Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Asymmetries in the location of the Venus ionopause

Four large data sets of Venus ionopause observations, based on different definitions and observations by Pioneer Venus Orbiter field and particle instruments, are compared. Regardless of the definition chosen, the ionopause is observed to be higher on average at dawn than at dusk. The results of an empirical ionosphere model and a data analysis technique which minimizes orbital bias are combined to show that most or all of this asymmetry results from the effects of orbital bias and uneven sampling of solar wind conditions. However, an additional asymmetry is found in which the ionopause is displaced in the direction opposite to the motional electric field of the solar wind. This effect is attributed to asymmetric pickup of exospheric ions by the electric and magnetic fields in the magnetosheath. This ion pickup interpretation can be understood in terms of a previous observed magnetosheath magnetic field asymmetry. Quantitative analysis indicates that the transverse momentum imparted by the solar plasma to pickup particles in their initial gyration is transmitted by the magnetosheath magnetic field to the ionosphere boundary.

Phillips, J. L.↗

Determination of left ventricular volume, ejection fraction, and myocardial mass by real-time three-dimensional echocardiography

Reconstructed three-dimensional (3-D) echocardiography is an accurate and reproducible method of assessing left ventricular (LV) functions. However, it has limitations for clinical study due to the requirement of complex computer and echocardiographic analysis systems, electrocardiographic/respiratory gating, and prolonged imaging times. Real-time 3-D echocardiography has a major advantage of conveniently visualizing the entire cardiac anatomy in three dimensions and of potentially accurately quantifying LV volumes, ejection fractions, and myocardial mass in patients even in the presence of an LV aneurysm. Although the image quality of the current real-time 3-D echocardiographic methods is not optimal, its widespread clinical application is possible because of the convenient and fast image acquisition. We review real-time 3-D echocardiographic image acquisition and quantitative analysis for the evaluation of LV function and LV mass.

NASA Discipline Cardiopulmonary↗

Detailed surface analysis of incremental Centrifugal Barrel Polishing (CBP) and EP of single-crystal niobium samples.

Detailed surface analysis of incremental Centrifugal Barrel Polishing (CBP) and EP of single-crystal niobium samples. Ari Palczewski, Hui Tian, Olga Trofimova, Charles Reece Jefferson Lab, Newport News, VA 23606 We performed Centrifugal Barrel Polishing (CBP) on single crystal niobium samples housed in a stainless steel sample holder following a polishing recipe recently developed at FNAL [1]. We were able to obtain a mirror-like finish after the final stage of tumbling, although some defects and imbedded particles remain. Our presentation will discuss the initial results from the coupon study, including qualitative and quantitative analysis of the surface characteristics from each step in the CBP process, followed by HPR and well controlled incremental EP. These will include surface roughness, size and character of contaminants, surface crystal structure, and overall finish. We will discuss how the surface characteristics should guide the SRF community in exploiting or adapting the Fermi recipe; including why minimal subsequent EP is needed, and possible places for modification of the recipe to reduce polishing time. This work is authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. [1]CA Cooper, LD Cooley , ?Mirror Smooth Superconducting RF Cavities by Mechanical Polishing with Minimal Acid Use,? http://lss.fnal.gov/archive/2011/pub/fermilab-pub-11-032-td.pdf, (May 31, 2011)

Reece, Charles↗

Revealing meso-structure dynamics in additive manufacturing of energy storage via operando coherent X-ray scattering

