Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronics packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

High Temperature Capacitor Development

The absence of high-temperature electronics is an obstacle to the development of untapped energy resources (deep oil, gas and geothermal). US natural gas consumption is projected to grow from 22 trillion cubic feet per year (tcf) in 1999 to 34 tcf in 2020. Cumulatively this is 607 tcf of consumption by 2020, while recoverable reserves using current technology are 177 tcf. A significant portion of this shortfall may be met by tapping deep gas reservoirs. Tapping these reservoirs represents a significant technical challenge. At these depths, temperatures and pressures are very high and may require penetrating very hard rock. Logistics of supporting 6.1 km (20,000 ft) drill strings and the drilling processes are complex and expensive. At these depths up to 50% of the total drilling cost may be in the last 10% of the well depth. Thus, as wells go deeper it is increasingly important that drillers are able to monitor conditions down-hole such as temperature, pressure, heading, etc. Commercial off-the-shelf electronics are not specified to meet these operating conditions. This is due to problems associated with all aspects of the electronics including the resistors and capacitors. With respect to capacitors, increasing temperature often significantly changes capacitance because of the strong temperature dependence of the dielectric constant. Higher temperatures also affect the equivalent series resistance (ESR). High-temperature capacitors usually have low capacitance values because of these dielectric effects and because packages are kept small to prevent mechanical breakage caused by thermal stresses. Electrolytic capacitors do not operate at temperatures above 150oC due to dielectric breakdown. The development of high-temperature capacitors to be used in a high-pressure high-temperature (HPHT) drilling environment was investigated. These capacitors were based on a previously developed high-voltage hybridized capacitor developed at Giner, Inc. in conjunction with a unique high-temperature electrolyte developed during the course of the program. During this program the feasibility of operating a high voltage hybridized capacitor at 230oC was demonstrated. Capacitor specifications were established in conjunction with potential capacitor users. A method to allow for capacitor operation at both ambient and elevated temperatures was demonstrated. The program was terminated prior to moving into Phase II due to a lack of cost-sharing funds.

03 NATURAL GAS↗

Strain Field Analysis in Electronic Components by ESPI: Bad Thermal Contact and Damage Evaluation

Designing electronic components and devices is a complex task that must include also considerations about thermo-mechanical behavior of the component itself. This aspect, in fact, can affect the reliability of the device as a consequence of the thermal stresses that are introduced in the component while it is working. Stress concentration can arise, in fact, due to different thermal expansion coefficients of the materials involved. Determining the thermo-mechanical response by numerically methods is not simple and not always possible so that experimental methods are preferable. In this paper, specifically, the electronic speckle pattern interferometry technique was adopted to measure full-field strain of the component during exercise. By using an optical technique it is possible to get information about the behavior of the component without being in contact with the component itself so that the dissipation coefficient is not altered. The system was able to detect gradients of deformation in the component itself connected to the different distribution of internal current in the component. Moreover, it was observed, that the presence of bad thermal contact between the package and the heat sink can be revealed because it results in a different thermos-mechanical behavior of the component. Finally, a critical defect was introduced in the component and it was observed the way the presence of damage affects the in-plane displacement of the component. Very huge differences were observed leading to the consideration that this kind of approach could be conveniently adopted also as a damage detection tool.

42 ENGINEERING↗

Relativistic decay widths of autoionization processes: The relativistic FanoADC-Stieltjes method

