CdTe Focal Plane Detector for Hard X-Ray Focusing Optics

The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.

X-ray↗

Status of the Micro-X Sounding Rocket X-Ray Spectrometer

Micro-X is a sounding rocket borne X-ray telescope that utilizes transition edge sensors to perform imaging spectroscopy with a high level of energy resolution. Its 2.1m focal length X-ray optic has an effective area of 300 sq cm, a field of view of 11.8 arcmin, and a bandpass of 0.12.5 keV. The detector array has 128 pixels and an intrinsic energy resolution of 4.5 eV FWHM. The integration of the system has progressed with functional tests of the detectors and electronics complete, and performance characterization of the detectors is underway. We present an update of ongoing progress in preparation for the upcoming launch of the instrument.

X-ray astronomy↗

Real-time Anomaly Detection for Liquid Argon Time Projection Chambers

We present a real-time anomaly detection framework for liquid argon time projection chambers (LArTPCs), targeting applications in particle physics experiments such as the Short Baseline Near Detector (SBND) or the future Deep Underground Neutrino Experiment (DUNE). These experiments employ detectors that generate and stream high-resolution but sparse images of neutrino and other particle interactions. Our approach utilizes anomaly detection with autoencoders, compressed through knowledge distillation (KD), to enable the detection of anomalous signals in the data through efficient inference on resource-constrained hardware. The framework is targeted for deployment on computing platforms equipped with field-programmable gate arrays (FPGAs), GPUs, or CPUs, allowing low-latency selection of relevant activity directly from the raw detector data stream. We demonstrate that our approach is suitable for the detection and localization of anomalously "high-multiplicity" activity, and outline promising applications for LArTPC online data filtering and triggering.

FOS: Physical sciences↗

Commission < 5 µm spatial resolution x-ray imager for High Resolution Turbulence experiments

This report presents the successful development, commissioning, and deployment of the Scintillation-Based X-ray Imager (SBXI) for the High-Resolution Turbulence (HRT) campaign at the National Ignition Facility (NIF). The SBXI system was designed to overcome the spatial resolution and efficiency limitations of conventional x-ray imaging detectors. Through careful system engineering, rigorous laboratory characterization, and experimental validation at NIF, the SBXI has demonstrated spatial resolution at the object plane of 5 μm (±0.5 μm) and a detective quantum efficiency (DQE) of 34% at 7.2 keV, both of which surpass the requirements set by the campaign, and meeting the L2 milestone. The system’s deployment enables high-fidelity imaging of fine-scale hydrodynamic instabilities, directly supporting advanced turbulence model validation and future high energy density physics research.

42 ENGINEERING↗

System description

The VAS, carried onboard the GOES 4 and 5 satellites, is a radiometer with 8 visible channel detectors and 6 thermal detectors that detect infrared radiation in 12 spectral bands. A filter wheel in front of the detector is used to achieve the spectral selection. The spatial resolution is 0.9 kilometer in the visible and 7 or 14 kilometers in the infrared depending on the detector used. Full Earth disk coverage is accomplished by spinning in the west to east direction at 100 rpm and by stepping a scan mirror from north to south. Additional VAS instrument characteristics are summarized. The VAS has three operating modes: the operational VISSR mode, the multispectral imaging (MSI) mode, and the dwell sounding (DS) mode. The operational VISSR mode is used by NOAA/NESS for its operational products, which include a visible picture and an 11 micrometer infrared (channel 8) picture at half hour intervals. The other modes are VAS unique. The MSI mode combines the operational VISSR capability (visible plus infrared window) with two additional spectral channels to provide half hourly full Earth disk imagery of atmospheric water vapor, temperature, and cloud distribution. The DS mode is used primarily for sounding to obtain the temperature and moisture profiles. In this mode, multiple spins on the same scan line in a given band are averaged to obtain the required signal to noise ratio for sounding.

Montgomery, H.↗

EXOSS - A hard X-ray and soft gamma-ray astronomy mission

The Energetic X-ray Observatory on Space Station (EXOSS) is a mission concept for high-sensitivity coded-aperture sky surveys and studies of the spectral and temporal behavior of astrophysical sources from approximately 3 keV to 1 MeV. The scientific motivation for the mission and the instrument requirements, including the need for high angular resolution to resolve and identify numerous detectable sources, are summarized. Two baseline telescopes are described: one employing a 1.4-sq-m array of Xe gas imaging proportional counters to cover the 3 to 100 keV range with 1 arcmin resolution; the second using a 2.8-sq-m array of NaI/CsI imaging phoswich detectors to span the 20 keV to MeV range with 12 arcmin resolution.

