Search NASA⌕ Search

SEARCH · Search NASA

Results for “error reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Exploring the feasibility of lossy compression for PDE simulations

Checkpoint restart plays an important role in high-performance computing (HPC) applications, allowing simulation runtime to extend beyond a single job allocation and facilitating recovery from hardware failure. Yet, as machines grow in size and in complexity, traditional approaches to checkpoint restart are becoming prohibitive. Current methods store a subset of the application’s state and exploit the memory hierarchy in the machine. However, as the energy cost of data movement continues to dominate, further reductions in checkpoint size are needed. Lossy compression, which can significantly reduce checkpoint sizes, offers a potential to reduce computational cost in checkpoint restart. This article investigates the use of numerical properties of partial differential equation (PDE) simulations, such as bounds on the truncation error, to evaluate the feasibility of using lossy compression in checkpointing PDE simulations. Restart from a checkpoint with lossy compression is considered for a fail-stop error in two time-dependent HPC application codes: PlasComCM and Nek5000. Results show that error in application variables due to a restart from a lossy compressed checkpoint can be masked by the numerical error in the discretization, leading to increased efficiency in checkpoint restart without influencing overall accuracy in the simulation.

97 MATHEMATICS AND COMPUTING↗

APPLYING CASCADED PARAMETER SCAN TO STUDY TOP-OFF SAFETY IN NSLS-II STORAGE RING

In this paper we introduce a new algorithm, the cascaded parameter scan method, to efficiently carry out the scan over magnet parameters in the safety analysis for storage ring top-off injection. In top-off safety analysis, one must track particles populating phase space through a beamline containing magnets and apertures and clearly demonstrate that for all possible magnet settings and errors, all particles are lost on scrapers within the properly shielded region. In the usual approach, the number of tracking runs increases exponentially with the number of magnet settings. In the cascaded parameter scan method, the number of tracking runs only increases linearly. This reduction of exponential to linear dependence on the number of set-points, greatly reduces the required computation time and allows one to more densely populate phase space and to increase the number of set-points scanned for each magnet. An example of applying this approach to analyze an NSLS-II beamline, the damping wiggler beamline, is also given.

43 PARTICLE ACCELERATORS↗

Chemical Reduction of Nd 1.85 Ce 0.15 CuO 4− δ Powders in Supercritical Sodium Ammonia Solutions

Nd 1.85 Ce 0.15 CuO 4− δ powders are chemically reduced in supercritical sodium ammonia solutions from room temperature to 350°C. The crystallographic structure of the reduced powders is investigated from Rietveld refinement of X-ray powder diffraction. The atomic positions are maintained constant within experimental errors while temperature factors of all atoms increase significantly after the chemical treatments, especially of Nd/Ce atoms. The ammonothermally reduced Nd 1.85 Ce 0.15 CuO 4− δ powders show diamagnetic below 24 K which is contributed to the lower oxygen content and higher temperature factors of atoms in the treated compound. The ammonothermal method paves a new way to reduce oxides in supercritical solutions near room temperature.

Dias, Yasmin↗

Galerkin v. least-squares Petrov–Galerkin projection in nonlinear model reduction

Least-squares Petrov–Galerkin (LSPG) model-reduction techniques such as the Gauss–Newton with Approximated Tensors (GNAT) method have shown promise, as they have generated stable, accurate solutions for large-scale turbulent, compressible flow problems where standard Galerkin techniques have failed. Furthermore, there has been limited comparative analysis of the two approaches. This is due in part to difficulties arising from the fact that Galerkin techniques perform optimal projection associated with residual minimization at the time-continuous level, while LSPG techniques do so at the time-discrete level. This work provides a detailed theoretical and computational comparison of the two techniques for two common classes of time integrators: linear multistep schemes and Runge–Kutta schemes. We present a number of new findings, including conditions under which the LSPG ROM has a time-continuous representation, conditions under which the two techniques are equivalent, and time-discrete error bounds for the two approaches. Perhaps most surprisingly, we demonstrate both theoretically and computationally that decreasing the time step does not necessarily decrease the error for the LSPG ROM; instead, the time step should be ‘matched’ to the spectral content of the reduced basis. In numerical experiments carried out on a turbulent compressible-flow problem with over one million unknowns, we show that increasing the time step to an intermediate value decreases both the error and the simulation time of the LSPG reduced-order model by an order of magnitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring galaxy cluster masses with CMB lensing using a Maximum Likelihood estimator: statistical and systematic error budgets for future experiments