Electronic decay processes of ionized systems are, for example, the Auger decay or the Interatomic/ Intermolecular Coulombic Decay. In both processes, an energetically low lying vacancy is filled by an electron of an energetically higher lying orbital and a secondary electron is instantaneously emitted to the continuum. Whether or not such a process occurs depends both on the energetic accessibility and the corresponding lifetime compared to the lifetime of competing decay mechanisms. We present a realization of the non-relativistically established FanoADC-Stieltjes method for the description of autoionization decay widths including relativistic effects. This procedure, being based on the Algebraic Diagrammatic Construction (ADC), was adapted to the relativistic framework and implemented into the relativistic quantum chemistry program package Dirac. It is, in contrast to other existing relativistic atomic codes, not limited to the description of autoionization lifetimes in spherically symmetric systems, but is instead also applicable to molecules and clusters. We employ this method to the Auger processes following the Kr3d{sup −1}, Xe4d{sup −1}, and Rn5d{sup −1} ionization. Based on the results, we show a pronounced influence of mainly scalar-relativistic effects on the decay widths of autoionization processes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Calculation of the Geometric Factor in a New Experiment Aimed at Studying Radiative Neutron Decay

A new experiment aimed at studying radiative neutron decay is proposed. The respective experimental procedure reduces to measuring the time spectra of triple coincidences of the emitted photon, beta electron, and recoil proton along with the spectrum of double coincidences of ordinary decay products. By means of this procedure, we were able to measure for the first time the branching ratio for radiative neutron decay, BR = (3.2 ± 1.6) × 10{sup −3} (at a confidence level of C.L. = 99.7%, the photon energy being in excess of 35 keV) in 2005 at our old setup. The average value of this branching ratio was greater by a factor of 1.5 than its theoretical counterpart calculated on the basis of the Standard Model. However, we cannot state that we have seen a deviation fromthe StandardModel prediction since the experimental error was quite large in that experiment. The present study is devoted to implementing, by means of the popular Geant4 code package, a computer analog of the respective experiment at a new facility. Our calculations reveal that the resulting geometri©factor values make it possible to a accumulate, in a live experiment, a data sample sufficient for measuring the above branching ratio to a precision of a few percent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AEcroscopy: A Software–Hardware Framework Empowering Microscopy Toward Automated and Autonomous Experimentation

Microscopy has been pivotal in improving the understanding of structure-function relationships at the nanoscale and is by now ubiquitous in most characterization labs. However, traditional microscopy operations are still limited largely by a human-centric click-and-go paradigm utilizing vendor-provided software, which limits the scope, utility, efficiency, effectiveness, and at times reproducibility of microscopy experiments. Here, in this work, a coupled software–hardware platform is developed that consists of a software package termed AEcroscopy (short for Automated Experiments in Microscopy), along with a field-programmable-gate-array device with LabView-built customized acquisition scripts, which overcome these limitations and provide the necessary abstractions toward full automation of microscopy platforms. The platform works across multiple vendor devices on scanning probe microscopes and electron microscopes. It enables customized scan trajectories, processing functions that can be triggered locally or remotely on processing servers, user-defined excitation waveforms, standardization of data models, and completely seamless operation through simple Python commands to enable a plethora of microscopy experiments to be performed in a reproducible, automated manner. This platform can be readily coupled with existing machine-learning libraries and simulations, to provide automated decision-making and active theory-experiment optimization to turn microscopes from characterization tools to instruments capable of autonomous model refinement and physics discovery.

47 OTHER INSTRUMENTATION↗

AtomAI framework for deep learning analysis of image and spectroscopy data in electron and scanning probe microscopy

Over the past several decades, electron and scanning probe microscopes have become critical components of condensed matter physics, materials science and chemistry research. At the same time, the infrastructure for establishing a connection between microscopy observations and materials behaviour over a broader parameter space is lacking. In this work, we introduce AtomAI, an open-source software package bridging instrument-specific Python libraries, deep learning and simulation tools into a single ecosystem. AtomAI allows direct applications of deep neural networks for atomic and mesoscopic image segmentation converting image and spectroscopy data into class-based local descriptors for downstream tasks such as statistical and graph analysis. For atomically resolved imaging data, the output is types and positions of atomic species, with an option for subsequent refinement. AtomAI further allows the implementation of a broad range of image and spectrum analysis functions, including invariant variational autoencoders for disentangling structural factors of variation and im2spec type of encoder–decoder models for mapping structure–property relationships. Finally, our framework allows seamless connection to the first principles modelling with a Python interface on the inferred atomic positions.

