Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrically”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Design Study of Double-Sided Axial-Flux Magnetically Geared Motors for Electric Aircraft Applications

Electric aircraft require advances in electric motor drivetrain efficiency, specific power, and reliability. In terms of mass and efficiency, mechanically geared electric motor drivetrains will significantly outperform direct drive electric motor drive trains in most applications. Mechanical gears however have numerous wear and failure modes that can result in increased maintenance and reliability penalties for an aircraft. Magnetic gears are being explored by NASA as a potential alternative to mechanical gears for electric aircraft applications. Magnetic gears have none of the surface contact related wear and failure modes of mechanical gears. Therefore, they potentially pose a high reliability alternative to mechanical gears. Magnetic gears can also share magnetic components with an electric motor in a magnetically geared drivetrain to achieve significant weight savings. In this paper, one possible topology of magnetically geared motor, the double-sided axial flux magnetically geared motor, is studied to quantify its achievable performance. Design study results suggest that the topology can achieve greater than 20 Nm/kg and 97% efficiency at a 100 kW output power.

Magnetic gears↗

Solid-state Architecture Batteries for Enhanced Rechargeability and Safety (SABERS) Beyond Li-Ion: Technology to Enable Sustainable Electric Aviation

All-electric and hybrid electric aerovehicle concepts face numerous technical barriers prior to their introduction into the consumer marketplace in order to meet sustainable aviation goals. One of the primary barriers to overcome is developing an energy dense storage system capable of meeting the rigorous aerospace safety and performance criteria. Additionally, the electric aviation market requires that the batteries be fabricated in a sustainable manner with materials that are readily available and abundant within the U.S. to ensure there are no supply chain issues during manufacturing. The performance metrics to enable electric aviation are at least two times greater than those of electric ground vehicles. Furthermore, inherently non-flammable batteries are essential for safe operation of commercial electric aerovehicles. The SABERS concept proposes a battery that meets the key performance criteria through development of a solid-state architecture battery utilizing high-capacity sulfur-selenium cathode and lithium metal anode. The combination of sulfur and selenium offers a balanced energy-to-power density ratio, which can be tailored to the specific application by altering the stoichiometric ratios of sulfur to selenium. The hybrid cathode has been developed by implementing NASA patented holey graphene technology as a highly conductive, ultra-lightweight electrode scaffold. A solid-state electrolyte has been used as a safe, non-flammable replacement to the highly flammable liquid organic electrolytes currently used in SOA lithium-ion batteries. This solid-state lithium-sulfur/selenium cell will be designed into a serial stacking configuration to enable dense packaging of the battery cells. The serial stacking configuration is termed a bipolar stack, which has the advantages of reducing overall cell weight, simplifying the interfaced connections for the cell, and minimizing the cooling requirements. Lastly, optimization of battery components will occur through a robust and rigorous combination of various computational modeling techniques covering multiple length scales. The expected result will be a fully solid-state battery with operational temperatures up to 150 °C which provides the required energy density, discharge rates, and inherent safety to meet the strict aerospace mission performance criteria. This poster summarizes recent results from battery component optimization to scale-up production of full SABERS pouch cells.

Urban Air Mobility (UAM) Vehicles↗

Analysis of Hybrid Electric Aircraft Operations in the National Airspace System

This paper investigates the fuel burn and flight time impacts of hybrid electric aircraft operating in the National Airspace System. Future scenarios with hybrid electric flights and the same passenger travel capacity between city pairs as a baseline scenario, taken from historical data, were created. Aircraft that serviced select flights in the baseline scenario were replaced with hybrid electric aircraft based on the flight’s range and seat capacity. Additional hybrid electric flights were added to future scenarios when necessary to keep the future scenario passenger capacity equal or greater to that of the baseline scenario. The baseline and future scenarios were simulated in the NAS Digital Twin, a live, virtual, and constructive environment for building and executing simulations of the Nation Airspace System. Results showed that the future scenarios with hybrid electric flights saved fuel burn, but increased flight time. In the future scenarios, the additional hybrid electric flights did not cause any airports to exceed their operational capacity.

