Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Geostationary Satellite Observations Over Global Environmental Monitoring Sites

Globally, there are now hundreds of ground-based environmental monitoring stations routinely collecting data on a variety of earth-atmosphere interactions. Such observations are also being augmented with data from orbiting satellites. With the beginning of the EOS-era, the MODIS subset around flux towers has been frequently used for validating ecosystem models developed at flux towers and upscaling the observed flux data to regional scales. However, MODIS on the polar-orbiting satellites can observe target regions only once a day, while the Fluxnet eddy- covariance data are compiled as sub-hourly. Therefore, summarizing the sub-hourly flux data into daily statistics is necessary for the comparison between MODIS and Flux data. The new generation geostationary satellite sensors (GOES-16/17 ABI and Himawari-8/9 AHI) have capabilities similar to MODIS but collect data at 5-15 minute intervals. These high-frequency observations allow us to understand and scale diurnal fluxes. Some studies have already shown the effective utilization of time series of geostationary satellite data for ecosystem modeling. We are producing NEX Level-1G products, which are gridded Top-of-Atmosphere reflectance and brightness temperature data from geostationary satellite sensors. We cut out the NEX Level-1G data using the same file format with the MODIS subset except for the projection. The other data products (e.g., surface reflectance, land surface temperature, vegetation indices, and climate data) will be added upon their availability. Currently included networks are Fluxnet, PhenoCam, and AERONET. The NEX subset data will be provided through NASA NEX data portal.

Geostationary Satellites↗

Development of sensors for ceramic components in advanced propulsion systems: Survey and evaluation of measurement techniques for temperature, strain and heat flux for ceramic components in advanced propulsion systems

The report presents the final results of Tasks 1 and 2, Development of Sensors for Ceramic Components in Advanced Propulsion Systems (NASA program NAS3-25141). During Task 1, an extensive survey was conducted of sensor concepts which have the potential for measuring surface temperature, strain and heat flux on ceramic components for advanced propulsion systems. Each sensor concept was analyzed and evaluated under Task 2; sensor concepts were then recommended for further development. For temperature measurement, both pyrometry and thermographic phosphors are recommended for measurements up to and beyond the melting point of ceramic materials. For lower temperature test programs, the thin-film techniques offer advantages in the installation of temperature sensors. Optical strain measurement techniques are recommended because they offer the possibility of being useful at very high temperature levels. Techniques for the measurement of heat flux are recommended for development based on both a surface mounted sensor and the measurement of the temperature differential across a portion of a ceramic component or metallic substrate.

Atkinson, W. H.↗

Evaluation of WSR-88D Level III and MRMS Rainfall Estimates Against Rain Gauge Observations at the Savannah River Site

Rainfall data for the Savannah River Site (SRS) has been historically measured by rain gauges. These instruments serve as ground truth for most climatological and weather applications; however, gauge measurements are prone to errors or biases under certain weather conditions. Rainfall estimates from radar reflectivity values have been developed and improved over the years and serve as an alternative or supplement for gauge measurements. This study compares measurements from tipping bucket rain gauges with rainfall estimates from the NOAA NWS WSR-88D Level III hourly rainfall product and the Multi-Radar Multi-Sensor (MRMS) gauge-corrected precipitation estimate. Results show good agreement between radar derived amounts and ground measurements, with MRMS values showing correlation coefficients of 0.60-0.95 and RMSE values of less than 1.0 cm (0.4 in). The WSR-88D Level III estimates result in correlation coefficients of 0.46-0.86 and RMSE values of less than 1.3 cm (0.5 in). Few outliers are observed for each data pair and are evaluated against precipitation classification products (WSR-88D Hybrid Hydrometeor Classification product and MRMS Precipitation Flag product). The rain gauges used in this study are not part of the Hydrometeorological Automated Data System (HADS) network used to correct the MRMS estimates and therefore, results of this work provide an independent validation of the MRMS gauge correction scheme.