36 MATERIALS SCIENCE↗

SU-E-T-30: A Factor for Converting Dose to a Gold Nanoparticle Mixture to a Biologically-Relevant Dose

Purpose: Monte Carlo studies of gold nanoparticle (GNP) dose enhancement on macroscopic scales in radiotherapy have modeled GNPs in tissue as a homogeneous mixture of gold and tissue. Using an explicit model of GNPs randomly positioned in a small volume (1 µm{sup 3}) of tissue, this study aims to quantify the dose to the biologically relevant component of a goldtissue mixture, enabling a conversion from macroscopically-scored dose. Methods: Using the PENELOPE Monte Carlo code with the penEasy package, we modeled a 1 µm{sup 3} volume containing either a tissue-gold mixture or GNPs suspended in ICRU 4-component tissue at various gold concentrations (0, 5, 10, and 15 mg Au/g tissue) and GNP diameters (20, 30, 40, 50 nm). The volume was irradiated with monoenergetic photon and electron beams, ranging from 110 eV to 6 MeV. Interaction forcing was utilized to increase simulation efficiency. Energy deposition was scored in the tissue for each case and was converted to dose. For each scenario, we calculated a conversion factor, the ratio of dose-to-tissue to dose-to-mixture as a function of energy. Results: The conversion factor was plotted as a function of energy for both photons and electrons. For electrons, the conversion factor was relatively unaffected by any of the parameters, including energy, ranging between 0.98–1.02. For photons, the factor was very energy dependent, with a range of 0.49–1.02. The factor was lowest for 10–100 keV photons. The conversion factor generally decreased with increasing GNP concentration and increasing GNP size. Conclusion: With a large variation in the conversion factor with incident energy, dose deposition is dependent on the spectrum incident on a volume. By scoring the energy spectrum in a given volume, one can provide a scenario-specific conversion factor, allowing fast, detailed Monte Carlo simulations without the need for explicit GNP-definition.

60 APPLIED LIFE SCIENCES↗

Global Structure of a Three-Way Junction in a Phi29 Packaging RNA Dimer Determined Using Site-Directed Spin Labeling

The condensation of bacteriophage phi29 genomic DNA into its preformed procapsid requires the DNA packaging motor, which is the strongest known biological motor. The packaging motor is an intricate ring-shaped protein/RNA complex, and its function requires an RNA component called packaging RNA (pRNA). Current structural information on pRNA is limited, which hinders studies of motor function. Here, we used site-directed spin labeling to map the conformation of a pRNA three-way junction that bridges binding sites for the motor ATPase and the procapsid. The studies were carried out on a pRNA dimer, which is the simplest ring-shaped pRNA complex and serves as a functional intermediate during motor assembly. Using a nucleotide-independent labeling scheme, stable nitroxide radicals were attached to eight specific pRNA sites without perturbing RNA folding and dimer formation, and a total of 17 internitroxide distances spanning the three-way junction were measured using Double Electron-Electron Resonance spectroscopy. The measured distances, together with steric chemical constraints, were used to select 3662 viable three-way junction models from a pool of 65 billion. The results reveal a similar conformation among the viable models, with two of the helices (HT and HL) adopting an acute bend. This is in contrast to a recently reported pRNA tetramer crystal structure, in which HT and HL stack onto each other linearly. The studies establish a new method for mapping global structures of complex RNA molecules, and provide information on pRNA conformation that aids investigations of phi29 packaging motor and developments of pRNA-based nanomedicine and nanomaterial.