Simulation↗

Operating Hybrid Electric Aircraft in the National Airspace System

This paper investigates the fuel burn and flight time impacts of hybrid electric aircraft operating in the National Airspace System. Future scenarios with hybrid electric flights and the same passenger travel capacity between city pairs as a baseline scenario, taken from historical data, were created. Aircraft that serviced select flights in the baseline scenario were replaced with hybrid electric aircraft based on the flight’s range and seat capacity. Additional hybrid electric flights were added to future scenarios when necessary to keep the future scenario passenger capacity equal or greater to that of the baseline scenario. The baseline and future scenarios were simulated in the NAS Digital Twin, a live, virtual, and constructive environment for building and executing simulations of the Nation Airspace System. Results showed that the future scenarios with hybrid electric flights saved fuel burn, but increased flight time. In the future scenarios, the additional hybrid electric flights did not cause any airports to exceed their operational capacity.

hybrid electric aircraft↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (MEME-CCS)

This effort employs and adapts a rigorous multiscale electricity modeling platform at the National Renewable Energy Laboratory (NREL) to evaluate carbon capture and sequestration (CCS) and negative emissions technologies (NET) from the ARPA-E FLECCS program. NREL's modeling platform includes the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model, which projects future electricity generation mixes at sub-state-level resolution that are downscaled to the unit-level to enable hourly, zonal or nodal electricity production cost modeling in the PLEXOS model. The ReEDS-PLEXOS modeling suite is well-established for examining electric sector futures with high renewable energy penetrations, energy storage, electrification, and distributed generation. The key advancement proposed herein utilizes collaboration with CCS experts at the University of Wyoming (U.WY) and the FLECCS technology development teams to create innovative methods for representing CCS and NET in the ReEDS and PLEXOS models. Expanded technology options and new operational parameterizations are integrated into these models to allow an unprecedented combination of scope and resolution for exploring the future of CCS and NET. The resulting capabilities permit wide-ranging scenario analysis to assess CCS and NET deployment under alternative scenarios of CO2 prices and competitiveness of flexible CCS and NET technologies. We demonstrate sample deployment and operational outcomes to show how these models are being used to assess the future potential for FLECCS technologies and their impacts on the U.S. electricity system. These products will help an emerging CCS/NET industry in the United States by providing economics-driven guidance to technology developers while informing policy and investment decisions in the public and private sectors.

capacity expansion↗

ELECTRIC FIELD-ASSISTED DIFFUSION WELDING TO FABRICATE ALLOY 617 COMPACT HEAT EXCHANGERS

Compact heat exchangers are of interest for a number of applications including advanced reactors. Alloy 617 is one of the top candidate materials for the gas-cooled reactor intermediate heat exchanger. Previous endeavors to diffusion weld Alloy 617 utilized hot pressing (HP). It was reported that grain boundary migration across the interface was hindered by extensive precipitation. Bonds of this nature have been observed to reduce the elevated-temperature mechanical properties compared to the wrought-product form. It was hypothesized that the electric current applied during electric-field-assisted sintering (EFAS) can overcome these challenges, resulting in improved diffusion welding (DW). This study investigated DW of Alloy 617 via EFAS. Stacks composed of three sheets that were 20 mm in diameter were welded using EFAS. Specimens were welded with an applied electric current, a pressure of 30 MPa, hold time of 30 min, and temperatures of 1050°C, 1100°C, and 1150°C. DW using HP as the zero-current analog of EFAS was also performed at the most promising EFAS conditions. Results revealed that both the applied electric current and temperature played a key role in precipitation and grain boundary migration in diffusion-welded Alloy 617. Precipitates were observed at the interface of the hot-pressed samples which limited grain boundary migration. Electric current was found to prevent precipitate formation along the interface at 1150°C. The electric current coupled with a temperature of 1150°C during EFAS resulted in significant grain boundary migration across the interface.

