Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrodynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Non-self-adjoint operators as observables in quantum theory and nuclear physics

The aim of this paper is to show the importance and applicability of non-self-adjoint operators for description of observables both in relativistic and nonrelativistic quantum mechanics, as well as in quantum electrodynamics. The paper considers (i) a maximally Hermitian (but non-self-adjoint) time operator in nonrelativistic quantum mechanics and in quantum electrodynamics and (ii) the problem of defining the four-dimensional coordinate and momentum operators describing relativistic particles with zero spin (each of these operators contains both Hermitian and anti-Hermitian parts). Some other applications of non-selfadjoint and non-Hermitian operators in physics are analyzed as well. The paper ends with an analysis of a few cases of T -non-invariant interactions, including quantum dissipation and nuclear optical potentials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

I. The isotopic Foldy-Wouthuysen representation and chiral symmetry

The paper introduces the isotopic Foldy-Wouthuysen representation. This representation was used to derive equations for massive interacting fermion fields. When the interaction Hamiltonian commutes with the matrix γ{sup 5}, these equations possess chiral invariance irrespective of whether fermions have mass or are massless. The isotopic Foldy-Wouthuysen representation preserves the vector and axial currents irrespective of the fermion mass value. In the Dirac representation, the axial current is preserved only for massless fermions. In the isotopic Foldy-Wouthuysen representation, the ground state of fermions (vacuum) turns out to be degenerate, and therefore there is the possibility of spontaneously breaking parity (P — symmetry). This study considers the example of constructing a chirally symmetric quantum electrodynamics framework in the isotopic Foldy-Wouthuysen representation. A number of physical processes are calculated in the lowest orders of the perturbation theory. Final results of the calculations agree with the results of the standard quantum electrodynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2D Bragg Resonators Based on Planar Dielectric Waveguides (from Theory to Model-Based Testing)

Using analytical approaches and CST Microwave Studio 3D simulation, the electrodynamic characteristics of 2D Bragg resonators based on planar dielectric waveguides with doubly periodic corrugation are theoretically analyzed. Such resonators are of great interest to obtain directed narrow-band radiation in heterolasers with large active regions. Model electrodynamic experiments on the “cold” testing of such structures in the millimeter range are performed. Good agreement between the experimental and simulation results is shown, including the existence of the highest-Q mode within the Bragg reflection band in the absence of defects in the periodicity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Possible Way To Describe Breit's Interaction in Solids Composed From Heavy Elements

The report describes a theoretical procedure which could help evaluate the effect of quantum electrodynamic corrections on the electronic structure of crystals consisting of heavy elements. The procedure uses the effective Breit interaction as correction to traditional Coulomb interaction between electrons in non-relativistic theory. A number of other simplifying assumptions were made since even such a simplified consideration of quantum electrodynamic effects in crystals is a great challenge. These are as follows: (1) Exchange and correlation effects from the nonrelativistic interaction (the Coulomb term) between electrons are described within Density Functional Theory (DFT). (2) The Breit correction is on at the phase which involves the calculation of matrix elements between basis functions which define the single-electron spectrum of a crystal. In order to calculate the contribution from the Breit correction, the total wave function of electrons in the crystal is approximated by one Slater determinant consisting of the single-electron DFT-orbitals. (3) Only local matrix elements (i.e., the part of the two-electron integral for which both coordinate arguments belong to one and the same muffin-tin sphere) are considered.

36 MATERIALS SCIENCE↗

Challenges and Considerations When Using Hydraulic Modal Shaking in Large-Scale Modal Testing

As test articles become dimensionally larger, more complex, and massive in weight, combined with the need to excite them to higher than traditional levels in order to identify their nonlinear characteristics, modal shakers that can generate significantly higher force levels, have longer stroke lengths, and possess higher velocity limits are required. While large scale modal tests may be performed with electrodynamic modal shakers, hydraulic modal shakers become attractive since they can generate higher force levels at lower unit cost with a smaller spatial footprint. While test engineers familiar with electrodynamic modal shakers are familiar with the challenges of displacement and velocity limits and the relatively mild shaker nonlinear distortion due to amplifier gains and shaker flexure structural geometric nonlinearities, they probably are not as familiar with the unique set of challenges hydraulic modal shakers present. These unique challenges include significant nonlinear distortion in the shaker force, issues with the setup of the hydraulic power supply and the associated hydraulic hosing, velocity limits as they relate to potentially damaging the hydraulic actuator piston, and safety issues with operating high-pressure hydraulic systems. This paper addresses these unique challenges to help the test engineer to better utilize hydraulic modal shakers on large-scale modal tests.