We develop a Maximum Likelihood estimator (MLE) to measure the masses of galaxy clusters through the impact of gravitational lensing on the temperature and polarization anisotropies of the cosmic microwave background (CMB). We show that, at low noise levels in temperature, this optimal estimator outperforms the standard quadratic estimator by a factor of two. For polarization, we show that the Stokes Q/U maps can be used instead of the traditional E- and B-mode maps without losing information. We test and quantify the bias in the recovered lensing mass for a comprehensive list of potential systematic errors. Using realistic simulations, we examine the cluster mass uncertainties from CMB-cluster lensing as a function of an experiment’s beam size and noise level. We predict the cluster mass uncertainties will be 3 - 6% for SPT-3G, AdvACT, and Simons Array experiments with 10,000 clusters and less than 1% for the CMB-S4 experiment with a sample containing 100,000 clusters. The mass constraints from CMB polarization are very sensitive to the experimental beam size and map noise level: for a factor of three reduction in either the beam size or noise level, the lensing signal-to-noise improves by roughly a factor of two.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic tuning of the Community Atmospheric Model (CAM5) by using short-term hindcasts with an improved downhill simplex optimization method

Traditional trial-and-error tuning of uncertain parameters in global atmospheric general circulation models (GCMs) is time consuming and subjective. This study explores the feasibility of automatic optimization of GCM parameters for fast physics by using short-term hindcasts. An automatic workflow is described and applied to the Community Atmospheric Model (CAM5) to optimize several parameters in its cloud and convective parameterizations. We show that the auto-optimization leads to 10 % reduction of the overall bias in CAM5, which is already a well-calibrated model, based on a predefined metric that includes precipitation, temperature, humidity, and longwave/shortwave cloud forcing. The computational cost of the entire optimization procedure is about equivalent to a single 12-year atmospheric model simulation. The tuning reduces the large underestimation in the CAM5 longwave cloud forcing by decreasing the threshold relative humidity and the sedimentation velocity of ice crystals in the cloud schemes; it reduces the overestimation of precipitation by increasing the adjustment time in the convection scheme. The physical processes behind the tuned model performance for each targeted field are discussed. Limitations of the automatic tuning are described, including the slight deterioration in some targeted fields that reflect the structural errors of the model. It is pointed out that automatic tuning can be a viable supplement to process-oriented model evaluations and improvement.

54 ENVIRONMENTAL SCIENCES↗

Antineutrino analysis for continuous monitoring of nuclear reactors: Sensitivity study

This paper explores the various contributors to uncertainty on predictions of the antineutrino source term which is used for reactor antineutrino experiments and is proposed as a safeguard mechanism for future reactor installations. The errors introduced during simulation of the reactor burnup cycle from variation in nuclear reaction cross sections, operating power, and other factors are combined with those from experimental and predicted antineutrino yields, resulting from fissions, evaluated, and compared. The most significant contributor to uncertainty on the reactor antineutrino source term when the reactor was modeled in 3D fidelity with assembly-level heterogeneity was found to be the uncertainty on the antineutrino yields. Using the reactor simulation uncertainty data, the dedicated observation of a rigorously modeled small, fast reactor by a few-ton near-field detector was estimated to offer reduction of uncertainty on antineutrino yields in the 3.0–6.5 MeV range to a few percent for the primary power-producing fuel isotopes, even with zero prior knowledge of the yields.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ISABELA for effective in situ compression of scientific data: ISABELA FOR EFFECTIVE IN-SITU REDUCTION OF SPATIO-TEMPORAL DATA