36 - MATERIALS SCIENCE↗

Effects of electric field methods on modeling the midlatitude ionospheric electrodynamics and inner magnetosphere dynamics

Here, we report a self-consistent electric field coupling between the midlatitude ionospheric electrodynamics and inner magnetosphere dynamics represented in a kinetic ring current model. This implementation in the model features another self-consistency in addition to its already existing self-consistent magnetic field coupling with plasma. The model is therefore named as Ring current-Atmosphere interaction Model with Self-Consistent magnetic (B) and electric (E) fields, or RAM-SCB-E. With this new model, we explore, by comparing with previously employed empirical Weimer potential, the impact of using self-consistent electric fields on the modeling of storm time global electric potential distribution, plasma sheet particle injection, and the subauroral polarization streams (SAPS) which heavily rely on the coupled interplay between the inner magnetosphere and midlatitude ionosphere. We find the following phenomena in the self-consistent model: (1) The spatially localized enhancement of electric field is produced within 2.5 < L < 4 during geomagnetic active time in the dusk-premidnight sector, with a similar dynamic penetration as found in statistical observations. (2) The electric potential contours show more substantial skewing toward the postmidnight than the Weimer potential, suggesting the resistance on the particles from directly injecting toward the low-L region. (3) The proton flux indeed indicates that the plasma sheet inner boundary at the dusk-premidnight sector is located further away from the Earth than in the Weimer potential, and a “tongue” of low-energy protons extends eastward toward the dawn, leading to the Harang reversal. (4) SAPS are reproduced in the subauroral region, and their magnitude and latitudinal width are in reasonable agreement with data.

54 ENVIRONMENTAL SCIENCES↗

A Finite Difference Analysis of the Effect of Graphene Additions on the Electrical Conductivity of Polycrystalline Copper

A finite-difference method was used to explore the effect of graphene on the bulk electrical conductivity of copper-graphene composites. In this capacity, grain orientation information from pure copper and copper-graphene composites were used to generate synthetic 3D microstructures. The electrical conductivity of these microstructures were calculated using the finite difference method assuming different average grain sizes. From these calculations, we demonstrate that when high-conductivity grain boundaries are present within the microstructure arising from the presence of graphene, an increase in the bulk electrical conductivity is observed. On the other hand, the difference in textures between copper and copper-graphene composites may not account for a significant difference in bulk electrical conductivity. In comparison, the copper grain size has a considerably larger effect on electrical conductivity as previously anticipated. This is one of the first demonstrations of a physical basis for enhanced conductivity composites and presents pathways for further investigations on the effects of composite microstructural features, material interfaces and graphene content on electrical performance.

Frazier, William E.↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

Hybrid-energy approach enabled by heat storage and oxy-combustion to generate electricity with near-zero or negative CO 2 emissions

We assess a hybrid-energy approach that modifies a steam-turbine power plant to use renewable energy sources (electricity, plus options for geothermal and solar heat), plus fossil fuel (natural gas and coal) and/or waste biomass (e.g., Douglas fir woodchips). Heat storage allows heat to be created during periods of excess energy supply and for that heat to be converted to electricity when demanded. Excess electricity, such as from variable renewable energy (VRE), is used to generate oxygen for oxy-combustion furnaces that create very-hot, high-purity CO 2 that heats granular rock beds in insulated vessels. Cool CO 2 leaving the beds is dried, sent to compressors powered by excess VRE electricity, before being sent by pipeline to geologic CO 2 storage. Very-hot CO 2 transfers high-grade heat from storage to the power plant in a closed loop that returns medium-grade heat back to storage, allowing low- and medium-grade renewable-heat sources to be stacked beneath combustion heat, with all heat sources being converted to electricity at the same (high) thermal efficiency. Reliable, on-demand power may be generated with near-zero CO 2 emissions with fossil fuel and with negative CO 2 emissions with waste biomass. Our analyses show that with fossil fuel, up to 35% of gross power can be derived from renewable sources, while for waste biomass, it can be entirely derived from renewable sources. Because our approach has the potential to ensure that grids have a continuous supply of clean energy and because electricity is only generated once, when demanded, it could serve as an efficient alternative to bulk energy storage.

