Recent advances in control of nonlinear and distributed parameter systems, robust control, and aerospace control applications; Proceedings of the Symposium, ASME Winter Annual Meeting, Chicago, IL, Nov. 27-Dec. 2, 1988

Papers are presented on the control of distributed parameter systems using the coprime factorization approach, a hierarchy of geometrically exact models of rotating beams, and the temperature stability of a flux modulated radiant slab. Also considered are a network representation for robots, recovery from controller bounding, and the design of controllers for robust tracking and model following. Other topics include an active control law synthesis for flexible aircraft, the low-order control of large aerospsace structures using residual model filters, and a comparison of component cost methods for component model reduction.

Bentsman, Joseph↗

Global-scale modes of surface temperature variability on interannual to century timescales

Using 100 years of global temperature anomaly data, we have performed a singluar value decomposition of temperature variations in narrow frequency bands to isolate coherent spatio-temporal modes of global climate variability. Statistical significance is determined from confidence limits obtained by Monte Carlo simulations. Secular variance is dominated by a globally coherent trend; with nearly all grid points warming in phase at varying amplitude. A smaller, but significant, share of the secular variance corresponds to a pattern dominated by warming and subsequent cooling in the high latitude North Atlantic with a roughly centennial timescale. Spatial patterns associated with significant peaks in variance within a broad period range from 2.8 to 5.7 years exhibit characteristic El Nino-Southern Oscillation (ENSO) patterns. A recent transition to a regime of higher ENSO frequency is suggested by our analysis. An interdecadal mode in the 15-to-18 years period and a mode centered at 7-to-8 years period both exhibit predominantly a North Atlantic Oscillation (NAO) temperature pattern. A potentially significant decadal mode centered on 11-to-12 years period also exhibits an NAO temperature pattern and may be modulated by the century-scale North Atlantic variability.

Mann, Michael E.↗

Fault-Tolerant Heat Exchanger

A compact, lightweight heat exchanger has been designed to be fault-tolerant in the sense that a single-point leak would not cause mixing of heat-transfer fluids. This particular heat exchanger is intended to be part of the temperature-regulation system for habitable modules of the International Space Station and to function with water and ammonia as the heat-transfer fluids. The basic fault-tolerant design is adaptable to other heat-transfer fluids and heat exchangers for applications in which mixing of heat-transfer fluids would pose toxic, explosive, or other hazards: Examples could include fuel/air heat exchangers for thermal management on aircraft, process heat exchangers in the cryogenic industry, and heat exchangers used in chemical processing. The reason this heat exchanger can tolerate a single-point leak is that the heat-transfer fluids are everywhere separated by a vented volume and at least two seals. The combination of fault tolerance, compactness, and light weight is implemented in a unique heat-exchanger core configuration: Each fluid passage is entirely surrounded by a vented region bridged by solid structures through which heat is conducted between the fluids. Precise, proprietary fabrication techniques make it possible to manufacture the vented regions and heat-conducting structures with very small dimensions to obtain a very large coefficient of heat transfer between the two fluids. A large heat-transfer coefficient favors compact design by making it possible to use a relatively small core for a given heat-transfer rate. Calculations and experiments have shown that in most respects, the fault-tolerant heat exchanger can be expected to equal or exceed the performance of the non-fault-tolerant heat exchanger that it is intended to supplant (see table). The only significant disadvantages are a slight weight penalty and a small decrease in the mass-specific heat transfer.

Izenson, Michael G.↗

In-depth Analysis of LISA Pathfinder Performance Results: Time Evolution, Noise Projection, Physical Models, and Implications for LISA

We present an in-depth analysis of the LISA Pathfinder differential acceleration performance over the entire course of its science operations, spanning approximately 500 days. We find: (1) The evolution of the Brownian noise that dominates the acceleration amplitude spectral density (ASD), for frequencies f≳1 mHz, is consistent with the decaying pressure due to the outgassing of a single gaseous species. (2) Between f=36 μHz and 1 mHz, the acceleration ASD shows a 1/f tail in excess of the Brownian noise of almost constant amplitude, with ≃20% fluctuations over a period of a few days, with no particular time pattern over the course of the mission. (3) At the lowest considered frequency of f=18 μHz, the ASD significantly deviates from the 1/f behavior, because of temperature fluctuations that appear to modulate a quasistatic pressure gradient, sustained by the asymmetries of the outgassing pattern. We also present the results of a projection of the observed acceleration noise on the potential sources for which we had either a direct correlation measurement or a quantitative estimate from dedicated experiments. These sources account for approximately 40% of the noise power in the 1/f tail. Finally, we analyze the possible sources of the remaining unexplained fraction and identify the possible measures that may be taken to keep those under control in LISA.

