Search NASA⌕ Search

SEARCH · Search NASA

Results for “geometry factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Full dimensional Franck-Condon factors for the acetylene A{sup ~} {sup 1}A{sub u}—X{sup ~1}Σ{sup +}{sub g} transition. I. Method for calculating polyatomic linear—bent vibrational intensity factors and evaluation of calculated intensities for the gerade vibrational modes in acetylene

Franck-Condon vibrational overlap integrals for the A{sup ~1}A{sub u}—X{sup ~1}Σ{sup +}{sub g} transition in acetylene have been calculated in full dimension in the harmonic normal mode basis. The calculation uses the method of generating functions first developed for polyatomic Franck-Condon factors by Sharp and Rosenstock [J. Chem. Phys. 41(11), 3453–3463 (1964)], and previously applied to acetylene by Watson [J. Mol. Spectrosc. 207(2), 276–284 (2001)] in a reduced-dimension calculation. Because the transition involves a large change in the equilibrium geometry of the electronic states, two different types of corrections to the coordinate transformation are considered to first order: corrections for axis-switching between the Cartesian molecular frames and corrections for the curvilinear nature of the normal modes at large amplitude. The angular factor in the wave function for the out-of-plane component of the trans bending mode, ν{sub 4}{sup ″}, is treated as a rotation, which results in an Eckart constraint on the polar coordinates of the bending modes. To simplify the calculation, the other degenerate bending mode, ν{sub 5}{sup ″}, is integrated in the Cartesian basis and later transformed to the constrained polar coordinate basis, restoring the conventional v and l quantum numbers. An updated A{sup ~}-state harmonic force field obtained recently in the R. W. Field research group is evaluated. The results for transitions involving the gerade vibrational modes are in qualitative agreement with experiment. Calculated results for transitions involving ungerade modes are presented in Paper II of this series [G. B. Park, J. H. Baraban, and R. W. Field, “Full dimensional Franck–Condon factors for the acetylene A{sup ~1}A{sub u}—X{sup ~1}Σ{sup +}{sub g} transition. II. Vibrational overlap factors for levels involving excitation in ungerade modes,” J. Chem. Phys. 141, 134305 (2014)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space from Hilbert space: Recovering geometry from bulk entanglement

We examine here how to construct a spatial manifold and its geometry from the entanglement structure of an abstract quantum state in Hilbert space. Given a decomposition of Hilbert space H into a tensor product of factors, we consider a class of “redundancy-constrained states” in H that generalize the area-law behavior for entanglement entropy usually found in condensed-matter systems with gapped local Hamiltonians. Using mutual information to define a distance measure on the graph, we employ classical multidimensional scaling to extract the best-fit spatial dimensionality of the emergent geometry. We then show that entanglement perturbations on such emergent geometries naturally give rise to local modifications of spatial curvature which obey a (spatial) analog of Einstein’s equation. The Hilbert space corresponding to a region of flat space is finite-dimensional and scales as the volume, yet the entropy (and the maximum change thereof) scales like the area of the boundary. A version of the ER = EPR conjecture is recovered, in that perturbations that entangle distant parts of the emergent geometry generate a configuration that may be considered as a highly quantum wormhole.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-357: Semi-Automated Knowledge-Based Radiation Therapy (KBRT) Planning for Head-And-Neck Cancer (HNC): Can KBRT Plans Achieve Better Results Than Manual Planning?

Purpose: Knowledge Based Radiation Therapy Treatment (KBRT) planning can be used to semi-automatically generate IMRT plans for new patients using constraints derived from previously manually-planned, geometrically similar patients. We investigate whether KBRT plans can achieve greater dose sparing than manual plans using optimized, organspecific constraint weighting factors. Methods: KBRT planning of HNC radiotherapy cases geometrically matched each new (query) case to one of the 105 clinically approved plans in our database. The dose distribution of the planned match was morphed to fit the querys geometry. Dose-volume constraints extracted from the morphed dose distribution were used to run the IMRT optimization with no user input. In the first version, all constraints were multiplied by a weighting factor of 0.7. The weighting factors were then systematically optimized (in order of OARs with increasing separation from the target) to maximize sparing to each OAR without compromising other OARs. The optimized, second version plans were compared against the first version plans and the clinically approved plans for 45 unilateral/bilateral target cases using the dose metrics: mean, median and maximum (brainstem and cord) doses. Results: Compared to the first version, the second version significantly reduced mean/median contralateral parotid doses (>2Gy) for bilateral cases. Other changes between the two versions were not clinically meaningful. Compared to the original clinical plans, both bilateral and unilateral plans in the second version had lower average dose metrics for 5 of the 6 OARs. Compared to the original plans, the second version achieved dose sparing that was at least as good for all OARs and better for the ipsilateral parotid (bilateral) and oral cavity (bilateral/unilateral). Differences in planning target volume coverage metrics were not clinically significant. Conclusion: HNC-KBRT planning generated IMRT plans with at least equivalent dose sparing to manually generated plans; greater dose sparing was achieved in selected OARs.

