Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental data error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

A comparison of deep-learning-based inpainting techniques for experimental X-ray scattering

The implementation is proposed of image inpainting techniques for the reconstruction of gaps in experimental X-ray scattering data. The proposed methods use deep learning neural network architectures, such as convolutional autoencoders, tunable U-Nets, partial convolution neural networks and mixed-scale dense networks, to reconstruct the missing information in experimental scattering images. In particular, the recovered pixel intensities are evaluated against their corresponding ground-truth values using the mean absolute error and the correlation coefficient metrics. The results demonstrate that the proposed methods achieve better performance than traditional inpainting algorithms such as biharmonic functions. Overall, tunable U-Net and mixed-scale dense network architectures achieved the best reconstruction performance among all the tested algorithms, with correlation coefficient scores greater than 0.9980.

97 MATHEMATICS AND COMPUTING↗

New figuring model based on surface slope profile for grazing-incidence reflective optics

Surface slope profile is widely used in the metrology of grazing-incidence reflective optics instead of surface height profile. Nevertheless, the theoretical and experimental model currently used in deterministic optical figuring processes is based on surface height, not on surface slope. This means that the raw slope profile data from metrology need to be converted to height profile to perform the current height-based figuring processes. The inevitable measurement noise in the raw slope data will introduce significant cumulative error in the resultant height profiles. As a consequence, this conversion will degrade the determinism of the figuring processes, and will have an impact on the ultimate surface figuring results. To overcome this problem, an innovative figuring model is proposed, which directly uses the raw slope profile data instead of the usual height data as input for the deterministic process. In this article, first the influence of the measurement noise on the resultant height profile is analyzed, and then a new model is presented; finally a demonstration experiment is carried out using a one-dimensional ion beam figuring process to demonstrate the validity of our approach.

36 MATERIALS SCIENCE↗

Data-Driven Modeling and Correction of Vehicle Dynamics

We develop a data-driven framework for learning and correcting nonautonomous vehicle dynamics. Physics-based vehicle models are often simplified for tractability and therefore exhibit inherent model-form uncertainty, motivating the need for data-driven correction. Moreover, nonautonomous dynamics are governed by time-dependent control inputs, which pose challenges in learning predictive models directly from temporal snapshot data. To address these, we reformulate the vehicle dynamics via a local parameterization of the time-dependent inputs, yielding a modified system composed ofa sequence of local parametric dynamical systems. Here, we approximate these parametric systems using two complementary approaches. First, we employ the dimension reduction and interpolation in parameter space (DRIPS) methodology to construct efficient linear surrogate models, equipped with lifted observable spaces and manifold-based operator interpolation. This enables data-efficient learning of vehicle models whose dynamics admit accurate linear representations in the lifted spaces. Second, for more strongly nonlinear systems, we employ flow map learning (FML), a deep neural network (DNN) approach that approximates the parametric evolution map without requiring special treatment of nonlinearities. We further extend FML with a transfer-learning-based model correction procedure, enabling the correction of misspecified prior models using only a sparse set of high-fidelity or experimental measurements, without assuming a prescribed form for the correction term. Through a suite of numerical experiments on unicycle, simplified bicycle, and slip-based bicycle models, we demonstrate that DRIPS offers robust and highly data-efficient learning of nonautonomous vehicle dynamics, while FML provides expressive nonlinear modeling and effective correction of model-form errors under severe data scarcity.

data-driven modeling↗

ISiCLE: A Quantum Chemistry Pipeline for Establishing in Silico Collision Cross Section Libraries