M Armano↗

Low-Cost, Highly-Integrated Silicon Carbide (SiC) Multichip Power Modules (MCPMs) for Plug-In Hybrid Electric Vehicles (PHEVs)

A high power (6 kW), efficient (> 95%), ultra-power dense (5.0 kW/L and 3.8 kW/kg), Level 2 isolated on-board vehicular battery charger that utilizes silicon carbide (SiC) power devices for application in electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEVs) was developed. The heart of the charger is a high-frequency capable (> 1 MHz) multi-chip power module allowing for high junction temperature (> 200 °C) operation which, when coupled with a high switching frequency, allows for an order of magnitude increase in power density, while boasting an increase in system efficiency over currently used technologies.

33 ADVANCED PROPULSION SYSTEMS↗

Solar Photovoltaic DC Systems: Basics and Safety: Preprint

Solar Photovoltaic (PV) systems are common and growing with 42.4 GW installed capacity in U.S. (almost 15 GW added in 2016). This paper will help electrical workers, and emergency responders understand the basic operating principles and hazards of PV DC arrays. We briefly discuss the following aspects of solar photovoltaic (PV) DC systems: the effects of solar radiation and temperature on output power; PV module testing standards; common system configurations; a simple PV array sizing example; NEC guidelines and other safety features; DC array commissioning, periodic maintenance and testing; arc-flash hazard potential; how electrical workers and emergency responders can and do work safely around PV arrays; do moonlight and artificial lighting pose a real danger; typical safe operating procedures; and other potential DC-system hazards to be aware of. We also present some statistics on PV DC array electrical incidents and injuries. Safe PV array operation is possible with a good understanding of PV DC arrays basics and having good safe operating procedures in place.

14 SOLAR ENERGY↗

Japan-US Joint Research Project PHENIX (2013–2018); Heat Transfer Tests, Neutron Irradiation and Post-Irradiation Examinations for Development of He-Cooled Tungsten Divertor

The goal of the Japan-US joint research project PHENIX (2013–2018) is to understand the feasibility of He-cooled W divertor for DEMO applications. To achieve this goal, the project has three major objectives: (1) to understand heat transfer in a divertor module cooled with high-temperature and high-pressure He gas, (2) to establish database on thermomechanical properties of W materials after high temperature (~500, ~800 and ~1100 °C) neutron irradiation with fusion-relevant energy spectrum, and (3) to clarify tritium (T) trapping and permeation in neutron-irradiated W materials. Heat transfer tests for a He-cooled modular divertor with multi-jet (HEMJ) have been performed, and the problem of heat transfer degradation by re-laminarization was identified.The irradiation capsule with thermal neutron shielding was designed for high temperature neutron irradiation in the High Flux Isotope Reactor (HFIR), Oak Ridge National Laboratory (ORNL) with fusion-relevant transmutation. The expected damage level is 1–1.5 displacements per atom (dpa). Heat load resistance, thermal conductivity, mechanical properties and microstructures are examined in ORNL after the irradiation. Mechanical properties of W single crystal samples irradiated with neutrons in HFIR at 90– 850 °C without thermal neutron shielding were examined for comparison. Significant hardening was observed after irradiation to >1 dpa. Microstructural examinations revealed that the hardening was mainly caused by formation of irradiation-induced precipitates consisting of W, Re and Os. Comparison with new samples irradiated in the capsule with thermal neutron shielding will show the effects of irradiation temperatures and transmutation elements. Retention and permeation of hydrogen isotopes including T in neutron-irradiated samples are examined in Idaho National Laboratory, and permeation of H and D in samples damaged with surrogate irradiations (heavy ions, electrons, etc.) is measured in Sandia National Laboratories, Livermore, to study hydrogen-defect interactions in wider conditions. The measurement of D retention in the single crystal W sample after neutron irradiation to 0.1 dpa at 360 °C and subsequent plasma exposure at 400 °C showed significant trapping effects by radiation-induced defects.

