Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY↗

Development of HEK-293 Cell Lines Constitutively Expressing Flaviviral Antigens for Use in Diagnostics

Flaviviruses are important human pathogens worldwide. Diagnostic testing for these viruses is difficult because many of the pathogens require specialized biocontainment. To address this issue, we generated 39 virus-like particle (VLP)- and nonstructural protein 1 (NS1)-secreting stable cell lines in HEK-293 cells of 13 different flaviviruses, including dengue, yellow fever, Japanese encephalitis, West Nile, St. Louis encephalitis, Zika, Rocio, Ilheus, Usutu, and Powassan viruses. Antigen secretion was stable for at least 10 cell passages, as measured by enzyme-linked immunosorbent assays and immunofluorescence assays. Thirty-five cell lines (90%) had stable antigen expression over 10 passages, with three of these cell lines (7%) increasing in antigen expression and one cell line (3%) decreasing in antigen expression. Antigen secretion in the HEK-293 cell lines was higher than in previously developed COS-1 cell line counterparts. These antigens can replace current antigens derived from live or inactivated virus for safer use in diagnostic testing.

59 BASIC BIOLOGICAL SCIENCES↗

Study of Mechanical and Thermal Impact of a Plasma Focus Discharge on Diagnostic Elements of PFM-72M Installation

Mechanical and thermal impact of the plasma focus discharge on structural elements of diagnostic windows of the PFM-72m discharge installation are calculated. The absence of critical impact at early discharge stages and during the first 300 ns after the “plasma focus” formation is shown. The possibility of shock impact on the surface of diagnostic windows at later times, which may result in their substantial deformation and destruction, is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron Diagnostics for Deuteron Flows from Pulsed Plasma Formations in a Magnetic Field

A diagnostic procedure establishing a relation between the energy of a laser pulse W (0.1 ≤ W ≤ 0.8) and the number of deuterons N{sub d} extracted from the laser plasma in a vacuum accelerating diode with magnetic isolation of electrons is presented. The diagnostics is based on the measurement of neutrons generated at a target, which is a part of the ion collector at the same time. The results of experimental research and numerical modeling for the accelerating voltage at a diode interval up to 400 kV are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics of plasma produced by femtosecond laser pulse impact upon a target with an internal nanostructure

X-ray diagnostics of the interaction of femtosecond laser pulses with intensities of 10{sup 16}-10{sup 18} W/cm{sup 2} with CO{sub 2} clusters and frozen nanosize water particles is carried out. The stage of cluster expansion and the formation of a plasma channel, which governs the parameters of the formed X-ray radiation source and accelerated ion flows, is studied. The measurements are based on recording spatially resolved X-ray spectra of H- and He-like oxygen ions. Utilization of Rydberg transitions for spectra diagnostics makes it possible to determine plasma parameters on a time scale of t {approx} 10 ps after the beginning of a femtosecond pulse. The role of the rear edge of the laser pulse in sustaining the plasma temperature at a level of {approx}100 eV in the stage of a nonadiabatic cluster expansion is shown. The analysis of the profiles and relative intensities of spectral lines allows one to determine the temperature and density of plasma electrons and distinguish the populations of 'thermal' ions and ions that are accelerated up to energies of a few tens of kiloelectronvolts. It is shown that the use of solid clusters made of frozen nanoscale water droplets as targets leads to a substantial increase in the number of fast He-like ions. In this case, however, the efficiency of acceleration of H-like ions does not increase, because the time of their ionization in plasma exceeds the time of cluster expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specific features of measuring the isotopic composition of hydrogen ions in ITER plasma by using neutral particle diagnostics under neutral beam injection conditions

Results of numerical simulation of signals from neutral particle analyzers under injection of the heating and diagnostic neutral beams in different operating modes of the ITER tokamak are presented. The distribution functions of fast ions in plasma are simulated, and the corresponding neutral particle fluxes escaping from the plasma along the line of sight of the analyzers are calculated. It is shown that the injection of heating deuterium (D{sup 0}) beams results in the appearance of an intense background signal hampering measurements of the ratio between the densities of deuterium and tritium fuel ions in plasma in the thermal energy range. The injection of a diagnostic hydrogen (H{sup 0}) beam does not affect measurements owing to the high mass resolution of the analyzers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Simple and Rapid Diagnostic Method for Polymer-Electrolyte Fuel Cells