59 BASIC BIOLOGICAL SCIENCES↗

The very high n Rydberg series of Ar 16+ in Alcator C-Mod tokamak plasmas

We report x-ray transitions of the very high-n Rydberg series in Ar 16+ have been observed from Alcator C-Mod tokamak plasmas. Individual emission lines up to 1s16p-1s 2 have been resolved and the central chord line brightnesses with principal quantum number n between 7 and 16 are generally found to decay as 1/n α , with α slightly larger than 3. In the plasma periphery, emission from 1s9p-1s 2 and 1s10p-1s 2 are found to be significantly enhanced relative to this decrease, indicative of selected population of these levels through charge exchange between background neutral deuterium in the ground state and Ar 17+ . An unresolved feature between the wavelengths of 1s27p-1s 2 and 1s30p-1s 2 is also present, which arises through charge exchange with neutral deuterium in the n* = 3 excited state. The brightnesses of transitions populated by charge exchange are spatially up/down asymmetric, with an excess on the side of the magnetic surface X-point. The relative brightness of the unresolved very high-n feature compared to 1s7p-1s 2 is found to increase with electron temperature and decrease with electron density. Simulations of line emission just on the long wavelength side of the Ar 16+ ionization limit indicate that the principal quantum number decay exponent is closer to α = 4 at very high n. The brightness dependence on n below 16 is in excellent agreement with calculations from the flexible atomic code package.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PCB-on-DBC GaN Power Module Design with High-Density Integration and Double-Sided Cooling

Lateral gallium nitride (GaN) high-electron-mobility transistors (HEMTs) present better electrical characteristics compared to silicon or silicon carbide devices such as high switching speed and low gate charge, but also present additional challenges on the module design. Here, this paper discusses a high-density GaN power module with double-sided cooling, low inductance, on-package decoupling capacitors, and integrated gate drivers. The GaN dies as well as the gate drive are sandwiched between the printed circuit board (PCB) and direct bonded copper (DBC) substrate to achieve compact loop and double-sided cooling effect. Design considerations and thermal performance are analyzed. A module assembly procedure is presented utilizing the layer-by-layer attachment process. Finally, a 2.7 cm x 1.8 cm half-bridge GaN power module is fabricated and tested, achieving a low power-loop inductance of 1.03 nH, and the overshoot voltage of the switching waveform is less than 5% under a 400-V/25-A double-pulse test. The thermal resistance is 0.32 K/W, verified by simulation and experimental results. The design and assembly process can be generalized and applied to high power applications to achieve high power density and high performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gamma electron vertex imaging and application to beam range verification in proton therapy

Purpose: This paper describes a new gamma-ray imaging method, ''gamma electron vertex imaging (GEVI)'', which can be used for precise beam range verification in proton therapy. Methods: In GEVI imaging, the high-energy gammas from a source or nuclear interactions are first converted, by Compton scattering, to electrons, which subsequently are traced by hodoscopes to determine the location of the gamma source or the vertices of the nuclear interactions. The performance of GEVI imaging for use in-beam range verification was evaluated by Monte Carlo simulations employing geant4 equipped with the QGSP{sub B}IC{sub H}P physics package. Results: Our simulation results show that GEVI imaging can determine the proton beam range very accurately, within 2-3 mm of error, even without any sophisticated analysis. The results were obtained under simplified conditions of monoenergetic pencil beams stopped in a homogeneous phantom and on the basis of the obtained results it is expected to achieve submillimeter accuracy in proton beam range measurement. Conclusions: If future experimental work confirms the simulated results presented in this paper, the use of GEVI imaging is expected to have a great potential in increasing the accuracy of proton beam range verification in a patient, resulting in significant improvement of treatment effectiveness by enabling tight conformation of radiation dose to the tumor volume and patient safety.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate design of megadalton-scale two-component icosahedral protein complexes

