Search NASA⌕ Search

SEARCH · Search NASA

Results for “damage threshold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Stone-Wales Defects Created by Low Energy Recoils in Single-walled Silicon Carbide Nanotubes

The defect creation at low energy events was studied using density functional theory molecular dynamics simulations in silicon carbide nanotubes, and the displacement threshold energies determined exhibit a dependence on sizes, which decrease with decreasing diameter of the nanotubes. The Stone-Wales (SW) defect, which is a common defect configurations induced through irradiation in nanotubes, has also been investigated, and the formation energies of the SW defects increase with increasing diameter of the nanotubes. The mean threshold energies were found to be 23 and 18 eV for Si and C in armchair (5,5) nanotubes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recovery of damage in rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays

This paper reports on the recovery properties of rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays. The results indicated that complex recovery properties controlled the damage sensitivities of the tested parts. The results also indicated that damage sensitivities depended on dose rate, total dose, supply bias, gate bias, transistor type, radiation source, and particle energy. The complex nature of these dependencies make interpretation of LSI device performance in space (exposure to entire electron and proton spectra) difficult, if not impossible, without respective ground tests and analyses. Complete recovery of n-channel shifts was observed, in some cases within hours after irradiation, with equilibrium values of threshold voltages greater than their pre-irradiation values. This effect depended on total dose, radiation source, and gate bias during exposure. In contrast, the p-channel shifts recovered only 20 percent within 30 days after irradiation.

Brucker, G. J.↗

Impact of Fraction Size on Lung Radiation Toxicity: Hypofractionation may be Beneficial in Dose Escalation of Radiotherapy for Lung Cancers

Purpose: To assess how fraction size impacts lung radiation toxicity and therapeutic ratio in treatment of lung cancers. Methods and Materials: The relative damaged volume (RDV) of lung was used as the endpoint in the comparison of various fractionation schemes with the same normalized total dose (NTD) to the tumor. The RDV was computed from the biologically corrected lung dose-volume histogram (DVH), with an alpha/beta ratio of 3 and 10 for lung and tumor, respectively. Two different (linear and S-shaped) local dose-effect models that incorporated the concept of a threshold dose effect with a single parameter D{sub L50} (dose at 50% local dose effect) were used to convert the DVH into the RDV. The comparison was conducted using four representative DVHs at different NTD and D{sub L50} values. Results: The RDV decreased with increasing dose/fraction when the NTD was larger than a critical dose (D{sub CR}) and increased when the NTD was less than D{sub CR}. The D{sub CR} was 32-50 Gy and 58-87 Gy for a small tumor (11 cm{sup 3}) for the linear and S-shaped local dose-effect models, respectively, when D{sub L50} was 20-30 Gy. The D{sub CR} was 66-97 Gy and 66-99 Gy, respectively, for a large tumor (266 cm{sup 3}). Hypofractionation was preferred for small tumors and higher NTDs, and conventional fractionation was better for large tumors and lower NTDs. Hypofractionation might be beneficial for intermediate-sized tumors when NTD = 80-90 Gy, especially if the D{sub L50} is small (20 Gy). Conclusion: This computational study demonstrated that hypofractionated stereotactic body radiotherapy is a better regimen than conventional fractionation in lung cancer patients with small tumors and high doses, because it generates lower RDV when the tumor NTD is kept unchanged.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature and load-ratio dependent fatigue-crack growth in the CrMnFeCoNi high-entropy alloy

