Search NASA⌕ Search

SEARCH · Search NASA

Results for “cost modules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost Efficient-by-Design Microreactors: Trade-offs between cost, technical, and regulatory factors

This research evaluates a cost reduction investigation through adoption of a functional containment approach on the microreactor system and structure. Trade-offs between microreactor system designs, fuels and reactor module sizes are evaluated based on performance-based and risk-informed design procedures. Cost savings are evaluated against trade-offs in the reliability of passive heat removal systems, reactivity control, and radioactive material containment. Results can inform the Microreactor Program and reactor designs on “sweet spots” for microreactors that are cost-efficient while meeting required safety limits.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thin-film module circuit design: Practical and reliability aspects

This paper will address several aspects of the design and construction of submodules based on thin film amorphous silicon (a-Si) p i n solar cells. Starting from presently attainable single cell characteristics, and a realistic set of specifications, practical module designs are discussed from the viewpoints of efficient designs, the fabrication requirements, and reliability concerns. The examples center mostly on series interconnected modules of the superstrate type with detailed discussions of each portion of the structure in relation to its influence on module efficiency. Emphasis is placed on engineering topics such as: area coverage, optimal geometries, and cost and reliability. Practical constraints on achieving optimal designs, along with some examples of potential pitfalls in the manufacture and subsequent performance of a-Si modules are discussed.

Daiello, R. V.↗

LCOE reduction through proactively optimized monitoring of PV Systems (Final Technical Report)

The project demonstrates the value proposition for a high-resolution monitoring system (HRMS) with diagnostic-prognostic capability and determine its impact on LCOE. The HRMS differs from conventional monitoring systems in a number of ways. First it will include the capability to automatically measure IV curves at the string and module levels. This provides a much richer view into the DC performance of the PV system and allows classification of many typical failure and degradation modes. Second, it will incorporate software capable of quantifying power and energy losses in the field as well as define the location and mechanism of the power and energy loss. Moreover, we aimed to deliver a prognostic system that is capable of predicting certain failures before they occur and giving system operators the opportunity to more efficiently plan operations and maintenance (O&M) activity in order to lower costs and increase yield over the life of the system. The research identifies cost targets required for different monitoring stages, including at the string combiner, at the individual string, and at the module level, to lower the levelized cost of energy (LCOE). Finally, a comprehensive guide determines the value PV monitoring brings to PV field operations. The guide assists plant operators in maximizing value from existing plants and identify the trade-offs of different monitoring solutions for future plants depending on the size, location, and expected system lifetime.

14 SOLAR ENERGY↗

Building Science Education for Solar Decathlon: Emissions and the Built Environment [Slides]

The Solar Decathlon Building Science Education series is designed to educate students and working professionals on building science principles that are paramount to the successful design of high-performance, energy-efficient buildings. Instructional content is presented in modules, covering specific topics. Altogether, this series aims to educate viewers on: 1) where/how energy is used in buildings; 2) how to define zero energy buildings; 3) how to apply the fundamentals of thermodynamics to building envelope design; 4) how to explain the science of how/why buildings use energy; 5) how to apply this knowledge to design comfortable energy efficient buildings. Students and working professionals can use this educational information at no cost to complement academic curriculum and continuing education activities. This is Module 7 which focuses on embodied environmental carbon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Space Station Furnace Facility. Volume 1: Requirements definition and conceptual design study, executive summary