Distortion↗

Improving low-level plasma protein mass spectrometry-based detection for candidate biomarker discovery and validation

Methods. To improve the detection of low abundance protein candidate biomarker discovery and validation, particularly in complex biological fluids such as blood plasma, increased sensitivity is desired using mass spectrometry (MS)-based instrumentation. A key current limitation on the sensitivity of electrospray ionization (ESI) MS is due to the fact that many sample molecules in solution are never ionized, and the vast majority of the ions that are created are lost during transmission from atmospheric pressure to the low pressure region of the mass analyzer. Two key technologies, multi-nanoelectrospray emitters and the electrodynamic ion funnel have recently been developed and refined at Pacific Northwest National Laboratory (PNNL) to greatly improve the ionization and transmission efficiency of ESI MS based analyses. Multi-emitter based ESI enables the flow from a single source (typically a liquid chromatography [LC] column) to be divided among an array of emitters (Figure 1). The flow rate delivered to each emitter is thus reduced, allowing the well-documented benefits of nanoelectrospray 1 for both sensitivity and quantitation to be realized for higher flow rate separations. To complement the increased ionization efficiency afforded by multi-ESI, tandem electrodynamic ion funnels have also been developed at PNNL, and shown to greatly improve ion transmission efficiency in the ion source interface.2, 3 These technologies have been integrated into a triple quadrupole mass spectrometer for multiple reaction monitoring (MRM) of probable biomarker candidates in blood plasma and show promise for the identification of new species even at low level concentrations.

59 BASIC BIOLOGICAL SCIENCES↗

Photon and graviton mass limits

We review past and current studies of possible long-distance, low-frequency deviations from Maxwell electrodynamics and Einstein gravity. Both have passed through three phases: (1) Testing the inverse-square laws of Newton and Coulomb, (2) Seeking a nonzero value for the rest mass of photon or graviton, and (3) Considering more degrees of freedom, allowing mass while preserving gauge or general-coordinate invariance. For electrodynamics there continues to be no sign of any deviation. Since our previous review the lower limit on the photon Compton wavelength (associated with weakening of electromagnetic fields in vacuum over large distance scale) has improved by four orders of magnitude, to about one astronomical unit. Rapid current progress in astronomical observations makes it likely that there will be further advances. These ultimately could yield a bound exceeding galactic dimensions, as has long been contemplated. Meanwhile, for gravity there have been strong arguments about even the concept of a graviton rest mass. At the same time there are striking observations, commonly labeled 'dark matter' and 'dark energy' that some argue imply modified gravity. This makes the questions for gravity much more interesting. For dark matter, which involves increased attraction at large distances, any explanation by modified gravity would be qualitatively different from graviton mass. Because dark energy is associated with reduced attraction at large distances, it might be explained by a graviton-mass-like effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling subauroral polarization streams during the 17 March 2013 storm

Abstract The subauroral polarization streams (SAPS) are one of the most important features in representing magnetosphere‐ionosphere coupling processes. In this study, we use a state‐of‐the‐art modeling framework that couples an inner magnetospheric ring current model RAM‐SCB with a global MHD model Block‐Adaptive Tree Solar‐wind Roe Upwind Scheme (BATS‐R‐US) and an ionospheric potential solver to study the SAPS that occurred during the 17 March 2013 storm event as well as to assess the modeling capability. Both ionospheric and magnetospheric signatures associated with SAPS are analyzed to understand the spatial and temporal evolution of the electrodynamics in the midlatitude regions. Results show that the model captures the SAPS at subauroral latitudes, where Region 2 field‐aligned currents (FACs) flow down to the ionosphere and the conductance is lower than in the higher‐latitude auroral zone. Comparisons to observations such as FACs observed by Active Magnetosphere and Planetary Electrodynamics Response Experiment (AMPERE), cross‐track ion drift from Defense Meteorological Satellite Program (DMSP), and in situ electric field observations from the Van Allen Probes indicate that the model generally reproduces the global dynamics of the Region 2 FACs, the position of SAPS along the DMSP, and the location of the SAPS electric field around L of 3.0 in the inner magnetosphere near the equator. The model also demonstrates double westward flow channels in the dusk sector (the higher‐latitude auroral convection and the subauroral SAPS) and captures the mechanism of the SAPS. However, the comparison with ion drifts along DMSP trajectories shows an underestimate of the magnitude of the SAPS and the sensitivity to the specific location and time. The comparison of the SAPS electric field with that measured from the Van Allen Probes shows that the simulated SAPS electric field penetrates deeper than in reality, implying that the shielding from the Region 2 FACs in the model is not well represented. Possible solutions in future studies to improve the modeling capability include implementing a self‐consistent ionospheric conductivity module from inner magnetosphere particle precipitation, coupling with the thermosphere‐ionosphere chemical processes, and connecting the ionosphere with the inner magnetosphere by the stronger Region 2 FACs calculated in the inner magnetosphere model.

