Search NASA⌕ Search

SEARCH · Search NASA

Results for “false data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Robust automatic rigid registration of MRI and X-ray using external fiducial markers for XFM-guided interventional procedures

Purpose: In X-ray fused with MRI, previously gathered roadmap MRI volume images are overlaid on live X-ray fluoroscopy images to help guide the clinician during an interventional procedure. The incorporation of MRI data allows for the visualization of soft tissue that is poorly visualized under X-ray. The widespread clinical use of this technique will require fully automating as many components as possible. While previous use of this method has required time-consuming manual intervention to register the two modalities, in this article, the authors present a fully automatic rigid-body registration method. Methods: External fiducial markers that are visible under these two complimentary imaging modalities were used to register the X-ray images with the roadmap MR images. The method has three components: (a) The identification of the 3D locations of the markers from a full 3D MR volume, (b) the identification of the 3D locations of the markers from a small number of 2D X-ray fluoroscopy images, and (c) finding the rigid-body transformation that registers the two point sets in the two modalities. For part (a), the localization of the markers from MR data, the MR volume image was thresholded, connected voxels were segmented and labeled, and the centroids of the connected components were computed. For part (b), the X-ray projection images, produced by an image intensifier, were first corrected for distortions. Binary mask images of the markers were created from the distortion-corrected X-ray projection images by applying edge detection, pattern recognition, and image morphological operations. The markers were localized in the X-ray frame using an iterative backprojection-based method which segments voxels in the volume of interest, discards false positives based on the previously computed edge-detected projections, and calculates the locations of the true markers as the centroids of the clusters of voxels that remain. For part (c), a variant of the iterative closest point method was used to find correspondences between and register the two sets of points computed from MR and X-ray data. This knowledge of the correspondence between the two point sets was used to refine, first, the X-ray marker localization and then the total rigid-body registration between modalities. The rigid-body registration was used to overlay the roadmap MR image onto the X-ray fluoroscopy projections. Results: In 35 separate experiments, the markers were correctly registered to each other in 100% of the cases. When half the number of X-ray projections was used (10 X-ray projections instead of 20), the markers were correctly registered in all 35 experiments. The method was also successful in all 35 experiments when the number of markers was (retrospectively) halved (from 16 to 8). The target registration error was computed in a phantom experiment to be less than 2.4 mm. In two in vivo experiments, targets (interventional devices with pointlike metallic structures) inside the heart were successfully registered between the two modalities. Conclusions: The method presented can be used to automatically register a roadmap MR image to X-ray fluoroscopy using fiducial markers and as few as ten X-ray projections.

60 APPLIED LIFE SCIENCES↗

Rocket Launch Detection with Smartphone Audio and Transfer Learning

Rocket launches generate infrasound signatures that have been detected at great distances. Due to the sparsity of the networks that have made these detections, however, most signals are detected tens of minutes to hours after the rocket launch. In this work, a method of near-real-time detection of rocket launches using data from a network of smartphones located 10–70 km from launch sites is presented. A machine learning model is trained and tested on the open-access Aggregated Smartphone Timeseries of Rocket-generated Acoustics (ASTRA), Smartphone High-explosive Audio Recordings Dataset (SHAReD), and ESC-50 datasets, resulting in a final accuracy of 97% and a false positive rate of <1%. The performance and behavior of the model are summarized, and its suitability for persistent monitoring applications is discussed.

acoustics↗

Determination of cellulose crystallinity from powder diffraction diagrams: Powder Diffraction Diagrams

Commonly one-dimensional (1D) (spherically averaged) powder diffraction diagrams are used to determine the degree of cellulose crystallinity in biomass samples. Here, it is shown using molecular modeling how disorder in cellulose fibrils can lead to considerable uncertainty in conclusions drawn concerning crystallinity based on 1D powder diffraction data alone. For example, cellulose microfibrils that contain both crystalline and noncrystalline segments can lead to powder diffraction diagrams lacking identifiable peaks, while microfibrils without any crystalline segments can lead to such peaks. Moreover, this leads to false positives, that is, assigning disordered cellulose as crystalline, and false negatives, that is, categorizing fibrils with crystalline segments as amorphous. Finally, the reliable determination of the fraction of crystallinity in any given biomass sample will require a more sophisticated approach combining detailed experiment and simulation.