60 APPLIED LIFE SCIENCES↗

Mirror symmetry and elliptic Calabi-Yau manifolds

We find that for many Calabi-Yau threefolds with elliptic or genus one fibrations mirror symmetry factorizes between the fiber and the base of the fibration. In the simplest examples, the generic CY elliptic fibration over any toric base surface B that supports an elliptic Calabi-Yau threefold has a mirror that is an elliptic fibration over a dual toric base surface $\tilde{B}$ that is related through toric geometry to the line bundle -6 K B . The Kreuzer-Skarke database includes all these examples and gives a wide range of other more complicated constructions where mirror symmetry also factorizes. Since recent evidence suggests that most Calabi-Yau threefolds are elliptic or genus one fibered, this points to a new way of understanding mirror symmetry that may apply to a large fraction of smooth Calabi-Yau threefolds. The factorization structure identified here can also apply for CalabiYau manifolds of higher dimension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-H-CAMPUS-IeP1-03: Comparison of Monte Carlo Simulation and Conversion Factor Based Method On Estimation of Effective Dose in Pediatric Patients Undergoing Interventional Cardiac Procedures

Purpose: Interventional cardiac procedures utilize frequent fluoroscopy and cineangiography, which impose considerable radiation risk to patients, especially pediatric patients. Accurate calculation of effective dose is important in order to estimate cancer risk over the rest of their lifetime. This study evaluates the difference in effective dose calculated by Monte Carlo simulation with those estimated by locally-derived conversion factors (CF-local) and by commonly quoted conversion factors from Karambatsakidou et al (CF-K). Methods: Effective dose (E),of 12 pediatric patients, age between 2.5–19 years old, who had undergone interventional cardiac procedures, were calculated using PCXMC-2.0 software. Tube spectrum, irradiation geometry, exposure parameters and dose-area product (DAP) of each projection were included in the software calculation. Effective doses for each patient were also estimated by two Methods: 1) CF-local: conversion factor derived locally by generalizing results of 12 patients, multiplied by DAP of each patient gives E-local. 2) CF-K: selected factor from above-mentioned literature, multiplied by DAP of each patient gives E-K. Results: Mean of E, E-local and E-K were 16.01 mSv, 16.80 mSv and 22.25 mSv respectively. A deviation of −29.35% to +34.85% between E and E-local, while a greater deviation of −28.96% to +60.86% between E and EK were observed. E-K overestimated the effective dose for patients at age 7.5–19. Conclusion: Effective dose obtained by conversion factors is simple and quick to estimate radiation risk of pediatric patients. This study showed that estimation by CF-local may bear an error of 35% when compared with Monte Carlo calculation. If using conversion factors derived by other studies may result in an even greater error, of up to 60%, due to factors that are not catered for in the estimation, including patient size, projection angles, exposure parameters, tube filtration, etc. Users must be aware of these potential inaccuracies when simple conversion method is employed.

60 APPLIED LIFE SCIENCES↗

Boundary Representation Tolerance Impacts on Mesh Generation and Adaptation

The control of discretization error is critical to obtaining reliable simulation results. Re-cent progress has matured anisotropic mesh adaptation, which automates discretization error control for complex geometries. However, the meshing process can fail when geometric model Boundary REPresentation (BREP) tolerances are larger than boundary layer surface nor-mal and tangential spacing requirements. Geometry sources are often created in Mechanical Computer-Aided Design (MCAD) systems, which are designed to produce models for manufacturing and not the stricter requirements of viscous flow analysis. BREP tolerances are strained by three factors: the inherent complexity of the model (e.g., large range of scales and complex topology), the numerical difficulties arising from surface/surface intersections, and the omission of crucial data during export and translation. Manual preparation of geometry is commonly employed to enable expert-guided mesh generation, which severely inhibits work-flow automation. Accommodation of loose BREP tolerances is required for automated mesh processes, because barrier issues may not be detected until well into the solution process. To raise awareness of this class of geometry issues and their impact on simulation, a survey of these barrier issues is presented with example mitigation techniques. This awareness may also impact geometry creation workflows to prevent the introduction of these artifacts.