Yu, Yiqun↗

Spinning black hole scattering at $ \mathcal{O} $(G 3 S 2 )(G 3 S 2 ): Casimir terms, radial action and hidden symmetry

We resolve subtleties in calculating the post-Minksowskian dynamics of binary systems, as a spin expansion, from massive scattering amplitudes of fixed finite spin. In particular, the apparently ambiguous spin Casimir terms can be fully determined from the gradient of the spin-diagonal part of the amplitudes with respect to S 2 = −s(s+1)ħ 2 , using an interpolation between massive amplitudes with different spin representations. From two-loop amplitudes of spin-0 and spin-1 particles minimally coupled to gravity, we extract the spin Casimir terms in the conservative scattering angle between a spinless and a spinning black hole at $ \mathcal{O} $(G 3 S 2 ), finding agreement with known results in the literature. This completes an earlier study [Phys. Rev. Lett. 130 (2023), 021601] that calculated the non-Casimir terms from amplitudes. We also illustrate our methods using a model of spinning bodies in electrodynamics, finding agreement between scattering amplitude predictions and classical predictions in a root-Kerr electromagnetic background up to $ \mathcal{O} $(α 3 S 2 ). For both gravity and electrodynamics, the finite part of the amplitude coincides with the two-body radial action in the aligned spin limit, generalizing the amplitude-action relation beyond the spinless case. Surprisingly, the two-loop amplitude displays a hidden spin-shift symmetry in the probe limit, which was previously observed at one loop. We conjecture that the symmetry holds to all orders in the coupling constant and is a consequence of integrability of Kerr orbits in the probe limit at the first few orders in spin.

Classical Theories of Gravity↗

Exact solutions of (n+1)-dimensional Yang-Mills equations in curved space-time

In the context of a semiclassical approach where vectorial gauge fields can be considered as classical fields, we obtain exact static solutions of the SU(N) Yang-Mills equations in an (n+1)-dimensional curved space-time, for the cases n=1,2,3. As an application of the results obtained for the case n=3, we consider the solutions for the anti-de Sitter and Schwarzschild metrics. We show that these solutions have a confining behavior and can be considered as a first step in the study of the corrections of the spectra of quarkonia in a curved background. Since the solutions that we find in this work are valid also for the group U(1), the case n=2 is a description of the (2+1) electrodynamics in the presence of a point charge. For this case, the solution has a confining behavior and can be considered as an application of the planar electrodynamics in a curved space-time. Finally we find that the solution for the case n=1 is invariant under a parity transformation and has the form of a linear confining solution. - Highlights: Black-Right-Pointing-Pointer We study exact static confining solutions of the SU(N) Yang-Mills equations in an (n+1)-dimensional curved space-time. Black-Right-Pointing-Pointer The solutions found are a first step in the study of the corrections on the spectra of quarkonia in a curved background. Black-Right-Pointing-Pointer A expression for the confinement potential in low dimensionality is found.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗

Ion Funnel Trap Interface for Orthogonal Time-of-Flight Mass Spectrometry

A combined electrodynamic ion funnel and ion trap coupled to an orthogonal acceleration (oa)-time-of-flight mass spectrometer was developed and characterized. The ion trap was incorporated through the use of added terminal electrodynamic ion funnel electrodes enabling control over the axial dc gradient in the trap section. The ion trap operates efficiently at a pressure of ~1 Torr, and measurements indicate a maximum charge capacity of ~3 × 107 charges. An order of magnitude increase in sensitivity was observed in the analysis of low concentration peptides mixtures with orthogonal acceleration (oa)-time-of-flight mass spectrometry (oa-TOF MS) in the trapping mode as compared to the continuous regime. A signal increase in the trapping mode was accompanied by reduction in the chemical background, due to more efficient desolvation of, for example, solvent related clusters. Controlling the ion trap ejection time was found to result in efficient removal of singly charged species and improving signal-to-noise ratio (S/N) for the multiply charged analytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Orthogonal Injection Ion Funnel Interface Providing Enhanced Performance for Selected Reaction Monitoring-Triple Quadrupole Mass Spectrometry