Ueda, Yoshio↗

Influence of Irradiation-induced Microstructural Defects on Thermal Transport in Single Crystal Thorium Dioxide

Microstructural defects formed as a result of fission fragment damage are known to drastically alter thermal conductivity, a fuel property that governs the efficiency of a nuclear reactor. A fundamental understanding of radiation-induced effects on thermal transport is critical for the development of advanced fuels. Ion-irradiation has widely been used to simulate the effects of neutron-irradiation by seeding atomic-to-nanoscale defects of controllable size and density. In this work, we investigate the influence of microstructural defects, induced by ion-irradiation, on the thermal properties of single crystal thorium dioxide samples grown using the hydrothermal technique. The samples were irradiated using 2 MeV protons at room temperature. A laser-based modulated thermoreflectance technique was used to measure the thermal diffusivity and conductivity within the damaged ThO2 region. The experimentally measured thermal properties were compared with Boltzmann Transport Equation predictions, to determine the impact of various defect types on the thermal properties of ThO2.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Caustic Recycling Pilot Unit to Separate Sodium from LLW at Hanford Site - 12279

As part of the Department of Energy (DOE) sponsored Advanced Remediation Technologies initiative, a scheme was developed to combine Continuous Sludge Leaching (CSL), Near-Tank Cesium Removal (NTCR), and Caustic Recycling Unit (CRU) using Ceramatec technology, into a single system known as the Pilot Near-Tank Treatment System (PNTTS). The Cesium (Cs) decontaminated effluent from the NTCR process will be sent to the caustic recycle process for recovery of the caustic which will be reused in another cycle of caustic leaching in the CSL process. Such an integrated mobile technology demonstration will give DOE the option to insert this process for sodium management at various sites in Hanford, and will minimize the addition of further sodium into the waste tanks. This allows for recycling of the caustic used to remove aluminum during sludge washing as a pretreatment step in the vitrification of radioactive waste which will decrease the Low Level Waste (LLW) volume by as much as 39%. The CRU pilot process was designed to recycle sodium in the form of pure sodium hydroxide. The basis for the design of the 1/4 scale pilot caustic recycling unit was to demonstrate the efficient operation of a larger scale system to recycle caustic from the NTCR effluent stream from the Parsons process. The CRU was designed to process 0.28 liter/minute of NTCR effluent, and generate 10 M concentration of 'usable' sodium hydroxide. The proposed process operates at 40 deg. C to provide additional aluminum solubility and then recover the sodium hydroxide to the point where the aluminum is saturated at 40 deg. C. A system was developed to safely separate and vent the gases generated during operation of the CRU with the production of 10 M sodium hydroxide. Caustic was produced at a rate between 1.9 to 9.3 kg/hr. The CRU was located inside an ISO container to allow for moving of the unit close to tank locations to process the LLW stream. Actual tests were conducted with the NTCR effluent simulant from the Parsons process in the CRU. The modular CRU is easily scalable as a standalone system for caustic recycling, or for NTTS integration or for use as an In-Tank Treatment System to process sodium bearing waste to meet LLW processing needs at the Hanford site. The standalone pilot operation of the CRU to recycle sodium from NTCR effluent places the technology demonstration at TRL level 6. Multiple operations were performed with the CRU to process up to 500 gallons of the NTCR effluent and demonstrate an efficient separation of up to 70 % of the sodium without solids precipitation while producing 10 M caustic. Batch mode operation was conducted to study the effects of chemistry variation, establish the processing rate, and optimize the process operating conditions to recycle caustic from the NTCR effluent. The performance of the CRU was monitored by tracking the density parameter to control the concentration of caustic produced. Different levels of sodium were separated in tests from the effluent at a fixed operating current density and temperature. The voltage of the modules remained stable during the unit operation which demonstrated steady operation to separate sodium from the NTCR effluent. The sodium transfer current efficiency was measured in testing based on the concentration of caustic produced. Measurements showed a current efficiency of 99.8% for sodium transfer from the NTCR effluent to make sodium hydroxide. The sodium and hydroxide contents of the anolyte (NTCR feed) and catholyte (caustic product) were measured before and after each batch test. In two separate batch tests, samples were taken at different levels of sodium separation and analyzed to determine the stability of the NTCR effluent after sodium separation. The stability characteristics and changes in physical and chemical properties of the NTCR effluent chemistry after separation of sodium hydroxide as a function of storage time were evaluated. Parameters such as level of precipitated alumina, total alkalinity, analysis of Al, Na, K, Cs, Fe, OH, nitrate, nitrite, total dissolved and undissolved solids, viscosity, density, and other parameters of the NTCR effluent were measured. Changes in rheology and properties of NTCR stream to support downstream handling of the effluent after sodium separation was the basis for the analysis. The results show that the NTCR effluent is stable without the precipitation of aluminum hydroxide after 70% of the sodium was separated from the effluent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of wall thickness on the flow instability of supercritical pressure water in a tube - 18568