Nature provides many examples of self- and co-assembling protein-based molecular machines, including icosahedral protein cages that serve as scaffolds, enzymes, and compartments for essential biochemical reactions and icosahedral virus capsids, which encapsidate and protect viral genomes and mediate entry into host cells. Inspired by these natural materials, we report the computational design and experimental characterization of co-assembling, two-component, 120-subunit icosahedral protein nanostructures with molecular weights (1.8 to 2.8 megadaltons) and dimensions (24 to 40 nanometers in diameter) comparable to those of small viral capsids. Electron microscopy, small-angle x-ray scattering, and x-ray crystallography show that 10 designs spanning three distinct icosahedral architectures form materials closely matching the design models. In vitro assembly of icosahedral complexes from independently purified components occurs rapidly, at rates comparable to those of viral capsids, and enables controlled packaging of molecular cargo through charge complementarity. The ability to design megadalton-scale materials with atomic-level accuracy and controllable assembly opens the door to a new generation of genetically programmable protein-based molecular machines.

59 BASIC BIOLOGICAL SCIENCES↗

Documentation of operational protocol for the use of MAMA software

Image analysis of Scanning Electron Microscope (SEM) micrographs is a complex process that can vary significantly between analysts. The factors causing the variation are numerous, and the purpose of Task 2b is to develop and test a set of protocols designed to minimize variation in image analysis between different analysts and laboratories, specifically using the MAMA software package, Version 2.1. The protocols were designed to be “minimally invasive”, so that expert SEM operators will not be overly constrained in the way they analyze particle samples. The protocols will be tested using a round-robin approach where results from expert SEM users at Los Alamos National Laboratory, Lawrence Livermore National Laboratory, Pacific Northwest National Laboratory, Savannah River National Laboratory, and the National Institute of Standards and Testing will be compared. The variation of the results will be used to quantify uncertainty in the particle image analysis process. The round-robin exercise will proceed with 3 levels of rigor, each with their own set of protocols, as described below in Tasks 2b.1, 2b.2, and 2b.3. The uncertainty will be developed using NIST standard reference material SRM 1984 “Thermal Spray Powder – Particle Size Distribution, Tungsten Carbide/Cobalt (Acicular)” [Reference 1]. Full details are available in the Certificate of Analysis, posted on the NIST website (http://www.nist.gov/srm/).

97 MATHEMATICS AND COMPUTING↗

Quantum Chemical Treatment of Strongly Correlated Magnetic Systems Based on Heavy Elements. Final Report

The objective of this project over the years has been to develop novel quantum chemical methods and employ them to study the chemistry of systems containing actinides, and transactinides. We have focused on their electronic and spectroscopic properties, their reactivity and utilization as single molecule magnets. We have developed wave-function based methods that are optimal to treat strongly correlated systems, namely systems with many electronic configurations that are all important and should be treated on an equal foot. Moreover, relativistic effects have to be included in the model, with special focus on spin-orbit coupling. We have derived our theories and developed our codes and made them available to the community as parts of open source packages. We have modelled systems in collaboration with experimentalists in the program, so that we could address some of the questions that are relevant to this community. We have also worked in collaboration with people at Lawrence Livermore National Laboratories on a project on super-heavy atoms. We hope that our theoretical predictions will inspire novel experiments. We have trained about 10 students/postdocs during this period, which are now faculty, researchers at national laboratories and in companies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Very High n Rydberg Series of Ar^16+ in Alcator C-Mod Tokamak Plasmas

X-ray transitions of the very high-n Rydberg series in Ar^16+ have been observed from Alcator C-Mod tokamak plasmas. Individual emission lines up to 1s16p - 1s^2 have been resolved and the central chord line brightnesses with principal quantum number n between 7 and 16 are generally found to decay as 1/n^alpha, with alpha slightly larger than 3. In the plasma periphery, emission from 1s9p - 1s^2 and 1s10p - 1s^2 are found to be significantly enhanced relative to this decrease, indicative of selected population of these levels through charge exchange between background neutral deuterium in the ground state and Ar^17+. An unresolved feature between the wavelengths of 1s27p - 1s^2 and 1s30p - 1s^2 is also present, which arises through charge exchange with neutral deuterium in the n^* = 3 excited state. The brightnesses of transitions populated by charge exchange are spatially up/down asymmetric, with an excess on the side of the magnetic surface X-point. The relative brightness of the unresolved very high-n feature compared to 1s7p - 1s^2 is found to increase with electron temperature and decrease with electron density. Simulations of line emission just on the long wavelength side of the Ar^16$ ionization limit indicate that the principal quantum number decay exponent is closer to alpha = 4 at very high n. The brightness dependence on n below 16 is in excellent agreement with calculations from the Flexible Atomic Code package.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanical Design of the LSST Camera