Exploding dataset sizes from extreme-scale scientific simulations necessitates efficient data management and reduction schemes to mitigate I/O costs. With the discrepancy between I/O bandwidth and computational power, scientists are forced to capture data infrequently, thereby making data collection an inherently lossy process. Although data compression can be an effective solution, the random nature of real-valued scientific datasets renders lossless compression routines ineffective. These techniques also impose significant overhead during decompression, making them unsuitable for data analysis and visualization, which require repeated data access. To address this problem, we propose an effective method for In situ Sort-And-B-spline Error-bounded Lossy Abatement (ISABELA) of scientific data that is widely regarded as effectively incompressible. With ISABELA, we apply a pre-conditioner to seemingly random and noisy data along spatial resolution to achieve an accurate fitting model that guarantees a ≥0.99 correlation with the original data. We further take advantage of temporal patterns in scientific data to compress data b ≈ 85%, while introducing only a negligible overhead on simulations in terms of runtime. ISABELA significantly outperforms existing lossy compression methods, such as wavelet compression, in terms of data reduction and accuracy. We extend upon our previous paper by additionally building a communication-free, scalable parallel storage framework on top of ISABELA-compressed data that is ideally suited for extreme-scale analytical processing. The basis for our storage framework is an inherently local decompression method (it need not decode the entire data), which allows for random access decompression and low-overhead task division that can be exploited over heterogeneous architectures. Furthermore, analytical operations such as correlation and query processing run quickly and accurately over data in the compressed space. Copyright © 2012 John Wiley & Sons, Ltd.

Computer Science↗

Prostate Intrafraction Motion Assessed by Simultaneous kV Fluoroscopy at MV Delivery II: Adaptive Strategies

Purpose: To investigate potential benefits of adaptive strategies for managing prostate intrafractional uncertainties when interfraction motion is corrected online. Methods and Materials: Prostate intrafraction motion was measured using kV fluoroscopy during MV delivery for 571 fractions from 30 hypofractionated radiotherapy patients. We evaluated trending over treatment course using analysis of variance statistics, and we evaluated the ability to correct patient-specific systematic error and apply patient-specific statistical margins after 2 to 15 fractions to compensate 90% of motion. We also evaluated the ability to classify patients into small- and large-motion subgroups based on the first 2 to 20 fractions using discriminant analysis. Results: No time trend was observed over treatment course, and intrafraction motion was patient specific (p < 0.0001). Systematic error in the first week correlated well with that in subsequent weeks, with correlation coefficients of 0.53, 0.50, and 0.41 in right-left (RL), anterior-posterior (AP), and superior-inferior (SI), respectively. After 5 fractions, the adaptive strategy resulted in average margin reductions of 0.3, 0.7, and 0.7 mm in RL, AP, and SI, respectively, with margins ranging from 1 to 3.2 mm in RL, 2 to 7.0 mm in AP, and 2 to 6.6 mm in SI. By contrast, population margins to include the same percentage of motion were 1.7, 4.0, and 4.1 mm. After 2 and 5 fractions, patients were classified into small- and large-motion groups with {approx}77% and {approx}83% accuracy. Conclusions: Adaptive strategies are feasible and beneficial for intrafraction motion management in prostate cancer online image guidance. Patients may be classified into large- and small-motion groups in early fractions using discriminant analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A CGPS look at the spiral structure of the outer Milky Way. I. Distances and velocities to star-forming regions

We present a new catalog of spectrophotometric distances and line of sight systemic velocities to 103 H ii regions between 90{sup ∘}⩽ℓ⩽195{sup ∘} (longitude quadrants II and part of III). Two new velocities for each region are independently measured using 1 arcmin resolution 21 cm H i and 2.6 mm {sup 12}CO line maps (from the Canadian Galactic Plane Survey and Five College Radio Astronomy Observatory Outer Galaxy Surveys) that show where gaseous shells are observed around the periphery of the ionized gas. Known and neighboring O- and B-type stars with published UBV photometry and MK classifications are overlaid onto 21 cm continuum maps, and those stars observed within the boundary of the H ii emission (and whose distance is not more than three times the standard deviation of the others) are used to calculate new mean stellar distances to each of the 103 nebulae. Using this approach of excluding distance outliers from the mean distance to a group of many stars in each H ii region lessens the impact of anomalous reddening for certain individuals. The standard deviation of individual stellar distances in a cluster is typically 20% per stellar distance, and the error in the mean distance to the cluster is typically ±10%. Final mean distances of nine common objects with very long baseline interferometry parallax distances show a 1:1 correspondence. Further, comparison with previous catalogs of H ii regions in these quadrants shows a 50% reduction in scatter for the distance to Perseus spiral arm objects in the same region, and a reduction by ∼1/√2 in scatter around a common angular velocity relative to the Sun Ω−Ω{sub 0}(km s{sup −1} kpc{sup −1}). The purpose of the catalog is to provide a foundation for more detailed large-scale Galactic spiral structure and dynamics (rotation curve, density wave streaming) studies in the 2nd and 3rd quadrants, which from the Sun’s location is the most favorably viewed section of the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Latent uncertainties of the precalculated track Monte Carlo method

