eV Hubble scale inflation with a radiative plateau: Very light inflaton, reheating, and dark matter in B − L extensions
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Currently in the United States, periodic sensor recalibration is required for all safety-related sensors, typically occurring at every refueling outage, and it has emerged as a critical path item for shortening outage duration in some plants. International application of calibration monitoring has shown that sensors may operate for longer periods within calibration tolerances. This issue is expected to also be important as the United States looks to the next generation of reactor designs (such as small modular reactors and advanced concepts), given the anticipated longer refueling cycles, proposed advanced sensors, and digital instrumentation and control systems. Online monitoring (OLM) can be employed to identify those sensors that require calibration, allowing for calibration of only those sensors that need it. The U.S. Nuclear Regulatory Commission (NRC) accepted the general concept of OLM for sensor calibration monitoring in 2000, but no U.S. plants have been granted the necessary license amendment to apply it. This paper summarizes a recent state-of-the-art assessment of online calibration monitoring in the nuclear power industry, including sensors, calibration practice, and OLM algorithms. This assessment identifies key research needs and gaps that prohibit integration of the NRC-approved online calibration monitoring system in the U.S. nuclear industry. Several technical needs were identified, including an understanding of the impacts of sensor degradation on measurements for both conventional and emerging sensors; the quantification of uncertainty in online calibration assessment; determination of calibration acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and assessment of the feasibility of using virtual sensor estimates to replace identified faulty sensors in order to extend operation to the next convenient maintenance opportunity.
A method of elimination of silicon compounds from the anode wire of an aged proportional counter is presented. The aging of a counter with a 70%Ar + 30%CO{sub 2} and a 60%Ar + 30%CO{sub 2} + 10%СF{sub 4} working mixture was stimulated by a {sup 90}Sr β source. To accelerate the process of aging, the gas mixture flow to the counter was supplied through a pipe with RTV coated wall. As a result, the amplitude of the signal decreased 70% already at accumulated charge of Q = 0.03 C/cm. The etching of the silicon compounds on the wire surface with an 80%CF{sub 4} + 20%CO{sub 2} gas mixture discharge led to full recovery of the operating characteristics of detector and an increase in the lifetime. A scanning electron microscopy and X-ray spectroscopy analysis of the recovered wire surface were performed. In accordance with the results, a good quality of wire cleaning from SiO{sub 2} compounds was obtained.
The method of searching for showers generated by neutral particles such as high-energy gamma quanta and astrophysical neutrinos is described, and the results of this search are presented. These results were obtained in the combined analysis of data on electrons, muons, and Cherenkov radiation of EASs and their temporal responses in scintillation and Cherenkov detectors. An upper limit on the flux of gamma quanta with energies of 3 × 10{sup 1}8, 10{sup 1}9, and 3 × 10{sup 1}9 eV was obtained. The multiparameter analysis of shower characteristics did not reveal EASs produced by neutrinos.
In FY-2015, The development of MOOSE was driven by the needs of the NEAMS MOOSE-based applications, BISON, MARMOT, and RELAP-7. An emphasis was placed on the continued upkeep and improvement MOOSE in support of the product line integration goals. New unified documentation tools have been developed, several improvements to regression testing have been enforced and overall better software quality practices have been implemented. In addition the Multiapps and Transfers systems have seen significant refactoring and robustness improvements, as has the “Restart and Recover” system in support of Multiapp simulations. Finally, a completely new “Control Logic” system has been engineered to replace the prototype system currently in use in the RELAP-7 code. The development of this system continues and is expected to handle existing needs as well as support future enhancements.
The IMMPE project, DE-FE0032284, was to enhance methane monitoring technologies and their applications across various natural gas asset classes. The scope included deploying advanced methane detection and monitoring technologies to identify and mitigate fugitive methane emissions, measuring emission rates, and assessing impacts. The findings included the successful mitigation of identified emissions and quantification of emission rates. A key outcome was the development of a comprehensive template and summary of recommendations for methane emissions monitoring, which is replicable for both upstream and downstream applications. Furthermore, the project emphasized the importance of education by providing training opportunities for technicians and regulators, thereby fostering awareness and promoting the adoption of cost-effective methane emissions monitoring and management techniques.
We demonstrate that we could scale FEA to reach outputs needed by industrial production, while increasing solids loading of the sprayed product by at least 30% and maintaining equal or better spray powder. After testing a wide range of products, in collaboration with industry partners we decided on our primary spray products of dry whey and WPC-80, two common materials processed and sold by US manufacturers with different parameters. We sprayed these with FEA at solids loadings of 70% for dry whey and 45% for WPC-80 with a spray output with particle sizes similar to industrial particles sizes and reduced variation in particle size. We simultaneously scaled up FEA first with a multi-nip with 6 nips surrounding a central roller with parallel axis of rotation and eventually with a tapered design that solved problems we encountered with our initial design. We were able to achieve output from a single array from our first design of up to 4.7 liters per minute (L/min) and from an array of our second multi-nip of 8 L/min exceeding expectations. This demonstrates that FEA technology can indeed be scaled up to meet the needs of industrial production. More arrays can be added as necessary to meet a wide range of spray dryer designs. We also tested FEA to create dried powders from a small scale (10 L/hour of water removal) spray dryer. Though we were not able to produce large quantities of powder from FEA due to challenges in integration, the powder we produced was higher quality and produced from higher solids loading materials. From our technoeconomic analysis we for a typically sized spray dryer, we estimate a 27% cost reduction and 41% energy and carbon reduction for WPC-80 and a 39-57% cost reduction and 52-76% energy reduction for sweet dry whey (depending on the exact product).