Cook, W. R.↗

CdZnTe Image Detectors for Hard-X-Ray Telescopes

Arrays of CdZnTe photodetectors and associated electronic circuitry have been built and tested in a continuing effort to develop focal-plane image sensor systems for hard-x-ray telescopes. Each array contains 24 by 44 pixels at a pitch of 498 m. The detector designs are optimized to obtain low power demand with high spectral resolution in the photon- energy range of 5 to 100 keV. More precisely, each detector array is a hybrid of a CdZnTe photodetector array and an application-specific integrated circuit (ASIC) containing an array of amplifiers in the same pixel pattern as that of the detectors. The array is fabricated on a single crystal of CdZnTe having dimensions of 23.6 by 12.9 by 2 mm. The detector-array cathode is a monolithic platinum contact. On the anode plane, the contact metal is patterned into the aforementioned pixel array, surrounded by a guard ring that is 1 mm wide on three sides and is 0.1 mm wide on the fourth side so that two such detector arrays can be placed side-by-side to form a roughly square sensor area with minimal dead area between them. Figure 1 shows two anode patterns. One pattern features larger pixel anode contacts, with a 30-m gap between them. The other pattern features smaller pixel anode contacts plus a contact for a shaping electrode in the form of a grid that separates all the pixels. In operation, the grid is held at a potential intermediate between the cathode and anode potentials to steer electric charges toward the anode in order to reduce the loss of charges in the inter-anode gaps. The CdZnTe photodetector array is mechanically and electrically connected to the ASIC (see Figure 2), either by use of indium bump bonds or by use of conductive epoxy bumps on the CdZnTe array joined to gold bumps on the ASIC. Hence, the output of each pixel detector is fed to its own amplifier chain.

Chen, C. M. Hubert↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗

High-resolution observations of gamma-ray line emission from SN 1987A

Observations of SN 1987A made with a balloon-borne gamma-ray spectrometer comprising an array of high-purity germanium detectors on October 29-31, 1987 are presented. High resolution data, typically 2.5 keV at 1.33 MeV, were obtained for two transists of the supernova with interspersed background data. A preliminary estimation of line flux is presented. It is found that there is evidence of dynamical broadening of the 847 keV line. It is suggested that this line may be an emission from the first excited state of Fe-56 due to the radioactive decay of Co-56 providing evidence for nucleosynthesis in the supernova.

Sandie, W. G.↗

Performance and durability of HgI2 X-ray detectors for space missions

Considerable progress has been achieved recently in HgI2 detector fabrication technology and amplification electronics. An energy resolution of 198 eV (full width at half maximum) has been obtained for the Mn k-alpha line of 5.9 keV in a practical X-ray probe without the use of cryogenic cooling. Detectors prepared with Parylene-C encapsulation have demonstrated perfect reliability in two-year tests under high vacuum and temperature and bias cycling. Other HgI2 detectors have been used to demonstrate proton-radiation-damage resistance to levels of 10 to the 12 protons/sq cm at 10.7 MeV. It is concluded that HgI2 detectors are suitable for the ordinary requirements of energy dispersive detectors in X-ray spectroscopy systems.

Iwanczyk, J. S.↗

Suomi NPP VIIRS DNB and RSB M Bands Detector-To-Detector and HAM Side Calibration Differences Assessment Using a Homogenous Ground Target

Near-nadir observations of the Libya 4 site from the S-NPP VIIRS Day-Night Band (DNB) and Moderate resolution Bands (M bands) are used to assess the detector calibration stability and half-angle mirror (HAM) side differences. Almost seven years of Sensor Data Records products are extracted from the Libya 4 site center over an area of 32×32 pixels. The mean values of the radiance from individual detectors per HAM side are computed separately. The comparison of the normalized radiance between detectors indicates that the detector calibration differences are wavelength dependent and the differences have been slowly increasing with time for short wavelength bands, especially for M1-M4. The maximum annual average differences between DNB detectors are 0.77% in 2017 at HAM-A. For the M bands, the maximum detector differences in 2017 are 1.7% for M1, 1.8% for M2, 1.3% for M3, 1.2% for M4, 0.67% for M5, 0.75% for M7, 0.57% for M8, 13% for M9, 0.63% for M10, and 0.66% for M11. The average HAM side A to B difference in 2017 are 0.00% for DNB, 0.22% for M1, 0.17% for M2, 0.15% for M3, 0.09% for M4, -0.07% for M5, 0.02% for M7, 0.01% for M8, 1.4% for M9, 0.01% for M10, and 0.03% for M11. Results for M6 are not available due to the signal saturation and M9 results are not accurate because of the low reflectance from the desert site and the strong atmospheric absorption in this channel. The results in this study help scientists better understand each detector’s performance and HAM side characteristics. Additionally, they provide evidence and motivation for future VIIRS calibration improvements.

SNPP VIIRS↗

High resolution spectrograph for the Space Telescope

The high resolution spectrograph (HRS) for ultraviolet astronomy with the Space Telescope will provide a spectral resolution of approximately 120,000 over a nominal wavelength range of 110-320 nm, together with a spatial resolution of about 0.25 arc seconds. The two detectors will consist of 512-element Digicons with cesium telluride and cesium iodide photocathodes, respectively. Photoelectrons in transit between the photocathodes and the diodes within the Digicons can be deflected in two axes with 12-bit resolution. This feature facilitates a design that emphasizes reliability since (once a hermetic seal is opened in orbit), only two moving parts, a grating carrousel and a shutter, are required for regular operation of the HRS. The instrument will be controlled by a computer in the spacecraft. The scientific objectives of the HRS investigation relate to interstellar matter in our own and nearby galaxies, physical processes of stellar mass loss and mass transfer, chemical abundances, bright quasars and Seyfert galaxy nuclei, and solar system phenomena.