Multiple-principal element alloys known as high-entropy alloys have significantly been gaining attention for the vast variety of compositions and potential combinations of properties that remain to be explored. Of these alloys, one of the earliest, the ‘Cantor alloy’ CrMnFeCoNi, demonstrates excellent damage-tolerance with tensile strengths of ~1 GPa and fracture toughness values in excess of 200 MPa√m; moreover, these mechanical properties tend to further improve at cryogenic temperatures. Yet, few studies have explored its corresponding fatigue properties. Here we expand on our previous study to examine the mechanics and mechanisms of fatigue-crack propagation in the CrMnFeCoNi alloy (~7 μm grain size), with emphasis on long-life, near-threshold fatigue behavior, specifically as a function of load ratio at temperatures between ambient and liquid-nitrogen temperatures (293 K–77 K). We discover that Δ K th fatigue thresholds are decreased with increasing positive load ratios, $\mathcal{R}$ between 0.1 and 0.7, but are increased at decreasing temperature. These effects can be attributed to the role of roughness-induced crack closure, which was estimated using compliance measurements. Evidence of deformation twinning at the crack tip during fatigue-crack advance was not apparent at ambient temperatures but seen at higher stress intensities (Δ K ~ 20 MPa√m) at 77 K by post mortem microstructural analysis for tests at $\mathcal{R}$ = 0.1 and particularly at 0.7. Overall, the fatigue behavior of this alloy was found to be superior, or at least comparable, to conventional cryogenic and TWIP steels such as 304 L or 316 L steels and Fe-Mn steels; these results coupled with the remarkable strength and fracture toughness of the Cantor alloy at low temperatures indicate significant promise for the utility of this material for applications at cryogenic environments.

36 MATERIALS SCIENCE↗

Evidence Report: Risk of Cardiovascular Disease and Other Degenerative Tissue Effects from Radiation Exposure

Occupational radiation exposure from the space environment may result in non-cancer or non-CNS degenerative tissue diseases, such as cardiovascular disease, cataracts, and respiratory or digestive diseases. However, the magnitude of influence and mechanisms of action of radiation leading to these diseases are not well characterized. Radiation and synergistic effects of radiation cause DNA damage, persistent oxidative stress, chronic inflammation, and accelerated tissue aging and degeneration, which may lead to acute or chronic disease of susceptible organ tissues. In particular, cardiovascular pathologies such as atherosclerosis are of major concern following gamma-ray exposure. This provides evidence for possible degenerative tissue effects following exposures to ionizing radiation in the form of the GCR or SPEs expected during long-duration spaceflight. However, the existence of low dose thresholds and dose-rate and radiation quality effects, as well as mechanisms and major risk pathways, are not well-characterized. Degenerative disease risks are difficult to assess because multiple factors, including radiation, are believed to play a role in the etiology of the diseases. As additional evidence is pointing to lower, space-relevant thresholds for these degenerative effects, particularly for cardiovascular disease, additional research with cell and animal studies is required to quantify the magnitude of this risk, understand mechanisms, and determine if additional protection strategies are required.The NASA PEL (Permissive Exposure Limit)s for cataract and cardiovascular risks are based on existing human epidemiology data. Although animal and clinical astronaut data show a significant increase in cataracts following exposure and a reassessment of atomic bomb (A-bomb) data suggests an increase in cardiovascular disease from radiation exposure, additional research is required to fully understand and quantify these adverse outcomes at lower doses (less than 0.5 gray (SI unit for ionizing radiation dosage, i.e. one joule of radiation energy per one kilogram of matter)) to facilitate risk prediction. This risk has considerable uncertainty associated with it, and no acceptable model for projecting degenerative tissue risk is currently available. In particular, risk factors such as obesity, alcohol, and tobacco use can act as confounding factors that contribute to the large uncertainties. The PELs could be violated under certain scenarios, including following a large SPE (solar proton event) or long-term GCR (galactic cosmic ray) exposure. Specifically, for a Mars mission, the accumulated dose is sufficiently high that epidemiology data and preliminary risk estimates suggest a significant risk for cardiovascular disease. Ongoing research in this area is intended to provide the evidence base for accurate risk quantification to determine criticality for extended duration missions. Data specific to the space radiation environment must be compiled to quantify the magnitude of this risk to decrease the uncertainty in current PELs and to determine if additional protection strategies are required. New research results could lead to estimates of cumulative radiation risk from CNS and degenerative tissue diseases that, when combined with the cancer risk, may have major negative impacts on mission design, costs, schedule, and crew selection. The current report amends an earlier report (Human Research Program Requirements Document, HRP-47052, Rev. C, dated Jan 2009) in order to provide an update of evidence since 2009.