A simple and fast diagnostic tool has been developed for analyzing polymer-electrolyte fuel-cell degradation. The tool is based on analyzing changes in polarization curves of a cell over its lifetime. The shape of the polarization-change curve and its sensitivity to oxygen concentration are found to be unique for each degradation pathway based on analysis from a detailed 2-D numerical model of the cell. Using the polarization-change curve methodology, the primary mechanism for degradation (kinetic, ohmic, and/or transport related) can be identified. Here, the technique is applied to two sets of data to explain performance changes after two different cells undergo voltage-cycling accelerated stress test, where it is found that changes are kinetic and then ohmic or transport in nature depending on the cell type. The diagnostic tool provides a simple method for rapid determination of primary degradation mechanisms. Finally, areas for more detailed future investigations are also summarized.

08 HYDROGEN↗

IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms

To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry program, Dose and Risk Calculation (DCAL), that employs the same computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. The absorbed doses and effective dose of 131 I-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered 18 F-FDG and orally administered 99m Tc-pertechnetate and 131 I-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for 18 F-FDG, 0.014 mSv/MBq for 99m Tc-pertechnetate, and 16 mSv/MBq for 131 I-iodide. The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid opto-electric techniques for molecular diagnostics

Hybrid optoelectric techniques reflect a new paradigm in microfluidics. In essence, these are microfluidic techniques that employ a synergistic combination of optical and electrical forces to enable noninvasive manipulation of fluids and/or particle-type entities at the micro/nano-scale [1]. Synergy between optical and electrical forces bestows these techniques with several unique features that are promising to bring new opportunities in molecular diagnostics. Within the scope of molecular diagnostics, several aspects of optoelectric techniques promise to play a relevant role. These include, but are not limited to, sample preparation, sorting, purification, amplification and detection.

99 GENERAL AND MISCELLANEOUS↗

STELLOPT Modeling of the 3D Diagnostic Response in ITER

The ITER three dimensional diagnostic response to an n=3 resonant magnetic perturbation is modeled using the STELLOPT code. The in-vessel coils apply a resonant magnetic perturbation (RMP) fi eld which generates a 4 cm edge displacement from axisymmetry as modeled by the VMEC 3D equilibrium code. Forward modeling of flux loop and magnetic probe response with the DIAGNO code indicates up to 20 % changes in measured plasma signals. Simulated LIDAR measurements of electron temperature indicate 2 cm shifts on the low field side of the plasma. This suggests that the ITER diagnostic will be able to diagnose the 3D structure of the equilibria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FY19 L2 MRT 6744 Milestone Completion: Digital Time-Resolved Spot Diagnostic (D-TRSD)

This milestone report describes development of the Digital Time-Resolved Spot Diagnostic (D-TRSD) into a functioning diagnostic that has been proven in the laboratory. Laboratory tests complete the MRT 6744 exit criteria with the recording and analysis of a spot size measurement for two consecutive pulses on a two-pulse source. Additional channels will be added in the near future to provide an 84-channel measurement capability. The new modular design is more portable than the previous generations and will be much easier to set up at radiographic facilities across the complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

Rooftop units (RTUs) and other packaged systems are very common in commercial buildings in the U.S., and they often have minimal controls and poor performance. Automated fault detection and diagnostics (AFDD) is a powerful tool that can continuously monitor operating equipment, detect abnormal performance, diagnose problems, and report findings to building operators. AFDD technologies for RTUs have been under development for many years and have recently begun to enter the market in a significant way. There are several AFDD systems available for RTUs that feature a wide range of designs, capabilities, and reporting. Unfortunately, there is little consistency among the AFDD applications and little understanding of the performance and value of these systems. This study presents analysis of AFDD data provided by four companies from over 28,000 RTUs, five building types, and multiple climate zones. The objectives of this investigation were to gain a better understanding of how RTU AFDD systems operate, the types and frequencies of faults identified, and how building operators interact with these systems. The monitoring of a variety of RTUs provides insights into the AFDD monitoring inputs, faults, and diagnostics from which these tools are capable of informing building owners about the status of their HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

