Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficient envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

Physical models of Comet Halley based upon qualitative data from the 1910 apparition

A semi-empirical theory was developed, tying the hydrogen production rate of a comet to its visual light curve. Two unknown constants, which are essentially the efficiencies of these two processes, are derived from the comets for which quantitative data exist. This theory has been applied to P/Halley, using the light curve of Yeomans, which was derived from the original 1910 observations, with aperture corrections applied. Given the hydrogen production rate, it is assumed that N(H20) = 0.5 N(H) and that there is 0.2 N(H20) of other species. From several converging lines of evidence the mass of dust is taken as half the mass of gas. The Sekanina-Miller distribution function of particle size is used. Particle velocities are calculated using Delsemmes version of the Probstein theory. From these, near nucleus dust density, flux, etc. are calculated. Dust envelope sizes are calculated from the old mechanical theory of tails. Extreme models are calculated from the old mechanical theory of tails. Extreme models are also furnished based upon a "sum-of-negative-tolerance" approach.

Newburn, R. L.↗

Space station group activities habitability module study: A synopsis

Space station habitability was studied by investigating crew activity routines, proximities, ergonomic envelopes, and group volumes. Ten alternative schematic interior designs were proposed. Preliminary conclusions include: (1) in-service interior modifications may be necessary and should be planned for; (2) design complexity will be increased if the module cluster is reduced from five to three; (3) the increased crew circulation attendant upon enhancement of space station activity may produce human traffic bottlenecks and should be planned for; (4) a single- or two-person quiet area may be desirable to provide crew members with needed solitude during waking hours; and (5) the decision to choose a two-shift or three-shift daily cycle will have a significant impact on the design configuration and operational efficiency of the human habitat.

Nixon, David↗

In-Situ Measurement of the Height of Condensed Water in Steam Pipes with Dynamic Flow

A method based on the use of enhanced filtered Hilbert envelope of the wave signal was developed in order to monitor the height of condensed water through the wall of steam pipes having dynamic flow conditions. A prototype testbed was designed and fabricated in this study to simulate the dynamic flow conditions including the air stream flowing above the water and bubble induced disturbance. A dual-transducer was used to perform the test as a basis for the multiple transducers system to facilitate the detectability and reliability for long term monitoring of the condensed water height in dynamic conditions. The results demonstrated that the method of measuring the water height using multiple-transducer system employing the developed novel signal processing technique is an efficient and accurate tool for practical applications.

water level in pipe↗

Thermal Management by Engineering the Alignment of Nanocellulose

One of the grand current research challenges is to improve the energy efficiency of residential and commercial buildings, which cumulatively consume more than 40% of the energy generated globally. In addition to improving the comfort of the inhabitants and mitigating the growing energy consumption problem, new building materials and technologies could provide a safe strategy for geoengineering to mitigate global climate change. Herein, recent progress in developing such advanced materials from nanocellulose, which is often derived from wood or even dirty feedstocks like waste, is reviewed. By using chemical and bacteria-enabled processing, nanocellulose can be used to fabricate broadband photonic reflectors, thermally super-insulating aerogels, solar gain regulators, and low-emissivity coatings, with potential applications in windows, roofs, walls, and other components of buildings envelopes. These material developments draw inspiration from advanced energy management found in nature, such as the nanoporous photonic structures that evolved in cuticles of beetles. Fabrication of such materials takes advantage of mesoscale liquid crystalline self-assembly, which allows for pre-designed control of cellulose nanoparticle orientations at the mesoscale. Finally, with the potential fully realized, such materials could one day transform the current energy-lossy buildings into energy plants on Earth and possibly even enable extraterrestrial habitats.