Patel, Zarana↗

An all-electronic fail-safe for stimulated Brillouin scattering suppression

The mitigation of transverse stimulated Brillouin scattering (SBS) via phase modulation is mandatory to avoid damage in high-energy laser systems. A novel fail-safe system that indirectly monitors the optical bandwidth applied to suppress SBS by monitoring the input, reflected, and through rf power of the SBS-suppression lithium-niobate phase modulator is demonstrated. The fail-safe system has high sensitivity and reliability provided by optimized redundant circuits for power monitoring and fail-safe decision logic. Calibration of the fail-safe’s thresholds is straightforward. Furthermore, the fail-safe circuitry reacts within 45 ns to stop an incorrectly modulated pulse by blocking the propagation of an electronic timing trigger.

fail-safe↗

Effects of Desiccation and Freezing on Microbial Ionizing Radiation Survivability: Considerations for Mars Sample Return

Increasingly, national space agencies are expanding their goals to include Mars exploration with sample return. To better protect Earth and its biosphere from potential extraterrestrial sources of contamination, as set forth in the Outer Space Treaty of 1967, international efforts to develop planetary protection measures strive to understand the danger of cross-contamination processes in Mars sample return missions. We aim to better understand the impact of the martian surface on microbial dormancy and survivability. Radiation resistance of microbes is a key parameter in considering survivability of microbes over geologic times on the frigid, arid surface of Mars that is bombarded by solar and galactic cosmic radiation. We tested the influence of desiccation and freezing on the ionizing radiation survival of six model microorganisms: vegetative cells of two bacteria (Deinococcus radiodurans, Escherichia coli) and a strain of budding yeast (Saccharomyces cerevisiae); and vegetative cells and endospores of three Bacillus bacteria (B. subtilis, B. megaterium, B. thuringiensis). Desiccation and freezing greatly increased radiation survival of vegetative polyploid microorganisms when applied separately, and when combined, desiccation and freezing increased radiation survival even more so. Thus, the radiation survival threshold of polyploid D. radiodurans cells can be extended from the already high value of 25 kGy in liquid culture to an astonishing 140 kGy when the cells are both desiccated and frozen. However, such synergistic radioprotective effects of desiccation and freezing were not observed in monogenomic or digenomic Bacillus cells and endospores, which are generally sterilized by 12 kGy. This difference is associated with a critical requirement for survivability under radiation, that is, repair of genome damage caused by radiation. Deinococcus radiodurans and S. cerevisiae accumulate similarly high levels of the Mn antioxidants that are required for extreme radiation resistance, as do endospores, though they greatly exceed spores in radioresistance because they contain multiple identical genome copies, which in D. radiodurans are joined by persistent Holliday junctions. We estimate ionizing radiation survival limits of polyploid DNA-based life-forms to be hundreds of millions of years of background radiation while buried in the martian subsurface. Our findings imply that forward contamination of Mars will essentially be permanent, and backward contamination is a possibility if life ever existed on Mars.

59 BASIC BIOLOGICAL SCIENCES↗

Low-velocity impact tests on fibrous composite sandwich structures

The effect of low-velocity projectile impact on the load-carrying ability of the composite sandwich structural components is investigated experimentally, the impact simulating the damage caused by runway debris and the accidental dropping of hand tools during servicing on secondary aircraft structures made with composites. The sandwich-type beam specimens were fabricated with graphite/epoxy face sheets, aluminum honeycomb core, and a steel (back) plate. A four-point beam-loading apparatus was used, and the ultimate strength, ultimate strain, and residual strength of the composites were determined. A faired curve is presented indicating the lower bound of the failure threshold for each of the laminate configurations tested in compression and tension as a function of the projectile impact energy. It is shown that strength degradation due to impact is dependent on the laminate configuration and the fiber/matrix combination. The laminates having more angle plies near the impact surface and unidirectional plies elsewhere seem to show extensive interply and intraply fiber delaminations at failure relative to the laminates with a cross-ply on the impact surface.