The Space Station Freedom Furnace (SSFF) Study was awarded on June 2, 1989, to Teledyne Brown Engineering (TBE) to define an advanced facility for materials research in the microgravity environment of Space Station Freedom (SSF). The SSFF will be designed for research in the solidification of metals and alloys, the crystal growth of electronic and electro-optical materials, and research in glasses and ceramics. The SSFF is one of the first 'facility' class payloads planned by the Microgravity Science and Applications Division (MSAD) of the Office of Space Science and Applications of NASA Headquarters. This facility is planned for early deployment during man-tended operations of the SSF with continuing operations through the Permanently Manned Configuration (PMC). The SSFF will be built around a general 'Core' facility which provides common support functions not provided by SSF, common subsystems which are best centralized, and common subsystems which are best distributed with each experiment module. The intent of the facility approach is to reduce the overall cost associated with implementing and operating a variety of experiments. This is achieved by reducing the launch mass and simplifying the hardware development and qualification processes associated with each experiment. The Core will remain on orbit and will require only periodic maintenance and upgrading while new Furnace Modules, samples, and consumables are developed, qualified, and transported to the SSF. The SSFF Study was divided into two phases: phase 1, a definition study phase, and phase 2, a design and development phase. The definition phase 1 is addressed. Phase 1 was divided into two parts. In the first part, the basic part of the effort, covered the preliminary definition and assessment of requirements; conceptual design of the SSFF; fabrication of mockups; and the preparation for and support of the Conceptual Design Review (CoDR). The second part, the option part, covered requirements update and documentation; refinement of the selected conceptual design through additional trades and analyses; design, fabrication, and test of the Development Model; and design, fabrication, and test of the Interrack Demonstration Unit; and support of the requirements definition review (RDR). The purpose of part 2 was to prove concept feasibility.

Source record↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advances in Carbon Electrode Integration for Stable and Efficient Perovskite Solar Cells and Modules

Carbon-electrode-based perovskite solar cells (C-PSCs) have emerged as a cost-effective and scalable alternative to noble-metal-based PSCs, addressing critical challenges related to device stability, fabrication complexity, and commercialization potential. This review explores the recent progress in C-PSC development, focusing on the benefits of carbon electrodes (CEs), including their hydrophobicity, chemical inertness to halide corrosion, and compatibility with low-temperature cost-effective solution-based deposition methods. Despite relatively lower power conversion efficiencies (PCEs) than their metal (e.g., Au/Ag) counterparts, recent advances in carbon paste formulation, interfacial contact engineering, and work function modification have elevated C-PSC efficiencies above 22%. This review further examines strategies to enhance electrode conductivity, interfacial properties, and charge selectivity to further increase C-PSC performance. Progress in carbon-electrode-based perovskite solar modules (C-PSMs), particularly within mesoporous and planar architectures, is also analyzed, revealing significant developments in active area scaling and long-term stability. Notably, the limited research in inverted (PIN) C-PSCs is also highlighted as a compelling opportunity for innovation, given the architecture's inherent advantages in flexibility, tandem integration, and low-temperature processing. Collectively, these insights affirm the potential of C-PSCs and C-PSMs to deliver affordable, stable, and high-performance photovoltaics suitable for scalable deployment.

Carbon Electrodes↗

Integrated residential photovoltaic array development

Three basic module design concepts were analyzed with respect to both production and installation costs. The results of this evaluation were used to synthesize a fourth design which incorporates the best features of these initial concepts to produce a module/array design approach which offers the promise of a substantial reduction in the installed cost of a residential array. A unique waterproofing and mounting scheme was used to reduce the cost of installing an integral array while still maintaining a high probability that the installed array will be watertight for the design lifetime of the system. This recommended concept will also permit the array to be mounted as a direct or stand-off installation with no changes to the module design.

Shepard, N. F., Jr.↗

Long-term impact of light- and elevated temperature-induced degradation on photovoltaic arrays

Low levelized cost of electricity (LCOE) has been identified as critical for widespread adoption of photovoltaics (PV) without subsidies. Maintaining decades-long high-energy production is often an under-recognized opportunity in meeting cost goals because component lifetimes are not fully quantified at the time of manufacture. Whereas certain standardized tests minimize risk of early failure, there is little guidance to quantitatively predict degradation (or lack thereof) over decades, based on accelerated tests. In this article, we move toward bridging the understanding between indoor accelerated tests and outdoor performance data, with the goal of predicting energy yield with enough accuracy to inform financial decisions. Light- and elevated temperature-induced degradation (LETID) in p-type Si modules is analyzed in terms of impact on long-term module performance and thus LCOE. A method to predict the progression of LETID, using fixed kinetic constants and a numerical solution to the basic reaction rate equations, is detailed. Predictions are compared against both published data and that new to this study. These data include both indoor accelerated tests and fielded modules. We use the results in financial models to derive LCOE of modules in different climates with varying amounts of LETID, including uncertainty. Cost models based on the predictions indicate that LETID has a significant and climate-dependent impact on LCOE. Finally, we show that - even given the uncertainties identified in the study - these financial calculations can provide useful guidance to quantify risk based on accelerated test results. The analysis serves as an example of developing a predictive approach to PV reliability using physics of failure.