The subcritical steam generators in the current high-temperature-reactor pebble-bed module, HTR-PM, in China can be replaced by supercritical steam generators to better coordinate the reactors and the supercritical steam turbines to improve thermal efficiencies with no phase change at supercritical pressures. This study numerically studied the heat transfer and flow instability of supercritical pressure water in a vertical tube with zero- and finite-thickness walls. The effect of the wall thickness on the heat transfer of supercritical pressure water at steady state was negligible. In the transient calculations, the fluid flow rate oscillated intensely beyond a certain heat flux with zero-thickness wall, while the flows in the tube with the finite-thickness walls acted totally different. The wall properties including the density and specific heat were varied to analyze why the oscillations were suppressed when the finite-thickness wall was considered in the calculation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Digitally Controlled High Availability Power Supply

This paper reports the design and test results on novel topology, high-efficiency, and low operating temperature, 1,320-watt power modules for high availability power supplies. The modules permit parallel operation for N+1 redundancy with hot swap capability. An embedded DSP provides intelligent start-up and shutdown, output regulation, general control and fault detection. PWM modules in the DSP drive the FET switches at 20 to 100 kHz. The DSP also ensures current sharing between modules, synchronized switching, and soft start up for hot swapping. The module voltage and current have dedicated ADCs (>200 kS/sec) to provide pulse-by-pulse output control. A Dual CAN bus interface provides for low cost redundant control paths. Over-rated module components provide high reliability and high efficiency at full load. Low on-resistance FETs replace conventional diodes in the buck regulator. Saturable inductors limit the FET reverse diode current during switching. The modules operate in a two-quadrant mode, allowing bipolar output from complimentary module groups. Controllable, low resistance FETs at the input and output provide fault isolation and allow module hot swapping.

43 PARTICLE ACCELERATORS↗

Candidate materials for advanced fire-resistant photovoltaic modules

A cooperative, cost-sharing research effort to develop a technology base required to construct fire-ratable photovoltaic modules has resulted in the identification of several high-temperature, back-surface candidate materials capable of raising the fire-resistance of modules using hydrocarbon encapsulants to Class A and B levels. Advanced experimental module configurations have been developed using back surfaces consisting of Kapton, Tedlar laminates, metal-foils, and fiberglass materials with high-temperature coatings. Test results (October 1984; March 1985; May 1985; and October 1985) indicate that several of these advanced module configurations are capable of achieving Class B fire-resistance levels, while a few configurations can achieve Class A levels. The paper summarizes activities to date, discussing flammability failure mechanisms, time-temperature profiles, and results of Block V environmental exposure tests of a candidate material suitable for both Class B and Class A fire-resistance levels.

Sugimura, R. S.↗

Incommensurate and commensurate modulations of Ba{sub 5}RTi{sub 3}Nb{sub 7}O{sub 30} (R = La, Nd) tungsten bronzes and the ferroelectric domain structures

Incommensurate and commensurate structural modulations of Ba{sub 5}RTi{sub 3}Nb{sub 7}O{sub 30} (R = La, Nd) tungsten bronze ceramics were investigated by using a cooling holder equipped transmission electron microscopy in the temperature range from 100 K to 363 K. The incommensurate modulation was observed in both Ba{sub 5}LaTi{sub 3}Nb{sub 7}O{sub 30} and Ba{sub 5}NdTi{sub 3}Nb{sub 7}O{sub 30} at room temperature, while there was a transition from incommensurate tilted structure to commensurate superstructure for Ba{sub 5}NdTi{sub 3}Nb{sub 7}O{sub 30} with decreasing temperature. The incommensurate and commensurate modulations were determined by the A-site occupancy of Ba and R cations. The A-site disorder resulted in larger incommensurability parameter δ and the diffusion of the satellite reflection spots. The effect of A-site disorder on the coupling between long-range dipolar order and the commensurate modulation was also discussed. The obvious ferroelectric 180° domains with spike-like shape parallel to c axis were observed for Ba{sub 5}NdTi{sub 3}Nb{sub 7}O{sub 30}, while no macro ferroelectric domain was determined for Ba{sub 5}LaTi{sub 3}Nb{sub 7}O{sub 30}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Degradation of Photovoltaic Modules Under High Voltage Stress in the Field: Preprint

The degradation in performance for eight photovoltaic (PV) modules stressed at high voltage (HV) is presented. Four types of modules--tandem-junction and triple-junction amorphous thin-film silicon, plus crystalline and polycrystalline silicon modules--were tested, with a pair of each biased at opposite polarities. They were deployed outdoors between 2001 and 2009 with their respective HV leakage currents through the module encapsulation continuously monitored with a data acquisition system, along with air temperature and relative humidity. For the first 5 years, all modules were biased continuously at fixed 600 VDC, day and night. In the last 2 years, the modules were step-bias stressed cyclically up and down in voltage between 10 and 600 VDC, in steps of tens to hundreds of volts. This allowed characterization of leakage current versus voltage under a large range of temperature and moisture conditions, facilitating determination of leakage paths. An analysis of the degradation is presented, along with integrated leakage charge. In HV operation: the bulk silicon modules degraded either insignificantly or at rates of 0.1%/yr higher than modules not biased at HV; for the thin-film silicon modules, the added loss rates are insignificant for one type, or 0.2%/yr-0.6%/yr larger for the other type.