54 ENVIRONMENTAL SCIENCES↗

LASE measurements of aerosols and water vapor during TARFOX

The TARFOX (Tropospheric Aerosol Radiative Forcing Observational Experiment) intensive field campaign was designed to reduce uncertainties in estimates of the effects of anthropogenic aerosols on climate by measuring direct radiative effects and the optical, physical, and chemical properties of aerosols [1]. TARFOX was conducted off the East Coast of the United States between July 10-31, 1996. Ground, aircraft, and satellite-based sensors measured the sensitivity of radiative fields at various atmospheric levels to aerosol optical properties (i.e., optical thickness, phase function, single-scattering albedo) and to the vertical profile of aerosols. The LASE (Lidar Atmospheric Sensing Experiment) instrument, which was flown on the NASA ER-2 aircraft, measured vertical profiles of total scattering ratio and water vapor during a series of 9 flights. These profiles were used in real-time to help direct the other aircraft to the appropriate altitudes for intensive sampling of aerosol layers. We have subsequently used the LASE aerosol data to derive aerosol backscattering and extinction profiles. Using these aerosol extinction profiles, we derived estimates of aerosol optical thickness (AOT) and compared these with measurements of AOT from both ground and airborne sun photometers and derived from the ATSR-2 (Along Track and Scanning Radiometer 2) sensor on ERS-2 (European Remote Sensing Satellite-2). We also used the water vapor mixing ratio profiles measured simultaneously by LASE to derive precipitable water vapor and compare these to ground based measurements.

Ferrare, Richard A.↗

A method for infrared sensing based on oscillating zero power microelectromechanical photoswitches

This paper presents an interesting new method for measuring infrared (IR) radiation using a micromechanical photoswitch (MP). By leveraging the event-driven narrowband IR detection capability of an MP, electrostatic pull-in, and a novel integrated thermomechanical feedback mechanism, we show for the first time a zero-standby power IR sensor that can not only detect above-threshold IR power levels (>600 nW), but also generates an oscillating electromechanical pulse waveform whose frequency is a function of the incident IR power level. The device design, the theoretical model for the proposed idea, and the experimental demonstration of the mechanism are shown. The unique capability of zero-standby power IR detection and frequency-tunable AC waveform generation from a constant input signal (IR radiation) without the need for additional electronics promises to enable new functionalities for such remote wake-up sensors beyond simply detection, with potential uses in microrobotics and low-power computing.

Rajaram, Vageeswar (ORCID:0000000199546844)↗

High Temperature Pt/Alumina Co-Fired System for 500 C Electronic Packaging Applications

Gold thick-film metallization and 96 alumina substrate based prototype packaging system developed for 500C SiC electronics and sensors is briefly reviewed, the needs of improvement are discussed. A high temperature co-fired alumina material system based packaging system composed of 32-pin chip-level package and printed circuit board is discussed for packaging 500C SiC electronics and sensors.

High temperature↗

Preparation and application of Mn-Doped Zn0.5Cd0.5S @ ZnS nanorods with high quantum yield as sensitive fluorescence probe for detection of glucose

Highlights: • Mn:ZCS@ZnS NRs are successfully synthesized by a facile thermal decomposition approach. • Mn:ZCS@ZnS NRs exhibit high photoluminescence with quantum yield reaching up to 85%. • Mn:ZCS@ZnS NRs with high quantum yield can be used as sensitive probe for glucose detection. - Abstract: Blood glucose level is a crucial clinical index of monitoring diabetes patients. Glucose sensors based on fluorescent quantum dots have received extensive attention. Herein, a highly photoluminescent Mn-doped Zn{sub 0.5}Cd{sub 0.5}S capped ZnS nanorods (Mn:ZCS@ZnS NRs) are successfully synthesized by a facile thermal decomposition approach. The maximum fluorescence quantum yield (QY) of as-prepared Mn:ZCS@ZnS NRs enable to reach 85% by optimizing Mn-doping level, temperature, time and ZnS coating. The results of probe experiments for glucose indicate that H{sub 2}O{sub 2} generated from the oxidation of glucose in presence of glucose oxidase (GOD) can lead to a pronounced decrease of fluorescence intensity of Mn:ZCS@ZnS NRs samples. Two distinct linear detections within the range from 50 μM to 300 μM and from 200 μM to 1000 μM are obtained and the limit of detection can reach to 100 nM. Preliminary study exhibits that Mn:ZCS@ZnS nanorods with high fluorescence quantum yield can be used as an efficient fluorescent probe for glucose detection.

