave field continuation theory, which allows transformation of the seismic record section data directly into velocity-depth space, is tested for upper mantle analysis using a large array-recorded data set obtained at the 200-station Caltech-USGS Southern California Seismic Network that is representative of the structure beneath the gulf of California. The method's resolution capability is illustrated by the comparison of the slant stacks and downward continuation of both synthetic and data record sections. It is stressed that when high-quality, densely sampled digital data are available, the technique is easy to implement, provides an inversion which contains all the data in the global format, and produces an objective estimate of depth resolution as a function of ray parameter.

Walck, M. C.↗

Convolutional coding combined with continuous phase modulation

Background theory and specific coding designs for combined coding/modulation schemes utilizing convolutional codes and continuous-phase modulation (CPM) are presented. In this paper the case of r = 1/2 coding onto a 4-ary CPM is emphasized, with short-constraint length codes presented for continuous-phase FSK, double-raised-cosine, and triple-raised-cosine modulation. Coding buys several decibels of coding gain over the Gaussian channel, with an attendant increase of bandwidth. Performance comparisons in the power-bandwidth tradeoff with other approaches are made.

Pizzi, S. V.↗

Continuous Removal of Coal-Gasification Residue

Continuous-flow hopper processes solid residue from coal gasification, converting it from ashes, cinders, and clinkers to particles size of sand granules. Unit does not require repeated depressurization of lockhopper to admit and release materials. Therefore consumes less energy. Because unit has no airlock valves opened and closed repeatedly on hot, abrasive particles, subjected to lesser wear. Coal-gasification residue flows slowly through pressure-letdown device. Material enters and leaves continuously. Cleanout door on each pressure-letdown chamber allows access for maintenance and emergencies.

Collins, Earl R., Jr.↗

Continuous Fiberization of Silicon-Carbide-Nitride Precursor Resin

The objective of this project is to design and build a laboratory scale extruder and with it to fiberize 5000 continuous feet of silicon-carbide-nitride precursor resin. Subsequently the objective is extended to include the cross-linking and pyrolysis of approximately 100 feet of the resin fiber. The extruder is designed to accommodate approximately 1 cubic centimeter samples at accurately controllable rates corresponding to take-up from a single orifice of a 25 micron fiber at speeds in the 1000 feet/minute region. Positive feed delivery is achieved with a cylinder and piston driven by a geared down electric motor. Gear reduction is achieved primarily with off-the-shelf parts. Over 5000 feet of fiber, 20 to 30 micron diameter, are spun from precursor resin samples. The formation of continuous silicon carbide/silicon nitride fiber appears to be feasible.

Dunn, S. A.↗

Study of a homotopy continuation method for early orbit determination with the Tracking and Data Relay Satellite System (TDRSS)

A recent mathematical technique for solving systems of equations is applied in a very general way to the orbit determination problem. The study of this technique, the homotopy continuation method, was motivated by the possible need to perform early orbit determination with the Tracking and Data Relay Satellite System (TDRSS), using range and Doppler tracking alone. Basically, a set of six tracking observations is continuously transformed from a set with known solution to the given set of observations with unknown solutions, and the corresponding orbit state vector is followed from the a priori estimate to the solutions. A numerical algorithm for following the state vector is developed and described in detail. Numerical examples using both real and simulated TDRSS tracking are given. A prototype early orbit determination algorithm for possible use in TDRSS orbit operations was extensively tested, and the results are described. Preliminary studies of two extensions of the method are discussed: generalization to a least-squares formulation and generalization to an exhaustive global method.

Smith, R. L.↗

ERBS orbit ascent utilizing continuous low thrust maneuvers

The Earth Radiation Budget Satellite (ERBS) is a National Aeronautics and Space Administration (NASA) spacecraft whose purpose is to investigate the components of the earth's radiation budget. The ERBS was deployed in a 57 degree inclined, 352.2 kilometer altitude circular orbit by the NASA Space Transportation System (STS) on October 5, 1984. The spacecraft then ascended to its 603 kilometer, near-circular mission orbit by a series of continuous low-thrust maneuvers. The ERBS was the first free-flyer mission to rely on continuous low thrust to spiral from one circular orbit to another. Careful planning and monitoring of these maneuvers were essential to their successful execution. Errors in the prediction of the propulsion system performance or in burn duration would result in loss of contact with the spacecraft during a maneuver and could result in a premature end to the maneuver and difficulty in computing a definitive orbit.

Hoge, S. L.↗

Optimizing a continuously variable filter in a hybrid optical correlator

In contrast to binary filters, continuously variable optical filters offer an ability to conpensate for certain imperfections in the optics of a hybrid correlator. Arbitrary static phase errors are introduced into a model of a phase-only filtering hybrid correlator, and a method of discovering a correction for them simulated. By a recursive technique a first approximation to the impulse's matched filter is adjusted (allowed to relax) so as to produce successively more localized distribution of the output in the correlation plane. The method is motivated by the development of continuously-variable phase-only spatial light modulators, but it is applicable to amplitude modulators and -with appropriate modification -- to binary modulators as well. The technique is robust against the form of the system's departure from ideal behavior.

Juday, Richard D.↗

On Lipschitz continuity of nonlinear differential operators

In connection with approximations for nonlinear evolution equations, it is standard to assume that nonlinear terms are at least locally Lipschitz continuous. However, it is shown here that f = f(X,del sub u(X)) is Lipschitz continuous from the subspace W sup 1, infinity is a subset of L sub 2 into W sup 1,2, and maps W sup 2, infinity into W sup 1, infinity, if and only if f is affine with W sup 1, infinity coefficients. In fact, a local version of this claim is proved.

