Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

In-flight transition measurement on a 10 deg cone at Mach numbers from 0.5 to 2.0

Boundary layer transition measurements were made in flight on a 10 deg transition cone tested previously in 23 wind tunnels. The cone was mounted on the nose of an F-15 aircraft and flown at Mach numbers room 0.5 to 2.0 and altitudes from 1500 meters (5000 feet) to 15,000 meters (50,000 feet), overlapping the Mach number/Reynolds number envelope of the wind tunnel tests. Transition was detected using a traversing pitot probe in contact with the surface. Data were obtained near zero cone incidence and adiabatic wall temperature. Transition Reynolds number was found to be a function of Mach number and of the ratio of wall temperature to adiabatic all temperature. Microphones mounted flush with the cone surface measured free-stream disturbances imposed on the laminar boundary layer and identified Tollmien-Schlichting waves as the probable cause of transition. Transition Reynolds number also correlated with the disturbance levels as measured by the cone surface microphones under a laminar boundary layer as well as the free-stream impact.

Fisher, D. F.↗

Multi-Element Unstructured Analyses of Complex Valve Systems

The safe and reliable operation of high pressure test stands for rocket engine and component testing places an increased emphasis on the performance of control valves and flow metering devices. In this paper, we will present a series of high fidelity computational analyses of systems ranging from cryogenic control valves and pressure regulator systems to cavitating venturis that are used to support rocket engine and component testing at NASA Stennis Space Center. A generalized multi-element framework with sub-models for grid adaption, grid movement and multi-phase flow dynamics has been used to carry out the simulations. Such a framework provides the flexibility of resolving the structural and functional complexities that are typically associated with valve-based high pressure feed systems and have been difficult to deal with traditional CFD methods. Our simulations revealed a rich variety of flow phenomena such as secondary flow patterns, hydrodynamic instabilities, fluctuating vapor pockets etc. In the paper, we will discuss performance losses related to cryogenic control valves, and provide insight into the physics of the dominant multi-phase fluid transport phenomena that are responsible for the choking like behavior in cryogenic control elements. Additionally, we will provide detailed analyses of the modal instability that is observed in the operation of the dome pressure regulator valve. Such instabilities are usually not localized and manifest themselves as a system wide phenomena leading to an undesirable chatter at high flow conditions.

Sulyma, Peter↗

Active beam position stabilization of pulsed lasers for long-distance ion profile diagnostics at the Spallation Neutron Source (SNS)

A high peak-power Q-switched laser has been used to monitor the ion beam profiles in the superconducting linac at the Spallation Neutron Source (SNS). The laser beam suffers from position drift due to movement, vibration, or thermal effects on the optical components in the 250-meter long laser beam transport line. We have designed, bench-tested, and implemented a beam position stabilization system by using an Ethernet CMOS camera, computer image processing and analysis, and a piezo-driven mirror platform. The system can respond at frequencies up to 30 Hz with a high position detection accuracy. With the beam stabilization system, we have achieved a laser beam pointing stability within a range of 2 rad (horizontal) to 4 rad (vertical), corresponding to beam drifts of only 0.5 mm 1 mm at the furthest measurement station located 250 meters away from the light source.

43 PARTICLE ACCELERATORS↗

An ampere-hour meter for batteries

Up-down counter records charge as well as discharge in tests of rechargeable batteries. System uses reversible counter preset to represent 100% charge. As battery discharges, total count decreases; as battery is recharged, counter moves back to 100% indication.

Eklund, B. D.↗

An eight-meter inflatable reflectarray antenna and its inflatable/self-rigidizable booms

This paper presents the analysis and test results related to buckling capability, modal characteristics, and thermal expansion coefficient of STR aluminum laminate inflatable/self-rigidizable booms with lengths up to 10 metes. STR booms are fundamental building blocks of space inflatable/self-rigidizable reflectarray antennas. These boom characteristics are essential for analyzing structural integrity, in orbit dynamic response, and in orbit thermal distortion of the 8-mter reflectarray antenna. Distinct advantages of the STR booms will also be identified and presented by this paper.

