Search NASA⌕ Search

SEARCH · Search NASA

Results for “maximum likelihood”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction

Purpose: Aims in this study are to (1) develop a computational model observer which reliably tracks the detectability of human observers in low dose computed tomography (CT) images reconstructed with knowledge-based iterative reconstruction (IMR™, Philips Healthcare) and filtered back projection (FBP) across a range of independent variables, (2) use the model to evaluate detectability trends across reconstructions and make predictions of human observer detectability, and (3) perform human observer studies based on model predictions to demonstrate applications of the model in CT imaging. Methods: Detectability (d′) was evaluated in phantom studies across a range of conditions. Images were generated using a numerical CT simulator. Trained observers performed 4-alternative forced choice (4-AFC) experiments across dose (1.3, 2.7, 4.0 mGy), pin size (4, 6, 8 mm), contrast (0.3%, 0.5%, 1.0%), and reconstruction (FBP, IMR), at fixed display window. A five-channel Laguerre–Gauss channelized Hotelling observer (CHO) was developed with internal noise added to the decision variable and/or to channel outputs, creating six different internal noise models. Semianalytic internal noise computation was tested against Monte Carlo and used to accelerate internal noise parameter optimization. Model parameters were estimated from all experiments at once using maximum likelihood on the probability correct, P{sub C}. Akaike information criterion (AIC) was used to compare models of different orders. The best model was selected according to AIC and used to predict detectability in blended FBP-IMR images, analyze trends in IMR detectability improvements, and predict dose savings with IMR. Predicted dose savings were compared against 4-AFC study results using physical CT phantom images. Results: Detection in IMR was greater than FBP in all tested conditions. The CHO with internal noise proportional to channel output standard deviations, Model-k4, showed the best trade-off between fit and model complexity according to AIC{sub c}. With parameters fixed, the model reasonably predicted detectability of human observers in blended FBP-IMR images. Semianalytic internal noise computation gave results equivalent to Monte Carlo, greatly speeding parameter estimation. Using Model-k4, the authors found an average detectability improvement of 2.7 ± 0.4 times that of FBP. IMR showed greater improvements in detectability with larger signals and relatively consistent improvements across signal contrast and x-ray dose. In the phantom tested, Model-k4 predicted an 82% dose reduction compared to FBP, verified with physical CT scans at 80% reduced dose. Conclusions: IMR improves detectability over FBP and may enable significant dose reductions. A channelized Hotelling observer with internal noise proportional to channel output standard deviation agreed well with human observers across a wide range of variables, even across reconstructions with drastically different image characteristics. Utility of the model observer was demonstrated by predicting the effect of image processing (blending), analyzing detectability improvements with IMR across dose, size, and contrast, and in guiding real CT scan dose reduction experiments. Such a model observer can be applied in optimizing parameters in advanced iterative reconstruction algorithms as well as guiding dose reduction protocols in physical CT experiments.

60 APPLIED LIFE SCIENCES↗

Scatter and crosstalk corrections for {sup 99m}Tc/{sup 123}I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators

Purpose: The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for {sup 99m}Tc/{sup 123}I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c). Methods: A tailing model was developed to account for the low energy tail effects of the CZT detector. The parameters of the model were obtained using {sup 99m}Tc and {sup 123}I point source measurements. A scatter model was defined to characterize the relationship between down-scatter and self-scatter projections. The parameters for this model were obtained from Monte Carlo simulation using SIMIND. The tailing and scatter models were further incorporated into a projection count model, and the primary and self-scatter projections of each radionuclide were determined with a maximum likelihood expectation maximization (MLEM) iterative estimation approach. The extracted scatter and crosstalk projections were then incorporated into MLEM image reconstruction as an additive term in forward projection to obtain scatter- and crosstalk-corrected images. The proposed method was validated using Monte Carlo simulation, line source experiment, anthropomorphic torso phantom studies, and patient studies. The performance of the proposed method was also compared to that obtained with the conventional TEW method. Results: Monte Carlo simulations and line source experiment demonstrated that the TEW method overestimated scatter while their proposed method provided more accurate scatter estimation by considering the low energy tail effect. In the phantom study, improved defect contrasts were observed with both correction methods compared to no correction, especially for the images of {sup 99m}Tc in dual-radionuclide imaging where there is heavy contamination from {sup 123}I. In this case, the nontransmural defect contrast was improved from 0.39 to 0.47 with the TEW method and to 0.51 with their proposed method and the transmural defect contrast was improved from 0.62 to 0.74 with the TEW method and to 0.73 with their proposed method. In the patient study, the proposed method provided higher myocardium-to-blood pool contrast than that of the TEW method. Similar to the phantom experiment, the improvement was the most substantial for the images of {sup 99m}Tc in dual-radionuclide imaging. In this case, the myocardium-to-blood pool ratio was improved from 7.0 to 38.3 with the TEW method and to 63.6 with their proposed method. Compared to the TEW method, the proposed method also provided higher count levels in the reconstructed images in both phantom and patient studies, indicating reduced overestimation of scatter. Using the proposed method, consistent reconstruction results were obtained for both single-radionuclide data with scatter correction and dual-radionuclide data with scatter and crosstalk corrections, in both phantom and human studies. Conclusions: The authors demonstrate that the TEW method leads to overestimation in scatter and crosstalk for the CZT-based imaging system while the proposed scatter and crosstalk correction method can provide more accurate self-scatter and down-scatter estimations for quantitative single-radionuclide and dual-radionuclide imaging.