3D printing is an emerging technology for the fabrication of energy storage devices, offering advantages over traditional manufacturing methods. However, optimization and design of such devices requires an understanding of the meso-structure formation during the 3D printing process. This study utilizes operando coherent X-ray scattering, X-ray Photon Correlation Spectroscopy (XPCS), to study the spatiotemporally-resolved far-from-equilibrium dynamics during direct ink writing 3D printing. Here, Lithium Titanate (LTO) based ink is prepared and rheologically tested for its shear-thinning properties. Two-time intensity-intensity functions are calculated to be used in subsequent quantitative analysis, which allows for an overall characterization of the dynamics, description of an initial fast decorrelation and identification of sudden rearrangements of subdomains of the sample. The results show the dynamics to be anisotropic, spatiotemporally heterogenous and marked by distinct rearrangement events, all of which impact the electrochemical performance of energy storage devices. The studied 3D printing ink is used to fabricate electrodes which are then electrochemically tested, showing good performance in cycling and retaining structural integrity. This work furthers the understanding of the far-from-equilibrium material dynamics during 3D printing, giving quantitative characterization of this process, and highlights aspects of structure formation relevant to the electrochemical performance of the resultant energy storage device.

36 MATERIALS SCIENCE↗

Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

methamphetamine, cocaine, heroin, fentanyl, atmosp↗

Active Recycling Control Through Lithium Injection in EAST

The coating of tokamak walls with thin layers of lithium has been demonstrated to reduce plasma recycling from the plasma-facing surfaces and to improve overall plasma performance. These effects, including reduced divertor D α emission, the elimination of edge-localized modes, and increased energy confinement have been observed in multiple experiments when lithium coatings are applied before plasma discharges. However, this coating technology does not extrapolate to future long-pulse devices, since the lithium coatings will be passivated by the continual plasma flux onto the surface. In order to provide active conditioning capability, a new technology has been developed that is capable of injecting lithium powder into the scrape-off layer plasma during plasma discharges, where it quickly liquefies and turns into an aerosol. The use of this “lithium dropper” is under study at the Experimental Advanced Superconducting Tokamak (EAST), where the potential benefits of real-time wall conditioning via lithium injection are being tested. Here, we present an analysis of the recycling characteristics during EAST experiments testing active lithium injection in order to assess recycling reduction and control. Lithium aerosol was injected from the top of the machine, with one system dropping lithium near the X-point and another into the low-field side divertor leg. The injection of lithium into the SOL reduced divertor recycling, as evidenced by reduced D α emission with ion flux measured by probes relatively unchanged. This effect is strongest in the active divertor, confirming the lithium is transported to strongly plasma-wetted areas. Furthermore, quantitative analysis of the recycling changes using the SOLPS edge plasma and neutral transport code indicated a ~20% reduction in recycling coefficient with lithium injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New insights on ion track morphology in pyrochlores by aberration corrected scanning transmission electron microscopy

Here we demonstrate the enhanced imaging capabilities of an aberration corrected scanning transmission electron microscope to advance the understanding of ion track structure in pyrochlore structured materials (i.e., Gd 2 Ti 2 O 7 and Gd 2 TiZrO 7 ). Track formation occurs due to the inelastic transfer of energy from incident ions to electrons, and atomic-level details of track morphology as a function of energy-loss are revealed in the present work. A comparison of imaging details obtained by varying collection angles of detectors is discussed in the present work. A quantitative analysis of phase identification using high-angle annular dark field imaging is performed on the ion tracks. Finally, a novel 3-dimensional track reconstruction method is provided that is based on depth dependent imaging of the ion tracks. The technique is used in extracting the atomic-level details of nanoscale features, such as the disordered ion tracks, which are embedded in relatively thicker matrix. Another relevance of the method is shown by measuring the tilt of the ion tracks relative to the electron beam incidence that helps in knowing the structure and geometry of ion tracks quantitatively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Offshore Wind Energy Leasing Areas for the Rhode Island/Massachusetts Wind Energy Area