36 MATERIALS SCIENCE↗

Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods

The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Utilities (TPU) and the Bonneville Power Administration. The Woods is a Habitat for Humanity (HFH) community of homes certified by ENERGY STAR Homes Northwest (ESHNW); the community is in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report and includes significant billing analysis and cost-effectiveness research from a collaborative and ongoing DHP research effort for TPU and the Bonneville Power Administration. This final BA report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing. The research goal of the U.S. Department of Energy's BA research team Building America Partnership for Improved Residential Construction was to compare a ductless heat pump (DHP) hybrid system (DHP in common area/electric resistance [ER] in bedrooms) to an all-electric zonal ER system in high-performance single-family affordable housing. This effort included assessing the costs and benefits of a DHP/ER hybrid system located in the main living area to offset the primary heating demand of zonal ER heaters in the bedroom zones and comparing these findings to data from of new affordable single-family housing in Washington State. This report includes: (1) Measured indoor and outdoor temperatures and relative humidity (RH) in the homes. (2) Field testing results of heating, ventilating, and air-conditioning equipment; ventilation system airflows; building envelope tightness; lighting, appliance, and other input data required for preliminary Building Energy Optimization (BEopt) modeling; and ENERGY STAR field verification (3) BEopt modeling results compared to measured energy use. (4) A comparison of the space heat energy consumption of a DHP/ER hybrid heating system and a traditional zonal ER heating system installed in the same home. This comparison is made by implementing a series of weekly "flip-flop tests" (referred to here as "switchback" tests per TPU) to compare space heating, temperature, and RH in zonal ER heating mode with a DHP/ER mode as discussed in the Building America Test Plan (Lubliner 2010a). (5) Cost data from HFH and other sources related to building efficiency measures focusing on the DHP/ER hybrid heating system. (6) An evaluation of the thermal performance and cost benefit of DHP/ER hybrid heating systems in these high-performance homes employing life cycle cost analysis for energy code policy and monthly cash flow analysis of HFH homeowners. (7) Post-monitoring occupant survey results. The report also provides the following stakeholder findings and recommendations: (1) DHP single-head systems at The Woods are cost-effective to new homebuyers of these high-performance all-electric homes. (2) Stakeholder education is needed on design, inspection, and commissioning; documentation is needed for heat recovery ventilation (HRV) and from ENERGY STAR builders, verifiers, and inspectors to help ensure that the houses meet the goal of "build tight, ventilate right." (3) A code gap in inspection and enforcement was identified that should be addressed by: (3a) Improving the fire marshal's approach to sprinkler attic piping freeze protection; (3b) Improving the maintenance of ceiling insulation continuity; and (3c) Educating the local building inspector on attic insulation inspection concerns that allow for maximizing design improveme...