Purpose: While significant progress has been made in speeding up Monte Carlo (MC) dose calculation methods, they remain too time-consuming for the purpose of inverse planning. To achieve clinically usable calculation speeds, a precalculated Monte Carlo (PMC) algorithm for proton and electron transport was developed to run on graphics processing units (GPUs). The algorithm utilizes pregenerated particle track data from conventional MC codes for different materials such as water, bone, and lung to produce dose distributions in voxelized phantoms. While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from the limited number of unique tracks in the pregenerated track bank is missing from the paper. With a proper uncertainty analysis, an optimal number of tracks in the pregenerated track bank can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pregenerated for electrons and protons using EGSnrc and GEANT4 and saved in a database. The PMC algorithm for track selection, rotation, and transport was implemented on the Compute Unified Device Architecture (CUDA) 4.0 programming framework. PMC dose distributions were calculated in a variety of media and compared to benchmark dose distributions simulated from the corresponding general-purpose MC codes in the same conditions. A latent uncertainty metric was defined and analysis was performed by varying the pregenerated track bank size and the number of simulated primary particle histories and comparing dose values to a “ground truth” benchmark dose distribution calculated to 0.04% average uncertainty in voxels with dose greater than 20% of D{sub max}. Efficiency metrics were calculated against benchmark MC codes on a single CPU core with no variance reduction. Results: Dose distributions generated using PMC and benchmark MC codes were compared and found to be within 2% of each other in voxels with dose values greater than 20% of the maximum dose. In proton calculations, a small (≤1 mm) distance-to-agreement error was observed at the Bragg peak. Latent uncertainty was characterized for electrons and found to follow a Poisson distribution with the number of unique tracks per energy. A track bank of 12 energies and 60000 unique tracks per pregenerated energy in water had a size of 2.4 GB and achieved a latent uncertainty of approximately 1% at an optimal efficiency gain over DOSXYZnrc. Larger track banks produced a lower latent uncertainty at the cost of increased memory consumption. Using an NVIDIA GTX 590, efficiency analysis showed a 807 × efficiency increase over DOSXYZnrc for 16 MeV electrons in water and 508 × for 16 MeV electrons in bone. Conclusions: The PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty of 1% with a large efficiency gain over conventional MC codes. Before performing clinical dose calculations, models to calculate dose contributions from uncharged particles must be implemented. Following the successful implementation of these models, the PMC method will be evaluated as a candidate for inverse planning of modulated electron radiation therapy and scanned proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Validation of CT dose-reduction simulation

The objective of this research was to develop and validate a custom computed tomography dose-reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy-integrating detectors, tube-current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root-mean-square relative error metric to quantify agreement in noise processes. Four-alternative forced-choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The ''just noticeable difference (JND)'' in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed (p>0.54), justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within 5.6%{+-}1.6% (standard deviation), which was then propagated into the image domain with errors less than 4.1%{+-}1.6%. Cadaver measurements indicated that image noise was matched to within 2.6%{+-}2.0%. More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images (p=0.86) was observed. JND studies indicated that observers' sensitivity to change in noise levels corresponded to a 25% difference in dose, which is far larger than the noise accuracy achieved by simulation. In summary, the dose-reduction simulation tool demonstrated excellent accuracy in providing realistic images. The methodology promises to be a useful tool for researchers and radiologists to explore dose reduction protocols in an effort to produce diagnostic images with radiation dose ''as low as reasonably achievable.''.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automatic tuning of the Community Atmospheric Model CAM5.3 by using short-term hindcasts with an improved downhill simplex optimization method