36 MATERIALS SCIENCE↗

A Prospective Evaluation of Staging and Target Volume Definition of Lymph Nodes by {sup 18}FDG PET/CT in Patients With Squamous Cell Carcinoma of Thoracic Esophagus

Purpose: To determine an optimal standardized uptake value (SUV) threshold for detecting lymph node (LN) metastases in esophageal cancer using {sup 18}F-Fluorodeoxyglucose positron emission tomography/computer tomography ({sup 18}FDG PET/CT) and to define the resulting nodal target volume, using histopathology as a 'gold standard.' Methods: Sixteen patients with esophageal squamous cell carcinoma who underwent radical esophagectomy and three-field LN dissection after {sup 18}FDG PET/CT and CT scans were enrolled into this study. Locations of LN groups were recorded according to a uniform LN map. Diagnostic performance of different SUV thresholds was assessed by receiver operating characteristic analysis. The optimal cutoff SUV was determined by plotting the false-negative rate (FNR) and false-positive rate (FPR), the sum of both error rates (FNR+FPR), and accuracy against a hypothetical SUV threshold. For each patient, nodal gross tumor volumes (GTVNs) were generated with CT alone (GTVNCT), PET/CT (GTVNPET), and pathologic data (GTVNpath). GTVNCT or GTVNPET was compared with GTVNpath by means of a conformity index (CI), which is the intersection of the two GTVNs divided by the sum of them minus the intersection, e.g., CI{sub CT} and {sub path} = GTVN{sub CT} and {sub path}/(GTVN{sub CT}+ GTVN{sub path} - GTVN{sub CT} and {sub path}). Results: LN metastases occurred in 21 LN groups among the 144 specimens taken from the 16 patients. The area under the receiver operating characteristic curve was 0.9017 {+-} 0.0410. The plot of error rates showed a minimum of FNR+FPR for an SUV of 2.36, at which the sensitivity, specificity, and accuracy were 76.19%, 95.93%, and 93.06%, respectively, whereas those of CT were 33.33%, 94.31%, and 85.42% (p values: 0.0117, 0.7539, and 0.0266). Mean GTVN{sub CT}, GTVN{sub PET}, and GTVN{sub path} were 1.52 {+-} 2.38, 2.82 {+-} 4.51, and 2.68 {+-} 4.16cm{sup 3}, respectively. Mean CI{sub CT} and {sub path} and CI{sub PET} and {sub path} were 0.31 and 0.65 (p value = 0.0352). Conclusions: Diagnostic superiority of PET/CT at an SUV threshold of 2.36 over CT has potential value in nodal target volume definition, but whether this can contribute to better treatment outcomes needs prospective analyses of recurrences in a larger cohort of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A scaling transformation for classifier output based on likelihood ratio: Applications to a CAD workstation for diagnosis of breast cancer

Purpose: The authors developed scaling methods that monotonically transform the output of one classifier to the ''scale'' of another. Such transformations affect the distribution of classifier output while leaving the ROC curve unchanged. In particular, they investigated transformations between radiologists and computer classifiers, with the goal of addressing the problem of comparing and interpreting case-specific values of output from two classifiers. Methods: Using both simulated and radiologists' rating data of breast imaging cases, the authors investigated a likelihood-ratio-scaling transformation, based on ''matching'' classifier likelihood ratios. For comparison, three other scaling transformations were investigated that were based on matching classifier true positive fraction, false positive fraction, or cumulative distribution function, respectively. The authors explored modifying the computer output to reflect the scale of the radiologist, as well as modifying the radiologist's ratings to reflect the scale of the computer. They also evaluated how dataset size affects the transformations. Results: When ROC curves of two classifiers differed substantially, the four transformations were found to be quite different. The likelihood-ratio scaling transformation was found to vary widely from radiologist to radiologist. Similar results were found for the other transformations. Our simulations explored the effect of database sizes on the accuracy of the estimation of our scaling transformations. Conclusions: The likelihood-ratio-scaling transformation that the authors have developed and evaluated was shown to be capable of transforming computer and radiologist outputs to a common scale reliably, thereby allowing the comparison of the computer and radiologist outputs on the basis of a clinically relevant statistic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors [Dissertation]

Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal’s intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-GHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (μm-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor’s architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perót displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.