60 APPLIED LIFE SCIENCES↗

Network-Capable Application Process and Wireless Intelligent Sensors for ISHM

Intelligent sensor technology and systems are increasingly becoming attractive means to serve as frameworks for intelligent rocket test facilities with embedded intelligent sensor elements, distributed data acquisition elements, and onboard data acquisition elements. Networked intelligent processors enable users and systems integrators to automatically configure their measurement automation systems for analog sensors. NASA and leading sensor vendors are working together to apply the IEEE 1451 standard for adding plug-and-play capabilities for wireless analog transducers through the use of a Transducer Electronic Data Sheet (TEDS) in order to simplify sensor setup, use, and maintenance, to automatically obtain calibration data, and to eliminate manual data entry and error. A TEDS contains the critical information needed by an instrument or measurement system to identify, characterize, interface, and properly use the signal from an analog sensor. A TEDS is deployed for a sensor in one of two ways. First, the TEDS can reside in embedded, nonvolatile memory (typically flash memory) within the intelligent processor. Second, a virtual TEDS can exist as a separate file, downloadable from the Internet. This concept of virtual TEDS extends the benefits of the standardized TEDS to legacy sensors and applications where the embedded memory is not available. An HTML-based user interface provides a visual tool to interface with those distributed sensors that a TEDS is associated with, to automate the sensor management process. Implementing and deploying the IEEE 1451.1-based Network-Capable Application Process (NCAP) can achieve support for intelligent process in Integrated Systems Health Management (ISHM) for the purpose of monitoring, detection of anomalies, diagnosis of causes of anomalies, prediction of future anomalies, mitigation to maintain operability, and integrated awareness of system health by the operator. It can also support local data collection and storage. This invention enables wide-area sensing and employs numerous globally distributed sensing devices that observe the physical world through the existing sensor network. This innovation enables distributed storage, distributed processing, distributed intelligence, and the availability of DiaK (Data, Information, and Knowledge) to any element as needed. It also enables the simultaneous execution of multiple processes, and represents models that contribute to the determination of the condition and health of each element in the system. The NCAP (intelligent process) can configure data-collection and filtering processes in reaction to sensed data, allowing it to decide when and how to adapt collection and processing with regard to sophisticated analysis of data derived from multiple sensors. The user will be able to view the sensing device network as a single unit that supports a high-level query language. Each query would be able to operate over data collected from across the global sensor network just as a search query encompasses millions of Web pages. The sensor web can preserve ubiquitous information access between the querier and the queried data. Pervasive monitoring of the physical world raises significant data and privacy concerns. This innovation enables different authorities to control portions of the sensing infrastructure, and sensor service authors may wish to compose services across authority boundaries.

Figueroa, Fernando↗

CATALYST AMMONIA STORAGE MEASUREMENTS USING RADIO FREQUENCY SENSING

Motivated by increasingly strict NO x limits, engine manufactures have adopted selective catalytic reduction (SCR) technology to reduce engine-out NO x below mandated levels. In the SCR process, nitrogen oxides (NO x ) react with ammonia (NH 3 ) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NO x and/or NH 3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF) -based method to directly monitor the ammonia storage state of the SCR catalyst. This approach utilizes the SCR catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. Ammonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored ammonia (NH 3 ) were evaluated over a wide frequency range as well as temperature and exhaust conditions. The RF response to NH 3 storage, desorption, and oxidation on the SCR was observed to be well-correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10 % of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NO x conversion and decrease urea consumption.

Aguilar, Jonathan↗

Non-destructive plant health sensing using absorption spectroscopy

The sensor group of the 1988 EGM 4001 class, working on NASA's Controlled Ecological Life Support Systems (CELSS) project, investigated many different plant health indicators and the technologies used to test them. The project selected by the group was to measure chlorophyll levels using absorption spectroscopy. The spectrometer measures the amount of chlorophyll in a leaf by measuring the intensity of light of a specific wavelength that is passed through a leaf. The three wavelengths of light being used corresponded to the near-IR absorption peaks of chlorophyll a, chlorophyll b, and chlorophyll-free structures. Experimentation showed that the sensor is indeed measuring levels of chlorophyll a and b and their changes before the human eye can see any changes. The detector clamp causes little damage to the leaf and will give fairly accurate readings on similar locations on a leaf, freeing the clamp from having to remain on the same spot of a leaf for all measurements. External light affects the readings only slightly so that measurements may be taken in light or dark environments. Future designs and experimentation will concentrate on reducing the size of the sensor and adapting it to a wider range of plants.