14 SOLAR ENERGY↗

Cost and Reliability Improvement for CIGS-Based PV on Flexible Substrate: May 24, 2006 -- July 31, 2010

Global Solar Energy rapidly advances the cost and performance of commercial thin-film CIGS products using roll-to-roll processing on steel foil substrate in compact, low cost deposition equipment, with in-situ sensors for real-time intelligent process control. Substantial increases in power module efficiency, which now exceed 13%, are evident at GSE factories in two countries with a combinedcapacity greater than 75 MW. During 2009 the average efficiency of cell strings (3780 cm2) was increased from 7% to over 11%, with champion results exceeding 13% Continued testing of module reliability in rigid product has reaffirmed extended life expectancy for standard glass product, and has qualified additional lower-cost methods and materials. Expected lifetime for PV in flexible packagescontinues to increase as failure mechanisms are elucidated, and resolved by better methods and materials. Cost reduction has been achieved through better materials utilization, enhanced vendor and material qualification and selection. The largest cost gains have come as a result of higher cell conversion efficiency and yields, higher processing rates, greater automation and improved control inall process steps. These improvements are integral to this thin film PV partnership program, and all realized with the 'Gen2' manufacturing plants, processes and equipment.

14 SOLAR ENERGY↗

Development of low cost custom hybrid microcircuit technology

Selected potentially low cost, alternate packaging and interconnection techniques were developed and implemented in the manufacture of specific NASA/MSFC hardware, and the actual cost savings achieved by their use. The hardware chosen as the test bed for this evaluation ws the hybrids and modules manufactured by Rockwell International fo the MSFC Flight Accelerometer Safety Cut-Off System (FASCOS). Three potentially low cost packaging and interconnection alternates were selected for evaluation. This study was performed in three phases: hardware fabrication and testing, cost comparison, and reliability evaluation.

Perkins, K. L.↗

Characterization of Highly Thermally Conductive Organic Substrates for a Double-Sided Cooled Power Module

Abstract Silicon-Carbide (SiC) power devices have become a promising option for traditional Silicon (Si) due to the superior material properties. To fully take advantage of the SiC devices, a high-performance power device packaging solution is necessary. This study proposes a cost-effective double-sided cooled (DSC) 1.2 kV SiC half-bridge power module using organic epoxy-resin composite dielectric (ERCD) substrates. The high mechanical and thermal performance of the power module is achieved by the low-modulus, moderate thermal conductivity, and relatively thin (120 μm) layer of ERCD material compared with traditional metal-clad ceramic approaches. This novel organic dielectric can withstand high voltage (5 kV @ 120 μm) and operate up to 250°C continuously, which is indispensable for high power applications. The thermal modeling results show that the equivalent thermal resistance junction-to-case (Rjc_eq) of the DSC power module using dual direct bonded copper (DBC) is 17% higher than the dual ERCD configuration. Furthermore, a non-insulated DSC power module concept is proposed for maximizing thermal performance by considering thermal vias in the ERCD substrate and direct-soldered heat sink. A thought process for optimization of thermal via design is demonstrated and it shows up to 24% of improvement on thermal performance compared with the insulated DSC power module.