Sharma, A. V.↗

Ageing airplane repair assessment program for Airbus A300

Summary as a result of a commitment between the FAA and ATA the Airworthiness Assurance Task Force (AATF) steering committee requested the transport aircraft manufacturers to develop a program to assess the repairs on in-service aircraft since recent Supplemental Structural Inspection Programs (SSIP) had not been addressed to assessing repairs. The intent of the assessment program is to remove all existing ambiguities and to achieve a sufficient level of safety across the fleet by applying actual fatigue and damage tolerance criteria defined by FAR 25.571 to repaired structures. A general three stage program has been developed with major aircraft manufacturers and airlines cooperation including area/component classification, repair categorization and inspection/removal requirement establishment which is the basis for model specific repair assessment programs. This paper describes the current status of the repair categorization activities and includes all details about the methodologies developed for determination of the inspection program for the skin on pressurized fuselages. For inspection threshold determination two methods are defined based on fatigue life approach, i.e. a simplified and a detailed method. The detailed method considers 15 different parameters to assess the influences of material, geometry, size, location, aircraft usage and workmanship on the fatigue life of the repair and the original structure. For definition of the inspection intervals a general method is developed which applies to all concerned repairs. For this the initial flaw concept is used by considering 6 parameters and the detectable flaw sizes depending on proposed nondestructive inspection methods. An alternative method is provided for small repairs allowing visual inspection with shorter intervals.

Aging Aircraft↗

A Multi-sensor Evaluation of Precipitation Uncertainty for Landslide-triggering Storm Events

Extreme precipitation can have profound consequences for communities, resulting in natural hazards such as rainfall-triggered landslides that cause casualties and extensive property damage. A key challenge to understanding and predicting rainfall triggered landslides comes from observational uncertainties in the depth and intensity of precipitation preceding the event. Practitioners and researchers must select among a wide range of precipitation products, often with little guidance. Here we evaluate the degree of precipitation uncertainty across multiple precipitation products for a large set of landslide triggering storm events and investigate the impact of these uncertainties on predicted landslide probability using published intensity-duration thresholds. The average intensity, peak intensity, duration, and NOAA-Atlas return periods are compared ahead of reported landslides across the continental US and Canada. Precipitation data are taken from four products that cover disparate measurement methods: near real-time and post-processed satellite (IMERG), radar (MRMS), and gauge-based (NLDAS-2). Landslide-triggering precipitation was found to vary widely across precipitation products with the depth of individual storm events diverging by as much as 296mm with an average range of 51mm. Peak intensity measurements, which are typically influential in triggering landslides, were also highly variable with an average range of 7.8262745mm/hr and as much as 57mm/hr. The two products more reliant upon ground-based observations (MRMS and NLDAS-2) performed better at identifying landslides according to published intensity duration storm thresholds, but all products exhibited hit-ratios of greater than 0.56. A greater proportion of landslides were predicted when including only manually-verified landslide locations. We recommend practitioners consider low-latency products like MRMS for investigating landslides, given their near-real time data availability and good performance in detecting landslides. Practitioners would be well-served considering more than one product as a way to confirm intense storm signals and minimize the influence of noise and false alarms.

