Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical distribution grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Disaggregating Future Retail Electricity Rate Growth [Slides]

Recent Berkeley Lab research found that modest retail rate increases over the past 10 years were mostly driven by large increases in capital expenditures (CapEx) that were offset in part by substantial wholesale price reductions. Decision-makers are increasingly concerned about the potential future rate impacts of a number of policies and industry trends that support rapid decarbonization, electrification, and grid modernization. Using historical FERC Form 1 data and the existing literature on policies and industry trends that are likely to affect utility-incurred costs and retail sales, Berkeley Lab researchers developed ranges of forecasted growth rates for cost-related rate drivers (i.e., fuel and purchased power; transmission, distribution, generation, and other categories of both non-fuel operations & maintenance and CapEx) and non-cost related rate drivers (i.e., retail sales, peak demand, and customers). These were then used as inputs to a pro-forma utility financial model (FINDER) that estimated the growth in retail electric rates between 2020 and 2030 for a prototypical vertically-integrated investor-owned utility in the United States. The analysis produced the following results: 1. Assuming average growth rates in all rate drivers, future retail rate growth is driven by sizable increases in all CapEx costs, where fuel and purchased power costs are replaced by generation CapEx as the largest rate component between 2020 and 2030. 2. Growth in sales/peak demand/customers, generation CapEx costs, and fuel and purchased power (FPP) costs, in isolation, produce the most uncertainty in rate growth. Specifically, a 1% increase in the compound annual growth rate (CAGR) of retail sales, coincident peak demand (CP), and customers (Sales-CP-Cust) results in a 0.88-0.93% decrease in the CAGR of rates, in isolation. However, a 1% increase in the CAGR of generation CapEx budgets results in a 0.07-0.14% increase in the CAGR of rates, while a 1% increase in the CAGR of FPP costs causes a 0.10-0.14% increase in the CAGR of rates, all else being equal. 3. Taking into account the correlation and variability of the growth in all rate drivers jointly, generation CapEx is expected to be both the largest and most uncertain rate component by 2030 (20-25% share of the retail rate). Transmission and distribution CapEx, along with fuel and purchased power costs are each expected to comprise between 12% and 17% of retail rates.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reese Housing Power Project (Final Technical Report)

The Reese Housing Power Project is located on Tribal trust land in Colusa, CA and expands existing medium-voltage distribution to seven new households with the addition of medium-voltage cabling, step down transformers, smart meters, and street lighting for the new development. The Tribe utilized their existing Co-Generation power plant and micro grid to supply the new homes with highly reliable power with fewer interruptions and at a reduced rate compared with the local utility. The project gives the Tribe greater independence from traditional power sources and provides jobs for the community. The project reduces electric energy costs, increases Tribe self-reliance, and provides highly reliable electric power to seven tribal members’ homes. Construction of the project also provided jobs for the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interoperable, Inverter - Based Distributed Energy Resources Enable 100% Renewable and Resilient Utility Microgrids

As microgrids transition away from use of conventional generating resources and increasingly rely on renewable resources towards decarbonization goals, it is crucial to evaluate the capability inverter-based resources to provide microgrid stability and resilience. Particularly, microgrids with a high contribution of intermittent solar photo voltaic generation and higher load variability present unique challenges requiring fast voltage and frequency support. At the San Diego Gas & Electric Company(R) (SDG&E(R)) Borrego Springs Microgrid, a battery inverter was upgraded with grid-forming (GFM) capability to serve as island leader, transitioning responsibility away from diesel generators. An interoperable microgrid control scheme was developed, coordinating GFM and grid-following (GFL) inverters. Hardware-in-the-loop (HIL) simulations using relevant power and controller HIL interfaces between real-time simulators and field equipment are being conducted to de-risk field deployment.

battery energy storage↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

What Role Do Aggregators Play in Power System Security and Resilience?

Barriers to the participation of distributed energy resources (DERs) in wholesale electricity markets have limited the use of DERs for power system security and resilience. In September 2020, the Federal Energy Regulatory Commission (FERC) approved an order to reduce these barriers. FERC Order No. 2222 enables the participation of DER aggregators in wholesale electricity markets. DERs include renewable generation and technologies that support the integration of renewable generation by increasing grid flexibility and resilience. Requiring wholesale energy markets to allow DER aggregator participation provides a path for DERs to become competitive in these markets. As the contribution from aggregated DERs continues to increase, the aggregator's role in supporting grid security and resilience will become more critical. This paper reviews work that demonstrates how DER aggregators can provide resilience support through technical capabilities, operational strategies, and secure communication architectures. Socioeconomic influences and impacts of aggregators, including implications for social resilience, are presented. In surveying the current state-of-the-art across different but interconnected topics, we illustrate how aggregators can be power system participants that enhance grid security. There is no one-size-fits-all approach to enhancing resilience in a power grid that includes a growing cohort of DER aggregators, but there are many options for aggregators to contribute to a more resilient and secure power grid.

aggregator↗

Machine Learning Derived Dynamic Operating Reserve Requirements in High-Renewable Power Systems