CAD↗

The composition of a coronal active region

The relative abundances of iron, oxygen, magnesium, and neon in a coronal active region are determined from measurements of soft X-ray line and broadband intensities. The emission measure, temperature, and column density are derived from these measured intensities and are used to place a constraint on the abundances of the heavier elements relative to hydrogen in the corona. The intensity measurements were made on 1987 December 11, when an active region was observed jointly by the American Science and Engineering (AS&E) High Resolution Soft X-Ray Imaging Sounding-Rocket Payload and the X-Ray Polychromator Flat Crystal Spectrometer (FCS) onboard the Solar Maximum Mission spacecraft. The coordinated observations include images through two broadband filters (8 to 29 A and 8 to 39, 44 to 60 A) and profiles of six emission lines: Fe XVII (15.01 A), FE VIII (15.26 A), O VIII (18.97 A), Mg XI (9.17 A), Ne IX (13.44 A), and Fe XVIII (14.21 A). The effects of resonance scattering are considered in the interpretation of the FCS line intensities. We calculated the expected intensity ratio of the two Fe XVII lines as a function of optical depth and compared this ratio with the observed intensity ratio to obtain the optical depths of each of the lines and the column density. The line intensities and the broadband filtered images are consistent with the emission from a thermal plasma where Fe, O, Mg, and Ne have the 'adopted coronal' abundances of Meyer (1985b) relative to one another, but are not consistent with the emission from a plasma having photospheric abundances: The ratios of the abundances of the low first ionization potential (FIP) elements (Fe and Mg) to the abundances of the high-FIP elements (Ne and O) are higher than the ratios seen in the photosphere by a factor of about 3.5. This conclusion is independent of the assumption of either an isothermal or a multithermal plasma. The column densities derived from the Fe XVII line ratio and the geometry of the active region provide a diagnostic of the abundance of hydrogen relative to the heavier elements. We find that the abundance of iron with respect to hydrogen in the corona is higher than the value given Meyer (1985b) by a factor of 8.2(-5.4, +5.1). This means that, for the observed active region, the absolute abundances of the low-FIP elements (Fe and Mg) are enhanced in the corona relative to the photosphere, while the abundances of the high-FIP elements (Ne and O) are either slightly enhanced in the corona or nearly the same in the photosphere and the corona.

Waljeski, K.↗

Photon Organ and Effective Dose Coefficients for Cranial and Caudal Irradiation Geometries - Paper 148

With the introduction of new recommendations of the ICRP in Publication 103 the methodology for determining the protection quantity effective dose has been modified. The modifications include changes in organ/tissue weighting factors as well as some changes in radiation weighting factors. Computations of protection dose coefficients now require the use of reference male and female voxel phantoms, see ICRP Publication 110. Computations of equivalent doses in organs and tissues are now performed in each phantom and the average is used to compute the effective dose. The latest set of external dose coefficients using the new reference phantoms and the latest guidance from the ICRP were performed by the ICRP DOCAL task group and reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Report 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT), and isotropic (ISO). For all geometries, except the ISO geometry, parallel beams are used to compute the dose coefficients. In this paper, the methodology of ICRP Publication 116 was used to compute dose coefficients for photons for irradiations of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace for personnel standing on contaminated surfaces or volumes and from overhead sources. In this work calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. Dose coefficients for caudal and cranial irradiation geometries have been calculated in accordance with ICRP Publication 103. The coefficients differ significantly from AP values for both organ and tissues of ICRP Publication 116, as would be expected. For workers in these scenarios organ and effective doses can differ significantly from AP values. For common photon energies (i.e. 100 keV to a few MeV) the AP effective dose overestimates the caudal and cranial values by about a factor of ten. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Generalized Squashing Factors for Covariant Description of Magnetic Connectivity in the Solar Corona