Precipitation inter-comparison↗

SIMULATION OF NEUTRON BACKGROUNDS FROM THE ILC EXTRACTION LINE BEAM DUMP

The operation of the International Linear Collider (ILC) as a precision measurement machine is dependent upon the quality of the charge-coupled device (CCD) silicon vertex detector. An integrated fl ux of 1010 neutrons/cm2 incident upon the vertex detector will degrade its performance by causing displacement damage in the silicon. One source of the neutron background arises from the dumping of the spent electron and positron beams into the extraction line beam dumps. The Monte Carlo program FLUKA was used to simulate the collision of the electron beam with the dump and to determine the resulting neutron fl ux at the interaction point (IP). A collimator and tunnel were added and their effect on the fl ux was analyzed. A neutron source was then generated and directed along the extraction line towards a model of the vertex detector to determine the neutron fl ux in its silicon layers. Models of the beampipe and BeamCal, a silicon-tungsten electromagnetic calorimeter in the very forward region of the detector, were placed in the extraction line and their effects on scattering were studied. The IP fl uence was determined to be 3.7x1010 +/- 2.3x1010 neutrons/cm2/year when the tunnel and collimator were in place, with no appreciable increase in statistics when the tunnel was removed. The BeamCal was discovered to act as a collimator by signifi cantly impeding the fl ow of neutrons towards the detector. The majority of damage done to the fi rst layer of the detector was found to come from neutrons with a direct line of sight from the fi rst extraction line quadrupole QDEX1, with only a small fraction scattering off of the beampipe and into the detector. The 1 MeV equivalent neutron fl uence was determined to be 9.3x108 neutrons/cm2/year from the electron beam alone. The two beams collectively contribute double to this fl uence, which is 19% of the threshold value in one year. Future work will improve the detector model and other sources of neutron backgrounds will be analyzed.

Darbha, S↗

Effects of temperature and particle size on deposition in land based turbines - article no. 051503

Four series of tests were performed in an accelerated deposition test facility to study the independent effects of particle size, gas temperature, and metal temperature on ash deposits from two candidate power turbine synfuels (coal and petcoke). The facility matches the gas temperature and velocity of modern first stage high pressure turbine vanes while accelerating the deposition process. Particle size was found to have a significant effect on capture efficiency with larger particles causing significant thermal barrier coating (TBC) spallation during a 4 h accelerated test. In the second series of tests, particle deposition rate was found to decrease with decreasing gas temperature. The threshold gas temperature for deposition was approximately 960{sup o}C. In the third and fourth test series, impingement cooling was applied to the back side of the target coupon to simulate internal vane cooling. Capture efficiency was reduced with increasing mass flow of coolant air; however, at low levels of cooling, the deposits attached more tenaciously to the TBC layer. Postexposure analyses of the third test series (scanning electron microscopy and X-ray spectroscopy) show decreasing TBC damage with increased cooling levels.

20 FOSSIL-FUELED POWER PLANTS↗

Impact of shading following installation of agrivoltaic systems on eco-physiological and biochemical attributes of “Howes” cranberry in Massachusetts

Agrivoltaic (AV) systems, which integrate solar energy generation with crop production on the same piece of land, offer a sustainable solution for optimizing land-use efficiency. However, the impact of shading induced by solar panels on crop growth, physiology, and metabolic activities of cranberry is not known. Understanding these interactions is essential for assessing the feasibility of AV systems in cranberry production. In this study we evaluated eco-physiological and biochemical crop responses on a commercial ‘Howes’ cranberry bog grown under an agrivoltaics system using different row spacings in the year immediately following installation. Following installation of fixed tilt solar panels at a height of 3.0 m above the plant canopy, four shading treatments were evaluated: an uncovered control area and row spacings of 9.0 m, 7.0 m, and 5.0 m, corresponding to 30%, 35%, and 37% shading respectively. The shading effect was also evaluated at three different fruit developmental stages (green, blush, and full-red stage). Using microclimate sensors installed in the treatment areas, key eco-physiological and biochemical parameters, including leaf gas exchange, chlorophyll, anthocyanin, and antioxidant content, electrolyte leakage, proline and trehalose accumulation, were assessed. While moderate shading (30% and 35%) alleviated environmental stress, as reflected by improved leaf water status and reduced electrolyte leakage, these same treatments suppressed key physiological and metabolic functions, including photosynthetic activity, carbon reserve accumulation, and the biosynthesis of stress-related osmolytes and antioxidant compounds. Under higher shading (37%), these reductions were even more pronounced, indicating a potential threshold beyond which the benefits of shading are outweighed by declines in assimilate production and secondary metabolism. These findings highlight a trade-off between the stress-mitigating benefits of shading and the alterations in key physiological and metabolic processes under agrivoltaic systems. Minimizing these trade-offs by optimizing row spacing in agrivoltaics systems is critical to maintain cranberry physiological status. Since commercial cranberry is grown as a continuous plant canopy (no interrow spaces for equipment travel), damage caused by the installation process likely impacted crop response evaluated in the first year; multi-year studies are needed to fully understand the dynamics of a dual-use system. Notably, this work provides the first direct measurements of proline, trehalose content, and electrolyte leakage in cranberry grown under AV conditions, offering new insight into their physiological adjustments to shading.