Rooftop units (RTUs) and other packaged systems are very common in commercial buildings in the U.S., and they often have minimal controls and poor performance. Automated fault detection and diagnostics (AFDD) is a powerful tool that can continuously monitor operating equipment, detect abnormal performance, diagnose problems, and report findings to building operators. AFDD technologies for RTUs have been under development for many years and have recently begun to enter the market in a significant way. There are several AFDD systems available for RTUs that feature a wide range of designs, capabilities, and reporting. Unfortunately, there is little consistency among the AFDD applications and little understanding of the performance and value of these systems. This study presents analysis of AFDD data provided by four companies from over 28,000 RTUs, five building types, and multiple climate zones. The objectives of this investigation were to gain a better understanding of how RTU AFDD systems operate, the types and frequencies of faults identified, and how building operators interact with these systems. The monitoring of a variety of RTUs provides insights into the AFDD monitoring inputs, faults, and diagnostics from which these tools are capable of informing building owners about the status of their HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A laser inverse Compton scattering diagnostic to study runaway electron dynamics during tokamak disruptions

The goal is to design a new diagnostic based on laser inverse Compton scattering (LICS) to study the dynamics of runaway electron formation and their subsequent loss during triggered disruptions in DIII-D. It is known that better measurements of the runaway electron population, throughout the evolution of a disruption, is critical for mitigating the impact of energetic electron beams especially in high plasma current discharges such as those in reactor relevant burning plasmas. The goal of the LICS approach being designed for DIII-D is to measure the timeresolved spatial profile and energy distribution of the runaway electrons while they are in the core of the tokamak plasma. During the last year, a code was developed to simulate the signals from a new laser scattering diagnostic for DIII-D, which will measure the relativistic electron population expected in DIII-D after disruptions triggered by argon pellet injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Novel 'Smart Microchip Proppants' Technology for Precision Diagnostics of Hydraulic Fracture Networks (Edited Final Report)

This project introduces innovative technology to improve subsurface characterization, visualization, and diagnostics of unconventional reservoirs (fossil resources). Through a collaborative effort involving the University of Kansas, UCLA, MicroSilicon Inc., and EOG Resources, the project aims to deliver precision diagnostics for hydraulic fractures using novel high-resolution imaging technology based on smart microchip proppants. Additionally, it seeks to enhance the accuracy and predictability of integrated numerical, and machine-learning modeling techniques for hydraulic fracture characterization and simulation. This groundbreaking technology addresses significant gaps in understanding unconventional and tight reservoir behavior and optimizing well-completion strategies, enabling more cost-efficient recovery of unconventional resources.

02 PETROLEUM↗

Development of a high-temperature diagnostics-while-drilling tool.