affordable housing↗

A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging

A fiber/solid-state hybrid seeded regenerative amplifier, capable of achieving high output energy with tunable pulse widths, has been developed for satellite laser ranging applications. The regenerative amplifier cavity uses a pair of Nd:YAG zigzag slabs oriented orthogonally to one another in order to make thermal lensing effects symmetrical and simplify optical correction schemes. The seed laser used is a fiber-coupled 1,064-nm narrowband (<0.02 nm) diode laser that is discretely driven in a new short-pulsed mode, enabling continuously tunable seed pulse widths in the 0.2-to-0.4-ns range. The amplifier gain unit consists of a pair of Brewster-cut 6-bounce zigzag Nd:YAG laser slabs, oriented 90deg relative to each other in the amplifier head. This arrangement creates a net-symmetrical thermal lens effect (an opposing singleaxis effect in each slab), and makes thermo-optical corrections simple by optimizing the curvature of the nearest cavity mirror. Each slab is pumped by a single 120-W, pulsed 808-nm laser diode array. In this configuration, the average pump beam distribution in the slabs had a 1-D Gaussian shape, which matches the estimated cavity mode size. A half-wave plate between the slabs reduces losses from Fresnel reflections due to the orthogonal slabs Brewster-cut end faces. Successful "temporal" seeding of the regenerative amplifier cavity results in a cavity Q-switch pulse envelope segmenting into shorter pulses, each having the width of the input seed, and having a uniform temporal separation corresponding to the cavity round-trip time of approx. =10 ns. The pulse energy is allowed to build on successive passes in the regenerative amplifier cavity until a maximum is reached, (when cavity gains and losses are equal), after which the pulse is electro- optically switched out on the next round trip The overall gain of the amplifier is approx. =82 dB (or a factor of 1.26 million). After directing the amplified output through a LBO frequency doubling crystal, approx. = 2.1 W of 532-nm output (>1 mJ) was measured. This corresponds to a nonlinear conversion efficiency of >60%. Furthermore, by pulse pumping this system, a single pulse per laser shot can be created for the SLR (satellite laser ranging) measurement, and this can be ejected into the instrument. This is operated at the precise frequency needed by the measurement, as opposed to commercial short-pulsed, mode-locked systems that need to operate in a continuous fashion, or CW (continuous wave), and create pulses at many MHz. Therefore, this design does not need to throw away or dump 99% of the laser energy to produce what is required; this system can be far smaller, more efficient, cheaper, and readily deployed in the field when packaged efficiently. Finally, by producing custom diode seed pulses electronically, two major advantages over commercial systems are realized: First, this pulse shape is customizable and not affected by the cavity length or gain of the amplifier cavity, and second, it can produce adjustable (selectable) pulse widths by simply adding multiple seed diodes and coupling each into commercial, low-cost fiber-optic combiners.

Coyle, Barry↗

RAPID FORMATION OF SATURN AFTER JUPITER COMPLETION

We have investigated Saturn's core formation at a radial pressure maximum in a protoplanetary disk, which is created by gap opening by Jupiter. A core formed via planetesimal accretion induces the fragmentation of surrounding planetesimals, which generally inhibits further growth of the core by removal of the resulting fragments due to radial drift caused by gas drag. However, the emergence of the pressure maximum halts the drift of the fragments, while their orbital eccentricities and inclinations are efficiently damped by gas drag. As a result, the core of Saturn rapidly grows via accretion of the fragments near the pressure maximum. We have found that in the minimum-mass solar nebula, kilometer-sized planetesimals can produce a core exceeding 10 Earth masses within two million years. Since Jupiter may not have undergone significant type II inward migration, it is likely that Jupiter's formation was completed when the local disk mass has already decayed to a value comparable to or less than Jovian mass. The expected rapid growth of Saturn's core on a timescale comparable to or shorter than the observationally inferred disk lifetime enables Saturn to acquire the current amount of envelope gas before the disk gas is completely depleted. The high heat energy release rate onto the core surface due to the rapid accretion of the fragments delays onset of runaway gas accretion until the core mass becomes somewhat larger than that of Jupiter, which is consistent with the estimate based on interior modeling. Therefore, the rapid formation of Saturn induced by gap opening of Jupiter can account for the formation of multiple gas giants (Jupiter and Saturn) without significant inward migration and larger core mass of Saturn than that of Jupiter.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AGB stars and presolar grains

Among presolar materials recovered in meteorites, abundant SiC and Al{sub 2}O{sub 3} grains of AGB origins were found. They showed records of C, N, O, {sup 26}Al and s-element isotopic ratios that proved invaluable in constraining the nucleosynthesis models for AGB stars [1, 2]. In particular, when these ratios are measured in SiC grains, they clearly reveal their prevalent origin in cool AGB circumstellar envelopes and provide information on both the local physics and the conditions at the nucleosynthesis site (the H- and He-burning layers deep inside the structure). Among the properties ascertained for the main part of the SiC data (the so-called mainstream ones), we mention a large range of {sup 14}N/{sup 15}N ratios, extending below the solar value [3], and {sup 12}C/{sup 13}C ratios ≳ 30. Other classes of grains, instead, display low carbon isotopic ratios (≳ 10) and a huge dispersion for N isotopes, with cases of large {sup 15}N excess. In the same grains, isotopes currently feeded by slow neutron captures reveal the characteristic pattern expected from this process at an efficiency slightly lower than necessary to explain the solar main s-process component. Complementary constraints can be found in oxide grains, especially Al{sub 2}O{sub 3} crystals. Here, the oxygen isotopes and the content in {sup 26}Al are of a special importance for clarifying the partial mixing processes that are known to affect evolved low-mass stars. Successes in modeling the data, as well as problems in explaining some of the mentioned isotopic ratios through current nucleosynthesis models are briefly outlined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