60 APPLIED LIFE SCIENCES↗

4D ML reconstruction as a tool for volumetric PET-based treatment verification in ion beam radiotherapy

Purpose: An innovative strategy to improve the sensitivity of positron emission tomography (PET)-based treatment verification in ion beam radiotherapy is proposed. Methods: Low counting statistics PET images acquired during or shortly after the treatment (Measured PET) and a Monte Carlo estimate of the same PET images derived from the treatment plan (Expected PET) are considered as two frames of a 4D dataset. A 4D maximum likelihood reconstruction strategy was adapted to iteratively estimate the annihilation events distribution in a reference frame and the deformation motion fields that map it in the Expected PET and Measured PET frames. The outputs generated by the proposed strategy are as follows: (1) an estimate of the Measured PET with an image quality comparable to the Expected PET and (2) an estimate of the motion field mapping Expected PET to Measured PET. The details of the algorithm are presented and the strategy is preliminarily tested on analytically simulated datasets. Results: The algorithm demonstrates (1) robustness against noise, even in the worst conditions where 1.5 × 10{sup 4} true coincidences and a random fraction of 73% are simulated; (2) a proper sensitivity to different kind and grade of mismatches ranging between 1 and 10 mm; (3) robustness against bias due to incorrect washout modeling in the Monte Carlo simulation up to 1/3 of the original signal amplitude; and (4) an ability to describe the mismatch even in presence of complex annihilation distributions such as those induced by two perpendicular superimposed ion fields. Conclusions: The promising results obtained in this work suggest the applicability of the method as a quantification tool for PET-based treatment verification in ion beam radiotherapy. An extensive assessment of the proposed strategy on real treatment verification data is planned.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of practical initial attenuation image estimates in TOF-MLAA reconstruction for PET/MR

Purpose: Time-of-flight joint attenuation and activity positron emission tomography reconstruction requires additional calibration (scale factors) or constraints during or post-reconstruction to produce a quantitative μ-map. In this work, the impact of various initializations of the joint reconstruction was investigated, and the initial average mu-value (IAM) method was introduced such that the forward-projection of the initial μ-map is already very close to that of the reference μ-map, thus reducing/minimizing the offset (scale factor) during the early iterations of the joint reconstruction. Consequently, the accuracy and efficiency of unconstrained joint reconstruction such as time-of-flight maximum likelihood estimation of attenuation and activity (TOF-MLAA) can be improved by the proposed IAM method. Methods: 2D simulations of brain and chest were used to evaluate TOF-MLAA with various initial estimates which include the object filled with water uniformly (conventional initial estimate), bone uniformly, the average μ-value uniformly (IAM magnitude initialization method), and the perfect spatial μ-distribution but with a wrong magnitude (initialization in terms of distribution). 3D GATE simulation was also performed for the chest phantom under a typical clinical scanning condition, and the simulated data were reconstructed with a fully corrected list-mode TOF-MLAA algorithm with various initial estimates. The accuracy of the average μ-values within the brain, chest, and abdomen regions obtained from the MR derived μ-maps was also evaluated using computed tomography μ-maps as the gold-standard. Results: The estimated μ-map with the initialization in terms of magnitude (i.e., average μ-value) was observed to reach the reference more quickly and naturally as compared to all other cases. Both 2D and 3D GATE simulations produced similar results, and it was observed that the proposed IAM approach can produce quantitative μ-map/emission when the corrections for physical effects such as scatter and randoms were included. The average μ-value obtained from MR derived μ-map was accurate within 5% with corrections for bone, fat, and uniform lungs. Conclusions: The proposed IAM-TOF-MLAA can produce quantitative μ-map without any calibration provided that there are sufficient counts in the measured data. For low count data, noise reduction and additional regularization/rescaling techniques need to be applied and investigated. The average μ-value within the object is prior information which can be extracted from MR and patient database, and it is feasible to obtain accurate average μ-value using MR derived μ-map with corrections as demonstrated in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-103: Analysis of Hepatitis B Virus Reactivation After Conformal Radiotherapy in Patients with Hepatocellular Carcinoma Using the Lyman NTCP Model