The envisioned benefits of Diagnostics-While-Drilling (DWD) are based on the principle that high-speed, real-time information from the downhole environment will promote better control of the drilling process. Although in practice a DWD system could provide information related to any aspect of exploration and production of subsurface resources, the current DWD system provides data on drilling dynamics. This particular set of new tools provided by DWD will allow quicker detection of problems, reduce drilling flat-time and facilitate more efficient drilling (drilling optimization) with the overarching result of decreased drilling costs. In addition to providing the driller with an improved, real-time picture of the drilling conditions downhole, data generated from DWD systems provides researchers with valuable, high fidelity data sets necessary for developing and validating enhanced understanding of the drilling process. Toward this end, the availability of DWD creates a synergy with other Sandia Geothermal programs, such as the hard-rock bit program, where the introduction of alternative rock-reduction technologies are contingent on the reduction or elimination of damaging dynamic effects. More detailed descriptions of the rationale for the program and early development efforts are described in more detail by others [SAND2003-2069 and SAND2000-0239]. A first-generation low-temperature (LT) DWD system was fielded in a series of proof-of-concept tests (POC) to validate functionality. Using the LT system, DWD was subsequently used to support a single-laboratory/multiple-partner CRADA (Cooperative Research and Development Agreement) entitled Advanced Drag Bits for Hard-Rock Drilling. The drag-bit CRADA was established between Sandia and four bit companies, and involved testing of a PDC bit from each company [Wise, et al., 2003, 2004] in the same lithologic interval at the Gas Technology Institute (GTI) test facility near Catoosa, OK. In addition, the LT DWD system has been fielded in cost-sharing efforts with an industrial partner to support the development of new generation hard-rock drag bits. Following the demonstrated success of the POC DWD system, efforts were initiated in FY05 to design, fabricate and test a high-temperature (HT) capable version of the DWD system. The design temperature for the HT DWD system was 225 C. Programmatic requirements dictated that a HT DWD tool be developed during FY05 and that a working system be demonstrated before the end of FY05. During initial design discussions regarding a high-temperature system it was decided that, to the extent possible, the HT DWD system would maintain functionality similar to the low temperature system, that is, the HT DWD system would also be designed to provide the driller with real-time information on bit and bottom-hole-assembly (BHA) dynamics while drilling. Additionally, because of time and fiscal constraints associated with the HT system development, the design of the HT DWD tool would follow that of the LT tool. The downhole electronics package would be contained in a concentrically located pressure barrel and the use of externally applied strain gages with thru-tool connectors would also be used in the new design. Also, in order to maximize the potential wells available for the HT DWD system and to allow better comparison with the low-temperature design, the diameter of the tool was maintained at 7-inches. This report discusses the efforts associated with the development of a DWD system capable of sustained operation at 225 C. This report documents work performed in the second phase of the Diagnostics-While-Drilling (DWD) project in which a high-temperature (HT) version of the phase 1 low-temperature (LT) proof-of-concept (POC) DWD tool was built and tested. Descriptions of the design, fabrication and field testing of the HT tool are provided. Background on prior phases of the project can be found in SAND2003-2069 and SAND2000-0239.

42 ENGINEERING↗

Pediatric Tuberculosis: The Impact of “Omics” on Diagnostics Development

Tuberculosis (TB) is a major public health concern for all ages. However, the disease presents a larger challenge in pediatric populations, partially owing to the lack of reliable diagnostic standards for the early identification of infection. Currently, there are no biomarkers that have been clinically validated for use in pediatric TB diagnosis. Identification and validation of biomarkers could provide critical information on prognosis of disease, and response to treatment. In this review, we discuss how the “omics” approach has influenced biomarker discovery and the advancement of a next generation rapid point-of-care diagnostic for TB, with special emphasis on pediatric disease. Limitations of current published studies and the barriers to their implementation into the field will be thoroughly reviewed within this article in hopes of highlighting future avenues and needs for combating the problem of pediatric tuberculosis.

59 BASIC BIOLOGICAL SCIENCES↗

Emission Line Ratios of FE III as Astrophysical Plasma Diagnostics

Recent, state-of-the-art calculations of A-values and electron impact excitation rates for Fe iii are used in conjunction with the Cloudy modeling code to derive emission-line intensity ratios for optical transitions among the fine-structure levels of the 3d{sup 6} configuration. A comparison of these with high-resolution, high signal-to-noise spectra of gaseous nebulae reveals that previous discrepancies found between theory and observation are not fully resolved by the latest atomic data. Blending is ruled out as a likely cause of the discrepancies, because temperature- and density-independent ratios (arising from lines with common upper levels) match well with those predicted by theory. For a typical nebular plasma with electron temperature T{sub e}=9000 K and electron density N{sub e}=10{sup 4} cm{sup −3}, cascading of electrons from the levels {sup 3}G{sub 5}, {sup 3}G{sub 4} and {sup 3}G{sub 3} plays an important role in determining the populations of lower levels, such as {sup 3}F{sub 4}, which provide the density diagnostic emission lines of Fe iii, such as {sup 5}D{sub 4} - {sup 3}F{sub 4} at 4658 Å. Hence, further work on the A-values for these transitions is recommended, ideally including measurements if possible. However, some Fe iii ratios do provide reliable N{sub e}-diagnostics, such as 4986/4658. The Fe iii cooling function, calculated with Cloudy using the most recent atomic data, is found to be significantly greater at T {sub e} ≃ 30,000 K than predicted with the existing Cloudy model. This is due to the presence of additional emission lines with the new data, particularly in the 1000–4000 Å wavelength region.

79 ASTRONOMY AND ASTROPHYSICS↗