membranes↗

Northwest Open Automated Demand Response Technology Demonstration Project

Lawrence Berkeley National Laboratory (LBNL) and the Demand Response Research Center (DRRC) performed a technology demonstration and evaluation for Bonneville Power Administration (BPA) in Seattle City Light's (SCL) service territory. This report summarizes the process and results of deploying open automated demand response (OpenADR) in Seattle area with winter morning peaking commercial buildings. The field tests were designed to evaluate the feasibility of deploying fully automated demand response (DR) in four to six sites in the winter and the savings from various building systems. The project started in November of 2008 and lasted 6 months. The methodology for the study included site recruitment, control strategy development, automation system deployment and enhancements, and evaluation of sites participation in DR test events. LBNL subcontracted McKinstry and Akuacom for this project. McKinstry assisted with recruitment, site survey collection, strategy development and overall participant and control vendor management. Akuacom established a new server and enhanced its operations to allow for scheduling winter morning day-of and day-ahead events. Each site signed a Memorandum of Agreement with SCL. SCL offered each site $3,000 for agreeing to participate in the study and an additional $1,000 for each event they participated. Each facility and their control vendor worked with LBNL and McKinstry to select and implement control strategies for DR and developed their automation based on the existing Internet connectivity and building control system. Once the DR strategies were programmed, McKinstry commissioned them before actual test events. McKinstry worked with LBNL to identify control points that can be archived at each facility. For each site LBNL collected meter data and trend logs from the energy management and control system. The communication system allowed the sites to receive day-ahead as well as day-of DR test event signals. Measurement of DR was conducted using three different baseline models for estimation peak load reductions. One was three-in-ten baseline, which is based on the site electricity consumption from 7 am to 10 am for the three days with the highest consumption of the previous ten business days. The second model, the LBNL outside air temperature (OAT) regression baseline model, is based on OAT data and site electricity consumption from the previous ten days, adjusted using weather regressions from the fifteen-minute electric load data during each DR test event for each site. A third baseline that simply averages the available load data was used for sites less with less than 10 days of historical meter data. The evaluation also included surveying sites regarding any problems or issues that arose during the DR test events. Question covered occupant comfort, control issues and other potential problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nearshore coastal mapping

Two test sites of different water quality and bottom topography were used to test for maximum water depth penetration using the Skylab S-192 MSS for measurement of nearshore coastal bathymetry. Sites under investigation lie along the Lake Michigan coastline where littoral transport acts to erode sand bluffs and endangers developments along 1,200 miles of shore, and on the west coast of Puerto Rico where unreliable shoal location and depth information constitutes a safety hazard to navigation. The S-192 and S-190A and B provide data on underwater features because of water transparency in the blue/green portion of the spectrum. Depth of 20 meters were measured with the S-192 in the Puerto Rico test site. The S-190B photography with its improved spatial resolution clearly delineates the triple sand bar topography in the Lake Michigan test site. Several processing techniques were employed to test for maximum depth measurement with least error. The results are useful for helping to determine an optimum spectral bandwidth for future space sensors that will increase depth measurements for different water attenuation conditions where a bottom reflection is detectable.

Polcyn, F. C.↗

Goldstone field test activities: Target search

In March of this year prototype SETI equipment was installed at DSS13, the 26 meter research and development antenna at NASA's Goldstone complex of satellite tracking dishes. The SETI equipment will remain at this site at least through the end of the summer so that the hardware and software developed for signal detection and recognition can be fully tested in a dynamic observatory environment. The field tests are expected to help understand which strategies for observing and which signal recognition algorithms perform best in the presence of strong man-made interfering signals (RFI) and natural astronomical sources.

Tarter, J.↗

The 15-meter antenna performance optimization using an interdisciplinary approach

A 15-meter diameter deployable antenna has been built and is being used as an experimental test system with which to develop interdisciplinary controls, structures, and electromagnetics technology for large space antennas. The program objective is to study interdisciplinary issues important in optimizing large space antenna performance for a variety of potential users. The 15-meter antenna utilizes a hoop column structural concept with a gold-plated molybdenum mesh reflector. One feature of the design is the use of adjustable control cables to improve the paraboloid reflector shape. Manual adjustment of the cords after initial deployment improved surface smoothness relative to the build accuracy from 0.140 in. RMS to 0.070 in. Preliminary structural dynamics tests and near-field electromagnetic tests were made. The antenna is now being modified for further testing. Modifications include addition of a precise motorized control cord adjustment system to make the reflector surface smoother and an adaptive feed for electronic compensation of reflector surface distortions. Although the previous test results show good agreement between calculated and measured values, additional work is needed to study modelling limits for each discipline, evaluate the potential of adaptive feed compensation, and study closed-loop control performance in a dynamic environment.