The LSST camera is a tightly packaged, hermetically-sealed system that is cantilevered into the main beam of the LSST telescope. It is comprised of three refractive lenses, on-board storage for five large filters, a high-precision shutter, and a cryostat that houses the 3.2 giga-pixel CCD focal plane along with its support electronics. The physically large optics and focal plane demand large structural elements to support them, but the overall size of the camera and its components must be minimized to reduce impact on the image stability. Also, focal plane and optics motions must be minimized to reduce systematic errors in image reconstruction. Design and analysis for the camera body and cryostat will be detailed.

47 OTHER INSTRUMENTATION↗

Case studies in bias reduction and inference for electronic health record data with selection bias and phenotype misclassification

Electronic health records (EHR) are not designed for population‐based research, but they provide easy and quick access to longitudinal health information for a large number of individuals. Many statistical methods have been proposed to account for selection bias, missing data, phenotyping errors, or other problems that arise in EHR data analysis. However, addressing multiple sources of bias simultaneously is challenging. We developed a methodological framework (R package, SAMBA ) for jointly handling both selection bias and phenotype misclassification in the EHR setting that leverages external data sources. These methods assume factors related to selection and misclassification are fully observed, but these factors may be poorly understood and partially observed in practice. As a follow‐up to the methodological work, we demonstrate how to apply these methods for two real‐world case studies, and we evaluate their performance. In both examples, we use individual patient‐level data collected through the University of Michigan Health System and various external population‐based data sources. In case study (a), we explore the impact of these methods on estimated associations between gender and cancer diagnosis. In case study (b), we compare corrected associations between previously identified genetic loci and age‐related macular degeneration with gold standard external summary estimates. These case studies illustrate how to utilize diverse auxiliary information to achieve less biased inference in EHR‐based research.

60 APPLIED LIFE SCIENCES↗

Leaf gas exchange and fitted parameters, San Lorenzo, Panama, 2020

This data package contains photosynthetic CO2 response curves (ACi curves), light response curves (AQ curves), dark adapted dark respiration, conductance curves, and survey measurements for leaves measured at the San Lorenzo forest canopy crane site, Panama (PA-SLZ) from January to March 2020. Leaves were sampled from both the top of the canopy and multiple heights within the canopy from 10 vertical profiles and included around 50 species. In addition, six core species were also measured, from the top of the canopy. Fitted maximum carboxylation rate (Vcmax), maximum electron transport rate (Jmax), and triose phosphate utilization rate (TPU) were derived from measured data as well as the convexity, light use efficiency, apparent quantum yield, and Rdark. The measurements can also be used to derive the conductance parameters g0 and g1 of stomatal model. All the gas exchange data and metadata are presented in .csv files and complete instrument output are included in .zip folders. Data and metadata meet the ESS-DIVE leaf-level gas exchange reporting format requirements. The protocol details are provided as pdf documents. In addition to gas exchange data described here these samples were also used for measurement of leaf optical properties, carbon and nitrogen content, and leaf mass per unit leaf area (LMA) these data can be cross linked using the unique sample ID and are provided in separate related data packages. Sample information including canopy elevation and leaf area index (LAI) can be found in the related “Leaf and canopy traits” data package.

54 ENVIRONMENTAL SCIENCES↗