High throughput, comprehensive, and confident identifications of metabolites and other chemicals in biological and envi-ronmental samples will revolutionize our understanding of the role of these intriguing and chemically diverse molecules in biological systems. Despite recent technological advances, a metabolomics study still results in the detection of a dispropor-tionate number of features than cannot be confidently assigned to a chemical structure. This inadequacy is driven by the sin-gle most significant limitation in metabolomics: the reliance on reference libraries constructed through the analysis of au-thentic reference chemicals and the limited commercial availability of these compounds. To this end, we have developed the in silico chemical library engine (ISiCLE), a high-performance computing-friendly cheminformatics workflow for generating chemical properties. In the instantiation described here, we predict probable three-dimensional molecular conformers (i.e. conformational isomers) using chemical identifiers as input, from which collision cross sections (CCS) are derived. The ap-proach employs state-of-the-art first-principles simulation, distinguished by use of molecular dynamics, quantum chemistry, and ion mobility calculations to generate predictions, all without training data. Importantly, optimization of ISiCLE includ-ed a refactoring of the popular MOBCAL code for trajectory-based mobility calculations, improving its computational effi-ciency by over two orders of magnitude. Calculated CCS values were validated against 1,983 experimental CCS values and compared to previously reported CCS calculation approaches. Average CCS calculation absolute error is 3.2% with standard deviation 3.1%. An online database is introduced for sharing both calculated and experimental CCS values (metabolom-ics.pnnl.gov), initially including a CCS library with over 0.8M entries. Finally, three successful applications of molecule characterization using calculated CCS are described, including the identification of an environmental degradation product, the separation of molecular isomers, and the decoding of complex blinded mixtures of exposure chemicals. This work represents a promising method to address the limitations of small molecule identification, and offers alternatives to standards-based chemical identification amenable to high-performance computation.

Colby, Sean M↗

Experimental annotation of post-translational features and translated coding regions in the pathogen Salmonella Typhimurium

Complete and accurate genome annotation is crucial for comprehensive and systematic studies of biological systems. For example systems biology-oriented genome scale modeling efforts greatly benefit from accurate annotation of protein-coding genes to develop proper functioning models. However, determining protein-coding genes for most new genomes is almost completely performed by inference, using computational predictions with significant documented error rates (> 15%). Furthermore, gene prediction programs provide no information on biologically important post-translational processing events critical for protein function. With the ability to directly measure peptides arising from expressed proteins, mass spectrometry-based proteomics approaches can be used to augment and verify coding regions of a genomic sequence and importantly detect post-translational processing events. In this study we utilized “shotgun” proteomics to guide accurate primary genome annotation of the bacterial pathogen Salmonella Typhimurium 14028 to facilitate a systems-level understanding of Salmonella biology. The data provides protein-level experimental confirmation for 44% of predicted protein-coding genes, suggests revisions to 48 genes assigned incorrect translational start sites, and uncovers 13 non-annotated genes missed by gene prediction programs. We also present a comprehensive analysis of post-translational processing events in Salmonella, revealing a wide range of complex chemical modifications (70 distinct modifications) and confirming more than 130 signal peptide and N-terminal methionine cleavage events in Salmonella. This study highlights several ways in which proteomics data applied during the primary stages of annotation can improve the quality of genome annotations, especially with regards to the annotation of mature protein products.

59 BASIC BIOLOGICAL SCIENCES↗

Current Status of SAMMY [Slides]

SAMMY is used to analyze experimental data mainly in the resolved range to generate evaluated data files for use in transport codes. The code base in SAMMY is still mostly F77, i.e., fixed line length and almost no use of modules. SAMMY is used in production environments, so during the modernization its functionality cannot be lost. That means we cannot simply rewrite it from scratch. Modernization is needed to allow us to add new features (for example new and improved algorithms in the resolved range). SAMMY has a large suite of regression tests that can be run and whose outputs can be checked automatically. During the modernization process, we will not change the results of these regression tests, except if errors in the original coding are found and corrected. Future plans for SAMMY include converting all container array access to Fortran allocate (or use C++ storage) and finishing the conversion to use C++ storage for all resonance parameters. We have an initial C++ implementation of the cross section reconstruction from R-Matrix parameters, used in AMPX. We will update this code, add reconstruction of angular data and derivatives and will use it in AMPX and SAMMY. Once this is done, we can start to add new features to the R-Matrix algorithm, like complex channel radii or relativistic effects. We also intend to modularize SAMMY to separate cross section reconstruction, experimental effect etc. from the Bayes fitting routines.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neural Posterior Estimation for Scalable and Accurate Inverse Parameter Inference in Li-Ion Batteries