Double-sided cooling, epoxy-resin composite dielec↗

Cost Comparison in 2015 Dollars for Radioisotope Power Systems -- Cassini and Mars Science Laboratory

Radioisotope power systems (RPSs) have enabled missions requiring reliable, long-lasting power in remote, harsh environments such as space since the early 1960s. Costs for RPSs are high, but are often misrepresented due to the complexity of space missions and inconsistent charging practices among the many and changing participant organizations over the years. This paper examines historical documentation associated with two past successful flight missions, each with a different RPS design, to provide a realistic cost basis for RPS production and deployment. The missions and their respective RPSs are Cassini, launched in 1997, that uses the general purpose heat source (GPHS) radioisotope thermoelectric generator (RTG), and Mars Science Laboratory (MSL), launched in 2011, that uses the multi-mission RTG (MMRTG). Actual costs in their respective years are discussed for each of the two RTG designs and the missions they enabled, and then present day values to 2015 are computed to compare the costs. Costs for this analysis were categorized into two areas: development of the specific RTG technology, and production and deployment of an RTG. This latter category includes material costs for the flight components (including Pu-238 and fine weave pierced fabric (FWPF)); manufacturing of flight components; assembly, testing, and transport of the flight RTG(s); ground operations involving the RTG(s) through launch; nuclear safety analyses for the launch and for the facilities housing the RTG(s) during all phases of ground operations; DOE’s support for NEPA analyses; and radiological contingency planning. This analysis results in a fairly similar 2015 normalized cost for the production and deployment of an RTG—approximately $118M for the GPHS-RTG and $109M for the MMRTG. In addition to these two successful flight missions, the costs for development of the MMRTG are included to serve as a future reference. Note that development costs included herein for the MMRTG do not include costs from NASA staff or facilities for their development efforts—they only include the amounts costed by DOE and DOE contractors. The 2015 value for MMRTG development is $83M. Both of the RPS types analyzed herein use the general purpose heat source (GPHS) module as the “heart of the RPS.” The estimates presented herein do not include development costs for the GPHS. These estimates also do not include the RPS infrastructure cost to maintain the facilities, equipment, and personnel necessary to enable the production of RPSs, except to the extent that the infrastructure is utilized during the production campaigns to provide RPSs for missions. It was not until after the Cassini mission that an RPS infrastructure funding structure was defined and funded separately from mission-specific elements. The information presented herein could allow for more accurate budget planning estimates for space missions being considered over the next decade and beyond.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluating the causes of photovoltaics cost reduction: Why is PV different?

The goals of this project were to quantify sources of cost reduction in photovoltaics (PV), improve theories of technological evolution, develop new analytical methods, and formu- late guidelines for continued cost reduction in photovoltaics. A number of explanations have been suggested for why photovoltaics have come down in cost rapidly over time, including increased production rates, significant R&D expenditures, heavy patenting ac- tivity, decreasing material and input costs, scale economies, reduced plant construction costs, and higher conversion efficiencies. We classified these proposed causes into low- level factors and high-level drivers. Low-level factors include technical characteristics, such as module efficiency or wafer area, which are easily posed in terms of variables of a cost equation. High-level factors include scale economies, research and development (R&D), and learning-by-doing.

14 SOLAR ENERGY↗

A Critical Review of the Circular Economy for Lithium-Ion Batteries and Photovoltaic Modules: Status, Challenges, and Opportunities