This report provides an assessment as to whether new buildings constructed to the commercial energy-efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The purpose of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Kinematic arguments against single relativistic shell models for GRBs

Two main types of models have been suggested to explain the long durations and multiple peaks of Gamma Ray Bursts (GRBs). In one, there is a very quick release of energy at a central site resulting in a single relativistic shell that produces peaks in the time history through its interactions with the ambient material. In the other, the central site sporadically releases energy over hundreds of seconds forming a peak with each burst of energy. The authors show that the average envelope of emission and the presence of gaps in GRBs are inconsistent with a single relativistic shell. They estimate that the maximum fraction of a single shell that can produce gamma-rays in a GRB with multiple peaks is 10(exp (minus)3), implying that single relativistic shells require 10(exp 3) times more energy than previously thought. They conclude that either the central site of a GRB must produce (approx)10(exp 51) erg/s(exp (minus)1) for hundreds of seconds, or the relativistic shell must have structure on a scales the order of (radical)(epsilon)(Gamma)(exp (minus)1), where (Gamma) is the bulk Lorentz factor ((approximately)10(exp 2) to 10(exp 3)) and (epsilon) is the efficiency.

Fenimore, Edward E.↗

VUV Photoionization Study of the Formation of the Simplest Polycyclic Aromatic Hydrocarbon: Naphthalene (C 10 H 8 )

The formation of the simplest polycyclic aromatic hydrocarbon (PAH), naphthalene (C 10 H 8 ), was explored in a high-temperature chemical reactor under combustion-like conditions in the phenyl (C 6 H 5 )-vinylacetylene (C 4 H 4 ) system. The products were probed utilizing tunable vacuum ultraviolet light by scanning the photoionization efficiency (PIE) curve at a mass-to-charge m/z = 128 (C 10 H 8 + ) of molecules entrained in a molecular beam. The data fitting with PIE reference curves of naphthalene, 4-phenylvinylacetylene (C 6 H 5 CCC 2 H 3 ), and trans -1-phenylvinylacetylene (C 6 H 5 CHCHCCH) indicates that the isomers were generated with branching ratios of 43.5±9.0: 6.5±1.0: 50.0±10.0%. Kinetics simulations agree nicely with the experimental findings with naphthalene synthesized via the hydrogen abstraction-vinylacetylene addition (HAVA) pathway and through hydrogen-assisted isomerization of phenylvinylacetylenes. In conclusion, the HAVA route to naphthalene at elevated temperatures represents an alternative pathway to the hydrogen abstraction-acetylene addition (HACA) forming naphthalene in flames and circumstellar envelopes, whereas in cold molecular clouds, HAVA synthesizes naphthalene via a barrierless bimolecular route.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A wave-based model for cross-beam energy transfer in direct-drive inertial confinement fusion