30 DIRECT ENERGY CONVERSION↗

Exploring sustainable electricity system development pathways in South America’s MERCOSUR sub-region

South America has abundant natural water and energy resources, and exploiting these resources to achieve a clean energy future is central to the continent’s economic and sustainable development objectives for the next several decades. Designing pathways to achieving this clean energy future requires better understanding the structural, techno-economic, and policy forces that may influence the future development of the electricity sector in the region. Here, we focus on an interconnected electricity system of five South American countries – Argentina, Brazil, Chile, Paraguay, and Uruguay – which represent major electricity generation, consumption, and trade dynamics in the region. We explore the implications of various forces that could shape the future composition of the power sector in the sub-region, including: evolving renewable energy cost and performance, natural gas prices, cross-border interconnection facilities, early retirement of installed hydropower, and different decarbonization goals. We use a model framework based on a power system planning platform (GridPath) to co-optimize investment and operations of generation, storage, and transmission facilities out to 2050. Our results in a Reference scenario indicate that the electricity system can maintain a relatively clean energy portfolio by leveraging existing hydropower capacity and integrating increasingly cost-competitive wind and solar power. However, dependence on natural gas in the region is likely to remain high. A low-carbon electricity system can cost-effectively be achieved through policy interventions (e.g., renewable portfolio standards) and by diversifying investments in wind, solar, battery storage, and some new hydropower capacity. We also find that existing hydropower is critical for maintaining reliable future grid operations. Enhanced regional electricity trade, mostly based on existing interconnection capacities with nominal investment in new transmission, can significantly benefit the clean energy transition in the region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reduced de-doping and enhanced electrical conductivity of polyaniline filled phenol-divinylbenzene composite for potential lightning strike protection application

In this study, phenolic resin was mixed with a cross-linking agent divinylbenzene (DVB) to prepare a polyaniline-based electrically-conductive thermosetting polymer composite. It has been shown that this Phenol-DVB mixture can undergo cationic polymerization in the presence of the dodecylbenzene sulfonic acid (DBSA)-doped polyaniline (PANI). Composites with different weight ratios of phenolic resin and DVB were mixed with a fixed weight of DBSA-PANI (i.e. 30 wt. %). Increasing the phenol content in the resin system was found to improve the electrical conductivity of the composite to almost 2700%. This improvement has been assigned to the reduced de-doping of polyaniline in phenol-DVB resin. Active sites of phenol effectively attached to the β carbon of DVB and reduced the proton subtracting species of DVB, leading to reduced de-doping of PANI. This behavior was studied through various characterization techniques including differential scanning calorimetry (DSC), FT-IR spectroscopy and Scanning Electron Microscopy (SEM). Electrical conductivity measurement, mechanical properties, and in-situ electrical conductivity measurements were performed to find the optimized properties of the composite. Optimized composites prepared with the composition of 30 wt. % DBSA-PANI and 70 wt. % of phenol-DVB (50 wt. % each), have shown electrical conductivity of 0.20 S/cm and a flexural modulus of 2.1 GPa, which is a significant improvement in the flexural properties of polymer based-thermosetting composites with similar electrical conductivity. Lastly, this material can be a potential candidate for the lightning strike protection of fiber reinforced plastics.

36 MATERIALS SCIENCE↗

Local Electric Field Effects on Water Dissociation in Bipolar Membranes Studied Using Core–Shell Catalysts

The local electric field strength is thought to affect the rate of water dissociation (WD) in bipolar membranes (BPMs) at the catalyst–nanoparticle surfaces. Here, we study core–shell nanoparticles, where the core is metallic, semiconducting, or insulating, to understand this effect. The nanoparticle cores were coated with a WD catalyst layer (TiO2 or HfO2) via atomic layer deposition (ALD), and the morphology was imaged with transmission electron microscopy. Irrespective of the core material, these core–shell catalysts displayed comparable WD overpotentials at optimal mass loading, despite the hypothesized differences in the electric field strength across the catalyst particle suggested by continuum electrostatic simulations. Substantial atomic interdiffusion between the core and shell was ruled out by X-ray absorption spectroscopy, X-ray photoelectron spectroscopy, and diffuse reflectance optical measurements. However, the optimal mass loading of catalyst was roughly 1 order of magnitude higher for the conductive and high dielectric core materials than for the low dielectric insulating cores. These findings are consistent with the hypothesis that electric field screening within the core material focuses the electric field drop between particles such that larger film thicknesses can be tolerated. Collectively, these data support the idea that it is the local electric field at the molecular level that controls proton-transfer rates and that the metal core/dielectric-shell constructs introduced here modulate that field. Further materials and synthetic design may enable optimization of the electric field strength across the proton-transfer trajectory at the material surface.