Engineering(42)↗

Constraints on Neutrino Oscillation Parameters from Neutrinos and Antineutrinos with Machine Learning

NOvA is a two detector, long baseline neutrino oscillation experiment measuring the oscillations of muon neutrinos from the \numi neutrino beam over a baseline of \SI{810}{km}. The experiment uses four oscillation channels, $\numu \rightarrow \numu$, $\numubar \rightarrow \numubar$, $\numu \rightarrow \nue$, and $\numubar \rightarrow \nuebar$, with a peak neutrino energy of \SI{1.8}{GeV}. This dissertation describes the analysis of these channels using a dataset of $13.6\times10^{20}$ protons on target neutrino beam mode and $12.5\times10^{20}$ protons on target antineutrino beam mode. The analysis makes use of improvements in the treatment of systematic uncertainties and machine learning techniques to reconstruct neutrino interactions. A technique for decorrelating systematic errors using principle component analysis was utilized to reduce and optimize neutrino cross section and beam related uncertainties. The improved machine learning algorithms make use of convolutional ne ural net works for neutrino event classification, particle classification, and instance segmentation. The selection of neutrino signal events utilizing the neutrino event classifier shows an efficiency of 63\% for the selection of electron neutrinos in neutrino beam mode and 75\% for electron antineutrinos in antineutrino beam mode. Using this algorithm, 82 appearing electron neutrino candidates and 33 appearing electron antineutrino candidates were observed with expected backgrounds of 26.8 and 14.0 respectively. In addition, 211 surviving muon neutrino candidates and 105 muon antineutrino candidates were identified with a purity of more than 96\% using the same neutrino event classifier. Fitting these data to the three flavor neutrino oscillation model, using constraints on \thetaonetwo, \thetaonethree, and \dmsqonetwo from solar and reactor neutrino experiments, the oscillation parameters are measured to be $\sintwothree = 0.57^{+0.04}_{-0.03}$, $\dmsqthreetwo = \SI[parse-numbers= false]{+ 2.41\pm0.07 \times 10^{-3}}{eV^2}$, and $\dcp=0.82^{+0.27}_{-0.87}\pi$ with a preference for the normal neutrino mass hierarchy. Leading systematic uncertainties for these measurements come from detector calibration and neutrino interaction models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Deeper Look at DES Dwarf Galaxy Candidates: Grus i and Indus ii

We present deep g- and r-band Magellan/Megacam photometry of two dwarf galaxy candidates discovered in the Dark Energy Survey (DES), Grus i and Indus ii (DES J2038–4609). For the case of Grus i, we resolved the main sequence turn-off (MSTO) and ~2 mags below it. The MSTO can be seen at g 0 ~24 with a photometric uncertainty of 0.03 mag. We show Grus i to be consistent with an old, metal-poor (~13.3 Gyr, [Fe/H] ~ -1.9) dwarf galaxy. We derive updated distance and structural parameters for Grus i using this deep, uniform, wide-field data set. We find an azimuthally-averaged halflight radius more than two times larger (~151 +21 -31 pc; ~$4\buildrel{\,\prime}\over{.} {16}_{-0.74}^{+0.54}$) and an absolute V-band magnitude ~-4.1 that is ~1 magnitude brighter than previous studies. We obtain updated distance, ellipticity, and centroid parameters that are in agreement with other studies within uncertainties. Although our photometry of Indus ii is ~2–3 magnitudes deeper than the DES Y1 public release, we find no coherent stellar population at its reported location. The original detection was located in an incomplete region of sky in the DES Y2Q1 data set and was flagged due to potential blue horizontal branch member stars. The best-fit isochrone parameters are physically inconsistent with both dwarf galaxies and globular clusters. We conclude that Indus ii is likely a false positive, flagged due to a chance alignment of stars along the line of sight.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimum frame synchronization for biorthogonally coded data

Many recent American unmanned planetary probes have used biorthogonally coded spacecraft-to-earth telemetry links. An examination of the frame-synchronization (sync) techniques employed on these missions revealed that they were not specifically designed for coded data. This led to a consideration of the optimum frame-sync problem for biorthogonally coded data received over the additive white Gaussian noise (AWGN) channel and decoded prior to sync acquisition. A frame-sync algorithm for biorthogonally coded data based on a super-symbol distance rule is proposed, along with a corresponding selection criterion for the sync sequence. It is argued heuristically that this approach is optimum with regard to minimizing the probability of false synchronization.