Traditional trial-and-error tuning of uncertain parameters in global atmospheric General Circulation Models (GCM) is time consuming and subjective. This study explores the feasibility of automatic optimization of GCM parameters for fast physics by using short-term hindcasts. An automatic workflow is described and applied to the Community Atmospheric Model (CAM5) to optimize several parameters in its cloud and convective parameterizations. We show that the auto-optimization leads to 10 % reduction of the overall bias in CAM5, which is already a well calibrated model, based on a pre-defined metric that includes precipitation, temperature, humidity, and longwave/shortwave cloud forcing. The computational cost of the entire optimization procedure is about equivalent to about a single 12-year atmospheric model simulation. The tuning reduces the large underestimation in the CAM5 longwave cloud forcing by decreasing the threshold relative humidity and the sedimentation velocity of ice crystals in the cloud schemes; it reduces the overestimation of precipitation by increasing the adjustment time in the convection scheme. The physical processes behind the tuned model performance for each targeted field are discussed. Limitations of the automatic tuning are described, including the slight deterioration in some targeted fields that reflect the structural errors of the model. It is pointed out that automatic tuning can be a viable supplement to process-oriented model evaluations and improvement.

54 ENVIRONMENTAL SCIENCES↗

An adjoint method for neoclassical stellarator optimization

Stellarators remain an enticing route to steady-state fusion power. However, to achieve the required confinement, the magnetic geometry must be highly optimized. This optimization requires navigating high-dimensional spaces, often necessitating the use of gradient-based methods. The gradient of the neoclassical fluxes is expensive to compute with classical methods, requiring $O(N)$ flux computations, where $N$ is the number of parameters. To reduce the cost of the gradient computation, we present an adjoint method for computing the derivatives of moments of the neoclassical distribution function for stellarator optimization. The linear adjoint method allows derivatives of quantities which depend on solutions of a linear system, such as moments of the distribution function, to be computed with respect to many parameters from the solution of only two linear systems. This reduces the cost of computing the gradient to the point that the finite-collisionality neoclassical fluxes can be used within an optimization loop. With the neoclassical adjoint method, we compute solutions of the drift kinetic equation and an adjoint drift kinetic equation to obtain derivatives of neoclassical quantities with respect to geometric parameters. When the number of parameters in the derivative is large ( $O(10^{2})$ ), this adjoint method provides up to a factor of 200 reduction in cost. We demonstrate adjoint-based optimization of the field strength to obtain minimal bootstrap current on a surface. With adjoint-based derivatives, we also compute the local sensitivity to magnetic perturbations on a flux surface and identify regions where tight tolerances on error fields are required for control of the bootstrap current or radial transport. Moreover, the solve for the ambipolar electric field is accelerated using a Newton method with derivatives obtained from the adjoint method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The application of wavelet shrinkage denoising to magnetic Barkhausen noise measurements

The application of Magnetic Barkhausen Noise (MBN) as a non-destructive method of defect detection has proliferated throughout the manufacturing community. Instrument technology and measurement methodology have matured commensurately as applications have moved from the R and D labs to the fully automated manufacturing environment. These new applications present a new set of challenges including a bevy of error sources. A significant obstacle in many industrial applications is a decrease in signal to noise ratio due to (i) environmental EMI and (II) compromises in sensor design for the purposes of automation. The stochastic nature of MBN presents a challenge to any method of noise reduction. An application of wavelet shrinkage denoising is proposed as a method of decreasing extraneous noise in MBN measurements. The method is tested and yields marked improvement on measurements subject to EMI, grounding noise, and even measurements in ideal conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Making inertial confinement fusion models more predictive

Computer models of inertial confinement fusion (ICF) implosions play an essential role in experimental design and interpretation as well as our understanding of fundamental physics under the most extreme conditions that can be reached in the laboratory. Building truly predictive models is a significant challenge, with the potential to greatly accelerate progress to high yield and ignition. One path to more predictive models is to use experimental data to update the underlying physics in a way that can be extrapolated to new experiments and regimes. We describe a statistical framework for the calibration of ICF simulations using data collected at the National Ignition Facility (NIF). We perform Bayesian inferences for a series of laser shots using an approach that is designed to respect the physics simulation as much as possible and then build a second model that links the individual-shot inferences together. We show that this approach is able to match multiple X-ray and neutron diagnostics for a whole series of NIF “BigFoot” shots. Within the context of 2D radiation hydrodynamic simulations, our inference strongly favors a significant reduction in fuel compression over other known degradation mechanisms (namely, hohlraum issues and engineering perturbations). This analysis is expanded using a multifidelity technique to pick fuel-ablator mix from several candidate causes of the degraded fuel compression (including X-ray preheat and shock timing errors). Finally, we use our globally calibrated model to investigate the extra laser drive energy that would be required to overcome the inferred fuel compression issues in NIF BigFoot implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NEW APPROACHES TO PHOTOMETRIC REDSHIFT PREDICTION VIA GAUSSIAN PROCESS REGRESSION IN THE SLOAN DIGITAL SKY SURVEY