Brandt, J. C.↗

Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout

The study of solar neutrinos presents significant opportunities in astrophysics, nuclear physics, and particle physics. However, the low-energy nature of these neutrinos introduces considerable challenges to isolate them from background events, requiring detectors with low-energy threshold, high spatial and energy resolutions, and low data rate. We present the study of solar neutrinos with a kiloton-scale liquid argon detector located underground, instrumented with a pixel readout using the Q-Pix technology. We explore the potential of using volume fiducialization, directional topological information, light signal coincidence, and pulse-shape discrimination to enhance solar neutrino sensitivity. We find that discriminating neutrino signals below 5 MeV is very difficult. However, we show that these methods are useful for the detection of solar neutrinos when external backgrounds are sufficiently understood and when the detector is built using low-background techniques. When building a workable background model for this study, we identify 𝛾 background from the cavern walls and from capture of 𝛼 particles in radon decay chains as both critical to solar neutrino sensitivity and significantly underconstrained by existing measurements. Finally, we highlight that the main advantage of the use of Q-Pix for solar neutrino studies lies in its ability to enable the continuous readout of all low-energy events with minimal data rates and manageable storage for further off-line analyses.

multi-purpose particle detectors↗

Infrared Fourier spectrometer for airborne and ground-based astronomy

A unique high resolving power near-infrared, astronomical Fourier spectrometer has been constructed for use at both ground-based and airborne telescopes. Its capabilities include a limiting resolution of 0.01/cm and spectral coverage over the InSb detector sensitivity region (0.8-5.6 micron). The instrument is optimized for operation in environments inaccessible to other high-resolution Fourier spectrometers, namely, the Cassegrain focuses of conventional telescopes and the NASA Kuiper Airborne Observatory's 91-cm telescope. Details of the spectrometer are discussed, and various astronomical and laboratory spectra are presented.

Davis, D. S.↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Electron Diffusion and Constraining the Neutral Current $\pi^0$ Background for Single-Photon Events in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are a rising technology in the field of experimental neutrino physics. LArTPCs use ionization electrons and scintillation light to reconstruct neutrino interactions with exceptional calorimetric and position resolution capabilities. Here, I present two analyses conducted in the MicroBooNE LArTPC at Fermilab: a measurement of the longitudinal electron diffusion coefficient, $D_L$, in the MicroBooNE detector and a constraint of the systematic uncertainty on MicroBooNE's single-photon analysis due to the dominant neutral current (NC) \piz{} background. Longitudinal electron diffusion modifies the spatial and timing resolution of the detector, and measuring it will help correct for these effects. Furthermore, current measurements of $D_L$ in liquid argon are sparse and in tension with one another, making the MicroBooNE measurement especially valuable. We report a measurement of $3.74^{+0.28}_{-0.29}$ cm$^2$/s. MicroBooNE is searchin g for si ngle-photon events as a potential explanation for the MiniBooNE low-energy excess (LEE) of electron neutrino-like events, which has been interpreted as evidence for low-mass sterile neutrinos. However, this search is overwhelmed by a large NC \piz{} background. By performing a sideband selection of NC \piz{} events, we apply a data-driven rate constraint to the single-photon analysis to reduce the systematic uncertainties. At present, this constraint improves the single-photon analysis' median sensitivity to the LEE-like signal from 0.9$\sigma$ to $1.5\sigma$. This sensitivity is expected to improve significantly as more data become available. Both of these measurements will not only benefit MicroBooNE, but also inform future LArTPC experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of the Double Etalon Fabry-Perot Interferometer for Determining Total and Tropospheric Ozone Concentrations

Measuring and understanding the distribution of ozone through the lower levels of Earth's atmosphere are high priorities in global change and climate research. Of particular interest now is the global distribution of ozone in the upper troposphere and lower stratosphere. Global coverage of the stratospheric ozone is feasible only via remote sensing instruments on a space-based platform. And though extensive monitoring tropospheric ozone is possible using instruments flown aboard conventional aircraft, a space-based system would be significantly less costly and provide information over a much broader area and produce more uniform coverage. Here we describe the prototype of an instrument being developed to monitor, from an orbiting spacecraft, the ozone found in Earth's upper troposphere and lower stratosphere. Our new spectrometer is an infrared Fabry-Perot interferometer which uses two synchrounously tuned etalons: a high resolution narrow band device and a lower resolution broader band filtering etalon. The prototype is a scanning device making use of nearly collimated input radiation and a single element detector. As presently configured, it is capable of providing a resolution better than 0.07/cm with a spectral band width approximately 5/cm wide and centered at 1054.7/cm. For the future space-based emission device a modification of the the prototype was to be made to employ innovative circle-to-line detector optics, those developed or in development at UM/SPRL, and a focal plane array detector. These enhancements would enable a simultaneous recording of the entire spectral range of interest, but with simple detection electronics and a significant gain in signal-to-noise over that of the scanning version.

Cook, William↗