The study of magnetic connectivity in the solar corona reveals a need to generalize the field line mapping technique to arbitrary geometry of the boundaries and systems of coordinates. Indeed, the global description of the connectivity in the corona requires the use of the photospheric and solar wind boundaries. Both are closed surfaces and therefore do not admit a global regular system of coordinates. At least two overlapping regular systems of coordinates for each of the boundaries are necessary in this case to avoid spherical-pole-like singularities in the coordinates of the footpoints. This implies that the basic characteristic of magnetic connectivity-the squashing degree or factor Q of elemental flux tubes, according to Titov and coworkers-must be rewritten in covariant form. Such a covariant expression of Q is derived in this work. The derived expression is very flexible and highly efficient for describing the global magnetic connectivity in the solar corona. In addition, a general expression for a new characteristic Q1, which defines a squashing of the flux tubes in the directions perpendicular to the field lines, is determined. This new quantity makes it possible to filter out the quasi-separatrix layers whose large values of Q are caused by a projection effect at the field lines nearly touching the photosphere. Thus, the value Q1 provides a much more precise description of the volumetric properties of the magnetic field structure. The difference between Q and Q1 is illustrated by comparing their distributions for two configurations, one of which is the Titov-Demoulin model of a twisted magnetic field.

Titov, V. S.↗

FRW Like Cosmological Model and Accelerated Expansion of the Universe from Non Commutative Seiberg-Witten Geometry

An FRW like cosmological model in the non commutative Seiberg-Witten space-time is proposed. The pure NCG dynamical apparent horizon and Hawking temperature are obtained and explicit expressions of the scale factor, Hubble and deceleration parameters are derived. The accelerated expansion of the universe scenario is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmogenic nuclides in the Martian surface: Constraints for sample recovery and transport

Stable and radioactive cosmogenic nuclides and radiation damage effects such as cosmic ray tracks can provide information on the surface history of Mars. A recent overview on developments in cosmogenic nuclide research for historical studies of predominantly extraterrestrial materials was published previously. The information content of cosmogenic nuclides and radiation damage effects produced in the Martian surface is based on the different ways of interaction of the primary galactic and solar cosmic radiation (GCR, SCR) and the secondary particle cascade. Generally the kind and extent of interactions as seen in the products depend on the following factors: (1) composition, energy and intensity of the primary SCR and GCR; (2) composition, energy and intensity of the GCR-induced cascade of secondary particles; (3) the target geometry, i.e., the spatial parameters of Martian surface features with respect to the primary radiation source; (4) the target chemistry, i.e., the chemical composition of the Martian surface at the sampling location down to the minor element level or lower; and (5) duration of the exposure. These factors are not independent of each other and have a major influence on sample taking strategies and techniques.

Englert, Peter A. J.↗

All-order splits and multi-soft limits for particle and string amplitudes

The most important aspects of scattering amplitudes have long been thought to be associated with their poles. But recently a very different sort of “split” factorizations for a wide range of particle and string tree amplitudes have been discovered away from poles. In this paper, we give a simple, conceptual origin for these splits arising from natural properties of the binary geometry of the curve integral formulation for scattering amplitudes for Tr(Φ 3 ) theory. The most natural way of “joining” smaller surfaces to build larger ones directly produces a choice of kinematics for which higher amplitudes factor into lower ones. This gives a generalization of splits to all orders in the topological expansion. These splits allow us to access and compute loop-integrated multi-soft limits for particle and string amplitudes, at all loop orders. This includes split factorizations and multisoft limits for pion and gluon amplitudes, that are related to Tr(Φ 3 ) theory by a simple kinematical shift.