Levitt, B. K.↗

Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment - STS-35 and STS-40 preliminary results

Preliminary results from the STS-35 and STS-40 flight of the Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment aboard the Shuttle Orbiter Columbia are presented. Infrared images are shown in false-color indicating the level and distribution of surface temperature over the vehicle's leeside fuselage during entry. Features evident in the imagery are related to their causative aerodynamic flow phenomena. Quantitative comparisons of the infrared image data with in situ temperature measurements obtained with thermocouples located at the aerodynamic surface of the thermal protection materials are presented.

Throckmorton, David A.↗

Automated Point Cloud Correspondence Detection for Underwater Mapping Using AUVs

An algorithm for automating correspondence detection between point clouds composed of multibeam sonar data is presented. This allows accurate initialization for point cloud alignment techniques even in cases where accurate inertial navigation is not available, such as iceberg profiling or vehicles with low-grade inertial navigation systems. Techniques from computer vision literature are used to extract, label, and match keypoints between "pseudo-images" generated from these point clouds. Image matches are refined using RANSAC and information about the vehicle trajectory. The resulting correspondences can be used to initialize an iterative closest point (ICP) registration algorithm to estimate accumulated navigation error and aid in the creation of accurate, self-consistent maps. The results presented use multibeam sonar data obtained from multiple overlapping passes of an underwater canyon in Monterey Bay, California. Using strict matching criteria, the method detects 23 between-swath correspondence events in a set of 155 pseudo-images with zero false positives. Using less conservative matching criteria doubles the number of matches but introduces several false positive matches as well. Heuristics based on known vehicle trajectory information are used to eliminate these.

Sonar↗

Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors

Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal's intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-MHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (?m-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor's architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perot displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.

42 ENGINEERING↗

Thermal Management and Thermal Protection Systems

During my internship in the Thermal Design Branch (ES3), I contributed to two main projects: i) novel passive thermal management system for future human exploration, ii) AVCOAT undercut thermal analysis. i) As NASA prepares to further expand human and robotic presence in space, it is well known that spacecraft architectures will be challenged with unprecedented thermal environments. Future exploration activities will have the need of thermal management systems that can provide higher reliability, mass and power reduction and increased performance. In an effort to start addressing the current technical gaps the NASA Johnson Space Center Passive Thermal Discipline has engaged in technology development activities. One of these activities was done through an in-house Passive Thermal Management System (PTMS) design for a lunar lander. The proposed PTMS, functional in both microgravity and gravity environments, consists of three main components: a heat spreader, a novel hybrid wick Variable Conductance Heat Pipe (VCHP), and a radiator. The aim of this PTMS is to keep electronics on a vehicle within their temperature limits (0 and 50 C for the current design) during all mission phases including multiple lunar day/night cycles. The VCHP was tested to verify its thermal performance. I created a thermal math model using Thermal Desktop (TD) and analyzed it to predict the PTMS performance. After testing, the test data provided a means to correlate the thermal math model. This correlation took into account conduction and convection heat transfer, representing the actual benchtop test. Since this PTMS is proposed for space missions, a vacuum test will be taking place to provide confidence that the system is functional in space environments. Therefore, the model was modified to include a vacuum chamber with a liquid nitrogen shroud while taking into account conduction and radiation heat transfer. Infrared Lamps were modelled and introduced into the model to simulate the sun's rays directly impinging on the system. Heating rate of the lamps were calculated by knowing fraction of emitted energy in a wavelength interval and the filament temperature. This version of the model can be used to predict performance of the system under vacuum with extreme cold or hot conditions. Initial testing of the PTMS showed promise, and the thermal math model predicts even better performance in thermal vacuum testing. ii) Thermal Protection Systems (TPS) are required for vehicles which enter earth's atmosphere to protect from aerodynamic heating caused by the friction between the vehicle and atmospheric gases. Orion's heat shield design has two aspects which needed to be analyzed thermally: i) a small excess of adhesive used to bond the outer AVCOAT layer to the inner composite structure tends to seep from under the AVCOAT and form a small bead in between two bricks of AVCOAT, ii) a silicone rubber with different thermophysical properties than AVCOAT fills the gap between two bricks of AVCOAT. I created a thermal model using TD to determine temperature differences that are caused by these two features. To prevent false results, all TD models must be verified against something known. In this case, the TD model was correlated to CHAR, an ablation modelling software used to analyze TPS. Analyzing a node far from the concerning features, we saw that the TD model data match CHAR data, verifying the TD model. Next, the temperature of the silicone rubber as well as the bead of adhesive were analyzed to determine if they exceeded allowable temperatures. It was determined that these two features do not have a significant effect on the max temperature of the heat shield. This model can be modified to check temperatures at various locations of the heat shield where the composite thickness varies.