Keeling, Stephen L.↗

On high-continuity transfinite element formulations for linear-nonlinear transient thermal problems

This paper describes recent developments in the applicability of a hybrid transfinite element methodology with emphasis on high-continuity formulations for linear/nonlinear transient thermal problems. The proposed concepts furnish accurate temperature distributions and temperature gradients making use of a relatively smaller number of degrees of freedom; and the methodology is applicable to linear/nonlinear thermal problems. Characteristic features of the formulations are described in technical detail as the proposed hybrid approach combines the major advantages and modeling features of high-continuity thermal finite elements in conjunction with transform methods and classical Galerkin schemes. Several numerical test problems are evaluated and the results obtained validate the proposed concepts for linear/nonlinear thermal problems.

Tamma, Kumar K.↗

Continuous flow electrophoresis system experiments on shuttle flights STS-6 and STS-7

A space continuous flow electrophoresis system (CFES) was developed that would incorporate specific modifications to laboratory instruments to take advantage of weightlessness. The specific objectives were to use a model sample material at a high concentration to evaluate the continuous flow electrophoresis process in the CFES instrument and compare its separation resolution and sample throughput with related devices on Earth and to expand the basic knowledge of the limitations imposed by fluid flows and particle concentration effects on the electrophoresis process by careful design and evaluation of the space experiment. Hemoglobin and polysaccharide were selected as primary samples. The results from space show a large band spread of the high concentration of the single species of hemoglobin that was due to the mismatch of electrical conductivity between the sample and the buffer. On STS-7 the major objective was to evaluate the influence of the electrical properties of the sample constituents on the resolution of the CFES. As expected, the polystyrene latex microspheres dispersed in a solution with 3 times the electrical conductivity of the curtain buffer separated with a larger band spread than in the 2nd experiment.

Snyder, Robert S.↗

Moving wall, continuous flow electronphoresis apparatus

This invention relates generally to electrophoresis devices and more particularly to a moving wall, continuous flow device in which an electrophoresis chamber is angularly positionable with respect to the direction of moving belt walls. A frame with an electrophoresis chamber is rotatably supported between two synchronously driven belt walls. This allows the chamber to be angularly positionable with respect to the direction of belt travel, which compensates for electroosmotic flow within the electrophoresis chamber. Injection of a buffer solution via an opening and a homogenous sample stream via another opening is performed at the end of a chamber, and collection of buffer and the fractionated species particles is done by a conventional collection array at an opposite end of the chamber. Belts are driven at a rate which exactly matches the flow of buffer and sample through the chamber, which entrains the buffer to behave as a rigid electrophoretic medium, eliminating flow distortions (Poiseuille effect). Additionally, belt material for each belt is stored at one end of the device and is taken up by drive wheels at an opposite end. The novelty of this invention particularly lies in the electrophoresis chamber being angularly positionable between two moving belt walls in order to compensate for electroosmotic flow. Additionally, new belt material is continuously exposed within the chamber, minimizing flow distortion due to contamination of the belt material by the sample.

Rhodes, Percy H.↗

Continuous monitoring of blood volume changes in humans

Use of on-line high-precision mass densitometry for the continuous monitoring of blood volume changes in humans was demonstrated by recording short-term blood volume alterations produced by changes in body position. The mass density of antecubital venous blood was measured continuously for 80 min per session with 0.1 g/l precision at a flow rate of 1.5 ml/min. Additional discrete plasma density and hematocrit measurements gave linear relations between all possible combinations of blood density, plasma density, and hematocrit. Transient filtration phenomena were revealed that are not amenable to discontinuous measurements.

Hinghofer-Szalkay, H.↗

Fault diagnosis based on continuous simulation models

The results are described of an investigation of techniques for using continuous simulation models as basis for reasoning about physical systems, with emphasis on the diagnosis of system faults. It is assumed that a continuous simulation model of the properly operating system is available. Malfunctions are diagnosed by posing the question: how can we make the model behave like that. The adjustments that must be made to the model to produce the observed behavior usually provide definitive clues to the nature of the malfunction. A novel application of Dijkstra's weakest precondition predicate transformer is used to derive the preconditions for producing the required model behavior. To minimize the size of the search space, an envisionment generator based on interval mathematics was developed. In addition to its intended application, the ability to generate qualitative state spaces automatically from quantitative simulations proved to be a fruitful avenue of investigation in its own right. Implementations of the Dijkstra transform and the envisionment generator are reproduced in the Appendix.

Feyock, Stefan↗

Continuous flow electrophoresis system experiments on shuttle flights STS-6 and STS-7

The development of a space continuous flow electrophoresis system (CFES) is discussed. The objectives of the experiment were: (1) to use a model sample material at a high concentration to evaluate the continuous flow electrophoresis process in the McDonnell Douglass CFES instrument and compare its separation resolution and sample throughput with related devices on Earth, and (2) to expand the basic knowledge of the limitations imposed by fluid flows and particle concentration effects on the electrophoresis process by careful design and evaluation of the space experiment. Hemoglobin and polysaccharide were selected as samples of concentration effects. The results from space show a large band spread of the high concentration of the single species of hemoglobin that was principally due to the mismatch of electrical conductivity between the sample and buffer.

Snyder, Robert S.↗

Fast and stable recursive algorithms for continuous-time and discrete-time model conversions

Based on the Newton-Raphson method, this paper presents recursive algorithms that are rapidly convergent and more stable for modeling the equivalent continuous-time (discrete-time) model from the available discrete-time (continuous-time) model for a fixed sampling period. The newly developed recursive algorithms relax the constraints imposed upon the existing model conversion algorithms, and, thus, enhance the applications of microprocessors and associated microelectronics to digital control systems. A practical example is presented to demonstrate the effectiveness of the proposed procedures.

Shieh, L. S.↗