Bosonic Strings↗

One-way coupled simulation of FIV in a 7-pin wire-wrapped fuel pin bundle

A normal fuel geometry found in sodium cooled reactor designs is the hexagonal lattice of wire-wrapped fuel pins. The wire-wrappers, which replace the more common spacer grids, act as a spacer between the fuel pins, while simultaneously increasing the fluid mixing between subchannels. The induced transverse flow, while good for mixing, increases the force load experienced by the fuel pins, increasing the possibility of problematic flow induced vibrations. The primary source of vibrations is turbulent buffeting, so very small in amplitude, but capable of rupturing the fuel cladding by fretting. The vast majority of research on fretting has been for bare rods with spacer grids. There are several significant ways that wire-wrapped fuel pins differ from bare rods that may have significant impact on the vibrations present. The increased transverse flow and asymmetrical flow pattern may result in larger and imbalanced force loads on the pins. The helical bracing of each pin may result in unique vibration patterns, and gaps may form between pins affecting how they are braced. Simulation allows for the observation of the forces present, how the flow field affects these forces, and how the structure responds and can be repeated for multiple cases for relatively low cost. Here, simulation of the flow induced vibrations for a 7-pin wire-wrapped fuel pin bundle is carried out by coupling Nek5000, a spectral element LES/DNS solver with DIABLO, a finite element CSM solver. The small amplitude vibrations allow for the assumption that the structure motion has negligible effect on the fluid flow, permitting the much less computationally expensive one-direction coupling. In order to gather significant force history data for the 2.63 helical pitch structure, a scheme was developed to artificially create force history from the power spectrum density of the one-pitch CFD simulation forces. The vibrations could then be simulated in the structure multiple times varying the contact and gaps between various pins. This provides for the search of worst-case scenarios and informs about the types of fretting that might be present. The simulation geometry is based on an experiment for comparison. However, the viscosity of the simulation was increased by a factor of four to make the simulation computationally feasible. While validation is not possible, comparisons are still valuable.

42 ENGINEERING↗

FEM Analysis of Defects and Microstructure Evolution during Hot Working of Specialty Alloys

The main goals of process simulation in manufacturing are to reduce manufacturing/part development time and cost as well as increasing quality and productivity. In this study, porosity evolution is modeled by introducing a porosity evolution parameter, which is function of strain rate and stress triaxiality factor. Applicability is shown by simulating the first two stages of an ingot conversion process; variables are die geometry and bite size. Moreover, application is extended to hot shape rolling, where the geometry of the oval passes is the variable. Validation is carried out through evaluation of samples from final products. Also, surface defects in hot shape rolling are tracked by studying the instability during the rolling of the material. Plastic work approach was used to judge the occurrence of instability during the process. The effect of number of passes and roll gap was examined to predict the occurrence of surface cracking. On the other hand, unrecrystallized grains and coarse grain problem are other significant problems in the metalworking industry. A recrystallization model is implemented in a finite element framework, to study the effect of forging parameters on the microstructure evolution during ingot conversion process of a superalloy.

36 MATERIALS SCIENCE↗

Spectroscopic diagnostics for liquid lithium divertor studies on National Spherical Torus Experiment

The use of lithium-coated plasma facing components for plasma density control is studied in the National Spherical Torus Experiment (NSTX). A recently installed liquid lithium divertor (LLD) module has a porous molybdenum surface, separated by a stainless steel liner from a heated copper substrate. Lithium is deposited on the LLD from two evaporators. Two new spectroscopic diagnostics are installed to study the plasma surface interactions on the LLD: (1) A 20-element absolute extreme ultraviolet (AXUV) diode array with a 6 nm bandpass filter centered at 121.6 nm (the Lyman-{alpha} transition) for spatially resolved divertor recycling rate measurements in the highly reflective LLD environment, and (2) an ultraviolet-visible-near infrared R=0.67 m imaging Czerny-Turner spectrometer for spatially resolved divertor D I, Li I-II, C I-IV, Mo I, D{sub 2}, LiD, CD emission and ion temperature on and around the LLD module. The use of photometrically calibrated measurements together with atomic physics factors enables studies of recycling and impurity particle fluxes as functions of LLD temperature, ion flux, and divertor geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Does jackknife scale really matter for accurate large-scale structure covariances?