Purpose: The aim of this research was to investigate the feasibility of Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model in analyzing hepatitis B virus (HBV) reactivation in patients receiving conformal radiotherapy for patients with hepatocellular carcinoma (HCC). Methods: Between June 2009 and June 2012, 108 HBV-related HCC patients (90 were specifically selected and 18 patients were excluded) treated with conformal RT at three centers were enrolled in this retrospective study. They were all diagnosed as HCC by pathology or cytology. All 90 patients were followed up to September 2013 with a median follow-up time of 25.2 months. The parameters (TD50 (1), n, and m) of the modified LKB NTCP model were derived using maximum likelihood estimation. Bootstrap and leave-one-out were employed to test the generalizability of the results for use in a general population. Results: The incidences of complications in the study population were as follows: radiation-induced liver diseases (RILD) were 17.6%, HBV reactivation was 24.8%, and HBV reactivation-induced hepatitis was 22.7%, respectively. In multivariate analysis, the NTCP (p<0.001), and V20 were associated with HBV reactivation. TD50 (1), m and n were 42.9Gy (95% CI) (38.2–46.8), 0.14 (0.12–0.15) and 0.30 (0.2–0.33), respectively, for HBV reactivation. Bootstrap and leave-one-out results showed that the HBV parameter fits were extremely robust. Conclusion: A modified LKB NTCP model has been established to predict HBV reactivation for patients with HCC receiving conformal RT. The finding derives parameters set to predict potential endpoints of HBV reactivation.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-10: Tumor Metabolic Control Probability & Dose Response Mapping for Adaptive Dose Painting by Number

Purpose: Adaptive dose-painting-by-number (DPbN) requires a dose-response-mapping (DRM) obtained early in the treatment course. To obtain DRM, voxel-by-voxel tumor dose response needs to be quantified. Our recent study has demonstrated that voxel-by-voxel radio-sensitivity of patient tumor can be determined using tumor-metabolic-ratio measured early during the treatment using FDG-PET images. In this study, the measurements were utilized to construct tumor metabolic control probability (TMCP) and DRM for DPbN. Methods: FDG-PET/CT images of 18 HN cancer patients obtained pre- and weekly during the treatment were used. Spatial parametric images of tumor-metabolic-ratio (dSUV) were constructed following voxel-by-voxel deformable image registration. Each voxel value in dSUV was a function of baseline SUV and delivered dose. Utilizing all values of dSUV in the controlled tumor group at the last treatment week, a cut-off function between the baseline SUV and dSUV was formed, and applied in early treatment days on dSUV of all tumors to model the TMCP. At the treatment week k, TMCP was constructed with respect to the tumor voxel dSUV appeared at the week using the maximum likelihood estimation for all dose levels, and used for DRM construction. Results: TMCPs estimated in the week 2 & 3 have D{sub 50}=11.1∼47.6Gy; γ{sub 50}=0.55∼0.92 respectively with respect to dSUV=0.3∼1.2. The corresponding DRM between tumor voxel dSUV and the expected treatment dose has sigmoid shape. The expected treatment dose are 26∼40Gy (for 95% TMCP) for high sensitive tumor voxels with dSUV=0.3∼0.5; and 65∼110Gy for low sensitive tumor voxels with the dSUV>1.0 depending on the time of the estimation. Conclusion: TMCP can be constructed voxel-by-voxel in human tumor using multiple FDG-PET imaging obtained in early treatment days. TMCP provides a potential quantitative objective of tumor DRM for DPbN to plan the best dose, escalate or de-escalate, in tumor adaptively based on its own radio-sensitivity.