To meet net-zero emissions and cost targets for power production, recent analysis indicates that photovoltaic (PV) capacity in the United States could exceed 1 TW by 2050 alongside comparable levels of energy storage capacity, mostly from batteries. For comparison, the total U.S. utility-scale power capacity from all energy sources in 2020 was 1.2 TW (EIA 2022), of which solar satisfied approximately 3% (DOE 2021). With such massive scales of deployment, questions have arisen regarding issues of material supply for manufacturing, end-of-life management of technologies, environmental impacts across the life cycle, and economic costs to both individual consumers and society at large. A set of solutions to address these issues center on the development of a circular economy - shifting from a take-make-waste linear economic model to one that retains the value of materials and products as long as possible, recovering materials at end of life to recirculate back into the economy. With limited global experience, scholars and practitioners have begun to investigate circular economy pathways, focusing on applying novel technologies and analytical methods to fast-growing sectors like renewable energy. This critical review aims to synthesize the growing literature to identify key insights, gaps, and opportunities for research and implementation of a circular economy for two of the leading technologies that enable the transition to a renewable energy economy: solar PV and lithium-ion batteries (LIBs). We apply state-of-the-science systematic literature review procedures to critically analyze over 3,000 publications on the circular economy of solar PV and LIBs, categorizing those that pass a series of objective screens in ways that can illuminate the current state of the art, highlight existing impediments to a circular economy, and recommend future technological and analytical research. We conclude that while neither PV nor LIB industries have reached a circular economy, they are both on a path towards increased circularity. Based on our assessment of the state of current literature and scientific understanding, we recommend research move beyond its prior emphasis on recycling technology development to more comprehensively investigate other CE strategies, more holistically consider economic, environmental and policy aspects of CE strategies, increase leveraging of digital information systems that can support acceleration towards a CE, and to continue to study CE-related aspects of LIB and PV markets.

circular economy↗

Cassegrainian concentrator solar array exploratory development module

A miniaturized Cassegrainian concentrator solar array concept is under development to reduce the cost of multi-kW spacecraft solar arrays. A primary parabolic reflector directs incoming solar energy to a secondary, centrally mounted inverted hyperbolic reflector and down onto a solar cell mounted on an Mo heat spreader on a 0.25 mm thick Al heat fin. Each unit is 12.7 mm thick, which makes the concentrator assembly roughly as thick as a conventional panel. The output is 100 W/sq and 20 W/kg, considering 20% efficient Si cells at 100 suns. A tertiary light catcher is mounted around the cell to ameliorate optic errors. The primary reflector is electroformed Ni with protective and reflective coatings. The cells have back surface reflectors and a SiO antireflective coating. An optical efficiency of 80% is projected, and GaAs cells are being considered in an attempt to raise cell efficiencies to over 30%.

Patterson, R. E.↗

Reduction of Glass Surface Reflectance by Ion Beam Surface Modification

This is the final report for DOE contract DE-EE0000590. The purpose of this work was to determine the feasibility of the reduction of the reflection from the front of solar photovoltaic modules. Reflection accounts for a power loss of approximately 4%. A solar module having an area of one square meter with an energy conversion efficiency of 18% generates approximately 180 watts. If reflection loss can be eliminated, the power output can be increased to 187 watts. Since conventional thin-film anti-reflection coatings do not have sufficient environmental stability, we investigated the feasibility of ion beam modification of the glass surface to obtain reduction of reflectance. Our findings are generally applicable to all solar modules that use glass encapsulation, as well as commercial float glass used in windows and other applications. Ion implantation of argon, fluorine, and xenon into commercial low-iron soda lime float glass, standard float glass, and borosilicate glass was studied by implantation, annealing, and measurement of reflectance. The three ions all affected reflectance. The most significant change was obtained by argon implantation into both low-iron and standard soda-lime glass. In this way samples were formed with reflectance lower than can be obtained with a single-layer coatings of magnesium fluoride. Integrated reflectance was reduced from 4% to 1% in low-iron soda lime glass typical of the glass used in solar modules. The reduction of reflectance of borosilicate glass was not as large; however borosilicate glass is not typically used in flat plate solar modules. Unlike conventional semiconductor ion implantation doping, glass reflectance reduction was found to be tolerant to large variations in implant dose, meaning that the process does not require high dopant uniformity. Additionally, glass implantation does not require mass analysis. Simple, high current ion implantation equipment can be developed for this process; however, before the process can be employed on full scale solar modules, equipment must be developed for ion implanting large sheets of glass. A cost analysis shows that the process can be economical. Our finding is that the reduction of reflectance by ion beam surface modification is technically and economically feasible. The public will benefit directly from this work by the improvement of photovoltaic module efficiency, and indirectly by the greater understanding of the modification of glass surfaces by ion beams.

14 SOLAR ENERGY↗