Cross-beam energy transfer (CBET) is thought to be responsible for a 30% reduction in hydrodynamic coupling efficiency on OMEGA and up to 50% at the ignition scale for direct-drive (DD) implosions. These numbers are determined by ray-based models that have been developed and integrated within the radiation–hydrodynamics codes LILAC (1-D) and DRACO (2-D). However, ray-based modeling of CBET in an inhomogeneous plasma assumes a steady-state plasma response, does not include the effects of beam speckle, and treats ray caustics in an ad hoc manner. The validity of the modeling for ignition-scale implosions has not yet been determined. To address the physics shortcomings, which have important implications for DD inertial confinement fusion, a new wave-based model has been developed. It solves the time-enveloped Maxwell equations in three dimensions, including polarization effects, plasma inhomogeneity, and open-boundary conditions with the ability to prescribe beams incident at arbitrary angles. Beams can be made realistic with respect to laser speckle, polarization smoothing, and laser bandwidth. This, coupled to a linearized low-frequency plasma response that does not assume a steady state, represents the most-complete model of CBET to date.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Duct Insulation and Sealing Requirements in Commercial Buildings - Code Notes

Duct insulation and sealing, especially insulated supply ducts delivering conditioned air within a building, save energy. The intent of energy-efficiency codes, as related to duct insulation and sealing, is to keep mechanically warmed or cooled air as close to a constant, desired temperature as possible and prevent the conditioned air from escaping the duct system while it is being moved to spaces where it is needed. If reduced heat transfer through insulated ducts is accounted for in the heating, ventilating, and air conditioning (HVAC) load calculations, it may even be possible to reduce the size of HVAC equipment.

Duct systems, thermal envelope, conditioned air, H↗

Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders - Chicago, IL and Devens, MA

TO4 Task 3.1 - K Hovnanian Chicago, IL DOE Challenge Home Program Certified Home Constructed and Verified Specifications DOE Challenge Home Building envelope Ceiling R-49 blown fiberglass, Grade I Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I and 1"" R-5 extruded polystyrene (XPS) insulating sheathing Frame Floors R-38 blown fiberglass, Grade I Basement Walls R-19 fiberglass batts draped full height, Grade I Basement Slab uninsulated Windows Above Grade: ENERGY STAR certified, U=0.29, SHGC=0.28 Basement: Non ENERGY STAR certified, U=0.29, SHGC=0.24 Infiltration 2 ACH 50 Mechanical systems Heat 95% AFUE sealed combustion natural gas furnace in conditioned space Goodman GMH950703BXAF Cooling 13 SEER split system Goodman GSX130301BC DHW AO Smith Vertex 100 0.96 EF natural gas tank water heater in 2nd floor utility closet Hot Water Distribution Redesigned trunk and branch Compliant with EPA WaterSense Efficient Distribution Requirements Ducts Located 100% in conditioned space via floor joists leak free to outside (5% or less) Ventilation Central Fan Integrated Supply (CFIS) ventilation with 6"" insulated outside air duct Fan Controller: Air Cycler FRV, with 6"" motorized damper 50 CFM outside air flow, 33% duty cycle (10 minutes on, 20 minutes off); ASHRAE 62.2-2010 compliance via an exhaust fan - Panasonic FV-08VQ5 WhisperCeiling Rerturn Pathways Active Return at Master Bedroom Transfer Grilles in Secondary Bedrooms Appliances, Lighting, MELs Lights 80% ENERGY STAR certified CFL Appliances ENERGY STAR certified refrigerator, dishwasher, and clothes washer; Natural gas range/oven and clothes dryer" STRUCTURE - Test House Lot 145 - 2013 DOE Challenge Test House Task 3.1 Bolingbrook, IL 60490 House is constructed and is DOE Challenge Verified by Don Nelson, a local rater. The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America Program goals, specifically compliance with the DOE Challenge Home Program. To that end, Building Science Corporation (BSC) consulted on the construction of five test houses by three cold climate production builders in three separate U.S. cities. (1) K. Hovnanian Homes, Chicago, Illinois (2) David Weekley Homes, Denver, Colorado (3) Transformations, Inc., Devens, Massachusetts. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive or performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations about the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: (1) Adding services to the scope of work for various trades, such as HERS Rater and heating, ventilation, and air conditioning contractor. (2) Increased material costs related to the checklists, especially the U.S. Environmental Protection Agency Indoor airPLUS and WaterSense Efficient Hot Water Distribution requirement. Ceiling - 18" cellulose Walls - 12" open cell spray foam in double stud walls Foundation - R-10 under slab, 3 1/2" closed-cell spray foam at walls Windows - Harvey U=0.20, SHGC=0.22 Infiltration - 1.0 sq in per 100 sq ft Heating - Mini split heat pump, 10.6 HSPF, 23 SEER Cooling - Mini split heat pump, 10.6 HSPF, 23 SEER DHW - 0.97 EF instantaneous propane water heater Ventilation - bathroom exhaust fans as basic option, HRV upgrade option Adams Circle Devens MA 01434 Cavite Street Devens, MA 01434