60 APPLIED LIFE SCIENCES↗

Dark matter constraints from an observation of dSphs and the LMC with the Baikal NT200

We have analyzed the neutrino events recoded in the deep-water neutrino experiment NT200 in Lake Baikal in five years of observations toward dark dwarf spheroidal galaxies (dSphs) in the southern hemisphere and the Large Magellanic Cloud (LMC). This analysis completes the series of works based on NT200 data in the search for a dark matter annihilation signal in astrophysical objects. We have found no significant excess in the number of observed events relative to the expected background from atmospheric neutrinos in all tested directions, in 22 dSphs and the LMC. For a sample of five selected dwarf galaxies we have performed a joint analysis of the data by the maximum likelihood method. We have obtained a correspondence of the observational data to the null hypothesis about the presence of only background events and established 90% confidence-level upper limits for the annihilation cross sections of dark matter particles with a mass from 30 GeV to 10 TeV in several annihilation channels both in the joint analysis of the selected sample of galaxies and in the analysis toward the LMC. The strongest constraints at a level of 7 × 10{sup –21} cm{sup 3} s{sup –1} have been obtained for the direction toward the LMC in the channel of annihilation into a pair of neutrinos.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Blind Ptychographic Phase Retrieval via Convergent Alternating Direction Method of Multipliers

Ptychography has risen as a reference X-ray imaging technique: it achieves resolutions of one billionth of a meter, macroscopic field of view, or the capability to retrieve chemical or magnetic contrast, among other features. A ptychographic reconstruction is normally formulated as a blind phase retrieval problem, where both the image (sample) and the probe (illumination) have to be recovered from phaseless measured data. In this article we address a nonlinear least squares model for the blind ptychography problem with constraints on the image and the probe by maximum likelihood estimation of the Poisson noise model. We formulate a variant model that incorporates the information of phaseless measurements of the probe to eliminate possible artifacts. Next, we propose a generalized alternating direction method of multipliers designed for the proposed nonconvex models with convergence guarantee under mild conditions, where their subproblems can be solved by fast el-ementwise operations. Numerically, the proposed algorithm outperforms state-of-the-art algorithms in both speed and image quality.

47 OTHER INSTRUMENTATION↗

Discovery of Probabilistic Dirichlet-to-Neumann Maps on Graphs

Dirichlet-to-Neumann maps enable the coupling of multiphysics simulations across computational subdomains by ensuring continuity of state variables and fluxes at artificial interfaces. We present a novel method for learning Dirichlet-to-Neumann maps on graphs using Gaussian processes, specifically for problems where the data obey a conservation law arising from an underlying partial differential equation. Our approach combines discrete exterior calculus and nonlinear optimal recovery to infer relationships between vertex and edge values. This framework yields data-driven predictions with uncertainty quantification across the entire graph, even when observations are limited to a subset of vertices and edges. By minimizing the reproducing kernel Hilbert space norm while penalizing kernel complexity through maximum likelihood estimation, our method ensures that the resulting surrogate strictly enforces conservation laws without overfitting. We demonstrate our method on two representative applications: subsurface flow in fracture networks and arterial blood flow. Finally, the results demonstrate that the method maintains high accuracy and well-calibrated uncertainty estimates even under severe data scarcity, highlighting its potential for scientific applications where limited data and reliable uncertainty quantification are critical.

Dirichlet-to-Neumann map↗

Measurement of the top-quark mass in $\mathrm{t}\overline{\mathrm{t}}$ events with dilepton final states in pp collisions at $\sqrt{s}=7\ \mbox{TeV}$

The top-quark mass is measured in proton-proton collisions at sqrt(s) = 7 TeV using a data sample corresponding to an integrated luminosity of 5.0 inverse femtobarns collected by the CMS experiment at the LHC. The measurement is performed in the dilepton decay channel t t-bar to ell+ nu[ell] b, ell- anti-nu[ell] b-bar, where ell=e,mu. Candidate top-quark decays are selected by requiring two leptons, at least two jets, and imbalance in transverse momentum. The mass is reconstructed with an analytical matrix weighting technique using distributions derived from simulated samples. Using a maximum-likelihood fit, the top-quark mass is determined to be 172.5 +/- 0.4 (stat) +/- 1.5 (syst) GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for a standard model Higgs boson produced in association with a top-quark pair and decaying to bottom quarks using a matrix element method