The National Renewable Energy Laboratory (NREL), under an interagency agreement with the Bureau of Ocean Energy Management (BOEM), is providing technical assistance to BOEM on the identification and delineation of offshore leasing areas for offshore wind energy development within the Atlantic Coast Wind Energy Areas (WEAs) established by BOEM in 2012. This report focuses on NREL's evaluation of BOEM's Rhode Island/Massachusetts (RIMA) WEA leasing areas. The objective of the NREL evaluation was to assess the proposed delineation of the two leasing areas and determine if the division is reasonable and technically sound. Additionally, the evaluation aimed to identify any deficiencies in the delineation. As part of the review, NREL performed the following tasks: 1. Performed a limited review of relevant literature and RIMA call nominations. 2. Executed a quantitative analysis and comparison of the two proposed leasing areas 3. Conducted interviews with University of Rhode Island (URI) staff involved with the URI Special Area Management Plan (SAMP) 4. Prepared this draft report summarizing the key findings.

17 WIND ENERGY↗

Experimental study for the feasibility of using hard x-rays for micro-XRF analysis of multilayered metals

Application of polycapillary optical systems to improve a spatial resolution for the μ-XRF analysis by focusing a primary x-ray beam and/or by collecting fluorescence emission is well known. The challenge is to optimize them in combination with x-ray source for exciting K-lines above 20 keV that could allow characterization of many materials composed by heavy elements. To pursue this goal, preliminary studies on possible polycapillary lens employment in thickness determination for multilayer metal materials will be presented in this work. In this paper, the results of first attempts of integrating PyMCA with Monte Carlo simulation code (XMI-MSIM) that takes into account the secondary fluorescence effects on quantitative analysis of homogeneous matrices, in particular, metal alloys, are presented.

36 MATERIALS SCIENCE↗

Determination of total chlorine and bromine in solid wastes by sintering and inductively coupled plasma-sector field mass spectrometry

A sample preparation method based on sintering, followed by analysis by inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) for the simultaneous determination of chloride and bromide in diverse and mixed solid wastes, has been evaluated. Samples and reference materials of known composition were mixed with a sintering agent containing Na{sub 2}CO{sub 3} and ZnO and placed in an oven at 560 deg. C for 1 h. After cooling, the residues were leached with water prior to a cation-exchange assisted clean-up. Alternatively, a simple microwave-assisted digestion using only nitric acid was applied for comparison. Thereafter the samples were prepared for quantitative analysis by ICP-SFMS. The sintering method was evaluated by analysis of certified reference materials (CRMs) and by comparison with US EPA Method 5050 and ion chromatography with good agreement. Median RSDs for the sintering method were determined to 10% for both chlorine and bromine, and median recovery to 96% and 97%, respectively. Limits of detection (LODs) were 200 mg/kg for chlorine and 20 mg/kg for bromine. It was concluded that the sintering method is suitable for chlorine and bromine determination in several matrices like sewage sludge, plastics, and edible waste, as well as for waste mixtures. The sintering method was also applied for determination of other elements present in anionic forms, such as sulfur, arsenic, selenium and iodine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrorefining Bismuth Using AC Superimposed DC Waveforms

Bismuth has been successfully electrorefined using both direct current (DC) and alternating current (AC) superimposed DC waveforms on a kilogram scale at Brigham Young University (BYU) in Provo, Utah. Finding a suitable surrogate for Pu Electrorefining has always been a technical challenge. This work allows the possibility to improve Pu electrorefining with nonradioactive material at universities, which greatly reduces the cost at Lawrence Livermore National Laboratory (LLNL) for improving Pu Electrorefining. Several possible surrogates (Ce, In, Sn, Zn, and Bi) were selected based on their ability to mimic the Pu electrorefining process. Ce and In electrorefining experiments were conducted at the same temperature as Pu electrorefining in CaCl 2 while Sn, Zn, and Bi, electrorefining experiments were conducted at a lower temperature in a eutectic molten salt composed of LiCl, KCl, and CaCl 2 . The electrorefining experiments using Ce with a Ga impurity did not produce a cathode ring. While the remaining Ce anode after electrorefining was significantly less than what was initially added, Scanning Electron Microscopy with Energy Dispersive X-Ray (SEM-EDX) analysis showed that the Ce had been oxidized and formed a colloid with the surrounding molten salt. This is supported in the literature by analysis of Ce-rich CaCl 2 mixtures. All the electrorefining experiments except for the Ce electrorefining experiments did not introduce an impurity to the system. Electrorefining experiments with In showed that the InCl 3 volatilized out of the molten salt to an extent that only a low current (<<1 A) could be supported without decomposing the molten salt. Zn electrorefining experiments had marginal success, however an easily separable product was not formed. The Zn had to be rinsed from the salt after the experiment. Of the identified potential surrogates. Investigated, only Bi and Sn yielded an easily separable product ring, which enables quantitative analysis of yields and coulombic efficiencies. Bismuth was first identified as a surrogate at BYU, while Sn was identified as a surrogate at LLNL later. Thus, the electrorefining experiments conducted at BYU using AC superimposed DC waveforms used Bi as the metal to be electrorefined.