Diagnosing the internal state of Li-ion batteries is critical for battery research, operation of real-world systems, and prognostic evaluation of remaining lifetime. By using physics-based models to perform probabilistic parameter estimation via Bayesian calibration, diagnostics can account for the uncertainty due to model fitness, data noise, and the observability of any given parameter. However, Bayesian calibration in Li-ion batteries using electrochemical data is computationally intensive even when using a fast surrogate in place of physics-based models, requiring many thousands of model evaluations. A fully amortized alternative is neural posterior estimation (NPE). NPE shifts the computational burden from the parameter estimation step to data generation and model training, reducing the parameter estimation time from minutes to milliseconds, enabling real-time applications. The present work shows that NPE can infer parameters equally or more accurately than Bayesian calibration, even if it leads to higher voltage reconstruction errors. We also demonstrate that the higher computational costs for data generation are tractable even in high-dimensional cases (ranging from 6 to 27 estimated parameters). The NPE method also offers several interpretability advantages over Bayesian calibration, such as local parameter sensitivity to specific regions of the voltage curve. The NPE method is demonstrated using an experimental fast charge dataset, with parameter estimates validated against measurements of loss of lithium inventory and loss of active material. The implementation is made available in a companion repository (https://github.com/NatLabRockies/BatFIT).

25 ENERGY STORAGE↗

A Method to Estimate Mean Position, Motion Magnitude, Motion Correlation, and Trajectory of a Tumor From Cone-Beam CT Projections for Image-Guided Radiotherapy

Purpose: To develop a probability-based method for estimating the mean position, motion magnitude, and trajectory of a tumor using cone-beam CT (CBCT) projections. Method and Materials: CBCT acquisition was simulated for more than 80 hours of patient-measured trajectories for thoracic/abdominal tumors and prostate. The trajectories were divided into 60-second segments for which CBCT was simulated by projecting the tumor position onto a rotating imager. Tumor (surrogate) visibility on all projections was assumed. The mean and standard deviation of the tumor position and motion correlation along the three axes were determined with maximum likelihood estimation based on the projection data, assuming a Gaussian spatial distribution. The unknown position component along the imager axis was approximated by its expectation value, determined by the Gaussian distribution. Transformation of the resulting three-dimensional position to patient coordinates provided the estimated trajectory. Two trajectories were experimentally investigated by CBCT acquisition of a phantom. Results: The root-mean-square error of the estimated mean position was 0.05 mm. The root-mean-square error of the trajectories was <1 mm in 99.1% of the thorax/abdomen cases and in 99.7% of the prostate cases. The experimental trajectory estimation agreed with the actual phantom trajectory within 0.44 mm in any direction. Clinical applicability was demonstrated by estimating the tumor trajectory for a pancreas cancer case. Conclusions: A method for estimation of mean position, motion magnitude, and trajectory of a tumor from CBCT projections has been developed. The accuracy was typically much better than 1 mm. The method is applicable to motion-inclusive, respiratory-gated, and tumor-tracking radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lattice constant prediction of defective rare earth titanate perovskites