A search for a standard model Higgs boson produced in association with a top-quark pair and decaying to bottom quarks is presented. Events with hadronic jets and one or two oppositely charged leptons are selected from a data sample corresponding to an integrated luminosity of 19.5fb -1 collected by the CMS experiment at the LHC in pp collisions at a centre-of-mass energy of 8TeV. In order to separate the signal from the larger tt¯ + jets background, this analysis uses a matrix element method that assigns a probability density value to each reconstructed event under signal or background hypotheses. The ratio between the two values is used in a maximum likelihood fit to extract the signal yield. The results are presented in terms of the measured signal strength modifier, μ, relative to the standard model prediction for a Higgs boson mass of 125GeV. The observed (expected) exclusion limit at a 95 % confidence level is μ < 4.2 (3.3), corresponding to a best fit value μ^ = 1.2 +1.6 -1.5 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ratios of helicity amplitudes for exclusive ρ 0 electroproduction on transversely polarized protons

Exclusive ρ 0 -meson electroproduction is studied by the HERMES experiment, using the 27.6 GeV longitudinally polarized electron/positron beam of HERA and a transversely polarized hydrogen target, in the kinematic region 1.0 GeV 2 < Q 2 < 7.0 GeV 2 , 3.0 GeV < W < 6.3 GeV, and –t' < 0.4 GeV 2 . Using an unbinned maximum-likelihood method, 25 parameters are extracted. These determine the real and imaginary parts of the ratios of several helicity amplitudes describing ρ 0 -meson production by a virtual photon. The denominator of those ratios is the dominant amplitude, the nucleon-helicity-non-flip amplitude F 01/201/2 , which describes the production of a longitudinal ρ 0 -meson by a longitudinal virtual photon. The ratios of nucleon-helicity-non-flip amplitudes are found to be in good agreement with those from the previous HERMES analysis. The transverse target polarization allows for the first time the extraction of ratios of a number of nucleon-helicity-flip amplitudes to F 01/201/2 . Results obtained in a handbag approach based on generalized parton distributions taking into account the contribution from pion exchange are found to be in good agreement with these ratios. Within the model, the data favor a positive sign for the π - ρ transition form factor. By also exploiting the longitudinal beam polarization, a total of 71 ρ 0 spin-density matrix elements is determined from the extracted 25 parameters, in contrast to only 53 elements as directly determined in earlier analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for $\text {W}\text {W}$ production from double-parton interactions in proton–proton collisions at $\sqrt{s} = 13 \,\text {TeV} $ = 13TeV

A search for WW production from double-parton scattering processes using same-charge electron-muon and dimuon events is reported, based on proton-proton collision data collected at a center-of-mass energy of 13 TeV. The analyzed data set corresponds to an integrated luminosity of 77.4 fb$^{-1}$, collected using the CMS detector at the LHC in 2016 and 2017. Multivariate classifiers are used to discriminate between the signal and the dominant background processes. A maximum likelihood fit is performed to extract the signal cross section. This leads to the first evidence for WW production via double-parton scattering, with a significance of 3.9 standard deviations. The measured inclusive cross section is 1.41 $\pm$ 0.28 (stat) $\pm$ 0.28 (syst) pb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A multi-dimensional search for new heavy resonances decaying to boosted $\text{W}$ $\text{W}$, $\text{W}$ $\text{Z}$, or $\text{Z}$ $\text{Z}$ boson pairs in the dijet final state at 13 $\text {Te}\text{V}$

A search in an all-jet final state for new massive resonances decaying to $\text{ W }{}{}\text{ W }{}{}$, $\text{ W }{}{}\text{ Z }{}{}$, or $\text{ Z }{}{}\text{ Z }{}{}$ boson pairs using a novel analysis method is presented. The analysis is performed on data corresponding to an integrated luminosity of 77.3 $\,\text {fb}^{-1}$ recorded with the CMS experiment at the LHC at a centre-of-mass energy of 13 $\text {Te}\text {V}$. The search is focussed on potential narrow-width resonances with masses above 1.2 $\text {Te}\text {V}$, where the decay products of each $\text{ W }{}{}$ or $\text{ Z }{}{}$ boson are expected to be collimated into a single, large-radius jet. The signal is extracted using a three-dimensional maximum likelihood fit of the two jet masses and the dijet invariant mass, yielding an improvement in sensitivity of up to 30% relative to previous search methods. No excess is observed above the estimated standard model background. In a heavy vector triplet model, spin-1 ${\text {Z}}^{\prime }$ and ${\text {W}}^{\prime }$ resonances with masses below 3.5 and 3.8 $\text {Te}\text {V}$, respectively, are excluded at 95% confidence level. In a bulk graviton model, upper limits on cross sections are set between 27 and 0.2 $\,\text {fb}$ for resonance masses between 1.2 and 5.2 $\text {Te}\text {V}$, respectively. The limits presented in this paper are the best to date in the dijet final state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of single top-quark production in association with a W boson in the single-lepton channel at $\sqrt{s} = 8\,\text {TeV}$ with the ATLAS detector