Expanding upon the work of Way and Srivastava we demonstrate how the use of training sets of comparable size continue to make Gaussian process regression (GPR) a competitive approach to that of neural networks and other least-squares fitting methods. This is possible via new large-size matrix inversion techniques developed for Gaussian processes (GPs) that do not require that the kernel matrix be sparse. This development, combined with a neural-network kernel function appears to give superior results for this problem. Our best-fit results for the Sloan Digital Sky Survey (SDSS) Main Galaxy Sample using u, g, r, i, z filters gives an rms error of 0.0201 while our results for the same filters in the luminous red galaxy sample yield 0.0220. We also demonstrate that there appears to be a minimum number of training-set galaxies needed to obtain the optimal fit when using our GPR rank-reduction methods. We find that morphological information included with many photometric surveys appears, for the most part, to make the photometric redshift evaluation slightly worse rather than better. This would indicate that most morphological information simply adds noise from the GP point of view in the data used herein. In addition, we show that cross-match catalog results involving combinations of the Two Micron All Sky Survey, SDSS, and Galaxy Evolution Explorer have to be evaluated in the context of the resulting cross-match magnitude and redshift distribution. Otherwise one may be misled into overly optimistic conclusions.

79 ASTRONOMY AND ASTROPHYSICS↗

Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning

Purpose: Traditional computed tomography (CT) units provide a maximum scan field-of-view (sFOV) diameter of 50 cm and a limited bore size, which cannot accommodate a large patient habitus or an extended simulation setup in radiation therapy (RT). Wide-bore CT scanners with increased bore size were developed to address these needs. Some scanners have the capacity to reconstruct the CT images at an extended FOV (eFOV), through data interpolation or extrapolation, using projection data acquired with a conventional sFOV. Objects that extend past the sFOV for eFOV reconstruction may generate image artifacts resulting from truncated projection data; this may distort CT numbers and structure contours in the region beyond the sFOV. The purpose of this study was to evaluate the dosimetric impact of image artifacts from eFOV reconstruction with a wide-bore CT scanner in radiotherapy (RT) treatment planning. Methods: Testing phantoms (i.e., a mini CT phantom with equivalent tissue inserts, a set of CT normal phantoms and anthropomorphic phantoms of the thorax and the pelvis) were used to evaluate eFOV artifacts. Reference baseline images of these phantoms were acquired with the phantom centrally positioned within the sFOV. For comparison, the phantoms were then shifted laterally and scanned partially outside the sFOV, but still within the eFOV. Treatment plans were generated for the thoracic and pelvic anthropomorphic phantoms utilizing the Eclipse treatment planning system (TPS) to study the potential effects of eFOV artifacts on dose calculations. All dose calculations of baseline and test treatment plans were carried out using the same MU. Results: Results show that both body contour and CT numbers are altered by image artifacts in eFOV reconstruction. CT number distortions of up to -356 HU for bone tissue and up to 323 HU for lung tissue were observed in the mini CT phantom. Results from the large body normal phantom, which is close to a clinical patient size, show average CT number changes of up to -49 HU. Wider distribution (i.e., standard deviation) of the HU values was seen when the phantom was placed at more than 2.8 cm beyond the 50 cm sFOV. Anthropomorphic phantom studies with several standard beam configurations show that body contour distortion causes tumor dose calculation reduction of 3.0 and 1.9% for 6 and 23 MV x-rays, respectively, when not accounting for tissue heterogeneities during dose computation. When heterogeneity correction is used in planning, the competing effects of the body contour distortion and the CT number distortion cause a smaller error in tumor dose calculation. Less than 0.9% error in calculated dose was observed in volumetric modulated arc therapy (VMAT) treatment plans. Conclusions: The image artifacts from eFOV reconstruction alter the CT numbers and body contours of the imaged objects, which has the potential to produce inaccuracies in dose calculations during radiotherapy treatment planning. The radiation therapy team should be aware of these image artifacts and their effects on target dose calculations during CT simulation as well as treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