Bledsoe, Jim↗

Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride

Hydrogen fluoride (HF) is a primary evolved combustion product of fluorinated and perfluorinated hydrocarbons. HF is produced during combustion by the presence of impurities and hydrogen- containing polymers including polyimides. This effect is especially dangerous in closed occupied volumes like spacecraft and submarines. In these systems, combinations of perfluorinated hydrocarbons and polyimides are used for insulating wiring. HF is both highly toxic and short-lived in closed environments due to its reactivity. The high reactivity also makes HF sampling problematic. An infrared optical sensor can detect promptly evolving HF with minimal sampling requirements, while providing both high sensitivity and high specificity. A rugged optical path length enhancement architecture enables both high HF sensitivity and rapid environmental sampling with minimal gaseous contact with the low-reactivity sensor surfaces. The inert optical sample cell, combined with infrared semiconductor lasers, is joined with an analog and digital electronic control architecture that allows for ruggedness and compactness. The combination provides both portability and battery operation on a simple camcorder battery for up to eight hours. Optical detection of gaseous HF is confounded by the need for rapid sampling with minimal contact between the sensor and the environmental sample. A sensor is required that must simultaneously provide the required sub-parts-permillion detection limits, but with the high specificity and selectivity expected of optical absorption techniques. It should also be rugged and compact for compatibility with operation onboard spacecraft and submarines. A new optical cell has been developed for which environmental sampling is accomplished by simply traversing the few mm-thick cell walls into an open volume where the measurement is made. A small, low-power fan or vacuum pump may be used to push or pull the gaseous sample into the sample volume for a response time of a few seconds. The optical cell simultaneously provides for an enhanced optical interaction path length between the environmental sample and the infrared laser. Further, the optical cell itself is comprised of inert materials that render it immune to attack by HF. In some cases, the sensor may be configured so that the optoelectronic devices themselves are protected and isolated from HF by the optical cell. The optical sample cell is combined with custom-developed analog and digital control electronics that provide rugged, compact operation on a platform that can run on a camcorder battery. The sensor is inert with respect to acidic gases like HF, while providing the required sensitivity, selectivity, and response time. Certain types of combustion events evolve copious amounts of HF, very little of other gases typically associated with combustion (e.g., carbon monoxide), and very low levels of aerosols and particulates (which confound traditional smoke detectors). The new sensor platform could warn occupants early enough to take the necessary countermeasures.

Pilgrim, Jeffrey↗

Large Scale Production of Densified Hydrogen to the Triple Point and Below

Recent demonstration of advanced liquid hydrogen storage techniques using Integrated Refrigeration and Storage technology at NASA Kennedy Space Center led to the production of large quantities of densified liquid and slush hydrogen in a 125,000 L tank. Production of densified hydrogen was performed at three different liquid levels and LH2 temperatures were measured by twenty silicon diode temperature sensors. Overall densification performance of the system is explored, and solid mass fractions are calculated. Experimental data reveal hydrogen temperatures dropped well below the triple point during testing, and were continuing to trend downward prior to system shutdown. Sub-triple point temperatures were seen to evolve in a time dependent manner along the length of the horizontal, cylindrical vessel. The phenomenon, observed at two fill levels, is detailed herein. The implications of using IRAS for energy storage, propellant densification, and future cryofuel systems are discussed.

IRAS↗

Large Scale Production of Densified Hydrogen to the Triple Point and Below

Recent demonstration of advanced liquid hydrogen storage techniques using Integrated Refrigeration and Storage technology at NASA Kennedy Space Center led to the production of large quantities of densified liquid and slush hydrogen in a 125,000 L tank. Production of densified hydrogen was performed at three different liquid levels and LH2 temperatures were measured by twenty silicon diode temperature sensors. Overall densification performance of the system is explored, and solid mass fractions are calculated. Experimental data reveal hydrogen temperatures dropped well below the triple point during testing, and were continuing to trend downward prior to system shutdown. Sub-triple point temperatures were seen to evolve in a time dependent manner along the length of the horizontal, cylindrical vessel. The phenomenon, observed at two fill levels, is detailed herein. The implications of using IRAS for energy storage, propellant densification, and future cryofuel systems are discussed.