Engineering defective structures in an attempt to modify properties is an established technique in materials chemistry, yet, no models exist which can predict the structure of perovskite compounds containing extrinsic point defects such as vacancies. An empirically derived predictive model, based solely on chemical composition and published ionic radii has been developed. Effective vacancy sizes were derived both empirically from an existing model for pseudocubic lattice-constants, as well as experimentally, from average bond lengths calculated from neutron diffraction data. Compounds of lanthanum-doped barium titanate and strontium-doped magnesium titanate were synthesized with vacancies engineered on the A and B sites. Effective vacancy sizes were then used in empirical models to predict changes in lattice constants. Experimentally refined bond lengths used in the derivation of an effective vacancy size seemed to overestimate the effect of the point defects. Conversely, using calculated vacancy sizes, derived from a previously reported predictive model, showed significant improvements in the prediction of the pseudocubic perovskite lattice. - Graphical abstract: Atomistic model of Sr{sub 0.3}Nd{sub 0.7}Mg{sub 0.35}Ti{sub 0.65}O{sub 3} and Rietveld refinement of neutron diffraction data. - Highlights: • Defective perovskites were synthesized using the organic steric entrapment method. • Oxygen tilt systems were solved through X-ray, electron, and neutron diffraction. • An effective vacancy size for the cations was calculated from experimental bond lengths. • Discrepancies between Shannon radii and experimental measurements are explored. • An empirical model for predicting a{sub pc}, with an absolute error of 0.20%, was developed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

The declared linear density of 238 U and 235 U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar - Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of 235 U (the response) in order to estimate model parameters of the nonlinear Parte equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This article compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. Here, we find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analyzing the Radiation Properties of High-Z Impurities in High-Temperature Plasmas

Most tokamak-based reactor concepts require the use of noble gases to form either a radiative mantle or divertor to reduce conductive heat exhaust to tolerable levels for plasma facing components. Predicting the power loss necessary from impurity radiation is done using electron temperature-dependent 'cooling-curves' derived from ab initio atomic physics models. We present here a technique to verify such modeling using highly radiative, argon infused discharges on Alcator C-Mod. A novel x-ray crystal imaging spectrometer is used to measure spatially resolved profiles of line-emissivity, constraining impurity transport simulations. Experimental data from soft x-ray diodes, bare AXUV diodes and foil bolometers are used to determine the local emissivity in three overlapping spectral bands, which are quantitatively compared to models. Comparison of broadband measurements show agreement between experiment and modeling in the core, but not over the entire profile, with the differences likely due to errors in the assumed radial impurity transport outside of the core. Comparison of Ar{sup 16+} x-ray line emission modeling to measurements suggests an additional problem with the collisional-radiative modeling of that charge state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extending the limits of powder diffraction analysis: diffraction parameter space, occupancy defects, and atomic form factors

Although the determination of site occupancies is often a major goal in Rietveld refinement studies, the accurate refinement of site occupancies is exceptionally challenging due to the many correlations and systematic errors that have a hidden impact on the final refined occupancy parameters. Through the comparison of results independently obtained from neutron and synchrotron powder diffraction, improved approaches capable of detecting occupancy defects with an exceptional sensitivity of 0.1% (absolute) in the class of layered NMC Li-ion battery cathode materials have been developed. A new method of visualizing the diffraction parameter space associated with crystallographic site scattering power through the use of f* diagrams is described and this method is broadly applicable to ternary compounds. The f* diagrams allow the global minimum fit to be easily identified and also permit a robust determination of the number and type of occupancy defects within a structure. Through a comparison of neutron and X-ray diffraction results, a systematic error in the synchrotron results was identified using f* diagrams for a series of NMC compounds. Using neutron diffraction data as a reference, this error was shown to specifically result from problems associated with the neutral oxygen X-ray atomic form factor and could be eliminated by using the ionic O 2- form factor for this anion while retaining the neutral form factors for cationic species. The f* diagram method offers a new opportunity to experimentally assess the quality of atomic form factors through powder diffraction studies on chemically related multi-component compounds.