14 SOLAR ENERGY↗

Effect of low-velocity or ballistic impact damage on the strength of thin composite and aluminum shear panels

Impact tests were conducted on shear panels fabricated from 6061-T6 aluminum and from woven fabric prepreg of Du Pont Kevlara fiber/epoxy resin and graphite fiber/epoxy resin. The shear panels consisted of three different composite laminates and one aluminum material configuration. Three panel aspect ratios were evaluated for each material configuration. Composite panels were impacted with a 1.27-cm (0.05-in) diameter aluminum sphere at low velocities of 46 m/sec (150 ft/sec) and 67 m/sec (220 ft/sec). Ballistic impact conditions consisted of a tumbled 0.50-caliber projectile impacting loaded composite and aluminum shear panels. The results of these tests indicate that ballistic threshold load (the lowest load which will result in immediate failure upon penetration by the projectile) varied between 0.44 and 0.61 of the average failure load of undamaged panels. The residual strengths of the panels after ballistic impact varied between 0.55 and 0.75 of the average failure strength of the undamaged panels. The low velocity impacts at 67 m/sec (220 ft/sec) caused a 15 to 20 percent reduction in strength, whereas the impacts at 46 m/sec (150 ft/sec) resulted in negligible strength loss. Good agreement was obtained between the experimental failure strengths and the predicted strength with the point stress failure criterion.

Farley, G. L.↗

Genetic Control of the Trigger for the G2/M Checkpoint

The work undertaken in this project addressed two seminal areas of low dose radiation biology that are poorly understood and controversial. These areas are the challenge to the linear-no-threshold (LNT) paradigm at low doses of radiation and, the fundamental elements of radiation bystander effect biology Genetic contributions to low dose checkpoint engagement: The LNT paradigm is an extrapolation of known, measured cancer induction endpoints. Importantly, data for lower doses is often not available. Debatably, radiation protection standards have been introduced which are prudently contingent on the adherence of cancer risk to the established trend seen at higher doses. Intriguing findings from other labs have hinted at separate DNA damage response programs that engage at low or high levels of radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reproductive success, early life stage development, and survival of westslope cutthroat trout (Oncorhynchus clarki lewisi) exposed to elevated selenium in an area of active coal mining

The effects of accumulated Se on the reproductive success and larval development of cutthroat trout (Oncorhynchus clarki lewisi) collected from a site of active coal mining in British Columbia were assessed. Eggs from 12 fish from an exposed site (Clode Pond) and 16 from a reference site (O'Rourke Lake) were field-collected and reared in the laboratory. Egg Se concentrations ranged from 12.3 to 16.7 and 11.8 to 140.0 {mu}g/g dry weight (dw) from fish collected at the reference and exposed sites, respectively. Other studies, including those with this species, have not shown Se to affect egg viability. However, in the present study, eggs with Se concentrations >86.3 {mu}g/g dw were not successfully fertilized or were nonviable at fertilization, while eggs with concentrations >46.8 and <75.4 {mu}g/g dw were fertilized (96% reached the eyed stage) but did not produce viable fry. A significant positive relationship between egg Se concentration and alevin mortality was observed. Deformities were analyzed in surviving fry which developed from eggs with Se concentrations between 11.8 and 20.6 {mu}g/g dw. No relationship between Se concentration in eggs and deformities or edema was found in this range, suggesting that the no-effect threshold for deformity is >20.6 {mu}g/g dw. The present data, in conjunction with the data from several other studies in temperate fish, suggest that current Se thresholds are conservative for cold-water fish. 25 refs., 3 figs.