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
U.S. national and regional emissions of HFC-134a are derived for 2008-2012 based on atmospheric observations from ground and aircraft sites across the U.S. and a newly developed regional inverse model. Synthetic data experiments were first conducted to optimize the model assimilation design and to assess model-data mismatch errors and prior flux error covariances computed using a maximumlikelihood estimation technique. The synthetic data experiments also tested the sensitivity of derived national and regional emissions to a range of assumed prior emissions, with the goal of designing a system that was minimally reliant on the prior. We then explored the influence of additional sources of error in inversions with actual observations, such as those associated with background mole fractions and transport uncertainties. Estimated emissions of HFC-134a range from 52 to 61 Gg yr -1 for the contiguous U.S. during 2008-2012 for inversions using air transport from Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model driven by the 12km resolution meteorogical data from North American Mesoscale Forecast System (NAM12) and all tested combinations of prior emissions and background mole fractions. Estimated emissions for 2008-2010 were 20% lower when specifying alternative transport from Stochastic Time-Inverted Lagrangian Transport (STILT) model driven by the Weather Research and Forecasting (WRF) meteorology. Our estimates (for HYSPLIT-NAM12) are consistent with annual emissions reported by U.S. Environmental Protection Agency for the full study interval. The results suggest a 10-20% drop in U.S. national HFC-134a emission in 2009 coincident with a reduction in transportation-related fossil fuel CO 2 emissions, perhaps related to the economic recession. All inversions show seasonal variation in national HFC-134a emissions in all years, with summer emissions greater than winter emissions by 20-50%.
Not Available
Plutonium(IV) oxide nanoclusters represent an interesting scientific problem regarding structure-function relationships and are also relevant to global concerns surrounding plutonium reprocessing, the remediation of plutonium-contaminated soils, and the storage or disposal of plutonium-containing wastes. Here we report the synthesis of five unique Pu IV oxide nanoclusters containing 38,22, or 16 metal centers and capped only with inorganic ligands, such as chlorine and water, which prevent formation of the extended PuO 2 structure. The products are interrogated through single-crystal X-ray diffraction, bond valence calculations, and comparisons to other known metal-oxide nanoclusters. Of particular interest is the in-corporation of hydroxide linkages into the smaller plutonium oxide nanoclusters, which underscores previous observations and hypotheses regarding the formation of plutonium polymers and colloids.
In this paper we clarify that our weathering model from 2013 did not explicitly describe weathering of soil moving downhill along hillslopes. Additionally, we re-analyze the role of the term that we neglected that describes loss of regolith mass through mineral dissolution. We derive an equation for this term by including lateral flow of water inside the model hill. For the revised hill model, we define a dimensionless parameter that allows estimation of the effect of lateral flow on the steady-state hillslope. This parameter is equal to the ratio of averaged advective flux of dissolved species out of the hill to the rate of total denudation. The parameter also yields a criterion for the existence of a steady state regolith thickness for systems experiencing unidirectional advection at a constant velocity: for a ridge, the rate of downward flow of water (qy) must be less than the rate of upward movement of rock (E) after normalization by a small parameter, α. This parameter is equal to the equilibrium aqueous concentration divided by the concentration of the reacting mineral in the rock. Alternately, a steady state may exist for the case of both vertical and lateral flow in a hill for any value of erosion rate if the Darcy velocities decrease with depth. Subsurface flow systems play an essential role in the existence of both steady-state hillslopes and steady-state regolith thicknesses.
Abstract Dicentric chromosome assay (DCA) is routinely used for estimating the absorbed radiation dose in exposed humans. Optimal lymphocyte viability is crucial for reliable dose estimation and most cytogenetic laboratories prefer the receipt of blood samples within 24 to 36 hours after collection. Delays in the shipment/receipt of samples can occur sometimes under certain unforeseen circumstances: (1) Adverse weather conditions, (2) distant location of blood collection sites, and (3) shipping and handling of a large number of samples after radiological/nuclear mass casualty incident(s). To circumvent some of these limitations, we evaluated the suitability of ex vivo irradiated blood samples stored in the presence of phytohemagglutinin (PHA) for 7 days at ambient temperature (22‐24°C) for radiation biodosimetry. Blood samples stored in the presence of PHA for up to 7 days showed a higher mitotic index than blood samples stored without PHA. To verify the use of stored blood samples for DCA, frequencies of X‐rays induced dicentric chromosomes were analyzed in the blood samples that were cultured either 24 hours after exposure or 7 days later after storage. Our results indicate that storage of ex vivo irradiated blood samples in the presence of PHA at ambient temperature was found optimal for DCA and that the radiation doses estimated by dicentric chromosome frequencies were grossly similar between the fresh and stored blood samples. Our study suggests that reliable and accurate biodosimetry results can be obtained for triage using blood samples stored for up to a week at ambient temperature in the presence of PHA.