36 MATERIALS SCIENCE↗

Growth of Au on Pt Icosahedral Nanoparticles Revealed by Low-Dose In Situ TEM

A growth mode was revealed by an in situ TEM study of nucleation and growth of Au on Pt icosahedral nanoparticles. Quantitative analysis of growth kinetics was carried out based on real- time TEM data, which show the process involves: 1) deposition of Au on corner sites of Pt icosahedral nanoparticles, 2) diffusion of Au from corners to terraces and edges, and 3) subsequent layer-by-layer growth of Au on Au surfaces to form Pt@Au core-shell nanoparticles. The in situ TEM results indicate diffusion of Au from corner islands to terraces and edges is a kinetically controlled growth, as evidenced by a measurement of diffusion coefficients for these growth processes. We demonstrated that in situ electron microscopy is a valuable tool for quantitative study of nucleation and growth kinetics and can provide new insight into the design and precise control of heterogeneous nanostructures.

flow cell↗

Hanford Site Composite Analysis: Radionuclide Selection for Groundwater Pathway Evaluation.

The updated Hanford Site Composite Analysis (CA) will provide an all-pathways dose projection to a hypothetical future member of the public from all planned low-level radioactive waste disposal facilities and potential contributions from all other projected end-state sources of radioactive material left at the Hanford Site following site closure. Its primary purpose is to support the decision-making process of the U.S. Department of Energy (DOE) under DOE O 435.1-1, Radioactive Waste Management, related to managing low-level waste disposal facilities at the Hanford Site. A key aspect of conducting a CA is selecting the radionuclides to be included in the quantitative analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reorganization Energy of Electron Transfer in Ionic Liquids

We report bandshape analysis of charge-transfer optical bands in room-temperature ionic liquids (ILs) is performed to extract reorganization energy of electron transfer. Remarkably, the reorganization energies in ILs are close to those in cyclohexane. This result runs against common wisdom in the field since conducting ILs, characterized by an infinite static dielectric constant, and nonpolar cyclohexane fall to the opposite ends of the polarity scale based on their dielectric constants. Theoretical calculations employing structure factors of ILs from molecular dynamics simulations support low values of the reorganization energy. Standard dielectric arguments do not apply to solvation in ILs and nonergodic reorganization energies are required for a quantitative analysis.

14 SOLAR ENERGY↗

A fast and sensitive size-exclusion chromatography method for plasma extracellular vesicle proteomic analysis