The production cross-section of a top quark in association with a W boson is measured using proton–proton collisions at √s = 8TeV. The dataset corresponds to an integrated luminosity of 20.2 fb –1 , and was collected in 2012 by the ATLAS detector at the Large Hadron Collider at CERN. The analysis is performed in the single-lepton channel. Events are selected by requiring one isolated lepton (electron or muon) and at least three jets. A neural network is trained to separate the tW signal from the dominant tt¯ background. The cross-section is extracted from a binned profile maximum-likelihood fit to a two-dimensional discriminant built from the neural-network output and the invariant mass of the hadronically decaying W boson. The measured cross-section is σ tW = 26 ± 7pb, in good agreement with the Standard Model expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shot-noise-induced lower temperature limit of the nonneutral plasma parallel temperature diagnostic

Abstract We develop a new algorithm to estimate the temperature of a nonneutral plasma in a Penning-Malmberg trap. The algorithm analyzes data obtained by slowly lowering a voltage that confines one end of the plasma and collecting escaping charges, and is a maximum likelihood estimator based on a physically-motivated model of the escape protocol presented in (Beck in Measurement of the magnetic and temperature dependence of the electron-electron anisotropic temperature relaxation rate. PhD thesis, 1990). Significantly, our algorithm may be used on single-count data, allowing for improved fits with low numbers of escaping electrons. This is important for low-temperature plasmas such as those used in antihydrogen trapping. We perform a Monte Carlo simulation of our algorithm, and assess its robustness to intrinsic shot noise and external noise. The assumptions in this paper allow for a lower bound for measurable plasma temperatures of approximately $3\,\mathrm{K}$ 3 K for plasmas of length $1\,\mathrm{cm}$ 1 cm , with approximately 100 particle counts needed for an accuracy of $\pm 10 \%$ ± 10 % .

Zhong, Adrianne (ORCID:0000000162618736)↗

First measurements of the {rho}{sup 3} spin density matrix elements in {gamma}p --> p {omega} using CLAS at JLAB

In an effort towards a ''complete'' experiment for the ω meson, we present studies from an experiment with an unpolarized target and a circularly polarized photon beam (g1c), carried out using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. The experiment was analyzed using an extended maximum likelihood fit with partial wave amplitudes. New likelihood functions were calculated to account for the polarization of the photon beam. Both circular and linear polarizations are explored. The results of these fits are then used to project out the spin density matrix for the {omega}. First measurements of the {rho}{sup 3} spin density matrix elements will be presented using this method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adsorptive Transport of Noble Gas Tracers in Porous Media

The transport of noble gas radionuclides in porous media is relevant to the detection of underground nuclear detonations as well as the sequestration of reprocessing off-gases. However, in field tests releasing radioxenon underground, the quantity of radioxenon observed at the surface has fallen well below expectations1. This study examined the diffusivity of noble gases (Kr and Xe) and the inert molecular gas sulfur hexafluoride (SF6) in porous media to observe any unexpected behavior. To replicate the transport of radiogenic noble gases in underground media, a two-bulb gaseous diffusion apparatus was constructed. The two bulbs are connected with a column of 10-30 Ottawa sand and ordinary atmosphere filled both the bulbs and pore spaces. The tracer gases were diluted in an isolated bulb to approximately 1000 ppm. Once released, the gases were allowed to diffuse through the column. Aliquots were withdrawn at regular time intervals from both bulbs and concentrations were quantified using a Shimadzu QP2010 SE gas chromatograph-mass spectrometer. The effective diffusivity was then calculated using a maximum likelihood estimate on the quasi-steady state model.

Paul, Matthew R.↗