14 SOLAR ENERGY↗

Electric field effect in ultrathin black phosphorus

Black phosphorus exhibits a layered structure similar to graphene, allowing mechanical exfoliation of ultrathin single crystals. Here, we demonstrate few-layer black phosphorus field effect devices on Si/SiO{sub 2} and measure charge carrier mobility in a four-probe configuration as well as drain current modulation in a two-point configuration. We find room-temperature mobilities of up to 300 cm{sup 2}/Vs and drain current modulation of over 10{sup 3}. At low temperatures, the on-off ratio exceeds 10{sup 5}, and the device exhibits both electron and hole conduction. Using atomic force microscopy, we observe significant surface roughening of thin black phosphorus crystals over the course of 1 h after exfoliation.

36 MATERIALS SCIENCE↗

Significance of Landsat-7 Spacecraft Level Thermal Balance and Thermal Test for ETM+Instrument

The thermal design and the instrument thermal vacuum (T/V) test of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument were based on the Landsat-4, 5 and 6 heritage. The ETM+ scanner thermal model was also inherited from Landsat-4, 5 and 6. The temperature predictions of many scanner components in the original thermal model had poor agreement with the spacecraft and instrument integrated sun-pointing safehold (SPSH) thermal balance (T/B) test results. The spacecraft and instrument integrated T/B test led to a change of the Full Aperture Calibrator (FAC) motor stack "solar shield" coating from MIL-C-5541 to multi-layer insulation (MLI) thermal blanket. The temperature predictions of the Auxiliary Electronics Module (AEM) in the thermal model also had poor agreement with the T/B test results. Modifications to the scanner and AEM thermal models were performed to give good agreement between the temperature predictions and the test results. The correlated ETM+ thermal model was used to obtain flight temperature predictions. The flight temperature predictions in the nominal 15-orbit mission profile, plus margins, were used as the yellow limits for most of the ETM+ components. The spacecraft and instrument integrated T/B and TN test also revealed that the standby heater capacity on the Scan Mirror Assembly (SMA) was insufficient when the Earth Background Simulator (EBS) was 1 50C or colder, and the baffle heater possibly caused the coherent noise in the narrow band data when it was on. Also, the cooler cool-down was significantly faster than that in the instrument T/V test, and the coldest Cold Focal Plane Array (CFPA) temperature achieved was colder.

Choi, Michael K.↗

Phase Transitions in Lead Hafnate under High Pressure

The effect of hydrostatic pressure on phase transitions in lead hafnate (PbHfO{sub 3}) has been studied by the methods of X-ray diffraction and X-ray diffuse scattering. The measurements were performed in the temperature range of 182 < T < 316°C and the pressure range of 1.6 < P < 2.6 GPa. Four regions characterized by different X-ray diffraction patterns and corresponding to an antiferroelectric phase, phases with a long-wavelength modulation of the lead sublattice, and phases with different distortions of the oxygen sublattice are identified. In the temperature region immediately above the region of phases with a long-wavelength modulation, a temperature-dependent maximum in the distribution of diffuse scattering was detected, which means that such a modulation is formed due to condensation of an incommensurate soft mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of the DC bus link capacitors and power transistor modules in the qualification testing of PV inverters

To achieve useful, fair, and cost-effective design qualification and type approval testing for PV inverters, two procedures were developed and demonstrated to evaluate the bus link capacitors and power transistor—and where applicable, its module—for long-term reliability. We evaluate the inverter under simulated use conditions with heat run tests to find the highest operating temperatures reached by these components. The procedures are demonstrated in this study with a 4-kVA class string inverter. The maximum temperature of the DC bus link capacitors was determined to be 76.4°C when the ambient temperature was at the inverter's maximum rated temperature of 60°C with derating occurring. On the other hand, the power transistor module's maximum temperature using the heat sink temperature as the index, 92.6°C, occurred in an ambient of 40.8°C when derating was not occurring. The conditions found for upper temperatures exhibited by these components are, respectively, proposed for implementation in the dry heat and thermal cycling tests in the IEC 62093 “Power conversion equipment for photovoltaic systems – Design qualification testing” international standard draft so that the levels applied in the tests are in proportion to those experienced in the field. Finally as a result, fairer evaluation of inverter reliability is realized.