Extracellular vesicles (EVs) carry diverse biomolecules derived from their parental cells, making their components excellent biomarker candidates. However, purifying EVs is a major hurdle in biomarker discovery since current methods require large amounts of samples, are time-consuming and typically have poor reproducibility. Here we describe a simple, fast, and sensitive EV fractionation method using size exclusion chromatography (SEC) on a fast protein liquid chromatography (FPLC) system. Our method uses a Superose 6 Increase 5/150, which has a bed volume of 2.9 mL. The FPLC system and small column size enable reproducible separation of only 50 µL of human plasma in 15 min. To demonstrate the utility of our method, we used longitudinal samples from a group of individuals who underwent intense exercise. A total of 838 proteins were identified, of which, 261 were previously characterized as EV proteins, including classical markers, such as cluster of differentiation (CD)9 and CD81. Quantitative analysis showed low technical variability with correlation coefficients greater than 0.9 between replicates. The analysis captured differences in relevant EV proteins involved in response to physical activity. Our method enables fast and sensitive fractionation of plasma EVs with low variability, which will facilitate biomarker studies in large clinical cohorts.

59 BASIC BIOLOGICAL SCIENCES↗

Results of the Aerosol Sampling Experiment on the International Space Station

The indoor air quality of the International Space Station (ISS), in terms of particulate matter, has been assessed through a sampling experiment that collected airborne debris for return to Earth. The Aerosol Sampling Experiment took place on ISS in December 2016 and January 2017, with sample return in February 2017. For redundancy, two different aerosol samplers collected particles in two size ranges spanning from 10 nm to hundreds of micrometers. Multiple analysis techniques have been used to characterize the particles, such as reflective light microscopy, manual scanning electron microscopy (SEM) analysis (secondary and backscattered imaging) with energy dispersive spectroscopy (EDS) x-ray analysis, computer controlled scanning electron microscopy (CCSEM) and Raman spectroscopy. Sampling took place in five locations on ISS, with the greatest deposition of particles in Node 3, followed by Node 1, the US Lab and Node 2. The PMM had very few airborne particles, as expected, owing to the lack of human presence. A large proportion of the sampled material consisted of fibers from clothing. Many particles had complex morphologies or contained multiple metals in a carbonaceous matrix. Metal particles were analyzed for each sampling location in terms of both weight and number percent, with 27 heavy metals detected. Fiberglass and TiO2 particles were present in every location. Quantitative analysis results are presented, and where possible, particle emission sources are identified with the intention to fuel discussions on mitigation.

Meyer, Marit E.↗

Analysis of control-oriented wake modeling tools using lidar field results

Abstract. The objective of this paper is to compare field data from a scanning lidar mounted on a turbine to control-oriented wind turbine wake models. The measurements were taken from the turbine nacelle looking downstream at the turbine wake. This field campaign was used to validate control-oriented tools used for wind plant control and optimization. The National Wind Technology Center in Golden, CO, conducted a demonstration of wake steering on a utility-scale turbine. In this campaign, the turbine was operated at various yaw misalignment set points, while a lidar mounted on the nacelle scanned five downstream distances. Primarily, this paper examines measurements taken at 2.35 diameters downstream of the turbine. The lidar measurements were combined with turbine data and measurements of the inflow made by a highly instrumented meteorological mast on-site. This paper presents a quantitative analysis of the lidar data compared to the control-oriented wake models used under different atmospheric conditions and turbine operation. Furthermore, these results show that good agreement is obtained between the lidar data and the models under these different conditions.

17 WIND ENERGY↗

A method to correct coordinate distortion in EBSD maps

Drift during electron backscatter diffraction mapping leads to coordinate distortions in resulting orientation maps, which affects, in some cases significantly, the accuracy of analysis. A method, thin plate spline, is introduced and tested to correct such coordinate distortions in the maps after the electron backscatter diffraction measurements. The accuracy of the correction as well as theoretical and practical aspects of using the thin plate spline method is discussed in detail. By comparing with other correction methods, it is shown that the thin plate spline method is most efficient to correct different local distortions in the electron backscatter diffraction maps. - Highlights: • A new method is suggested to correct nonlinear spatial distortion in EBSD maps. • The method corrects EBSD maps more precisely than presently available methods. • Errors less than 1–2 pixels are typically obtained. • Direct quantitative analysis of dynamic data are available after this correction.

36 MATERIALS SCIENCE↗