The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher pressure regions (e.g. ion source interfaces) of mass spectrometers, and thus providing increased sensitivity. An “off-axis” ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to charge ratios. In this study a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadruple mass spectrometer was developed and characterized. An orthogonal ion injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at 9-10 Torr pressure. Several critical factors for the HPIF were characterized, including the effects of RF amplitude, DC gradient and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. Lastly, the sensitivity enhancement in liquid chromatography selected reaction monitoring (SRM) analyses of low abundance peptides spiked into a highly complex mixture was also compared with that obtained using a both commercial s-lens interface and a in-line dual ion funnel interface.

47 OTHER INSTRUMENTATION↗

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

Entanglement-enhanced matter-wave interferometry in a high-finesse cavity

An ensemble of atoms can operate as a quantum sensor by placing atoms in a superposition of two different states. Upon measurement of the sensor, each atom is individually projected into one of the two states. Creating quantum correlations between the atoms, that is entangling them, could lead to resolutions surpassing the standard quantum limit set by projections of individual atoms. Large amounts of entanglement involving the internal degrees of freedom of laser-cooled atomic ensembles have been generated in collective cavity quantum-electrodynamics systems, in which many atoms simultaneously interact with a single optical cavity mode. Here we report a matter-wave interferometer in a cavity quantum-electrodynamics system of 700 atoms that are entangled in their external degrees of freedom. In our system, each individual atom falls freely under gravity and simultaneously traverses two paths through space while entangled with the other atoms. In this work, we demonstrate both quantum non-demolition measurements and cavity-mediated spin interactions for generating squeezed momentum states with directly observed sensitivity $3.4^{+1.1}_{–0.9}$dB and $2.5^{+0.6}_{–0.6}$dB below the standard quantum limit, respectively. We successfully inject an entangled state into a Mach–Zehnder light-pulse interferometer with directly observed sensitivity $1.7^{+0.5}_{–0.5}$dB below the standard quantum limit. The combination of particle delocalization and entanglement in our approach may influence developments of enhanced inertial sensors, searches for new physics, particles and fields, future advanced gravitational wave detectors and accessing beyond mean-field quantum many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗

When are Surface Plasmon Polaritons Excited in the Kretschmann-Raether Configuration?

It is widely believed that the reflection minimum in a Kretschmann-Raether experiment results from direct coupling into surface plasmon polariton modes. Our experimental results provide a surprising discrepancy between the leakage radiation patterns of surface plasmon polaritons (SPPs) launched on a layered gold/germanium film compared to the K-R minimum, clearly challenging this belief. We provide definitive evidence that the reflectance dip in K-R experiments does not correlate with excitation of an SPP mode, but rather corresponds to a particular type of perfectly absorbing (PA) mode. Results from rigorous electrodynamics simulations show that the PA mode can only exist under external driving, whereas the SPP can exist in regions free from direct interaction with the driving field. These simulations show that it is possible to indirectly excite propagating SPPs guided by the reflectance minimum in a K-R experiment, but demonstrate the efficiency can be lower by more than a factor of 3. We find that optimal coupling into the SPP can be guided by the square magnitude of the Fresnel transmission amplitude.

Foley IV, Jonathan J.↗

Mode control in an oversized backward wave oscillator

Internal field emission breakdown in the electrodynamic structures of high-power microwave devices can seriously limit the devices' output power and pulse duration. Increasing the diameter of the electrodynamic structure beyond the cutoff radius can reduce these internal fields to levels, which are below critical breakdown levels, but may introduce mode competition as unwanted side effects. An oversized backward wave oscillator with rectangular profile corrugations is designed to produce TM{sub 01} high power microwave radiation without mode competition. The slow wave structure and the reflector are matched to achieve mode selection and enhance interaction efficiency. The physical mechanism for mode selection is explored both in theoretical investigation and particle in cell simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