Grantham, William L.↗

Radiative properties of advanced spacecraft heat shield materials

Experimental results are presented to show the effects of simulated reentry exposure by convective heating and by radiant heating on spectral and total emittance of statically oxidized Inconel 617 and Haynes HS188 superalloys to 1260 K and a silicide coatea (R512E) columbium 752 alloy to 1590 K. Convective heating exposures were conducted in a supersonic arc plasma wind tunnel using a wedge-shaped specimen configuration. Radiant tests were conducted at a pressure of .003 atmospheres of dry air at a flow velocity of several meters per second. Convective heating specimens were subjected to 8, 20, and 38 15-min heating cycles, and radiant heating specimens were tested for 10, 20, 50, and 100 30-min heating cycles. Changes in radiative properties are explained in terms of changes in composition resulting from simulated reentry tests. The methods used to evaluate morphological, compositional and crystallographic changes include: Auger electron spectroscopy; scanning electron microscopy; X-ray diffraction analysis; and electron microprobe analysis.

Cunnington, G. R.↗

Constancy of built-in luminance meter measurements in diagnostic displays

Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49 336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25 000 BLH and those with more than 25 000 BLH. Bias between meters was also evaluated. Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35 000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25 000 and greater than 25 000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35 000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermomechanical model to assess stresses developed during elevated-temperature cleaning of coated optics

A thermomechanical model is developed to estimate the stress response of an oxide coating to elevated-temperature chemical cleaning. Using a hafnia–silica multilayer dielectric pulse compressor grating as a case study, we demonstrate that substrate thickness can strongly affect the thermal stress response of the thin-film coating. As a result, coatings on large, thick substrates may be susceptible to modes of stress-induced failure (crazing or delamination) not seen in small parts. We compare the stress response of meter-scale optics to the behavior of small-scale test or “witness” samples, which are expected to be representative of their full-size counterparts. The effects of materials selection, solution temperature, and heating/cooling rates are explored. Extending the model to other situations, thermal stress results are surveyed for various combinations of commonly used materials. Seven oxide coatings (hafnia, silica, tantala, niobia, alumina, and multilayers of hafnia–silica and alumina–silica) and three glass substrates (BK7, borosilicate float glass, and fused silica) are examined to highlight some interesting results.

Liddell, H. H.↗

Variable load automatically tests dc power supplies

Continuously variable load automatically tests dc power supplies over an extended current range. External meters monitor current and voltage, and multipliers at the outputs facilitate plotting the power curve of the unit.

Burke, H. C., Jr.↗

Evaluation of a hemispherical head flow direction sensor for inlet duct measurements

A hemispherical head flow direction sensor was tested in a wind tunnel to evaluate its effectiveness for measuring dynamic duct flow direction angles of plus and minus 27 degrees. The tests were conducted at Reynolds numbers of 3.8 million per meter (1.0 million per foot) and 4.92 million per meter (1.5 million per foot) and at Mach numbers from 0.30 to 0.70. The design criteria for the probe are discussed and the wind tunnel results are presented. Three techniques for deriving the flow angles are described.

Bennett, D. L.↗

Experimental results for the transpired turbulent boundary layer in an adverse pressure gradient

The fluid mechanics of transpired incompressible turbulent boundary layers under zero and adverse pressure gradient conditions is investigated using an open-ended wind tunnel with a porous floor in the test section and a secondary air system for supply and metering of the transpiration air. All velocity profiles and turbulence profiles are obtained by linearized constant-temperature hot-wire anemometry. The wall shear stress is determined by measuring the shear stress away from the wall and extrapolating to the wall by integrating the boundary layer equations for the shear-stress profile. Equilibrium boundary layers are obtained when the transpiration velocity is varied such that the blowing parameter and the Clauser pressure gradient parameter are held constant. The experimental results obtained are presented in tabular and graphical forms.

Andersen, P. S.↗

Calibration of a pitot-static rake

A five-element pitot-static rake was tested to confirm its accuracy and determine its suitability for use at Langley during low-speed tunnel calibration primarily at full-scale tunnel. The rake was tested at one airspeed of 74 miles per hour (33 meters per second) and at pitch and yaw angles of 0 to + or - 20 degrees in 4 deg increments.

Stump, H. P.↗

Review of Canadian experience in precise gravimetry

Results of gravity observations made in Canada from 1974 to 1978 reviewed, in order to estimate the true accuracy of present-day gravimetry and thereby assess the potential capability of the method for detecting crustal movements. The standard error of the mean of ties is 15-20 nm/s squared. Inter-instrument comparisons and other tests show, however, that a more realistic estimate of D meter accuracy is 30-40 nm/s squared. This accuracy can only be maintained over the long term where uncertainties in gravimeter calibration curves are minimized by resetting to the same dial reading on the resurveys. A further deterioration in accuracy to 40-50 nm/s squared occurs where reliance is placed on presently available D meter calibration curves. Despite the present accuracy limitations significant time variations in gravity of 100-150 nm/s squared are seen over spatial scales of 10-100 kilometers in Canada over a period of several months.

Lambert, A.↗