25 ENERGY STORAGE↗

Subsampling of Parametric Models with Bifidelity Boosting

Least squares regression is a ubiquitous tool for building emulators (a.k.a. surrogate models) of problems across science and engineering for purposes such as design space exploration and uncertainty quantification. When the regression data are generated using an experimental design process (e.g., a quadrature grid) involving computationally expensive models, or when the data size is large, sketching techniques have shown promise at reducing the cost of the construction of the regression model while ensuring accuracy comparable to that of the full data. However, random sketching strategies, such as those based on leverage scores, lead to regression errors that are random and may exhibit large variability. To mitigate this issue, we present a novel boosting approach that leverages cheaper, lower-fidelity data of the problem at hand to identify the best sketch among a set of candidate sketches. This in turn specifies the sketch of the intended high-fidelity model and the associated data. We provide theoretical analyses of this bifidelity boosting (BFB) approach and discuss the conditions the low- and high-fidelity data must satisfy for a successful boosting. In doing so, we derive a bound on the residual norm of the BFB sketched solution relating it to its ideal, but computationally expensive, high-fidelity boosted counterpart. Finally, empirical results on both manufactured and PDE data corroborate the theoretical analyses and illustrate the efficacy of the BFB solution in reducing the regression error, as compared to the nonboosted solution.

97 MATHEMATICS AND COMPUTING↗

Muon g-2: An Interplay between Beam Dynamics and a Muon Decay Experiment at the Precision Frontier

The Muon g-2 Experiment at Fermilab (E989) will use the higher proton flux delivered by the Fermilab accelerator complex and improvements to the experimental apparatus to measure the anomalous magnetic moment of the muon to unprecedented precision. In addition to the increased statistics beyond the most recent measurement, the experiment relies on detailed understanding of the beam dynamics in the experiment’s storage ring as well as the incoming muon beam properties for proper assessments of systematic errors in the data analysis. Modeling and measurements of beam and storage ring properties, from proton targeting to muon storage, produce a unique unification of particle beam physics with a high energy physics experiment. Here the beam dynamics issues and analysis techniques essential to the g-2 experiment are presented and discussed.

43 PARTICLE ACCELERATORS↗

Development of an Improved RELAP5-3D Model for the High Temperature Test Facility

High-temperature gas-cooled reactors (HTGRs) are rapidly approaching deployment. Confidence in transient analysis of these systems for design, optimization, and licensing calculations requires modeling and simulation tools that have been validated against data relevant to HTGR conditions. The High Temperature Test Facility (HTTF) is an integral effects thermal hydraulics test facility for prismatic HTGRs. In spring and summer of 2019, HTTF was used for a series of experiments that now serve as the basis for the OECD/NEA Thermal Hydraulic Code Validation Benchmark for High Temperature Gas-Cooled Reactors using HTTF Data (HTGR T/H Benchmark). This benchmark contains problems for systems code, computational fluid dynamics (CFD), and coupled systems code/CFD modeling representing lower plenum mixing and both the depressurized and pressurized conduction cooldown (DCC and PCC respectively) transients. Benchmark problems include exercises for code-to-code and code-to-data comparisons as well as an exercise for error scaling between HTTF and the Modular High Temperature Gas-Cooled Reactor, which serves as the basis for the HTTF design. Previous analysis as part of the HTGR T/H benchmark used a RELAP5-3D model developed at Idaho National Laboratory (INL) and demonstrated an ability to reproduce trends in the measured data but difficulties reproducing experimental values within their uncertainty. These difficulties were largely attributed to assumptions made during the development of the initial RELAP5-3D model, which predated the HTTF experiments. A significant cause of difficulty reproducing the measured temperatures may be the radial nodalization of the previous RELAP5-3D model. The new model provides a finer nodalization to assess the impact of radial nodalization and allows for asymmetric heating within the core, which was a feature of multiple HTTF experiments. In this paper, we present the new RELAP5-3D model of HTTF. In addition to describing the new model, this paper compares the new and old models and provides results for a full-power steady state, a DCC, and a PCC in HTTF. These analyses are based on the code-to-code comparison exercises for the DCC and PCC problems of the HTGR T/H benchmark. We present the results of these exercises from the new model and compare them to the results of the old model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Viscosity of Heterogeneous Silicate Melts: A Non-Newtonian Model

The recently published viscosity data of heterogeneous silicate melts with well-documented structure and experimental conditions are critically re-analyzed and tabulated. By using these data, a non-Newtonian viscosity model incorporating solid fraction, solid shape, and shear rate is proposed on the basis of the power-law equation. This model allows calculating the viscosity of the heterogeneous silicate melts with solid fraction up to 34 vol pct. The error between the calculated and measured data is evaluated to be 32 pct, which is acceptable considering the large error in viscosity measurement of the completely liquid silicate melt.