Accurately forecasting wind and solar power output poses challenges for deeply decarbonized electricity systems. Grid operators must commit resources to provide reserves to ensure reliable operations in the face of forecast errors, a process which can increase fuel consumption and emissions. We apply neural network-based machine learning to expand the usefulness of median point forecast data by creating probabilistic distributions of short-term uncertainty in demand, wind, and solar forecasts that adapt to prevailing grid conditions. Machine learning derived estimates of forecast errors compare favorably to estimates based on incumbent methods. Reserves derived from machine learning are usually smaller than values derived using incumbent methods, which enables fuel savings during most hours. Machine learning reserves are generally larger than incumbent reserves during times of higher forecast error, potentially improving system reliability. Performance is tested using multi-stage production simulation modeling of the California Independent System Operator (CAISO) system. Machine learning reserves provide production cost and greenhouse gas (GHG) emission reductions of approximately 0.3% relative to historical 2019 requirements. Savings in the 2030 timeframe are highly dependent on battery storage capacity. At lower levels of battery capacity, savings of 0.4% from machine learning reserves are shown. Significant quantities of battery storage are expected to be added to meet California's resource adequacy needs and GHG reduction targets. Addition of these batteries saturate reserve needs and results in minimal within-hour balancing costs in 2030.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Performance Solution for Security Constrained Optimal Power Flow

Solving the Alternating Current Optimal Power Flow (ACOPF) problem is key to economically efficient and reliable power networks with a good solution potentially saving utilities tens of billions of dollars annually (according to FERC). The Grid Optimization (GO) Competition set up by ARPA-E saw several promising solutions in Challenge 1. While team GOT-TJU-OPF placed top 10 in Division 3 and 4, this was not a satisfactory performance, and the team has identified specific areas to improve and will be adding more members to round out the necessary skills and expertise needed to be more competitive. The team set out for redemption during GO Challenge 2 with an improved High-Performance Solution for Security Constrained Optimal Power Flow. The (renamed) BSI-GOT-OPF Team ended up finishing top 2 overall in the competition. The algorithms developed have potential impacts for the electric power markets that are enormous. Optimal Power Flow technology can be an enabling technology to achieve energy-efficient power grids while enhancing renewable energy penetration, among others.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CITRC Cable Info

Working on a DOE project with university sub-contractors to build power grid simulations. We need the cable size and spacing to build accurate models. Other related documents on the physical set up and electrical components have been released, INL/MIS-20-59900 and INL/MIS-20-60003.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Kickstart Your Federal Microgrid Resiliency Project: Financing Opportunities and Best Practices

Recent high-impact events such as hurricanes and wildfires have resulted in the loss of utility grid power to federal sites, highlighting the need for energy system resilience. To sustain critical functions, site loads may need to operate during an electric grid outage or at least have power restored quickly after the event. A microgrid can provide reliable backup power to critical loads when electric utility power is interrupted, and may also provide value during normal operations.

DER↗

Feasibility Study of Real-Time Carbon Emission Responsive Electric Vehicle Charging Control in Buildings: Preprint

With the progressing electrification of the transportation sector, the source of carbon emissions is gradually shifting from fossil fuel to grid electricity because of electric vehicles (EVs). The carbon intensity of the grid can fluctuate significantly within hours due to the time-varying power generation mix. Therefore, shifting EV charging loads to cleaner hours in response to the carbon intensity signals can reduce carbon emissions. Existing EV charging control methods typically consider the electricity price or the available generation by distributed energy resources (e.g., photovoltaics) to inform decision-making. Such methods tend to reduce energy costs but may neglect the environmental impact of EV charging activities. We propose and compare four carbon emission responsive EV charging controllers with various control rules. The proposed controllers are evaluated based on simulation experiments using metrics such as carbon emission reduction potential, state of charge (SOC) at departure, and peak demand. We found that the need of EV owners to have full batteries at departure could lead to an emission increase when the curtailed EV charge was compensated before departure. Further, up to 12.7% of carbon emission reduction can be achieved if the EV owners reduce the target SOC at departure by less than 15%.

carbon emission↗

CEEP (Cyber-Energy Emulation Platform) [SWR-20-102]

NREL's Cyber-Energy Emulation Platform (CEEP) provides the capability to realize cyber-energy security and resilience through automation and orchestration of virtualized systems and software defined networks for the electric grid. CEEP enables testing and validation of grid-security and -control methodologies as the grid evolves to include smart technologies/systems, such as virtualization and containerization of grid components, software defined networking, simulation and co-simulation frameworks, and hardware in the loop. CEEP is a modular system that can be distributed and deployed across different hardware infrastructure sizes and network architectures. For example, CEEP can visualize, emulate, and/or coordinate the Smart-Grid Network Visualization, Intrusion Detection, and Network Healing system. Using CEEP, intrusion-detection and network-self-healing solutions can be deployed at grid control centers, within secure private clouds, and in cyber-energy appliances.

Vaughan, Evan↗

Cyber Energy Emulation Platform (CEEP) [SWR-20-102]

NREL's Cyber-Energy Emulation Platform (CEEP) provides the capability to realize cyber-energy security and resilience through automation and orchestration of virtualized systems and software defined networks for the electric grid. CEEP enables testing and validation of grid-security and -control methodologies as the grid evolves to include smart technologies/systems, such as virtualization and containerization of grid components, software defined networking, simulation and co-simulation frameworks, and hardware in the loop. CEEP is a modular system that can be distributed and deployed across different hardware infrastructure sizes and network architectures. For example, CEEP can visualize, emulate, and/or coordinate the Smart-Grid Network Visualization, Intrusion Detection, and Network Healing system. Using CEEP, intrusion-detection and network-self-healing solutions can be deployed at grid control centers, within secure private clouds, and in cyber-energy appliances.

Rivera, Joshua↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of the effects of external current systems on the MAGSAT data utilizing grid cell modeling techniques

The feasibility of modeling magnetic fields due to certain electrical currents flowing in the Earth's ionosphere and magnetosphere was studied. Initial efforts were devoted to reading MAGSAT data tapes in preparation for further analysis of the MAGSAT data. Further efforts concern a modeling procedure developed to compute the magnetic field at satellite orbit due to hypothesized current distributions in the ionosphere and magnetosphere. This technique utilizes a linear current element representation of the large scale space current system.

Klumpar, D. M.↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