Hasnain, Aqib↗

Evaluation of PCR Systems for Field Screening of Bacillus anthracis

There is little published data on the performance of hand-portable polymerase chain reaction (PCR) instruments that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated five commercially available hand-portable PCR instruments for detection of Bacillus anthracis (Ba). We designed a cost-effective, statistically-based test plan that allows instruments to be evaluated at performance levels ranging from 0.85-0.95 lower confidence bound (LCB) on the probability of detection (POD) at confidence levels of 80-95%. We assessed specificity using purified genomic DNA from 13 Ba strains and 18 Bacillus near neighbors, interference with 22 common hoax powders encountered in the field, and PCR inhibition when Ba spores were spiked into these powders. Our results indicated that three of the five instruments achieved >0.95 LCB on the POD with 95% confidence at test concentrations of 2,000 genome equivalents/mL (comparable to 2,000 spores/mL), displaying more than sufficient sensitivity for screening suspicious powders. These instruments exhibited no false positive results or PCR inhibition with common hoax powders, and reliably detected Ba spores spiked into common hoax powders, though some issues with instrument controls were observed. Our testing approach enables efficient instrument performance testing to a statistically rigorous and cost-effective test plan to generate performance data that will allow users to make informed decisions regarding the purchase and use of biodetection equipment in the field.

59 BASIC BIOLOGICAL SCIENCES↗

SPECKLE CAMERA OBSERVATIONS FOR THE NASA KEPLER MISSION FOLLOW-UP PROGRAM

We present the first results from a speckle imaging survey of stars classified as candidate exoplanet host stars discovered by the Kepler mission. We use speckle imaging to search for faint companions or closely aligned background stars that could contribute flux to the Kepler light curves of their brighter neighbors. Background stars are expected to contribute significantly to the pool of false positive candidate transiting exoplanets discovered by the Kepler mission, especially in the case that the faint neighbors are eclipsing binary stars. Here, we describe our Kepler follow-up observing program, the speckle imaging camera used, our data reduction, and astrometric and photometric performance. Kepler stars range from R = 8 to 16 and our observations attempt to provide background non-detection limits 5-6 mag fainter and binary separations of {approx}0.05-2.0 arcsec. We present data describing the relative brightness, separation, and position angles for secondary sources, as well as relative plate limits for non-detection of faint nearby stars around each of 156 target stars. Faint neighbors were found near 10 of the stars.