36 MATERIALS SCIENCE↗

Electron scattering from argon: Data evaluation and consistency

The demand for coherent scattering data for modeling electron transport in matter has increased in recent years. While much effort has been devoted to the improvement of models describing electron transport and scattering, the updating of fundamental data sets on the basis of recent experimental results has often been neglected. The use of a well-validated set of electron cross sections ensures accurate calculations of transport parameters and ionization yields, with typical applications in material analysis, detector response studies, plasma diagnostics, physics of the atmosphere, and radiotherapy. Data consistency can be verified on the basis of various theoretical requirements, and systematic errors can be minimized by cross-checking results obtained from independent experiments. For example, the oscillator strength distribution of an atom can be obtained both from photoabsorption experiments and from zero-angle electron-atom collisions at high energy, on the basis of the Bethe theory. A considerable number of all electron-scattering experiments are concerned with light noble gases, in particular with argon. This gas is a dominant constituent of noble-gas discharge plasmas and plays an important role in rare-gas halide lasers and proportional scintillator counters. This work reviews electron-scattering cross sections and optical data for the argon atom, discusses the progress made in the field of electron scattering and photoabsorption, and focuses on the most appropriate criteria for verifying data consistency.

74 ATOMIC AND MOLECULAR PHYSICS↗

Enrichment Meter Dataset from High-Resolution Gamma Spectroscopy Measurements of U3O8 Enrichment Standards and UF6 Cylinder Wall Equivalents

The Enrichment Meter Principle (EMP) is the basis for a commonly used standard test method for the non-destructive assay of 235 U enrichment in bulk compounds [1]. The technique involves determining the net count rate in the direct 186 keV peak using medium or high energy gamma-ray spectrometry in a fixed geometry. With suitable correction for wall attenuation, compound type, rate loss (live time), and peaked background (if significant), the atom fraction of 235 U may be obtained from the counting rate from a linear relationship through the origin. The widespread use of this method for field verification of enrichment [2,3] together with the fact that the response function rests on fundamental physics considerations (i.e., is not represented by a convenient but arbitrary form) makes it an interesting example of uncertainty quantification, one in which one can expect a valid measurement model can be applied. When applied using NaI(Tl) and region of interest analysis, the technique is susceptible to both interference error and bias [2-4]. When implemented using high-resolution gamma-ray spectroscopy, the spectrum interpretation is considerable simplified and more robust [5]. However, a practical challenge to studying the uncertainty budget of the EMP method (for example, to test linearity, extract wall corrections and so forth using modern methods) is the availability of quality experimental data that can be referenced and shared. To fill this gap, the research team undertook an experimental campaign [6]. A measurement campaign was conducted to produce high-resolution gamma spectroscopy enrichment meter data comparable to UF 6 cylinder measurements. The purpose of this report is to provide both an introduction to and quality assurance (QA) of the raw data produced. This report is intended for the analyst or researcher who uses the raw data. Unfortunately, the raw data (i.e., the spectra files) are too voluminous to include in this report but can be requested from Steven Croft of the Safeguards & Security Technology Group (scroft@ornl.gov 865-241-2834). The complete processed data are tabulated in Appendix A. The analysis techniques used to produce the QA data presented in this report [e.g., three regions-ofinterest (ROI) peak extraction and batch analysis processes] are not the most sophisticated techniques available; analysts are encouraged to reanalyze the raw data using more sensitive techniques and to improve upon the results presented here. With that being said, the analysis techniques used here are more than adequate to present and inspect the quality of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