Sarma, Prasad V↗

Visualizing Electric and Magnetic Field Coupling in Au-Nanorod Trimer Structures via Stimulated Electron Energy Gain and Cathodoluminescence Spectroscopy: Implications for Meta-Atom Imaging

In this work, trimer meta-atoms composed of three gold rods in an equilateral triangular geometry were fabricated, and their near-field plasmonic responses were characterized via electron energy loss (EEL), cathodoluminescence (CL), and stimulated electron energy loss/gain (sEEL/sEEG) spectroscopy. The trimer structure hybridizes into a low-energy mode with all three rods coupling in-phase, which produces a circulating current and thus a magnetic field. The next highest-energy mode consists of two rods coupling out-of-phase and produces a net electric dipole. We investigate the near fields of hybridized magnetic and electric modes via EEL and CL and correlate their spectral characteristics and intensity maps. Then, by changing the length of the trimer rods, we tune the magnetic and electric modes to our laser energy and characterize the excited state via sEEL/sEEG spectroscopy. Exploration of the tilt dependence, relative to the optical source, of the two modes reveals that the electric mode sEEG intensity increases more than the expected sin 2 (θ) dependence of the optical electric field coupling (see the Supporting Information for a detailed description). After correcting for the tail of the close-proximity electric mode, we demonstrate sEEG via coupling of the magnetic component of the optical field to the magnetic meta-atoms, which has the expected cos 2 (θ) tilt dependence. This realization opens the possibility to explore the nanoscale excited-state near-field imaging of other magnetic meta-atom structures.

36 MATERIALS SCIENCE↗

Imaging electric field dynamics with graphene optoelectronics

The use of electric fields for signalling and control in liquids is widespread, spanning bioelectric activity in cells to electrical manipulation of microstructures in lab-on-a-chip devices. However, an appropriate tool to resolve the spatio-temporal distribution of electric fields over a large dynamic range has yet to be developed. Here we present a label-free method to image local electric fields in real time and under ambient conditions. Our technique combines the unique gate-variable optical transitions of graphene with a critically coupled planar waveguide platform that enables highly sensitive detection of local electric fields with a voltage sensitivity of a few microvolts, a spatial resolution of tens of micrometres and a frequency response over tens of kilohertz. Our imaging platform enables parallel detection of electric fields over a large field of view and can be tailored to broad applications spanning lab-on-a-chip device engineering to analysis of bioelectric phenomena.

59 BASIC BIOLOGICAL SCIENCES↗

Impacts of long-term temperature change and variability on electricity investments

Long-term temperature change and variability are expected to have significant impacts on future electric capacity and investments. This study improves upon past studies by accounting for hourly and monthly dynamics of electricity use, long-term socioeconomic drivers, and interactions of the electric sector with rest of the economy for a comprehensive analysis of temperature change impacts on cooling and heating services and their corresponding impact on electric capacity and investments. Using the United States as an example, here we show that under a scenario consistent with a socioeconomic pathway 2 (SSP2) and representative concentration pathway 8.5 (RCP 8.5), mean temperature changes drive increases in annual electricity demands by 0.5-8% across states in 2100. But more importantly, peak temperature changes drive increases in capital investments by 3-22%. Moreover, temperature-induced capital investments are highly sensitive to both long-term socioeconomic assumptions and spatial heterogeneity of fuel prices and capital stock characteristics, which underscores the importance of a comprehensive approach to inform long-term electric sector planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