79 ASTRONOMY AND ASTROPHYSICS↗

IDENTIFICATIONS AND PHOTOMETRIC REDSHIFTS OF THE 2 Ms CHANDRA DEEP FIELD-SOUTH SOURCES

We present reliable multiwavelength identifications and high-quality photometric redshifts for the 462 X-ray sources in the {approx}2 Ms Chandra Deep Field-South (CDF-S) survey. Source identifications are carried out using deep optical-to-radio multiwavelength catalogs, and are then combined to create lists of primary and secondary counterparts for the X-ray sources. We identified reliable counterparts for 442 (95.7%) of the X-ray sources, with an expected false-match probability of {approx} 6.2%; we also selected four additional likely counterparts. The majority of the other 16 X-ray sources appear to be off-nuclear sources, sources associated with galaxy groups and clusters, high-redshift active galactic nuclei (AGNs), or spurious X-ray sources. A likelihood-ratio method is used for source matching, which effectively reduces the false-match probability at faint magnitudes compared to a simple error-circle matching method. We construct a master photometric catalog for the identified X-ray sources including up to 42 bands of UV-to-infrared data, and then calculate their photometric redshifts (photo-z's). High accuracy in the derived photo-z's is accomplished owing to (1) the up-to-date photometric data covering the full spectral energy distributions (SEDs) of the X-ray sources, (2) more accurate photometric data as a result of source deblending for {approx}10% of the sources in the infrared bands and a few percent in the optical and near-infrared bands, (3) a set of 265 galaxy, AGN, and galaxy/AGN hybrid templates carefully constructed to best represent all possible SEDs, (4) the Zurich Extragalactic Bayesian Redshift Analyzer used to derive the photo-z's, which corrects the SED templates to best represent the SEDs of real sources at different redshifts and thus improves the photo-z quality. The reliability of the photo-z's is evaluated using the subsample of 220 sources with secure spectroscopic redshifts. We achieve an accuracy of |{delta}z|/(1 + z) {approx} 1% and an outlier [with |{delta}z|/(1 + z)>0.15] fraction of {approx}1.4% for sources with spectroscopic redshifts. We performed blind tests to derive a more realistic estimate of the photo-z quality for sources without spectroscopic redshifts. We expect there are {approx}9% outliers for the relatively brighter sources (R {approx}< 26), and the outlier fraction will increase to {approx}15%-25% for the fainter sources (R {approx}> 26). The typical photo-z accuracy is {approx}6%-7%. The outlier fraction and photo-z accuracy do not appear to have a redshift dependence (for z {approx} 0-4). These photo-z's appear to be the best obtained so far for faint X-ray sources, and they have been significantly ({approx}>50%) improved compared to previous estimates of the photo-z's for the X-ray sources in the {approx}2 Ms Chandra Deep Field-North and {approx}1 Ms CDF-S.

79 ASTRONOMY AND ASTROPHYSICS↗

Sex and age differences in the expression of liver microRNAs during the life span of F344 rats

Background: Physiological factors such as age and sex have been shown to be risk factors for adverse effects in the liver, including liver diseases and drug-induced liver injury. Previously, we have reported age- and sex-related significant differences in hepatic basal gene expression in rats during the life span that may be related to susceptibility to such adverse effects. However, the underlying mechanisms of the gene expression changes were not fully understood. In recent years, increasing evidence for epigenetic mechanisms of gene regulation has fueled interest in the role of microRNAs (miRNAs) in toxicogenomics and biomarker discovery. We therefore proposed that significant age and sex differences exist in baseline liver miRNA expression, and that comprehensive profiling of miRNAs will provide insights into the epigenetic regulation of gene expression in rat liver. Methods: To address this, liver tissues from male and female F344 rats were examined at 2, 5, 6, 8, 15, 21, 52, 78, and 104 weeks of age for the expression of 677 unique miRNAs. Following data processing, predictive pathway analysis was performed on selected miRNAs that exhibited prominent age and/or sex differences in expression. Results: Of the 314 miRNAs found to be expressed, 214 were differentially expressed; 65 and 212 miRNAs showed significant (false discovery rate (FDR) <5% and ≥1.5-fold change) sex- and age-related differences in expression, respectively. Thirty-eight miRNAs showed 2-week-specific expression, of which 31 miRNAs were found to be encoded within the Dlk1-Dio3 cluster located on chromosome 6. This cluster has been associated with tissue proliferation and differentiation, and liver energy homeostasis in postnatal development. Predictive pathway analysis linked sex-biased miRNA expression with sexually dimorphic molecular functions and toxicological functions that may reflect sex differences in hepatic physiology and disease. The expression of miRNAs (miR-18a, miR-99a, and miR-203, miR-451) was also found to associate with specific sexually dimorphic hepatic histopathology. The expression of miRNAs involved in regulating cell death, cell proliferation, and cell cycle was found to change as the rats matured from adult to old age. Conclusions: Overall, significant age- and sex-related differences in liver miRNA expression were identified and linked to histopathological findings and predicted functional pathways that may underlie susceptibilities to liver toxicity and disease.

59 BASIC BIOLOGICAL SCIENCES↗

Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment - STS-28 preliminary results

Preliminary results from the STS-28 flight of the Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment aboard the Shuttle Orbiter Columbia are presented. Infrared images are shown in false-color indicating the level and distribution of surface temperature on the leeside of the left wing during entry. Features evident in the imagery are related to their causative aerodynamic flow phenomena. Quantitative comparisons of the infrared image data with in situ temperature measurements obtained with thermocouples located at the aerodynamic surface of the thermal protection system materials are presented.

Throckmorton, David A.↗