Hydrogen↗

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optical Mass Gauging System for Measuring Liquid Levels in a Reduced Gravity Environment

A compact and rugged fiber-coupled liquid volume sensor designed for flight on a sounding rocket platform is presented. The sensor consists of a Mach-Zehnder interferometer capable of measuring the amount of liquid contained in a tank under any gravitational conditions, including a microgravity environment, by detecting small changes in the index of refraction of the gas contained within a sensing region. By monitoring changes in the interference fringe pattern as the system undergoes a small compression provided by a piston, the ullage volume of a tank can be directly measured allowing for a determination of the liquid volume. To demonstrate the technique, data are acquired using two tanks containing different volumes of liquid, which are representative of the levels of liquid in a tank at different time periods during a mission. The two tanks are independently exposed to the measurement apparatus, allowing for a determination of the liquid level in each. In a controlled, laboratory test of the unit, the system demonstrated a capability of measuring a liquid level in an individual tank of 10.53 mL with a 2% error. The overall random uncertainty for the flight system is higher than that one test, at +/- 1.5 mL.

Sullenberger, Ryan M.↗

Low cost fluidic sensors

The gyroscopic inertial sensors used in general aviation autopilots and in stability augmentation systems probably contribute more than any other component to the initial cost and to the continuing maintenance costs of these installations. Several fluidic devices which were developed to replace the gyroscopes in the conventional ""wing-leveler'' type autopilots used in small, general aviation airplanes are described. These sensors are characterized by simplicity of design, ease of fabrication, and lack of wearing parts. A unique, fluidic, true airspeed sensor is also described. All these devices are adapted to fabrication by low cost plastic molding techniques, and their lack of wearing parts promises long, maintenance free service lives.

Garner, H. D.↗

Modeling Urban Acoustic Noise in the Las Vegas, NV Region

Ambient infrasound noise in quiet, rural environments has been extensively studied and well-characterized through noise models for several decades. More recently, creating noise models for high-noise rural environments has also become an area of active research. However, far less work has been done to create generalized low-frequency noise models for urban areas. The high ambient noise levels expected in cities and other highly populated areas means that these environments are regarded as poor locations for acoustic sensors, and historically, sensor deployment in urban areas were avoided for this reason. However, there are several advantages to placing sensors in urban environments, including convenience of deployment and maintenance, and increasingly, necessity, as more previously rural areas become populated. This study seeks to characterize trends in low-frequency urban noise by creating a background noise model for Las Vegas, NV, using the Las Vegas Infrasound Array (LVIA): a network of eleven infrasound sensors deployed throughout the city. Data included in this study spans from 2019 to 2021 and provides a largely uninterrupted record of noise levels in the city from 0.1–500 Hz, with only minor discontinuities on individual stations. We organize raw data from the LVIA sensors into hourly power spectral density (PSD) averages for each station and select from these PSDs to create frequency distributions for time periods of interest . These frequency distributions are converted into probability density functions (PDFs), which are then used to evaluate variations in frequency and amplitude over daily to seasonal timescale s. In addition to PDFs, the median, 5 th percentile, and 95 th percentile amplitude values are calculated across the entire frequency range. This methodology follows a well-established process for noise model creation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Characterization of Precipitation-Induced Radon Progeny Deposition Events Using a City-Scale Sensor Network

Networks of radiation detectors provide a platform for real-time radioactive source detection and identification in urban environments. Detection algorithms in these systems must adapt to naturally-occurring changes in background, which requires well-characterized relationships between precipitation events and their corresponding radiological signature. Here, we present a quantitative and qualitative description of rain-induced radon progeny deposition events occurring in Chicago from September 2023 to February 2024. We measure ambient gamma radiation levels, precipitation rate, temperature, pressure, and relative humidity in a network of sensor nodes. For each identified precipitation period, we decompose spectra into static- and radon-associated components as defined by a non-negative matrix factorization (NMF) algorithm. We find a consistent power-law relationship between a precipitation-dependent peak of the radon progeny proxy (RPP) and the peak strength of the radon-associated NMF component for most precipitation events. We conduct a case study of a rainfall period with abnormally high levels of implied radon progeny concentration and describe its temporal and spatial evolution. We hypothesize that this phenomenon is due to the air mass path that intersects a uranium-rich region of Wyoming. Finally, we cluster precipitation events into three distinct categories. One category roughly corresponds to events with deep low-pressure systems and high relative radon concentration, while another is characteristic of light stratiform rain with slightly higher temperatures and intermediate relative radon concentration. The third category appears to contain weak-gradient or lake breeze convection showers with intermittent precipitation and low relative radon concentration. These findings suggest that radiological anomaly detection could be improved by training unique background models corresponding to each category of meteorological event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