Array↗

Report of the Panel on Aerodynamics

Progress in aerodynamics over the past 50 years has been evidenced by the development of increasingly sophisticated and efficient flight vehicles throughout the flight spectrum. Advances have generally arisen in an evolutionary manner from experience gained in wind tunnel testing, flight testing, and improvements in analytical and computational capabilities. As a result of this evolutionary development, both military and commercial vehicles operate at a relatively high efficiency level. This observation plus the fact that airplanes have not changed appreciably in outward appearance over recent years has led some skeptics to conclude incorrectly that aerodynamics is a mature technology, with little to be gained from further developments in the field. It is of interest to note that progress in aerodynamics has occurred without a thorough understanding of the fundamental physics of flow, turbulence, vortex dynamics, and separated flow, for example. The present understanding of transition, turbulence, and boundary layer separation is actually very limited. However, these fundamental flow phenomena provide the key to reducing the viscous drag of aircraft. Drag reduction provides the greatest potential for increased flight efficiency from the standpoint of both saving energy and maximizing performance. Recent advances have led to innovative concepts for reducing turbulent friction drag by modifying the turbulent structure within the boundary layer. Further advances in this basic area should lead to methods for reducing skin friction drag significantly. The current challenges for military aircraft open entirely new fields of investigation for the aerodynamicist. The ability through very high speed information processing technology to totally integrate the flight and propulsion controls can permit an aircraft to fly with "complete abandon," avoiding departure, buffet, and other undesirable characteristics. To utilize these new control concepts, complex aerodynamic phenomena will have to be understood, predicted, and controlled. Current requirements for military aircraft include configuration optimization through a widened envelope from subsonic to supersonic and from low to high angles of attack. This task is further complicated by requirements for control of observables. These challenging new designs do not have the luxury of a large experimental data base from which to optimize for various parameter combinations. Consequently, there exists a strong need for better techniques, both experimental and computational, to permit design optimization in a complete sense.

Bradley, Richard G.↗

Modern Radar Techniques for Geophysical Applications: Two Examples

The last decade of the evolution of radar was heavily influenced by the rapid increase in the information processing capabilities. Advances in solid state radio HF devices, digital technology, computing architectures and software offered the designers to develop very efficient radars. In designing modern radars the emphasis goes towards the simplification of the system hardware, reduction of overall power, which is compensated by coding and real time signal processing techniques. Radars are commonly employed in geophysical radio soundings like probing the ionosphere; stratosphere-mesosphere measurement, weather forecast, GPR and radio-glaciology etc. In the laboratorio di Geofisica Ambientale of the Istituto Nazionale di Geofisica e Vulcanologia (INGV), Rome, Italy, we developed two pulse compression radars. The first is a HF radar called AIS-INGV; Advanced Ionospheric Sounder designed both for the purpose of research and for routine service of the HF radio wave propagation forecast. The second is a VHF radar called GLACIORADAR, which will be substituting the high power envelope radar used by the Italian Glaciological group. This will be employed in studying the sub glacial structures of Antarctica, giving information about layering, the bed rock and sub glacial lakes if present. These are low power radars, which heavily rely on advanced hardware and powerful real time signal processing. Additional information is included in the original extended abstract.

Arokiasamy, B. J.↗