01 COAL, LIGNITE, AND PEAT↗

Load Mitigating Feedback Control of WECs

This report outlines the development of load-mitigating feedback control for wave energy converters. A simple, self-tuning multi-objective controller is demonstrated in simulation for a 3-DOF (surge, heave, pitch) point absorber. In previous work, the proposed control architecture has been shown to be effective in experiment for a variety of device archetypes for the single objective of the maximization of electrical power capture: here this architecture is extended to reduce device loading as well. In particular, PTO actuation forces and the minimization of fatigue damage (determined from the sum of wave-exerted and PTO forces) are considered as additional objectives for the self-tuning controller. This controller is demonstrated for two similar, but distinct systems: one described by the identified linear models from physical testing of the WaveBot device, and another based upon a WEC-Sim simulation that expands upon boundary element method data from the WaveBot device. In both cases, because the power surface is consistently fairly flat in the vicinity of control parameters that maximize power capture in contrasting sea-states, it is found to be generally possible to mitigate either fatigue damage or PTO load. However, PTO load is found to conflict with fatigue damage in some sea-states, limiting the efficacy of control objectives that attempt to mitigate both simultaneously. Additionally, coupling between the surge and pitch DOFs also limits the extent to which fatigue damage can be mitigated for both DOFs in some sea-states. Because control objectives can be considered a function of the sea-state (e.g., load mitigation may not be a concern until the sea is sufficiently large) a simple transition strategy is proposed and demonstrated. This transition strategy is found to be effective with some caveats: firstly, it cannot circumvent the aforementioned objective contradictions. Secondly, this objective transition is too slow to act as a system constraint, and objective thresholds must thus be considered quite conservatively. Improvement of the adjustment strategy is demonstrated through the addition of an integral term. Selection of well-performing transition parameters can be a function of sea-state. While a simple selection procedure is proposed, it is non-optimal, and a more robust selection procedure is suggested for future work.

16 TIDAL AND WAVE POWER↗

Regional Normal Lung Tissue Density Changes in Patients Treated With Stereotactic Body Radiation Therapy for Lung Tumors

Purpose: To describe regional lung tissue density changes in normal lung tissue of patients with primary and metastatic lung tumors who received stereotactic body radiation therapy (SBRT). Methods and Materials: A total of 179 post-SBRT follow-up computed tomography (CT) scans of 62 patients who received SBRT between 2003 and 2009 were studied. Median prescription dose was 54 Gy (range, 30-60 Gy) in 3 to 5 fractions. SBRT-induced lung density changes on post-SBRT follow-up CT were evaluated at approximately 3, 6, 12, 18, 24, and 30 months after treatment. Dose-response curves (DRC) were generated for SBRT-induced lung damage by averaging CT number (HU) changes for regions of the lungs receiving the same dose at 5-Gy intervals. Results: For all follow-up interval periods, CT numbers linearly increased with dose until 35 Gy and were constant thereafter. For 3, 18, 24, and 30 months, the rate of relative electron density increase with dose was approximately 0.24% per Gy. At 6 months, the rate was also similar below 20 Gy but then rose to 0.6% per Gy above this threshold. After 6 months, DRCs were mostly time-independent. When split between patients treated with 3 fractions of 12 to 20 Gy (median, 20 Gy; average tumor volume, 12 {+-} 16 cm{sup 3}) and with >3 fractions of 6 to 12.5 Gy (median, 9 Gy; average tumor volume, 30 {+-} 40 cm{sup 3}), DRCs differed significantly. In both cases, CT changes at 3, 18, 24, and 30 months were identical to those of the population DRC; however, patients who received >3 fractions showed 6-month CT changes that were more than twice those for the group that received 3 fractions. Conclusions: This analysis of SBRT-induced normal lung density changes indicates that lung normal tissue has more pronounced self-limited acute effects than late effects. Differences in acute CT changes following treatments in 3 fractions were considerably less than for treatments in >3 fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