ABSTRACT The jackknife method gives an internal covariance estimate for large-scale structure surveys and allows model-independent errors on cosmological parameters. Using the SDSS-III BOSS CMASS sample, we study how the jackknife size and number of resamplings impact the precision of the covariance estimate on the correlation function multipoles and the error on the inferred baryon acoustic scale. We compare the measurement with the MultiDark Patchy mock galaxy catalogues, and we also validate it against a set of lognormal mocks with the same survey geometry. We build several jackknife configurations that vary in size and number of resamplings. We introduce the Hartlap factor in the covariance estimate that depends on the number of jackknife resamplings. We also find that it is useful to apply the tapering scheme to estimate the precision matrix from a limited number of resamplings. The results from CMASS and mock catalogues show that the error estimate of the baryon acoustic scale does not depend on the jackknife scale. For the shift parameter α, we find an average error of 1.6 per cent, 2.2 per cent and 1.2 per cent, respectively, from CMASS, Patchy, and lognormal jackknife covariances. Despite these uncertainties fluctuate significantly due to some structural limitations of the jackknife method, our α estimates are in reasonable agreement with published pre-reconstruction analyses. Jackknife methods will provide valuable and complementary covariance estimates for future large-scale structure surveys.

Favole, Ginevra (ORCID:000000028218563X)↗

Polarimetric SAR Image Terrain Classification

In practical applications of automated terrain classification from high-resolution polarimetric synthetic aperture radar (PolSAR) imagery, different terrain types may inherently contain a high level of internal variability, as when a broadly defined class (e.g., “trees”) contains elements arising from multiple subclasses (pine, oak, and willow). In addition, real-world factors such as the time of year of a collection, the moisture content of the scene, the imaging geometry, and the radar system parameters can all increase the variability observed within each class. Such variability challenges the ability of classifiers to maintain a high level of sensitivity in recognizing diverse elements that are within-class, without sacrificing their selectivity in rejecting out-of-class elements. In an effort to gauge the degree to which classifiers respond robustly in the presence of intraclass variability and generalize to untrained scenes and conditions, here we compare the performance of a suite of classifiers across six broad terrain categories from a large set of polarimetric synthetic aperture radar (PolSAR) image sets. The main contributions of this article are as follows: 1) an analysis of the robustness of a variety of current state-of-the art classification algorithms to intraclass variability found in PolSAR image sets, and 2) the associated PolSAR image and feature data that Sandia is releasing to the research community with this publication. The analysis of the classification algorithms we provide will serve as a benchmark of performance for the future PolSAR terrain classification algorithm research and development enabled by the image sets and data provided. By sharing our analysis and high-resolution fully polarimetric Sandia data with the research community, we enable others to develop and assess a new generation of robust terrain classification algorithms for PolSAR.

42 ENGINEERING↗

SU-G-BRB-15: Verifications of Absolute and Relative Dosimetry of a Novel Stereotactic Breast Device: GammaPodTM

Purpose: A dedicated stereotactic breast radiotherapy device, GammaPod, was developed to treat early stage breast cancer. The first clinical unit was installed and commissioned at University of Maryland. We report our methodology of absolute dosimetry in multiple calibration conditions and dosimetric verifications of treatment plans produced by the system. Methods: GammaPod unit is comprised of a rotating hemi-spherical source carrier containing 36 Co-60 sources and a concentric tungsten collimator providing beams of 15 and 25 mm. Absolute dose calibration formalism was developed with modifications to AAPM protocols for unique geometry and different calibration medium (acrylic, polyethylene or liquid water). Breast cup-size specific and collimator output factors were measured and verified with respect to Monte-Carlo simulations for single isocenter plans. Multiple isocenter plans were generated for various target size, location and cup-sizes in phantoms and 20 breast cancer patients images. Stereotactic mini-farmer chamber, OSL and TLD detectors as well as radio-chromic films were used for dosimetric measurements. Results: At the time of calibration (1/14/2016), absolute dose rate of the GammaPod was established to be 2.10 Gy/min in acrylic for 25 mm for sources installed in March 2011. Output factor for 15 mm collimator was measured to be 0.950. Absolute dose calibration was independently verified by IROC-Houston with a TLD/Institution ratio of 0.99. Cup size specific output measurements in liquid water for single isocenter were found to be within 3.0% of MC simulations. Point-dose measurements of multiple isocenter treatment plans were found to be within −1.0 ± 1.2 % of treatment planning system while 2-dimensional gamma analysis yielded a pass rate of 97.9 ± 2.2 % using gamma criteria of 3% and 2mm. Conclusion: The first GammaPod treatment unit for breast stereotactic radiotherapy was successfully installed, calibrated and commissioned for patient treatments. An absolute dosimetry and dosimetric verification protocols were successfully created.

60 APPLIED LIFE SCIENCES↗